Hariharan Ramakrishnan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hariharan Ramakrishnan has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Vallabh Mahadevan
Department of Prosthodontics and Implantology, Ragas Dental College and Hospital, Chennai, IND
8 shared publications- Jayakrishnakumar Sampathkumar
Ragas Dental College & Hospital, Chennai, India
7 shared publications Azhagarasan Nagarasampatti Sivaprakasam
Ragas Dental College & Hospital, Chennai, Tamilnadu, India
5 shared publicationsNagarasampatti Sivaprakasam Azhagarasan
Ragas Dental College & Hospital, Chennai, India
4 shared publicationsNs Azhagarasan
Ragas Dent Coll & Hosp, Dept Prosthodont, Chennai, Tamil Nadu, India
4 shared publicationsChitra Shankar Krishnan
Department of Prosthodontics and Implantology, Ragas Dental College & Hospital, Chennai, India
3 shared publications
Latest Publications
- Open Access
- 18 April 2025
- Published by Elsevier in Journal of Oral Biology and Craniofacial Research
- Vol. 15  (4) , 663-669
Comparative evaluation of Microarc Oxidation and sandblasting on the retention of cement-retained implant restorations: An in-vitro study
- 18 April 2025
- Published by Elsevier in Journal of Oral Biology and Craniofacial Research
- Vol. 15  (4) , 663-669
Open AccessComparative evaluation of Microarc Oxidation and sandblasting on the retention of cement-retained implant restorations: An in-vitro study
- Open Access
- 7 September 2023
- Published by Springer Nature in Cureus
- Vol. 15  (9) , e44816
Escherichia coli Cellular Activity and Frontal Trizonal Evaluation of Microspace Between Implants and Abutments Under Calibrated Cyclic Stress
Aim: To evaluate microspace and microleakage between implant and abutments subjected to pre- and post-calibrated cyclic stress. Materials and methods: Twelve screw-retained implant prostheses with BioHPP polyetheretherketone (PEEK) abutment (Noris Dental Implant System Ltd., Nesher, Israel) (Group I) and 12 screw-retained implant prostheses with computer-assisted design/computer-assisted manufacturing (CAD/CAM) milled zirconia abutment (DentGallop, Houston, TX, USA) (Group II) were connected to their respective implant, and the prosthetic screw was torqued to 30N/cm (Noris). The microspace was evaluated using scanning electron microscopy (SEM; TeScan, Brno, Czech Republic). Twenty-four samples were then induced to cyclic stress (Lokesh Industries, Pune, India) simulating 180 days duration of oral stress. The microspaces (Group IA and Group IIB) were measured post-cyclic stress. Group I and II were again renamed into Group Ia and Group IIb for microbial study. Both implant assemblies were immersed in fresh soybean casein digest broth (SCDB) (Himedia, Mumbai, India) and subsequently inoculated with 1.0µL E. coli suspension (Himedia) at the open end and incubated at 37ºC for seven days. After the incubation period, cellular activity was determined by the spread plate method, and total colony-forming units (CFU) were calculated. The results were evaluated using independent T and Mann-Whitney tests. Result: Average and microspace at the implant-abutment junction of Group I samples in the front right was 12.98µm, center 13.76µm, front left 13.22µm, and in Group II samples, the front right was 18.52µm, center 17.84µm, front left 18.58µm.After being subjected to cyclic loading, the mean levels of the vertical microgap for Group IA samples were: in the front right region 10.37µm, in the center 9.34µm, in the front left 10.51µm and in Group IIB samples front right was 14.59µm, center 13.39µm, front left 13.8µm. Independent t-tests showed insignificant differences between the two groups. The median value of microbial leakage of Group Ia samples after cyclic loading was 30 x 103 CFU/ml, and Group IIb samples were 42 x 103 CFU/ml and were significant. Conclusion: There was minimal variation in the mean microspace between the BioHPP PEEK abutment and CAD/CAM milled zirconia abutment, and it was insignificant before and after cyclic stress. BioHPP PEEK abutment-titanium implant interfaces showed significantly decreased microbial leakage than CAD/CAM milled zirconia abutment-titanium implant interfaces after cyclic stress.
