DBDuncan Mark Brooks

Duncan Mark Brooks

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Duncan Mark Brooks has a total of 91 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • MRI in CFD for chronic type B aortic dissection: Ready for prime time?

    by Qingdi Wang, Xiaojing Guo, Mark Brooks, Jason Chuen, Eric K.W. Poon, Andrew Ooi, Ruth P. Lim


  • Open Access

    Y Stent Rendezvous to Treat Symptomatic Innominate Artery Stenosis

    by Goran Mitreski, Hamed Asadi, Mark Duncan Brooks

    A male in his 60s presented with transient ischemic attacks 5 years after aortic arch branch graft repair for type A aortic dissection. Computed tomographic angiography demonstrated 80% stenosis of the brachiocephalic artery close to the origins of the right common carotid and subclavian arteries. The case was reviewed at our multidisciplinary aortic meeting and a plan for endovascular management was made. Percutaneous endovascular Y stenting from the innominate artery into the left common carotid and subclavian arteries was achieved using self-expanding nitinol stents with a rendezvous technique that included retrograde right radial artery, retrograde right external carotid artery, and retrograde right femoral arterial approaches. At 6 months review, the stents remained widely patent and the patient was symptom-free.

  • International Study of Intracranial Aneurysm Treatment Using Woven EndoBridge: Results of the WorldWideWEB Consortium

    by Adam A. Dmytriw, Jose Danilo Bengzon Diestro, Mahmoud Dibas, Kevin Phan, Ahmad Sweid, Hugo H. Cuellar-Saenz, Sovann V. Lay, Adrien Guenego, Leonardo Renieri, Ali Al Balushi, et al.


  • Open Access

    CaRotid Artery Filtering Technique (CRAFT): A Technique for Carotid Artery Stenting with Intrinsic Embolic Protection

    by Michelle Foo, Yifan Ren, Jay Gajera, Christen D Barras, Hong Kuan Kok, Ashu Jhamb, Hussein Abbouchie, Julian Maingard, Duncan Mark Brooks, Hamed Asadi

    Purpose: Carotid artery stenting (CAS) is an established treatment for symptomatic carotid artery stenosis as an alternative to carotid endarterectomy. A variety of techniques and devices have been devised to minimise periprocedural stroke risk using either proximal or distal embolic protection. This study presents a method of embolic protection during CAS–the CaRotid Artery Filtering Technique (CRAFT).Materials and Methods: The CRAFT technique employs aspects of both proximal and distal embolic protection. The CASPER RX stent (MicroVention, Tustin, CA, USA), which is a double-layered, closed-cell, micromesh nitinol stent, is deployed across the carotid artery stenosis with the assistance of a FlowGate balloon guide catheter (Stryker Neurovascular, Fremont, CA, USA). The partially deployed stent acts as a distal filter while the balloon guide is deflated midway during stent deployment to prevent distal plaque embolisation, followed by completion of stent deployment and angioplasty.Results: A total of 94 patients underwent CAS using the CRAFT technique between June 2016 and March 2021. Successful stent deployment was achieved in all patients. Preliminary results demonstrated acute stent occlusion in 6 patients (6.4%) and distal embolic stroke in 5 patients (5.3%). The median procedural fluoroscopy time was 34 minutes with an interquartile range of 22 to 55 minutes.Conclusion: The CRAFT technique of CAS presented by this study can be applied in the treatment of symptomatic carotid artery stenosis in both emergency and elective procedure settings with a high technical success and low distal embolic stroke risk.


  • Open Access

    Endovascular Treatment of Intracranial Aneurysms Using the Novel Low Profile Visualized Intraluminal Support EVO Stent: Multicenter Early Feasibility Experience

    by Michelle Foo, Julian Maingard, Jonathan Hall, Yifan Ren, Goran Mitreski, Lee-Anne Slater, Ronil Chandra, Winston Chong, Ashu Jhamb, Jeremy Russell, et al.

