Escherichia coli Cellular Activity and Frontal Trizonal Evaluation of Microspace Between Implants and Abutments Under Calibrated Cyclic Stress
Open Access
- 7 September 2023
- journal article
- research article
- Published by Springer Nature in Cureus
- Vol. 15 (9) , e44816
Abstract
Aim: To evaluate microspace and microleakage between implant and abutments subjected to pre- and post-calibrated cyclic stress. Materials and methods: Twelve screw-retained implant prostheses with BioHPP polyetheretherketone (PEEK) abutment (Noris Dental Implant System Ltd., Nesher, Israel) (Group I) and 12 screw-retained implant prostheses with computer-assisted design/computer-assisted manufacturing (CAD/CAM) milled zirconia abutment (DentGallop, Houston, TX, USA) (Group II) were connected to their respective implant, and the prosthetic screw was torqued to 30N/cm (Noris). The microspace was evaluated using scanning electron microscopy (SEM; TeScan, Brno, Czech Republic). Twenty-four samples were then induced to cyclic stress (Lokesh Industries, Pune, India) simulating 180 days duration of oral stress. The microspaces (Group IA and Group IIB) were measured post-cyclic stress. Group I and II were again renamed into Group Ia and Group IIb for microbial study. Both implant assemblies were immersed in fresh soybean casein digest broth (SCDB) (Himedia, Mumbai, India) and subsequently inoculated with 1.0µL E. coli suspension (Himedia) at the open end and incubated at 37ºC for seven days. After the incubation period, cellular activity was determined by the spread plate method, and total colony-forming units (CFU) were calculated. The results were evaluated using independent T and Mann-Whitney tests. Result: Average and microspace at the implant-abutment junction of Group I samples in the front right was 12.98µm, center 13.76µm, front left 13.22µm, and in Group II samples, the front right was 18.52µm, center 17.84µm, front left 18.58µm.After being subjected to cyclic loading, the mean levels of the vertical microgap for Group IA samples were: in the front right region 10.37µm, in the center 9.34µm, in the front left 10.51µm and in Group IIB samples front right was 14.59µm, center 13.39µm, front left 13.8µm. Independent t-tests showed insignificant differences between the two groups. The median value of microbial leakage of Group Ia samples after cyclic loading was 30 x 103 CFU/ml, and Group IIb samples were 42 x 103 CFU/ml and were significant. Conclusion: There was minimal variation in the mean microspace between the BioHPP PEEK abutment and CAD/CAM milled zirconia abutment, and it was insignificant before and after cyclic stress. BioHPP PEEK abutment-titanium implant interfaces showed significantly decreased microbial leakage than CAD/CAM milled zirconia abutment-titanium implant interfaces after cyclic stress.Keywords
This publication has 26 references indexed in Scilit:
- Determination of fluid leakages in the different screw-retained implant-abutment connections in a mechanical artificial mouthJournal of Materials Science: Materials in Medicine, 2015
- Correlation between microleakage and screw loosening at implant-abutment connectionThe Journal of Advanced Prosthodontics, 2014
- Evaluation of Microgap Size and Microbial Leakage in the Connection Area of 4 Abutments With Straumann (ITI) ImplantJournal of Oral Implantology, 2012
- Titanium as a Reconstruction and Implant Material in Dentistry: Advantages and PitfallsMaterials, 2012
- Effects of different implant–abutment connections on micromotion and stress distribution: Prediction of microgap formationJournal of Dentistry, 2012
- Comparison of Fit Accuracy between Procera® Custom Abutments and Three Implant SystemsClinical Implant Dentistry and Related Research, 2010
- A systematic review of the 5‐year survival and complication rates of implant‐supported single crownsClinical Oral Implants Research, 2007
- Cyclic loading of implant-supported prostheses: Changes in component fit over timeThe Journal of Prosthetic Dentistry, 2003
- Influence of the Size of the Microgap on Crestal Bone Changes Around Titanium Implants. A Histometric Evaluation of Unloaded Non‐Submerged Implants in the Canine MandibleJournal of Periodontology, 2001