Maofei Qian
Research Subjects
Maofei Qian has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Qiaogen Zhou
Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
2 shared publications - H.F. Wang
Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
1 shared publication HongFei Wang
1 shared publicationJ.M. Zhang
Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
1 shared publication- Jidong Zhang
Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai 201210, Peoples R China
1 shared publication Jingmin Zhang
Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai 201210, Peoples R China
1 shared publication
Latest Publications
- 6 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-4
Cooling Design for the Magnetic Structure of SHINE Superconducting Undulator
- 6 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-4
Cooling Design for the Magnetic Structure of SHINE Superconducting Undulator
- Open Access
- 1 September 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1067 (8) , 082016
The Magnetic Field Measurement Systems for a Cryogenic Undulator and a Superconducting Undulator at SSRF
Two cryogenic permanent magnet undulators (CPMU) have been developed and assembled into storage ring at Shanghai Synchrotron Radiation Facility (SSRF) in order to produce higher brilliance in the hard X rays domain. At low temperatures, permanent magnet materials can provide both higher magnetic field and higher resistance to radiation-induced demagnetization of the magnet compared to room temperature operation. Test results indicate that lowering the temperature of permanent magnets (Nd2Fe14B) increases the magnetic field strength about by 11%. The magnetic field distribution of the CPMU must be measured after the magnetic arrays are installed into the vacuum chamber and cooled to cryogenic temperature. We have finished a magnetic measurement bench based on a Hall probe to perform cryogenic temperature measurement. In this papers, the details of the magnetic field measurement system and some test results of a CPMU20 with 20mm period and Nd2Fe14B type are described. In addition, two superconducting planar undulator (SCU) prototypes with period 16mm are also under development at SSRF to research some key technologies.
- 1 September 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1067 (8) , 082016
Open AccessThe Magnetic Field Measurement Systems for a Cryogenic Undulator and a Superconducting Undulator at SSRF
Two cryogenic permanent magnet undulators (CPMU) have been developed and assembled into storage ring at Shanghai Synchrotron Radiation Facility (SSRF) in order to produce higher brilliance in the hard X rays domain. At low temperatures, permanent magnet materials can provide both higher magnetic field and higher resistance to radiation-induced demagnetization of the magnet compared to room temperature operation. Test results indicate that lowering the temperature of permanent magnets (Nd2Fe14B) increases the magnetic field strength about by 11%. The magnetic field distribution of the CPMU must be measured after the magnetic arrays are installed into the vacuum chamber and cooled to cryogenic temperature. We have finished a magnetic measurement bench based on a Hall probe to perform cryogenic temperature measurement. In this papers, the details of the magnetic field measurement system and some test results of a CPMU20 with 20mm period and Nd2Fe14B type are described. In addition, two superconducting planar undulator (SCU) prototypes with period 16mm are also under development at SSRF to research some key technologies.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 26 (4) , 1
The Magnetic Performance of an Exotic APPLE-Knot Undulator Developed at SSRF
An exotic PPM undulator which consists of eight rows of pure permanent magnets is developed at Shanghai Synchrotron Radiation Facility (SSRF). With the four quasi-periodic magnet arrays of APPLE-II type and four additional arrays of Knot type with the different period length, the undulator can produce various polarized light with very low radiation power on axis and low higher harmonics radiation. The magnet design of the undulator and the simulations of the spectrum and the power distribution are described in this paper.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 26 (4) , 1
The Magnetic Performance of an Exotic APPLE-Knot Undulator Developed at SSRF
An exotic PPM undulator which consists of eight rows of pure permanent magnets is developed at Shanghai Synchrotron Radiation Facility (SSRF). With the four quasi-periodic magnet arrays of APPLE-II type and four additional arrays of Knot type with the different period length, the undulator can produce various polarized light with very low radiation power on axis and low higher harmonics radiation. The magnet design of the undulator and the simulations of the spectrum and the power distribution are described in this paper.