    Purpose: Low-profile, self-expandable stents have broadened therapeutic options available for definitive treatment of intracranial aneurysms. The novel Low-Profile Visualized Intraluminal Support (LVIS) EVO stent extends upon the success of its predecessor, the LVIS Jr stent, aiming to enable higher visibility and greater opening ability within a self-expandable and fully retrievable microstent system. In this study, we aim to report the early safety and feasibility experience with the LVIS EVO stent.Materials and Methods: A multicenter, retrospective, observational study was conducted on patients who had intracranial aneurysms treated with the LVIS EVO stent across 3 Australian neurovascular centers between February 2020 and September 2020. Short-term technical and clinical outcomes were evaluated.Results: A total of 22 LVIS EVO stents were successfully implanted to treat 15 aneurysms (3 ruptured, 12 unruptured) in 15 patients. Aneurysms ranged from 2 mm to 35 mm in dome height. The LVIS EVO stent was used for stent-assisted coiling in 11 patients and flow diversion in 4 patients. There were no device-related procedural complications. There were 2 cases of peri-procedural symptomatic thromboembolic complications and no procedure-related mortality. At early radiological follow up, 10 patients had complete occlusion, 4 patients had small neck remnants, and 1 patient who was managed with flow diversion had a residual aneurysm.Conclusion: Early experience with the LVIS EVO stent demonstrated safety and feasibility for stent-assisted coiling as well as flow diversion for intracranial aneurysms. In this heterogeneous cohort, including ruptured, complex, and large aneurysms, all cases were technically successful.


  • Combined interventional radiology and surgical management of a complex caesarean scar ectopic pregnancy

    by Suraindra M Rajadurai, Avelyn Wong, Duncan Mark Brooks, Carol Vance

    Caesarean scar ectopic pregnancies are rare but growing in incidence due to increasing rates of caesarean deliveries. These cases have historically been treated with either medical or surgical management which both have significant limitations. More recently, uterine artery embolisation (UAE) has shown significant promise in the treatment of this condition. We present the case of a complex patient with a caesarean scar ectopic successfully managed with combined UAE and surgery.


  • Open Access

    Endovascular treatment of visceral artery and renal aneurysms (VRAA) using a constant mesh density flow diverting stent

    by Julian Maingard, Anthony Lamanna, Hong Kuan Kok, Dinesh Ranatunga, Rajeev Ravi, Ronil V. Chandra, Michael J. Lee, Duncan Mark Brooks, Hamed Asadi

    Flow diverting stents have been used safely and effectively for the treatment of intracranial aneurysms, particularly for large and wide necked aneurysms that are not amenable to conventional endovascular treatment with coiling. The Surpass Streamline device (Stryker Neurovascular, MI, USA) is a relatively new and unique flow diverting stent which maintains constant device mesh density over varying vessel diameters. This may potentially provide advantages compared to other flow diverting stents in achieving aneurysmal occlusion. Two patients with VRAA were treated using the Surpass Streamline device. The first patient was a 65-year-old male with an incidental 2.4 cm aneurysm originating from the hepatic artery near the gastroduodenal artery (GDA). The second patient was a 56-year-old male with an incidental 1.9 cm renal aneurysm arising from an anterior inferior segmental branch of the left renal artery. A Surpass flow diverting stent was used to successfully exclude the aneurysm neck in both cases. Reduced flow was achieved in one patient (equivalent to O’Kelly-Marotta [OKM] Grade B1). Preserved flow and stagnation (equivalent to OKM Grade A3) was achieved in the other. There was preserved distal flow in the parent arteries. No immediate complications were encountered in either case. Complete occlusion of both aneurysms was seen on follow up CT angiographic imaging within 8-weeks. The Surpass flow diverting stent can be used safely and effectively to treat VRAA. It should be considered in unruptured large and giant wide necked VRAAs aneurysms. Additional large prospective studies are required for further validation.


  • The future of interventional and neurointerventional radiology: learning lessons from the past

    by Julian Maingard, Hong Kuan Kok, Dinesh Ranatunga, Duncan Mark Brooks, Ronil V. Chandra, Michael J. Lee, Hamed Asadi

    The rapid progression of medical imaging technology and the ability to leverage knowledge from non-invasive imaging means that Interventional Radiologists (IRs) and Interventional Neuroradiologists are optimally placed to incorporate minimally invasive interventional paradigms into clinical management to advance patient care. There is ample opportunity to radically change the management options for patients with a variety of diseases through the use of minimally invasive interventional procedures. However, this will need to be accompanied by an increased clinical role of IRs to become active partners in the clinical management of patients. Unfortunately, the development of IR clinical presence has lagged behind and is reflected by declining rates of IR involvement in certain areas of practice such as vascular interventions. Current and future IRs must be willing to take on clinical responsibilities; reviewing patients in clinic to determine suitability for a procedure and potential contraindications, roun...