Yu Yamaguchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yu Yamaguchi has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
- Yoshiro Yamada
National Physical Laboratory, Teddington, United Kingdom
10 shared publications - Juntaro Ishii
National Metrology Institute of Japan, AIST
4 shared publications - Andrew Douglas William Todd
National Research Council Canada
2 shared publications - Dolores del Campo
Centro Español de Metrología, Alfar 2, 28760 Tres Cantos, Spain
2 shared publications - Maria Luisa Hernanz
Consejo Superior de Investigaciones Cientificas (Spain)
2 shared publications - Mark Ballico
National Measurement Institute
2 shared publications
Latest Publications
- 1 December 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (12) , 125111
Potential for improving the local realization of coordinated universal time with a convolutional neural network
The time difference between coordinated universal time (UTC) and a hydrogen maser, which is a master oscillator for the local realization of UTC at the National Metrology Institute of Japan (NMIJ), has been predicted by using one of the deep learning techniques called a one-dimensional convolutional neural network (1D-CNN). Regarding the prediction result obtained by the 1D-CNN, we have observed improvement in the accuracy of prediction compared with that obtained by the Kalman filter. Although more investigations are required to conclude that the 1D-CNN can work as a good predictor, the present results suggest that the computational approach based on the deep learning technique may become a versatile method for improving the synchronous accuracy of UTC(NMIJ) relative to UTC.
- 1 December 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (12) , 125111
Potential for improving the local realization of coordinated universal time with a convolutional neural network
The time difference between coordinated universal time (UTC) and a hydrogen maser, which is a master oscillator for the local realization of UTC at the National Metrology Institute of Japan (NMIJ), has been predicted by using one of the deep learning techniques called a one-dimensional convolutional neural network (1D-CNN). Regarding the prediction result obtained by the 1D-CNN, we have observed improvement in the accuracy of prediction compared with that obtained by the Kalman filter. Although more investigations are required to conclude that the 1D-CNN can work as a good predictor, the present results suggest that the computational approach based on the deep learning technique may become a versatile method for improving the synchronous accuracy of UTC(NMIJ) relative to UTC.
- 25 May 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (3) , 390-398
The equilibrium liquidus temperatures of rhenium–carbon, platinum–carbon and cobalt–carbon eutectic alloys
The eutectic alloys rhenium–carbon, platinum–carbon and cobalt–carbon have been proposed as reference standards for thermometry, with temperature and uncertainty values specified within the mise en pratique of the definition of the kelvin. These alloys have been investigated in a collaboration of eleven national measurement institutes and laboratories. Published results reported the point-of-inflection in the melting curve with extremely low uncertainties. However, to be considered as standards it is necessary to stipulate what phenomenon a temperature value has been ascribed to; specifically, this should be a thermodynamic state. Therefore, the data have been further evaluated and the equilibrium liquidus temperatures determined based on a consideration of limits and assuming a rectangular probability distribution. The values are: for rhenium–carbon 2747.91 ± 0.44 K, for platinum–carbon 2011.50 ± 0.22 K and for cobalt–carbon 1597.48 ± 0.14 K, with uncertainties at approximately a 95% coverage probability. It is proposed that these values could be used as the basis of thermodynamic temperature measurement at high temperatures (above 1300 K).
- 25 May 2017
- Published by IOP Publishing in Metrologia
- Vol. 54 (3) , 390-398
The equilibrium liquidus temperatures of rhenium–carbon, platinum–carbon and cobalt–carbon eutectic alloys
The eutectic alloys rhenium–carbon, platinum–carbon and cobalt–carbon have been proposed as reference standards for thermometry, with temperature and uncertainty values specified within the mise en pratique of the definition of the kelvin. These alloys have been investigated in a collaboration of eleven national measurement institutes and laboratories. Published results reported the point-of-inflection in the melting curve with extremely low uncertainties. However, to be considered as standards it is necessary to stipulate what phenomenon a temperature value has been ascribed to; specifically, this should be a thermodynamic state. Therefore, the data have been further evaluated and the equilibrium liquidus temperatures determined based on a consideration of limits and assuming a rectangular probability distribution. The values are: for rhenium–carbon 2747.91 ± 0.44 K, for platinum–carbon 2011.50 ± 0.22 K and for cobalt–carbon 1597.48 ± 0.14 K, with uncertainties at approximately a 95% coverage probability. It is proposed that these values could be used as the basis of thermodynamic temperature measurement at high temperatures (above 1300 K).