- 7 September 2023
- Published by Springer Nature in Cureus
- Vol. 15  (9) , e44816
Open AccessEscherichia coli Cellular Activity and Frontal Trizonal Evaluation of Microspace Between Implants and Abutments Under Calibrated Cyclic Stress
Aim: To evaluate microspace and microleakage between implant and abutments subjected to pre- and post-calibrated cyclic stress. Materials and methods: Twelve screw-retained implant prostheses with BioHPP polyetheretherketone (PEEK) abutment (Noris Dental Implant System Ltd., Nesher, Israel) (Group I) and 12 screw-retained implant prostheses with computer-assisted design/computer-assisted manufacturing (CAD/CAM) milled zirconia abutment (DentGallop, Houston, TX, USA) (Group II) were connected to their respective implant, and the prosthetic screw was torqued to 30N/cm (Noris). The microspace was evaluated using scanning electron microscopy (SEM; TeScan, Brno, Czech Republic). Twenty-four samples were then induced to cyclic stress (Lokesh Industries, Pune, India) simulating 180 days duration of oral stress. The microspaces (Group IA and Group IIB) were measured post-cyclic stress. Group I and II were again renamed into Group Ia and Group IIb for microbial study. Both implant assemblies were immersed in fresh soybean casein digest broth (SCDB) (Himedia, Mumbai, India) and subsequently inoculated with 1.0µL E. coli suspension (Himedia) at the open end and incubated at 37ºC for seven days. After the incubation period, cellular activity was determined by the spread plate method, and total colony-forming units (CFU) were calculated. The results were evaluated using independent T and Mann-Whitney tests. Result: Average and microspace at the implant-abutment junction of Group I samples in the front right was 12.98µm, center 13.76µm, front left 13.22µm, and in Group II samples, the front right was 18.52µm, center 17.84µm, front left 18.58µm.After being subjected to cyclic loading, the mean levels of the vertical microgap for Group IA samples were: in the front right region 10.37µm, in the center 9.34µm, in the front left 10.51µm and in Group IIB samples front right was 14.59µm, center 13.39µm, front left 13.8µm. Independent t-tests showed insignificant differences between the two groups. The median value of microbial leakage of Group Ia samples after cyclic loading was 30 x 103 CFU/ml, and Group IIb samples were 42 x 103 CFU/ml and were significant. Conclusion: There was minimal variation in the mean microspace between the BioHPP PEEK abutment and CAD/CAM milled zirconia abutment, and it was insignificant before and after cyclic stress. BioHPP PEEK abutment-titanium implant interfaces showed significantly decreased microbial leakage than CAD/CAM milled zirconia abutment-titanium implant interfaces after cyclic stress.
- Open Access
- 7 May 2023
- Published by Springer Nature in Cureus
- Vol. 15  (5) , e38654
Graftless Immediate Dual Implant Anatomic Placement With Immediate Provisional Passive Loading and Definitive Hybrid Crown for the Restoration of Mandibular Molar: A Clinical Report
Immediate implant placement is well-known science and treatment in implant dentistry. It is a multitasking treatment consisting of surgical, prosthodontic, and periodontal aspects, implemented to obtain long-term clinically esthetic and functioning prosthesis. Immediate placement enables clinicians to reduce the number of surgical steps and shorter treatment duration. It has become a standard surgical protocol in modern implant practice. According to existing literature, dual implant placement can be done to avoid any cantilever effect in a single implant and to distribute masticatory forces. This clinical report describes the extraction of an infected mandibular right first molar, (46, Federation Dentaire Internationale) followed by immediate dual placement of dental implants in the rinsed and cleansed sockets. The tooth was atraumatically extracted from the socket, and the latter was prepared to the required depth, and endosseous implants were placed in both the mesial and distal sockets. This atraumatic graft-free operating technique and immediate placement resulted in the preservation of hard and soft tissues. It also increased the patient's comfort, acceptance, and satisfaction due to immediate loading with a provisional removable prosthesis. This was later replaced with a dual screw-retained hybrid implant crown.
