Yoshiro Yamada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yoshiro Yamada has a total of 208 co-authors. Here are the top co-authors by number of shared publications:
- Naohiko Sasajima
National Metrology Institute of Japan, AIST
20 shared publications - Juntaro Ishii
National Metrology Institute of Japan, AIST
18 shared publications P. Bloembergen
Research Institute for Physical Measurement, National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563, Japan Division of Thermophysics and Process Measurements, National Institute of Metrology (NIM), No. 18 Bei San Huan Dong Lu, Beijing 100029, People's Republic of China
10 shared publications- Yu Yamaguchi
National Metrology Institute of Japan (Japan)
10 shared publications - Mohamed Sadli
Laboratoire Commun de Métrologie LNE-CNAM
8 shared publications T. Wang
Division of Thermophysics and Process Measurements, National Institute of Metrology (NIM), No. 18 Bei San Huan Dong Lu, Beijing 100029, People's Republic of China
6 shared publications
Latest Publications
- Open Access
- 29 May 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (22) , 220202
Announcing the 2025 measurement science and technology outstanding paper awards
Since 1991, Measurement Science and Technology (MST) has awarded best paper prizes. The Editorial Board of this journal believe that such prizes are an opportunity to thank authors for submitting their work, and serve as an integral part of the ongoing quality review of the journal. The current breadth of topical areas that are covered by MST has made it advisable to expand the recognition of excellent publications. Hence, since 2005 the editorial board have presented ‘Outstanding Paper Awards’. This year awards were given in the areas of fluid mechanics, optical and laser-based techniques, precision measurement, sensors and sensing systems, measurement science, and biological, healthcare and life sciences.
- 29 May 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (22) , 220202
Open AccessAnnouncing the 2025 measurement science and technology outstanding paper awards
Since 1991, Measurement Science and Technology (MST) has awarded best paper prizes. The Editorial Board of this journal believe that such prizes are an opportunity to thank authors for submitting their work, and serve as an integral part of the ongoing quality review of the journal. The current breadth of topical areas that are covered by MST has made it advisable to expand the recognition of excellent publications. Hence, since 2005 the editorial board have presented ‘Outstanding Paper Awards’. This year awards were given in the areas of fluid mechanics, optical and laser-based techniques, precision measurement, sensors and sensing systems, measurement science, and biological, healthcare and life sciences.
- 6 June 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (9) , 090201
Announcing the 2023 measurement science and technology outstanding paper awards
- 6 June 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (9) , 090201
Announcing the 2023 measurement science and technology outstanding paper awards
- 1 March 2024
- Published by American Meteorological Society in Journal of Atmospheric and Oceanic Technology
- Vol. 41 (3) , 309-318
2022 CEOS International Thermal Infrared Radiometer Comparison. Part II: Field Comparison of Radiometers
An international comparison of field-deployed radiometers for sea surface skin temperature (SSTskin) retrieval was conducted during two weeks in June 2022. The comparison comprised a laboratory comparison and a field comparison. The field comparison of the radiometers took place on the second week at a seaside pier on the south coast of England. Six thermal infrared radiometers were compared with each other while continuously viewing the closely adjacent surface of the sea from the end of the pier. This paper reports the results of this field comparison. All participants’ radiometers agreed with the reference value, evaluated as the simple mean of the participant-reported values, within the claimed uncertainties. The SSTskin variation during the 5-day period was within 3°C around 18.3°C, which is 2 times as large in range as in the previous comparison in 2016, while the mean of the difference from the reference value over the period evaluated for each participant was found to be within 0.07°C, which is a 2-times improvement on the previous results. During the comparison an insignificant but noticeable abrupt shift in measured value occurred in one of the radiometers, which could not have been detected without comparison with other instruments. This demonstrated the effectiveness of having long-term stable internal reference sources in the instrument, a feature this particular radiometer did not have. The combined results from the laboratory comparison and the field comparison contribute to improve confidence in the retrieved SSTskin.
- 1 March 2024
- Published by American Meteorological Society in Journal of Atmospheric and Oceanic Technology
- Vol. 41 (3) , 309-318
2022 CEOS International Thermal Infrared Radiometer Comparison. Part II: Field Comparison of Radiometers
An international comparison of field-deployed radiometers for sea surface skin temperature (SSTskin) retrieval was conducted during two weeks in June 2022. The comparison comprised a laboratory comparison and a field comparison. The field comparison of the radiometers took place on the second week at a seaside pier on the south coast of England. Six thermal infrared radiometers were compared with each other while continuously viewing the closely adjacent surface of the sea from the end of the pier. This paper reports the results of this field comparison. All participants’ radiometers agreed with the reference value, evaluated as the simple mean of the participant-reported values, within the claimed uncertainties. The SSTskin variation during the 5-day period was within 3°C around 18.3°C, which is 2 times as large in range as in the previous comparison in 2016, while the mean of the difference from the reference value over the period evaluated for each participant was found to be within 0.07°C, which is a 2-times improvement on the previous results. During the comparison an insignificant but noticeable abrupt shift in measured value occurred in one of the radiometers, which could not have been detected without comparison with other instruments. This demonstrated the effectiveness of having long-term stable internal reference sources in the instrument, a feature this particular radiometer did not have. The combined results from the laboratory comparison and the field comparison contribute to improve confidence in the retrieved SSTskin.