- 13 February 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (4) , 49
Thermodynamic Temperature Measurement to the Indium Point Based on Radiance Comparison
- 13 February 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (4) , 49
Thermodynamic Temperature Measurement to the Indium Point Based on Radiance Comparison
- Open Access
- 28 March 2016
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 374 (2064) , 20150044
Thermodynamic temperature assignment to the point of inflection of the melting curve of high-temperature fixed points
The thermodynamic temperature of the point of inflection of the melting transition of Re-C, Pt-C and Co-C eutectics has been determined to be 2747.84 ± 0.35 K, 2011.43 ± 0.18 K and 1597.39 ± 0.13 K, respectively, and the thermodynamic temperature of the freezing transition of Cu has been determined to be 1357.80 ± 0.08 K, where the ± symbol represents 95% coverage. These results are the best consensus estimates obtained from measurements made using various spectroradiometric primary thermometry techniques by nine different national metrology institutes. The good agreement between the institutes suggests that spectroradiometric thermometry techniques are sufficiently mature (at least in those institutes) to allow the direct realization of thermodynamic temperature above 1234 K (rather than the use of a temperature scale) and that metal-carbon eutectics can be used as high-temperature fixed points for thermodynamic temperature dissemination. The results directly support the developing mise en pratique for the definition of the kelvin to include direct measurement of thermodynamic temperature.
- 28 March 2016
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 374 (2064) , 20150044
Open AccessThermodynamic temperature assignment to the point of inflection of the melting curve of high-temperature fixed points
The thermodynamic temperature of the point of inflection of the melting transition of Re-C, Pt-C and Co-C eutectics has been determined to be 2747.84 ± 0.35 K, 2011.43 ± 0.18 K and 1597.39 ± 0.13 K, respectively, and the thermodynamic temperature of the freezing transition of Cu has been determined to be 1357.80 ± 0.08 K, where the ± symbol represents 95% coverage. These results are the best consensus estimates obtained from measurements made using various spectroradiometric primary thermometry techniques by nine different national metrology institutes. The good agreement between the institutes suggests that spectroradiometric thermometry techniques are sufficiently mature (at least in those institutes) to allow the direct realization of thermodynamic temperature above 1234 K (rather than the use of a temperature scale) and that metal-carbon eutectics can be used as high-temperature fixed points for thermodynamic temperature dissemination. The results directly support the developing mise en pratique for the definition of the kelvin to include direct measurement of thermodynamic temperature.
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 116-119
Notice of Removal Emissivity-free thermal imaging with dual-wavelength reflectance-ratio method
Removed.
- 1 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 116-119
Notice of Removal Emissivity-free thermal imaging with dual-wavelength reflectance-ratio method
Removed.
- 14 June 2015
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 36 (8) , 1825-1833
Supercontinuum-Source-Based Facility for Absolute Calibration of Radiation Thermometers
- 14 June 2015
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 36 (8) , 1825-1833
Supercontinuum-Source-Based Facility for Absolute Calibration of Radiation Thermometers
- 24 October 2013
- Published by SPIE-Intl Soc Optical Eng
- p. 888927-888927-6
Supercontinuum-source-based facility for evaluation of hyperspectral imagers
- 24 October 2013
- Published by SPIE-Intl Soc Optical Eng
- p. 888927-888927-6
Supercontinuum-source-based facility for evaluation of hyperspectral imagers
- 10 September 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 688
Uncertainty due to non-linearity in radiation thermometers calibrated by multiple fixed points
A new method to estimate the uncertainty due to non-linearity is described on the n = 3 scheme basis. The expression of uncertainty is mathematically derived applying the random walk method. The expression is simple and requires only the temperatures of the fixed points and a relative uncertainty value for each flux-doubling derived from the non-linearity measurement. We also present an example of the method, in which the uncertainty of temperature measurement by a radiation thermometer is calculated on the basis of non-linearity measurement.
- 10 September 2013
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1552 (1) , 688
Uncertainty due to non-linearity in radiation thermometers calibrated by multiple fixed points
A new method to estimate the uncertainty due to non-linearity is described on the n = 3 scheme basis. The expression of uncertainty is mathematically derived applying the random walk method. The expression is simple and requires only the temperatures of the fixed points and a relative uncertainty value for each flux-doubling derived from the non-linearity measurement. We also present an example of the method, in which the uncertainty of temperature measurement by a radiation thermometer is calculated on the basis of non-linearity measurement.
- 19 November 2012
- Published by SPIE-Intl Soc Optical Eng
- p. 85331K-85331K-7
Supercontinuum source-based system for pre-launch calibration of the hyperspectral sensor
- 19 November 2012
- Published by SPIE-Intl Soc Optical Eng
- p. 85331K-85331K-7
Supercontinuum source-based system for pre-launch calibration of the hyperspectral sensor