Gamze Emir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gamze Emir has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Yusuf Dilgin
Çanakkale Onsekiz Mart Üniversites - Terzioğlu Kampüsü: Canakkale Onsekiz Mart Universitesi
2 shared publications- Yusuf Dilgin
Department of Chemistry, Faculty of Science, Çanakkale Onsekiz Mart University, Çanakkale, Türkiye
2 shared publications - Cahit Akgul
Faculty of Arts and Sciences, Department of Chemistry, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
1 shared publication Cahit Akgül
Çanakkale Onsekiz Mart Üniversites - Terzioğlu Kampüsü: Canakkale Onsekiz Mart Universitesi
1 shared publication- Reşat Apak
Faculty of Engineering, Department of Chemistry, Istanbul University-Cerrahpaşa, Istanbul, Türkiye
1 shared publication Samet Sahin
Lancaster University
1 shared publication
Latest Publications
- 27 September 2024
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 197 (2) , 910-925
A Self-Powered Enzymatic Glucose Sensor Utilizing Bimetallic Nanoparticle Composites Modified Pencil Graphite Electrodes as Cathode
Enzymatic biofuel cells (EBFC) are promising sources of green energy owing to the benefits of using renewable biofuels, eco-friendly biocatalysts, and moderate operating conditions. In this study, a simple and effective EBFC was presented using an enzymatic composite material-based anode and a nonenzymatic bimetallic nanoparticle-based cathode respectively. The anode was constructed from a glassy carbon electrode (GCE) modified with a multi-walled carbon nanotube (MWCNT) and ferrocene (Fc) as a conductive layer coupled with the enzyme glucose oxidase (GOx) as a sensitive detection layer for glucose. A chitosan layer was also applied to the electrode as a protective layer to complete the composite anode. Chronoamperometry (CA) results show that the MWCNT-Fc-GOx/GCE electrode has a linear relationship between current and glucose concentration, which varied from 1 to 10 mM. The LOD and LOQ were calculated for anode as 0.26 mM and 0.87 mM glucose, respectively. Also the sensitivity of the proposed sensor was calculated as 25.71 \(\mu\)A/mM. Moreover, the studies of some potential interferants show that there is no significant interference for anode in the determination of glucose except ascorbic acid (AA), uric acid (UA), and dopamine (DA). On the other hand, the cathode consisted of a disposable pencil graphite electrode (PGE) modified with platinum-palladium bimetallic nanoparticles (Nps) which exhibit excellent conductivity and electron transfer rate for the oxygen reduction reaction (ORR). The constructed EBFC was optimized and characterized using various electroanalytical techniques. The EBFC consisting of MWCNT-Fc-GOx/GCE anode and Pt-PdNps/PGE cathode exhibits an open circuit potential of 285.0 mV and a maximum power density of 32.25 µW cm−2 under optimized conditions. The results show that the proposed EBFC consisting of an enzymatic composite-based anode and bimetallic nanozyme-based cathode is a unique design and a promising candidate for detecting glucose while harvesting power from glucose-containing natural or artificial fluids. Graphical Abstract- 27 September 2024
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 197 (2) , 910-925
A Self-Powered Enzymatic Glucose Sensor Utilizing Bimetallic Nanoparticle Composites Modified Pencil Graphite Electrodes as Cathode
Enzymatic biofuel cells (EBFC) are promising sources of green energy owing to the benefits of using renewable biofuels, eco-friendly biocatalysts, and moderate operating conditions. In this study, a simple and effective EBFC was presented using an enzymatic composite material-based anode and a nonenzymatic bimetallic nanoparticle-based cathode respectively. The anode was constructed from a glassy carbon electrode (GCE) modified with a multi-walled carbon nanotube (MWCNT) and ferrocene (Fc) as a conductive layer coupled with the enzyme glucose oxidase (GOx) as a sensitive detection layer for glucose. A chitosan layer was also applied to the electrode as a protective layer to complete the composite anode. Chronoamperometry (CA) results show that the MWCNT-Fc-GOx/GCE electrode has a linear relationship between current and glucose concentration, which varied from 