Yozo Shimada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yozo Shimada has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Hitoshi Iida
National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan
10 shared publications Kazuhiko Hirakawa
Univ. of Tokyo (Japan)
7 shared publications- Masanori Ishii
National Institute of Advanced Industrial Science and Technology, National Metrology Institute of Japan, Tsukuba, Ibaraki, Japan
7 shared publications - Moto Kinoshita
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
7 shared publications Hideki Kuroda
Otsuka Electronics Company, Ltd., Osaka, Japan
4 shared publicationsK Hirakawa
University of Tokyo
4 shared publications
Latest Publications
- 19 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 4 (6) , 756-759
Frequency Calibration of Terahertz Time-Domain Spectrometer Using Air-Gap Etalon
Although various terahertz (THz) technologies have been rapidly developed in recent years, their metrology standards are yet to be established. We have developed a simple calibration method for the frequency of a THz time-domain spectrometer (TDS) using an optically transparent THz air-gap etalon (OT-TAGE). The OT-TAGE can be used in both the near-infrared (NIR) and THz regions. Therefore, a frequency measurement using THz waves can be directly compared with one using NIR light via the OT-TAGE. In this study, the frequency of a commercial THz-TDS was calibrated by referring to the NIR wavelength was demonstrated. The obtained frequency errors were within ± 3 GHz, with relative uncertainties within 1%.
- 19 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 4 (6) , 756-759
Frequency Calibration of Terahertz Time-Domain Spectrometer Using Air-Gap Etalon
Although various terahertz (THz) technologies have been rapidly developed in recent years, their metrology standards are yet to be established. We have developed a simple calibration method for the frequency of a THz time-domain spectrometer (TDS) using an optically transparent THz air-gap etalon (OT-TAGE). The OT-TAGE can be used in both the near-infrared (NIR) and THz regions. Therefore, a frequency measurement using THz waves can be directly compared with one using NIR light via the OT-TAGE. In this study, the frequency of a commercial THz-TDS was calibrated by referring to the NIR wavelength was demonstrated. The obtained frequency errors were within ± 3 GHz, with relative uncertainties within 1%.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21622027,p. 1-2
Improvement of transmission characteristics of a terahertz step attenuator
This paper presents a method of improving the transmission characteristics of a terahertz step attenuator. The transmittance of the step attenuator was measured using a terahertz time-domain spectrometer (THz-TDS). Flat transmittances at each attenuation step were obtained at frequencies up to 3 THz by combining several 6-μm-thick metalized film attenuators (MFAs). The attenuator had no significant polarization dependence over a wide frequency range. Good short-term and long-term repeatability were also confirmed.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21622027,p. 1-2
Improvement of transmission characteristics of a terahertz step attenuator
This paper presents a method of improving the transmission characteristics of a terahertz step attenuator. The transmittance of the step attenuator was measured using a terahertz time-domain spectrometer (THz-TDS). Flat transmittances at each attenuation step were obtained at frequencies up to 3 THz by combining several 6-μm-thick metalized film attenuators (MFAs). The attenuator had no significant polarization dependence over a wide frequency range. Good short-term and long-term repeatability were also confirmed.
- 28 January 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 62 (6) , 1807-1813
Optimization of the Atomic Candle Signal for the Precise Measurement of Microwave Power
To use the atomic candle signals of Cs atoms for the measurement of microwave power, the main parameters such as a standing or running microwave in the glass cell containing Cs atoms, the probing position in the waveguide, the intensity of the probing laser, the pressure of the $\hbox{N}_{2}$ buffer gas, and the beam diameter were optimized. As a result, the average uncertainty in obtaining the Rabi frequency, whose accuracy is important for the measurement of microwave power, was reduced several-fold. We demonstrated the measurement of microwave power using the optimized atomic candle signal in our previous work. In this paper, we discuss the optimization process in detail and the utility of optimizing the atomic candle signal for the precise measurement of microwave power.- 28 January 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 62 (6) , 1807-1813
Optimization of the Atomic Candle Signal for the Precise Measurement of Microwave Power
To use the atomic candle signals of Cs atoms for the measurement of microwave power, the main parameters such as a standing or running microwave in the glass cell containing Cs atoms, the probing position in the waveguide, the intensity of the probing laser, the pressure of the $\hbox{N}_{2}$ buffer gas, and the beam diameter were optimized. As a result, the average uncertainty in obtaining the Rabi frequency, whose accuracy is important for the measurement of microwave power, was reduced several-fold. We demonstrated the measurement of microwave power using the optimized atomic candle signal in our previous work. In this paper, we discuss the optimization process in detail and the utility of optimizing the atomic candle signal for the precise measurement of microwave power.- 16 November 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 62 (6) , 1801-1806
Validation of Power Linearity in Terahertz Time-Domain Spectroscopy Using a Programmable Step Attenuator
We have constructed a programmable terahertz step attenuator by stacking metallized-film attenuators (MFAs) of different transmittances. Sputter deposition of Inconel alloy on thin polyester films is used to fabricate the MFAs. Good repeatability and flatness of the step attenuator are confirmed in transmittance measurements by a terahertz time-domain spectroscopy (THz-TDS) system. A method to evaluate the linearity of the THz-TDS system is proposed by using the step attenuator over a wide dynamic range. Calibration curves are analyzed by measuring the transmittance of maltose in different concentrations, and the validity of the proposed method is discussed.
