Jennifer Grant
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Jennifer Grant has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Milan Mrksich
Department of Biomedical Engineering, Northwestern University, 2145 Sheridan Road, Evanston, Illinois 60208, United States
5 shared publications - Donald Elliot Ingber
Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, USA
3 shared publications Rachelle Prantil-Baun
Wyss Institute
3 shared publications- Alican Özkan
Wyss Institute for Biologically Inspired Engineering at Harvard University, Boston, MA, USA
2 shared publications - Blaise R. Kimmel
The Ohio State University
2 shared publications - Gautam Mahajan
Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
2 shared publications
Latest Publications
- Open Access
Establishment of physiologically relevant oxygen gradients in microfluidic organ chips
In vitro models of human organs must accurately reconstitute oxygen concentrations and gradients that are observed in vivo to mimic gene expression, metabolism, and host-microbiome interactions. Here we describe a simple strategy to achieve physiologically relevant oxygen tension in a two-channel human small intestine-on-a-chip (Intestine Chip) lined with primary human duodenal epithelium and intestinal microvascular endothelium in parallel channels separated by a porous membrane while both channels are perfused with oxygenated medium. This strategy was developed using computer simulations that predicted lowering the oxygen permeability of poly-dimethlysiloxane (PDMS) chips in specified locations using a gas impermeable film will allow the cells to naturally decrease the oxygen concentration through aerobic respiration and reach steady-state oxygen levels < 36 mm Hg (< 5%) within the epithelial lumen. The approach was experimentally confirmed using chips with embedded oxygen sensors that maintained this stable oxygen gradient. Furthermore, Intestine Chips cultured with this approach supported formation of a villus epithelium interfaced with a continuous endothelium and maintained intestinal barrier integrity for 72 h. This strategy recapitulates in vivo functionality in an efficient, inexpensive, and scalable format that improves the robustness and translatability of Organ Chip technology for studies on microbiome as well as oxygen sensitivity.
Open AccessEstablishment of physiologically relevant oxygen gradients in microfluidic organ chips
In vitro models of human organs must accurately reconstitute oxygen concentrations and gradients that are observed in vivo to mimic gene expression, metabolism, and host-microbiome interactions. Here we describe a simple strategy to achieve physiologically relevant oxygen tension in a two-channel human small intestine-on-a-chip (Intestine Chip) lined with primary human duodenal epithelium and intestinal microvascular endothelium in parallel channels separated by a porous membrane while both channels are perfused with oxygenated medium. This strategy was developed using computer simulations that predicted lowering the oxygen permeability of poly-dimethlysiloxane (PDMS) chips in specified locations using a gas impermeable film will allow the cells to naturally decrease the oxygen concentration through aerobic respiration and reach steady-state oxygen levels < 36 mm Hg (< 5%) within the epithelial lumen. The approach was experimentally confirmed using chips with embedded oxygen sensors that maintained this stable oxygen gradient. Furthermore, Intestine Chips cultured with this approach supported formation of a villus epithelium interfaced with a continuous endothelium and maintained intestinal barrier integrity for 72 h. This strategy recapitulates in vivo functionality in an efficient, inexpensive, and scalable format that improves the robustness and translatability of Organ Chip technology for studies on microbiome as well as oxygen sensitivity.
- Open Access
- 10 December 2021
- Published by Wiley in Chemistry – A European Journal
- Vol. 28 (12) , e202103807
Characterizing Enzyme Cooperativity with Imaging SAMDI‐MS
This paper describes a method that combines a microfluidic device and self‐assembled monolayers for matrix‐assisted laser desorption/ionization mass spectrometry (SAMDI) mass spectrometry to calculate the cooperativity in binding of calcium ions to peptidylarginine deiminase type 2 (PAD2). This example uses only 120 μL of enzyme solution and three fluidic inputs. This microfluidic device incorporates a self‐assembled monolayer that is functionalized with a peptide substrate for PAD2. The enzyme and different concentrations of calcium ions are flowed through each of eight channels, where the position along the channel corresponds to reaction time and position across the channel corresponds to the concentration of Ca2+. Imaging SAMDI (iSAMDI) is then used to determine the yield for the enzyme reaction at each 200 μm pixel on the monolayer, providing a time course for the reactions. Analysis of the peptide conversion as a function of position and time gives the degree of cooperativity (n) and the concentration of ligand required for half maximal activity (K0.5) for the Ca2+ – dependent activation of PAD2. This work establishes a high‐throughput and label‐free method for studying enzyme‐ligand binding interactions and widens the applicability of microfluidics and matrix‐assisted laser desorption/ionization mass spectrometry (MALDI) imaging mass spectrometry.