- 7 May 2023
- Published by Springer Nature in Cureus
- Vol. 15  (5) , e38654
Open AccessGraftless Immediate Dual Implant Anatomic Placement With Immediate Provisional Passive Loading and Definitive Hybrid Crown for the Restoration of Mandibular Molar: A Clinical Report
Immediate implant placement is well-known science and treatment in implant dentistry. It is a multitasking treatment consisting of surgical, prosthodontic, and periodontal aspects, implemented to obtain long-term clinically esthetic and functioning prosthesis. Immediate placement enables clinicians to reduce the number of surgical steps and shorter treatment duration. It has become a standard surgical protocol in modern implant practice. According to existing literature, dual implant placement can be done to avoid any cantilever effect in a single implant and to distribute masticatory forces. This clinical report describes the extraction of an infected mandibular right first molar, (46, Federation Dentaire Internationale) followed by immediate dual placement of dental implants in the rinsed and cleansed sockets. The tooth was atraumatically extracted from the socket, and the latter was prepared to the required depth, and endosseous implants were placed in both the mesial and distal sockets. This atraumatic graft-free operating technique and immediate placement resulted in the preservation of hard and soft tissues. It also increased the patient's comfort, acceptance, and satisfaction due to immediate loading with a provisional removable prosthesis. This was later replaced with a dual screw-retained hybrid implant crown.
- Open Access
- 30 March 2023
- Published by The Korean Academy of Implant Dentistry in Journal of Dental Implant Research
- Vol. 42  (1) , 7-17
Evaluation of the effects of oral rinses on the retention and surface topography of the ball attachment complex for implant overdentures
Dhanapriya Gopalakrishnan, Azhagarasan Nagarasampatti Sivaprakasam, Vidhya Jeyapalan, Jayakrishnakumar Sampathkumar, Hariharan Ramakrishnan, Vallabh Mahadevan. Journal of Dental Implant Research 2023;42:7-17. https://doi.org/10.54527/jdir.2023.42.1.7
- 30 March 2023
- Published by The Korean Academy of Implant Dentistry in Journal of Dental Implant Research
- Vol. 42  (1) , 7-17
Open AccessEvaluation of the effects of oral rinses on the retention and surface topography of the ball attachment complex for implant overdentures
Dhanapriya Gopalakrishnan, Azhagarasan Nagarasampatti Sivaprakasam, Vidhya Jeyapalan, Jayakrishnakumar Sampathkumar, Hariharan Ramakrishnan, Vallabh Mahadevan. Journal of Dental Implant Research 2023;42:7-17. https://doi.org/10.54527/jdir.2023.42.1.7
- Open Access
- 30 December 2022
- Published by The Korean Academy of Implant Dentistry in Journal of Dental Implant Research
- Vol. 41  (4) , 91-101
Evaluation of accuracy of different elastomeric materials in open tray implant level technique for single tooth impressions
Abinaya Sekar, Saravanakumar Mariappan, Chitra Shankar Krishnan, Jayakrishnakumar Sampathkumar, Hariharan Ramakrishnan, Vallabh Mahadevan, Azhagarasan Nagarasampatti Sivaprakasam. Journal of Dental Implant Research 2022;41:91-101. https://doi.org/10.54527/jdir.2022.41.4.91
- 30 December 2022
- Published by The Korean Academy of Implant Dentistry in Journal of Dental Implant Research
- Vol. 41  (4) , 91-101
Open AccessEvaluation of accuracy of different elastomeric materials in open tray implant level technique for single tooth impressions
Abinaya Sekar, Saravanakumar Mariappan, Chitra Shankar Krishnan, Jayakrishnakumar Sampathkumar, Hariharan Ramakrishnan, Vallabh Mahadevan, Azhagarasan Nagarasampatti Sivaprakasam. Journal of Dental Implant Research 2022;41:91-101. https://doi.org/10.54527/jdir.2022.41.4.91
- Open Access
- 6 November 2022
- Published by Springer Nature in Cureus
- Vol. 14  (11) , e31148
Treatment Intricacies in Mandibular Implant-Supported Rehabilitation of a Patient With Down Syndrome: A Clinical Report
Edentulism is considered a poor health condition and may compromise the quality of life. Prosthodontic replacement of missing teeth results in significant improvement of oral functions. Treating a patient with Down syndrome can pose clinical challenges in handling the emotional aspect as well as in rendering treatment. Careful oral analysis and diagnosis of the existing conditions in such patients will enable and pave the way for clinically acceptable treatment results. This clinical report describes the challenges encountered in the prosthodontic management of an edentulous young patient with Down syndrome.