- 1 March 2024
- Published by American Meteorological Society in Journal of Atmospheric and Oceanic Technology
- Vol. 41 (3) , 295-307
2022 CEOS International Thermal Infrared Radiometer Comparison. Part I: Laboratory Comparison of Radiometers and Blackbodies
An international comparison of field deployed radiometers for sea surface skin temperature (SSTskin) retrieval was conducted in June 2022. The campaign comprised a laboratory comparison and a field comparison. In the laboratory part, the radiometers were compared with reference standard blackbodies, while the same was done with the blackbodies used for the calibration of the radiometers against a transfer standard radiometer. Reference values were provided by the National Physical Laboratory (NPL), traceable to the primary standard on the International Temperature Scale of 1990. This was followed by the field comparison at a seaside pier on the south coast of England, where the radiometers were compared against each other while viewing the closely adjacent surface of the sea. This paper reports the results of the laboratory comparison of radiometers and blackbodies. For the blackbody comparison, the brightness temperature of the blackbody reported by the participants agreed with the reference value measured by the NPL transfer standard radiometer within the uncertainties for all temperatures and for all blackbodies. For the radiometer comparison, the temperature range of most interest from the SSTskin retrieval point of view is 10°–30°C, and in this temperature range, and up to the maximum comparison temperature of 50°C, all participants’ reported results were in agreement with the reference. On the other hand, below 0°C the reported values showed divergence from the reference and the differences exceeded the uncertainties. The divergence shows there is room for improvement in uncertainty estimation at lower temperatures, although it will have limited implication in the SSTskin retrieval.
- 1 March 2024
- Published by American Meteorological Society in Journal of Atmospheric and Oceanic Technology
- Vol. 41 (3) , 295-307
2022 CEOS International Thermal Infrared Radiometer Comparison. Part I: Laboratory Comparison of Radiometers and Blackbodies
An international comparison of field deployed radiometers for sea surface skin temperature (SSTskin) retrieval was conducted in June 2022. The campaign comprised a laboratory comparison and a field comparison. In the laboratory part, the radiometers were compared with reference standard blackbodies, while the same was done with the blackbodies used for the calibration of the radiometers against a transfer standard radiometer. Reference values were provided by the National Physical Laboratory (NPL), traceable to the primary standard on the International Temperature Scale of 1990. This was followed by the field comparison at a seaside pier on the south coast of England, where the radiometers were compared against each other while viewing the closely adjacent surface of the sea. This paper reports the results of the laboratory comparison of radiometers and blackbodies. For the blackbody comparison, the brightness temperature of the blackbody reported by the participants agreed with the reference value measured by the NPL transfer standard radiometer within the uncertainties for all temperatures and for all blackbodies. For the radiometer comparison, the temperature range of most interest from the SSTskin retrieval point of view is 10°–30°C, and in this temperature range, and up to the maximum comparison temperature of 50°C, all participants’ reported results were in agreement with the reference. On the other hand, below 0°C the reported values showed divergence from the reference and the differences exceeded the uncertainties. The divergence shows there is room for improvement in uncertainty estimation at lower temperatures, although it will have limited implication in the SSTskin retrieval.
- 16 October 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (6) , 065005
A novel radiometric calibration of an infrared thermometer
A new temperature calibration scheme was proposed and implemented on the National Physical Laboratory infrared radiometer Absolute Measurements of Blackbody Emitted Radiance (AMBER) operating in the wavelength range from 9 µm to 11 µm and equipped with a cryogenically cooled mercury cadmium telluride detector. The scheme involves measurements of the relative spectral responsivity of the filter radiometer including the spectral transmittance of the window and lens. It requires calibration at two reference temperatures, but does not involve measurement of the zero-radiance signal. The scheme uses a Ga-point blackbody as one reference point, and a variable temperature blackbody source at close to −30 °C with its temperature measured with a standard platinum resistance thermometer as the other. The measured temperature was compared using the variable temperature blackbody as the source against the temperature measured by the standard platinum resistance thermometer and agreement within the uncertainties was confirmed at intermediate temperatures. The scheme has the advantage that it makes full use of the small uncertainty realised by the fixed-point blackbody. The scheme was successfully implemented in an international comparison of sea surface temperature measuring radiometers where AMBER served to provide the reference.
- 16 October 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (6) , 065005
A novel radiometric calibration of an infrared thermometer
A new temperature calibration scheme was proposed and implemented on the National Physical Laboratory infrared radiometer Absolute Measurements of Blackbody Emitted Radiance (AMBER) operating in the wavelength range from 9 µm to 11 µm and equipped with a cryogenically cooled mercury cadmium telluride detector. The scheme involves measurements of the relative spectral responsivity of the filter radiometer including the spectral transmittance of the window and lens. It requires calibration at two reference temperatures, but does not involve measurement of the zero-radiance signal. The scheme uses a Ga-point blackbody as one reference point, and a variable temperature blackbody source at close to −30 °C with its temperature measured with a standard platinum resistance thermometer as the other. The measured temperature was compared using the variable temperature blackbody as the source against the temperature measured by the standard platinum resistance thermometer and agreement within the uncertainties was confirmed at intermediate temperatures. The scheme has the advantage that it makes full use of the small uncertainty realised by the fixed-point blackbody. The scheme was successfully implemented in an international comparison of sea surface temperature measuring radiometers where AMBER served to provide the reference.