- 10 December 2021
- Published by Wiley in Chemistry – A European Journal
- Vol. 28 (12) , e202103807
Open AccessCharacterizing Enzyme Cooperativity with Imaging SAMDI‐MS
This paper describes a method that combines a microfluidic device and self‐assembled monolayers for matrix‐assisted laser desorption/ionization mass spectrometry (SAMDI) mass spectrometry to calculate the cooperativity in binding of calcium ions to peptidylarginine deiminase type 2 (PAD2). This example uses only 120 μL of enzyme solution and three fluidic inputs. This microfluidic device incorporates a self‐assembled monolayer that is functionalized with a peptide substrate for PAD2. The enzyme and different concentrations of calcium ions are flowed through each of eight channels, where the position along the channel corresponds to reaction time and position across the channel corresponds to the concentration of Ca2+. Imaging SAMDI (iSAMDI) is then used to determine the yield for the enzyme reaction at each 200 μm pixel on the monolayer, providing a time course for the reactions. Analysis of the peptide conversion as a function of position and time gives the degree of cooperativity (n) and the concentration of ligand required for half maximal activity (K0.5) for the Ca2+ – dependent activation of PAD2. This work establishes a high‐throughput and label‐free method for studying enzyme‐ligand binding interactions and widens the applicability of microfluidics and matrix‐assisted laser desorption/ionization mass spectrometry (MALDI) imaging mass spectrometry.
- 27 July 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (18) , 3509-3519
Simulating drug concentrations in PDMS microfluidic organ chips
Microfluidic organ-on-a-chip (Organ Chip) cell culture devices are often fabricated using polydimethylsiloxane (PDMS) because it is biocompatible, transparent, elastomeric, and oxygen permeable; however, hydrophobic small molecules can absorb to PDMS, which makes it challenging to predict drug responses. Here, we describe a combined simulation and experimental approach to predict the spatial and temporal concentration profile of a drug under continuous dosing in a PDMS Organ Chip containing two parallel channels separated by a porous membrane that is lined with cultured cells, without prior knowledge of its log P value. First, a three-dimensional finite element model of drug loss into the chip was developed that incorporates absorption, adsorption, convection, and diffusion, which simulates changes in drug levels over time and space as a function of potential PDMS diffusion coefficients and log P values. By then experimentally measuring the diffusivity of the compound in PDMS and determining its partition coefficient through mass spectrometric analysis of the drug concentration in the channel outflow, it is possible to estimate the effective log P range of the compound. The diffusion and partition coefficients were experimentally derived for the antimalarial drug and potential SARS-CoV-2 therapeutic, amodiaquine, and incorporated into the model to quantitatively estimate the drug-specific concentration profile over time measured in human lung airway chips lined with bronchial epithelium interfaced with pulmonary microvascular endothelium. The same strategy can be applied to any device geometry, surface treatment, or in vitro microfluidic model to simulate the spatial and temporal gradient of a drug in 3D without prior knowledge of the partition coefficient or the rate of diffusion in PDMS. Thus, this approach may expand the use of PDMS Organ Chip devices for various forms of drug testing.
- 27 July 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (18) , 3509-3519
Simulating drug concentrations in PDMS microfluidic organ chips
Microfluidic organ-on-a-chip (Organ Chip) cell culture devices are often fabricated using polydimethylsiloxane (PDMS) because it is biocompatible, transparent, elastomeric, and oxygen permeable; however, hydrophobic small molecules can absorb to PDMS, which makes it challenging to predict drug responses. Here, we describe a combined simulation and experimental approach to predict the spatial and temporal concentration profile of a drug under continuous dosing in a PDMS Organ Chip containing two parallel channels separated by a porous membrane that is lined with cultured cells, without prior knowledge of its log P value. First, a three-dimensional finite element model of drug loss into the chip was developed that incorporates absorption, adsorption, convection, and diffusion, which simulates changes in drug levels over time and space as a function of potential PDMS diffusion coefficients and log P values. By then experimentally measuring the diffusivity of the compound in PDMS and determining its partition coefficient through mass spectrometric analysis of the drug concentration in the channel outflow, it is possible to estimate the effective log P range of the compound. The diffusion and partition coefficients were experimentally derived for the antimalarial drug and potential SARS-CoV-2 therapeutic, amodiaquine, and incorporated into the model to quantitatively estimate the drug-specific concentration profile over time measured in human lung airway chips lined with bronchial epithelium interfaced with pulmonary microvascular endothelium. The same strategy can be applied to any device geometry, surface treatment, or in vitro microfluidic model to simulate the spatial and temporal gradient of a drug in 3D without prior knowledge of the partition coefficient or the rate of diffusion in PDMS. Thus, this approach may expand the use of PDMS Organ Chip devices for various forms of drug testing.