- 6 November 2022
- Published by Springer Nature in Cureus
- Vol. 14  (11) , e31148
Open AccessTreatment Intricacies in Mandibular Implant-Supported Rehabilitation of a Patient With Down Syndrome: A Clinical Report
Edentulism is considered a poor health condition and may compromise the quality of life. Prosthodontic replacement of missing teeth results in significant improvement of oral functions. Treating a patient with Down syndrome can pose clinical challenges in handling the emotional aspect as well as in rendering treatment. Careful oral analysis and diagnosis of the existing conditions in such patients will enable and pave the way for clinically acceptable treatment results. This clinical report describes the challenges encountered in the prosthodontic management of an edentulous young patient with Down syndrome.
- Open Access
- 1 October 2022
- Published by Acta Scientific Publications Pvt. Ltd. in Acta Scientific Dental Scienecs
- p. 52-66
Evaluation of Different Molding Techniques and Variable Palatal Vaults on the Linear Dimensional Accuracy of Heat Polymerised Acrylic Resin
- 1 October 2022
- Published by Acta Scientific Publications Pvt. Ltd. in Acta Scientific Dental Scienecs
- p. 52-66
Open AccessEvaluation of Different Molding Techniques and Variable Palatal Vaults on the Linear Dimensional Accuracy of Heat Polymerised Acrylic Resin
- Open Access
- 30 June 2022
- Published by The Korean Academy of Implant Dentistry in Journal of Dental Implant Research
- Vol. 41  (2) , 15-24
Evaluation of the effect of EDTA on the antifungal properties, flexural strength, and colour stability of heat polymerised PMMA resin for implant overdentures
- 30 June 2022
- Published by The Korean Academy of Implant Dentistry in Journal of Dental Implant Research
- Vol. 41  (2) , 15-24
Open AccessEvaluation of the effect of EDTA on the antifungal properties, flexural strength, and colour stability of heat polymerised PMMA resin for implant overdentures
- Open Access
- 30 June 2022
- Published by The Korean Academy of Implant Dentistry in Journal of Dental Implant Research
- Vol. 41  (2) , 25-35
Evaluation of machining tolerance and vertical microgaps of biohpp peek and cadcam milled zirconia abutments over titanium implants
- 30 June 2022
- Published by The Korean Academy of Implant Dentistry in Journal of Dental Implant Research
- Vol. 41  (2) , 25-35
Open AccessEvaluation of machining tolerance and vertical microgaps of biohpp peek and cadcam milled zirconia abutments over titanium implants
- 1 June 2022
- Published by JCDR Research and Publications in Journal of Clinical and Diagnostic Research
- Vol. 16  (6) , ZC01-ZC07
Evaluation of Hardness and Fracture Toughness of Feldspathic Porcelain by Various Surface Finishing Techniques
Journal of Clinical and Diagnostic Research aims to publish findings of doctors at grass root level and post graduate students, so that all unique medical experiences are recorded in literature.
- 1 June 2022
- Published by JCDR Research and Publications in Journal of Clinical and Diagnostic Research
- Vol. 16  (6) , ZC01-ZC07
Evaluation of Hardness and Fracture Toughness of Feldspathic Porcelain by Various Surface Finishing Techniques
Journal of Clinical and Diagnostic Research aims to publish findings of doctors at grass root level and post graduate students, so that all unique medical experiences are recorded in literature.