- 9 June 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (9) , 090101
Announcing the 2022 Measurement Science and Technology Outstanding Paper Awards
- 9 June 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (9) , 090101
Announcing the 2022 Measurement Science and Technology Outstanding Paper Awards
- 20 October 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (1) , 015010
Emissivity-free radiation thermometry for high-temperature metals using the dual-wavelength reflectance-ratio method
This article describes a preliminary study verifying the applicability of the dual-wavelength reflectance-ratio (DWR) method to emissivity-free radiation thermometry for electromagnetically levitated high-temperature liquid metals. To establish the measurement technique, the DWR method was applied to inductively heated solid spherical Cu and Ni samples. Regardless of the differences in the sample emissivity values, the temperature determined using the DWR method agreed within 20 K with the temperature determined using a thermocouple. It was found that the temperatures of metallic samples having different emissivity values can be determined with a standard uncertainty of 8 K in terms of the absolute temperature when applying the DWR method, even if the sample has curvature and is exposed to high temperatures of up to 1250 K.
- 20 October 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (1) , 015010
Emissivity-free radiation thermometry for high-temperature metals using the dual-wavelength reflectance-ratio method
This article describes a preliminary study verifying the applicability of the dual-wavelength reflectance-ratio (DWR) method to emissivity-free radiation thermometry for electromagnetically levitated high-temperature liquid metals. To establish the measurement technique, the DWR method was applied to inductively heated solid spherical Cu and Ni samples. Regardless of the differences in the sample emissivity values, the temperature determined using the DWR method agreed within 20 K with the temperature determined using a thermocouple. It was found that the temperatures of metallic samples having different emissivity values can be determined with a standard uncertainty of 8 K in terms of the absolute temperature when applying the DWR method, even if the sample has curvature and is exposed to high temperatures of up to 1250 K.
- 7 April 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (7) , 070201
Announcing the 2021 Measurement Science and Technology Outstanding Paper Awards
- 7 April 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (7) , 070201
Announcing the 2021 Measurement Science and Technology Outstanding Paper Awards
- Open Access
- 1 January 2021
- Published by Taylor & Francis in SICE Journal of Control, Measurement, and System Integration
- Vol. 14 (1) , 107-115
A study on infrared thermometer measurement capabilities in the calibration laboratories and the user community in Japan
A comparison circulating a standard infrared thermometer, a handy infrared thermometer, and a thermal imager was conducted among eleven participants from the industrial user, academic user, and calibration laboratory communities of these thermometers in Japan. The result revealed that the scatter width of the reported value for the handy type thermometer was as large as 31 °C at 450 °C. Investigation into the cause of the discrepancy showed that the treatment of emissivity of the source was one large factor, which is relevant when using contact thermometer or a near infrared radiation thermometer as the reference. Large SSE of the handy thermometer linked to the definition of the targeting distance of the thermometer on the blackbody cavity also played a major role. The comparison successfully identified the shortcomings of the current calibration practices, and the result can be utilized to greatly improve the reliability of the infrared thermometer scale in future.
- 1 January 2021
- Published by Taylor & Francis in SICE Journal of Control, Measurement, and System Integration
- Vol. 14 (1) , 107-115
Open AccessA study on infrared thermometer measurement capabilities in the calibration laboratories and the user community in Japan
A comparison circulating a standard infrared thermometer, a handy infrared thermometer, and a thermal imager was conducted among eleven participants from the industrial user, academic user, and calibration laboratory communities of these thermometers in Japan. The result revealed that the scatter width of the reported value for the handy type thermometer was as large as 31 °C at 450 °C. Investigation into the cause of the discrepancy showed that the treatment of emissivity of the source was one large factor, which is relevant when using contact thermometer or a near infrared radiation thermometer as the reference. Large SSE of the handy thermometer linked to the definition of the targeting distance of the thermometer on the blackbody cavity also played a major role. The comparison successfully identified the shortcomings of the current calibration practices, and the result can be utilized to greatly improve the reliability of the infrared thermometer scale in future.
- 7 December 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (2) , 020101
Special Section on TEMPMEKO 2019: a feature on the XIV International Symposium on Temperature and Thermal Measurements in Industry and Science & IV International Temperature Conference, Beijing (TEMPMEKO & TEMPBEIJING 2019) and Metrology for Meteorology and Climate (MMC 2019)
- 7 December 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (2) , 020101
Special Section on TEMPMEKO 2019: a feature on the XIV International Symposium on Temperature and Thermal Measurements in Industry and Science & IV International Temperature Conference, Beijing (TEMPMEKO & TEMPBEIJING 2019) and Metrology for Meteorology and Climate (MMC 2019)