- Open Access
Predicting drug concentrations in PDMS microfluidic organ chips
Microfluidic organ-on-a-chip (Organ Chip) cell culture devices are often fabricated using polydimethylsiloxane (PDMS) because it is biocompatible, transparent, elastomeric, and oxygen permeable; however, hydrophobic small molecules can absorb to PDMS, which makes it challenging to predict drug responses. Here, we describe a combined simulation and experimental approach to predict the spatial and temporal concentration profile of a drug under continuous dosing in a PDMS Organ Chip containing two parallel channels separated by a porous membrane that is lined with cultured cells, without prior knowledge of its log P value. First, a three-dimensional finite element simulation of drug loss into the chip was developed that incorporates absorption, adsorption, convection, and diffusion, which predicts changes in drug levels over time and space as a function of potential PDMS diffusion coefficients and log P values. By then experimentally measuring the diffusivity of the compound in PDMS and determining its partition coefficient through mass spectrometric analysis of the drug concentration in the channel outflow, it is possible to estimate the effective log P range of the compound. The diffusion and partition coefficients were experimentally derived for the antimalarial drug and potential SARS-CoV-2 therapeutic, amodiaquine, and incorporated into the model to quantitatively predict the drug-specific concentration profile over time measured in human Lung Airway Chips lined with bronchial epithelium interfaced with pulmonary microvascular endothelium. The same strategy can be applied to any device geometry, surface treatment, or in vitro microfluidic model to predict the spatial and temporal gradient of a drug in 3D without prior knowledge of the partition coefficient or the rate of diffusion in PDMS. Thus, this approach may expand the use of PDMS Organ Chip devices for various forms of drug testing.
Open AccessPredicting drug concentrations in PDMS microfluidic organ chips
Microfluidic organ-on-a-chip (Organ Chip) cell culture devices are often fabricated using polydimethylsiloxane (PDMS) because it is biocompatible, transparent, elastomeric, and oxygen permeable; however, hydrophobic small molecules can absorb to PDMS, which makes it challenging to predict drug responses. Here, we describe a combined simulation and experimental approach to predict the spatial and temporal concentration profile of a drug under continuous dosing in a PDMS Organ Chip containing two parallel channels separated by a porous membrane that is lined with cultured cells, without prior knowledge of its log P value. First, a three-dimensional finite element simulation of drug loss into the chip was developed that incorporates absorption, adsorption, convection, and diffusion, which predicts changes in drug levels over time and space as a function of potential PDMS diffusion coefficients and log P values. By then experimentally measuring the diffusivity of the compound in PDMS and determining its partition coefficient through mass spectrometric analysis of the drug concentration in the channel outflow, it is possible to estimate the effective log P range of the compound. The diffusion and partition coefficients were experimentally derived for the antimalarial drug and potential SARS-CoV-2 therapeutic, amodiaquine, and incorporated into the model to quantitatively predict the drug-specific concentration profile over time measured in human Lung Airway Chips lined with bronchial epithelium interfaced with pulmonary microvascular endothelium. The same strategy can be applied to any device geometry, surface treatment, or in vitro microfluidic model to predict the spatial and temporal gradient of a drug in 3D without prior knowledge of the partition coefficient or the rate of diffusion in PDMS. Thus, this approach may expand the use of PDMS Organ Chip devices for various forms of drug testing.
- Open Access
- 12 February 2019
- Published by American Chemical Society (ACS) in ACS Central Science
- Vol. 5 (3) , 486-493
Using Microfluidics and Imaging SAMDI-MS To Characterize Reaction Kinetics
Microfluidic platforms have enabled the simplification of biochemical assays with a significant reduction in the use of reagents, yet the current methods available for analyzing reaction products can limit applications of these approaches. This paper demonstrates a simple microfluidic device that incorporates a functionalized self-assembled monolayer to measure the rate constant for a chemical reaction. The device mixes the reactants and allows them to selectively immobilize to the monolayer at the base of a microfluidic channel in a time-dependent manner as they flow down the channel. Imaging self-assembled monolayers for matrix-assisted laser desorption/ionization mass spectrometry (iSAMDI-MS) is used to acquire a quantitative image representing the time-resolved progress of the reaction as it flowed through the channel. Knowledge of the surface immobilization chemistry and the fluid front characteristics allows for the determination of the chemical reaction rate constant. This approach widens the applicability of microfluidics for chemical reaction monitoring and establishes a label-free method for studying processes that occur within a dispersive regime.