- 16 November 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 62 (6) , 1801-1806
Validation of Power Linearity in Terahertz Time-Domain Spectroscopy Using a Programmable Step Attenuator
We have constructed a programmable terahertz step attenuator by stacking metallized-film attenuators (MFAs) of different transmittances. Sputter deposition of Inconel alloy on thin polyester films is used to fabricate the MFAs. Good repeatability and flatness of the step attenuator are confirmed in transmittance measurements by a terahertz time-domain spectroscopy (THz-TDS) system. A method to evaluate the linearity of the THz-TDS system is proposed by using the step attenuator over a wide dynamic range. Calibration curves are analyzed by measuring the transmittance of maltose in different concentrations, and the validity of the proposed method is discussed.
- 1 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Development of compatible air-gap etalons used with both terahertz wave and near-infrared light
We have developed compatible air-gap etalons that can be used with both terahertz (THz) waves and near-infrared (NIR) light. The free spectral ranges for a THz wave and NIR light were in good agreement. This result shows that the air-gap etalons can be used to link the frequencies of two rays. This new type of etalon has potential for use as a simple and easy validation tool for THz time-domain spectroscopy.
- 1 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Development of compatible air-gap etalons used with both terahertz wave and near-infrared light
We have developed compatible air-gap etalons that can be used with both terahertz (THz) waves and near-infrared (NIR) light. The free spectral ranges for a THz wave and NIR light were in good agreement. This result shows that the air-gap etalons can be used to link the frequencies of two rays. This new type of etalon has potential for use as a simple and easy validation tool for THz time-domain spectroscopy.
- 1 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Experimental investigation of a metalized-film attenuator for validation of terahertz time-domain spectroscopy
We have experimentally investigated the terahertz (THz) transmission properties of metalized-film attenuators (MFAs) with base film thicknesses of 6 μm and 25 μm. Transmittance of the MFAs was measured by a THz time-domain spectrometer. Good flatness and repeatability of the transmittance were verified for the 6 μm-thick MFA in the frequency range up to 3 THz.
- 1 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Experimental investigation of a metalized-film attenuator for validation of terahertz time-domain spectroscopy
We have experimentally investigated the terahertz (THz) transmission properties of metalized-film attenuators (MFAs) with base film thicknesses of 6 μm and 25 μm. Transmittance of the MFAs was measured by a THz time-domain spectrometer. Good flatness and repeatability of the transmittance were verified for the 6 μm-thick MFA in the frequency range up to 3 THz.
- 29 November 2011
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 50 (12R) , 128004
Power Linearity Measurement in Terahertz Time-Domain Spectroscopy Using Metalized Film Attenuators
We describe a method for evaluating the power linearity over a wide dynamic range of a terahertz time-domain spectroscopy (THz-TDS) system. The dynamic range is achieved by means of metalized film attenuators (MFAs). The evaluation was based on repeated measurements of transmittance in a particular sample at different incident power levels. We apply the method to both focused- and collimated-beam systems and show that the method can be applied to reflectance measurements as well.