- 12 February 2019
- Published by American Chemical Society (ACS) in ACS Central Science
- Vol. 5 (3) , 486-493
Open AccessUsing Microfluidics and Imaging SAMDI-MS To Characterize Reaction Kinetics
Microfluidic platforms have enabled the simplification of biochemical assays with a significant reduction in the use of reagents, yet the current methods available for analyzing reaction products can limit applications of these approaches. This paper demonstrates a simple microfluidic device that incorporates a functionalized self-assembled monolayer to measure the rate constant for a chemical reaction. The device mixes the reactants and allows them to selectively immobilize to the monolayer at the base of a microfluidic channel in a time-dependent manner as they flow down the channel. Imaging self-assembled monolayers for matrix-assisted laser desorption/ionization mass spectrometry (iSAMDI-MS) is used to acquire a quantitative image representing the time-resolved progress of the reaction as it flowed through the channel. Knowledge of the surface immobilization chemistry and the fluid front characteristics allows for the determination of the chemical reaction rate constant. This approach widens the applicability of microfluidics for chemical reaction monitoring and establishes a label-free method for studying processes that occur within a dispersive regime.
- 14 November 2018
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 10 (47) , 40452-40459
Photoactivatable Reaction for Covalent Nanoscale Patterning of Multiple Proteins
This paper describes a photochemical approach for independently patterning multiple proteins to an inert substrate, particularly for studies of cell adhesion. A photoactivatable chloropyrimidine ligand was employed for covalent immobilization of SnapTag fusion proteins on self-assembled monolayers of alkanethiolates on gold. A two-step procedure was used, where first patterned UV illumination of the surface activated protein capture ligands, and second incubation with a SnapTag fusion protein bound to the surface in illuminated regions. Two different fluorescent proteins were patterned in registry with feature sizes of 400 nm over a 1 mm2 area. An example wherein an anti-CEA scFv antibody was patterned to direct the selective attachment of a human cancer cell line that express the CEA antigen. This method enables the preparation of surfaces with control over the density and activity of independently patterned proteins.
- 14 November 2018
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 10 (47) , 40452-40459
Photoactivatable Reaction for Covalent Nanoscale Patterning of Multiple Proteins
This paper describes a photochemical approach for independently patterning multiple proteins to an inert substrate, particularly for studies of cell adhesion. A photoactivatable chloropyrimidine ligand was employed for covalent immobilization of SnapTag fusion proteins on self-assembled monolayers of alkanethiolates on gold. A two-step procedure was used, where first patterned UV illumination of the surface activated protein capture ligands, and second incubation with a SnapTag fusion protein bound to the surface in illuminated regions. Two different fluorescent proteins were patterned in registry with feature sizes of 400 nm over a 1 mm2 area. An example wherein an anti-CEA scFv antibody was patterned to direct the selective attachment of a human cancer cell line that express the CEA antigen. This method enables the preparation of surfaces with control over the density and activity of independently patterned proteins.
- 26 September 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (21) , 13096-13103
High-Throughput Enzyme Kinetics with 3D Microfluidics and Imaging SAMDI Mass Spectrometry
Microfluidic systems are important for performing precise reagent manipulations and reducing material consumption in biological assays. However, optical detection methods limit analyses to fluorescent or UV-active compounds and traditional 2D fluidic designs have limited degrees of freedom. This paper describes a microfluidic device that has three inputs and performs 2,592 distinct enzyme reactions using only 150 µL of reagent with quantitative characterization. This paper also introduces imaging self-assembled monolayers for matrix-assisted laser desorption/ionization mass spectrometry (iSAMDI-MS) to map reaction progress−by immobilization of the product onto the floor of the microfluidic channel−into an image that is used for calculating the Michaelis constant (Km). This approach expands the scope of imaging mass spectrometry (IMS), microfluidic detection strategies, and the design of high-throughput reaction systems.
- 26 September 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (21) , 13096-13103
High-Throughput Enzyme Kinetics with 3D Microfluidics and Imaging SAMDI Mass Spectrometry
Microfluidic systems are important for performing precise reagent manipulations and reducing material consumption in biological assays. However, optical detection methods limit analyses to fluorescent or UV-active compounds and traditional 2D fluidic designs have limited degrees of freedom. This paper describes a microfluidic device that has three inputs and performs 2,592 distinct enzyme reactions using only 150 µL of reagent with quantitative characterization. This paper also introduces imaging self-assembled monolayers for matrix-assisted laser desorption/ionization mass spectrometry (iSAMDI-MS) to map reaction progress−by immobilization of the product onto the floor of the microfluidic channel−into an image that is used for calculating the Michaelis constant (Km). This approach expands the scope of imaging mass spectrometry (IMS), microfluidic detection strategies, and the design of high-throughput reaction systems.
An Immobilized Enzyme Reactor for Spatiotemporal Control over Reaction Products
This paper describes a microfluidic chip wherein the position and order of two immobilized enzymes affects the type and quantity of reaction products in the flowing fluid. Assembly of the chip is based on a self‐assembled monolayer presenting two orthogonal covalent capture ligands that immobilize their respective fusion enzyme. A thiol‐tagged substrate is flowed over a region presenting the first enzyme—which generates a product that is efficiently transferred to the second enzyme—and the second enzyme's product binds to an adjacent thiol capture site on the chip. The amount of the three possible reaction products is quantified directly on the chip using self‐assembled monolayers for matrix‐assisted laser desorption/ionization mass spectrometry, revealing that the same microsystem can be spatiotemporally arranged to produce different products depending on the device design. This work allows for optimizing multistep biochemical transformations in favor of a desired product using a facile reaction and analytical format.
An Immobilized Enzyme Reactor for Spatiotemporal Control over Reaction Products
This paper describes a microfluidic chip wherein the position and order of two immobilized enzymes affects the type and quantity of reaction products in the flowing fluid. Assembly of the chip is based on a self‐assembled monolayer presenting two orthogonal covalent capture ligands that immobilize their respective fusion enzyme. A thiol‐tagged substrate is flowed over a region presenting the first enzyme—which generates a product that is efficiently transferred to the second enzyme—and the second enzyme's product binds to an adjacent thiol capture site on the chip. The amount of the three possible reaction products is quantified directly on the chip using self‐assembled monolayers for matrix‐assisted laser desorption/ionization mass spectrometry, revealing that the same microsystem can be spatiotemporally arranged to produce different products depending on the device design. This work allows for optimizing multistep biochemical transformations in favor of a desired product using a facile reaction and analytical format.
- Open Access
- 17 December 2016
- Published by Instituto Colombiano de Antropologia e Historia (ICANH) in Revista Colombiana de Antropología
- Vol. 52 (2) , 199-227
Análisis de paleodietas humanas en zonas áridas a través de isótopos estables: el caso de Antofagasta de la Sierra (noroeste argentino)
- 17 December 2016
- Published by Instituto Colombiano de Antropologia e Historia (ICANH) in Revista Colombiana de Antropología
- Vol. 52 (2) , 199-227
Open AccessAnálisis de paleodietas humanas en zonas áridas a través de isótopos estables: el caso de Antofagasta de la Sierra (noroeste argentino)
On‐Chip Screening of Experimental Conditions for the Synthesis of Noble‐Metal Nanostructures with Different Morphologies
The applications of nanostructures critically depend on their morphologies. Although significant progress has been made in the chemical synthesis of nanostructures with a variety of different morphologies, it is still highly desired to develop an approach that allows one to quickly identify the best set of parameters for nanostructure syntheses. Herein, an on‐chip approach to the rapid screening of experimental conditions pivotal to the production of nanostructures with different morphologies is reported. The key component of this approach is an array of reactors containing solutions with a one‐ or two‐dimensional gradient in reagent concentration, pH value, or reaction temperature. In the proof‐of‐concept experiments, the parameters needed for the production of Au and Pd nanostructures with various morphologies are quickly identified. In principle, this approach can be extended to other systems for rapid screening and optimization of experimental conditions involved in the syntheses of different types of nanostructures.
On‐Chip Screening of Experimental Conditions for the Synthesis of Noble‐Metal Nanostructures with Different Morphologies
The applications of nanostructures critically depend on their morphologies. Although significant progress has been made in the chemical synthesis of nanostructures with a variety of different morphologies, it is still highly desired to develop an approach that allows one to quickly identify the best set of parameters for nanostructure syntheses. Herein, an on‐chip approach to the rapid screening of experimental conditions pivotal to the production of nanostructures with different morphologies is reported. The key component of this approach is an array of reactors containing solutions with a one‐ or two‐dimensional gradient in reagent concentration, pH value, or reaction temperature. In the proof‐of‐concept experiments, the parameters needed for the production of Au and Pd nanostructures with various morphologies are quickly identified. In principle, this approach can be extended to other systems for rapid screening and optimization of experimental conditions involved in the syntheses of different types of nanostructures.