- 29 November 2011
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 50 (12R) , 128004
Power Linearity Measurement in Terahertz Time-Domain Spectroscopy Using Metalized Film Attenuators
We describe a method for evaluating the power linearity over a wide dynamic range of a terahertz time-domain spectroscopy (THz-TDS) system. The dynamic range is achieved by means of metalized film attenuators (MFAs). The evaluation was based on repeated measurements of transmittance in a particular sample at different incident power levels. We apply the method to both focused- and collimated-beam systems and show that the method can be applied to reflectance measurements as well.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 101-106
Comparison between three-antenna method and equivalent capacitance substitution method for calibrating electrically short monopole antenna
In low-frequency bands, monopole antennas are generally used for measuring the electromagnetic interference (EMI) and estimating the electric field strength. The antenna factor is an important and widely studied characteristic. Thus far, there have been a number of measurement methods proposed for electrically short monopole antennas. A case in point is the equivalent capacitance substitution method, which is commonly used for monopole antenna measurements. On the other hand, we have proposed a near-field three-antenna method for electrically short monopole antennas. These two absolute measurement methods are of quite different origins. In light of this fact, a comparison is made between the two measurement methods by means of experiments and simulations, and the difference observed between the antenna factors is discussed.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 101-106
Comparison between three-antenna method and equivalent capacitance substitution method for calibrating electrically short monopole antenna
In low-frequency bands, monopole antennas are generally used for measuring the electromagnetic interference (EMI) and estimating the electric field strength. The antenna factor is an important and widely studied characteristic. Thus far, there have been a number of measurement methods proposed for electrically short monopole antennas. A case in point is the equivalent capacitance substitution method, which is commonly used for monopole antenna measurements. On the other hand, we have proposed a near-field three-antenna method for electrically short monopole antennas. These two absolute measurement methods are of quite different origins. In light of this fact, a comparison is made between the two measurement methods by means of experiments and simulations, and the difference observed between the antenna factors is discussed.
- 28 March 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 60 (7) , 2308-2313
Auxiliary-Transmission-Line Method for Calibrating Noise Temperature of a Microwave Thermal Noise Source
We have proposed and discussed a method to calibrate the effective noise temperature (ENT) of a noise source by using an auxiliary transmission line (ATL). A cryogenic 7-mm coaxial noise source was developed for verifying the ATL method. The ENT is determined from the parameters evaluated by a radiometer and the available power ratio of the transmission line measured by a vector network analyzer. The calibrated ENT by this method was 139.8 K-143.6 K with an expanded uncertainty of 4.0 K-4.6 K (k = 2) in the frequency range of 8-12 GHz. We also performed a comparison of the ENT using two different methods: an ordinary radiometer measurement using two reference noise sources and a theoretical calculation method analyzing temperature and loss distribution along the transmission line. The experimental results show the validity of the ATL method for determining the ENT.
- 28 March 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 60 (7) , 2308-2313
Auxiliary-Transmission-Line Method for Calibrating Noise Temperature of a Microwave Thermal Noise Source
We have proposed and discussed a method to calibrate the effective noise temperature (ENT) of a noise source by using an auxiliary transmission line (ATL). A cryogenic 7-mm coaxial noise source was developed for verifying the ATL method. The ENT is determined from the parameters evaluated by a radiometer and the available power ratio of the transmission line measured by a vector network analyzer. The calibrated ENT by this method was 139.8 K-143.6 K with an expanded uncertainty of 4.0 K-4.6 K (k = 2) in the frequency range of 8-12 GHz. We also performed a comparison of the ENT using two different methods: an ordinary radiometer measurement using two reference noise sources and a theoretical calculation method analyzing temperature and loss distribution along the transmission line. The experimental results show the validity of the ATL method for determining the ENT.
- 1 July 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2158110X,p. 56-61
A reference antenna method for non-resonant electrically short monopole antennas
In order to measure the electric field strength in low-frequency bands, monopole antennas are generally used. When carrying out EMI measurements, the antenna factor is an important and well-known characteristic. Generally, absolute calibration methods are commonly used for monopole antenna calibrations. However, establishing and keeping the traceability to standard quantities in absolute calibration methods are time consuming. In this paper, a new reference antenna method for non-resonant electrically short monopole antennas is proposed and investigated through a numerical simulation. Since the target frequency band is less than 30 MHz, the monopole antennas work as electrically short monopole antennas. The measurements are performed under the near-field condition. The results show that the proposed reference antenna method is available and effective in obtaining the antenna factor of a non-resonant electrically short monopole antenna.
- 1 July 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2158110X,p. 56-61
A reference antenna method for non-resonant electrically short monopole antennas
In order to measure the electric field strength in low-frequency bands, monopole antennas are generally used. When carrying out EMI measurements, the antenna factor is an important and well-known characteristic. Generally, absolute calibration methods are commonly used for monopole antenna calibrations. However, establishing and keeping the traceability to standard quantities in absolute calibration methods are time consuming. In this paper, a new reference antenna method for non-resonant electrically short monopole antennas is proposed and investigated through a numerical simulation. Since the target frequency band is less than 30 MHz, the monopole antennas work as electrically short monopole antennas. The measurements are performed under the near-field condition. The results show that the proposed reference antenna method is available and effective in obtaining the antenna factor of a non-resonant electrically short monopole antenna.