1 to 10 mM. The LOD and LOQ were calculated for anode as 0.26 mM and 0.87 mM glucose, respectively. Also the sensitivity of the proposed sensor was calculated as 25.71 \(\mu\)A/mM. Moreover, the studies of some potential interferants show that there is no significant interference for anode in the determination of glucose except ascorbic acid (AA), uric acid (UA), and dopamine (DA). On the other hand, the cathode consisted of a disposable pencil graphite electrode (PGE) modified with platinum-palladium bimetallic nanoparticles (Nps) which exhibit excellent conductivity and electron transfer rate for the oxygen reduction reaction (ORR). The constructed EBFC was optimized and characterized using various electroanalytical techniques. The EBFC consisting of MWCNT-Fc-GOx/GCE anode and Pt-PdNps/PGE cathode exhibits an open circuit potential of 285.0 mV and a maximum power density of 32.25 µW cm−2 under optimized conditions. The results show that the proposed EBFC consisting of an enzymatic composite-based anode and bimetallic nanozyme-based cathode is a unique design and a promising candidate for detecting glucose while harvesting power from glucose-containing natural or artificial fluids. Graphical Abstract- Open Access
- 30 May 2024
- Published by Springer Nature in Research Square
A Self-Powered Enzymatic Glucose Sensor Utilizing Bimetallic Nanoparticle Composites Modified Pencil Graphite Electrodes as Cathode
Enzymatic biofuel cells (EBFC) are promising sources of green energy owing to the benefits of using renewable biofuels, eco-friendly biocatalysts, and moderate operating conditions. In this study, a simple and effective EBFC was presented using an enzymatic composite material-based anode and a nonenzymatic bimetallic nanoparticle-based cathode, respectively. The anode was constructed from a glassy carbon electrode (GCE) modified with a multi-walled carbon nanotube (MWCNT) and ferrocene (Fc) as a conductive layer coupled with the enzyme glucose oxidase (GOx) as a sensitive detection layer for glucose. A chitosan layer was also applied to the electrode as a protective layer to complete the composite anode. On the other hand, the cathode consisted of a disposable pencil graphite electrode (PGE) modified with platinum-palladium bimetallic nanoparticles (Nps) which exhibit excellent conductivity and electron transfer rate for the oxygen reduction reaction. The EBFC consisting of MWCNT-Fc-GOx/GCE anode and Pt-PdNps/PGE cathode exhibits an open circuit potential of 285 mV and a maximum power density of 32.25 µW cm− 2 under optimized conditions. The results show that the proposed EBFC is a promising candidate for detecting glucose while harvesting power from artificial serum samples.
- 30 May 2024
- Published by Springer Nature in Research Square
Open AccessA Self-Powered Enzymatic Glucose Sensor Utilizing Bimetallic Nanoparticle Composites Modified Pencil Graphite Electrodes as Cathode
Enzymatic biofuel cells (EBFC) are promising sources of green energy owing to the benefits of using renewable biofuels, eco-friendly biocatalysts, and moderate operating conditions. In this study, a simple and effective EBFC was presented using an enzymatic composite material-based anode and a nonenzymatic bimetallic nanoparticle-based cathode, respectively. The anode was constructed from a glassy carbon electrode (GCE) modified with a multi-walled carbon nanotube (MWCNT) and ferrocene (Fc) as a conductive layer coupled with the enzyme glucose oxidase (GOx) as a sensitive detection layer for glucose. A chitosan layer was also applied to the electrode as a protective layer to complete the composite anode. On the other hand, the cathode consisted of a disposable pencil graphite electrode (PGE) modified with platinum-palladium bimetallic nanoparticles (Nps) which exhibit excellent conductivity and electron transfer rate for the oxygen reduction reaction. The EBFC consisting of MWCNT-Fc-GOx/GCE anode and Pt-PdNps/PGE cathode exhibits an open circuit potential of 285 mV and a maximum power density of 32.25 µW cm− 2 under optimized conditions. The results show that the proposed EBFC is a promising candidate for detecting glucose while harvesting power from artificial serum samples.
- Open Access
- 31 August 2020
- Published by The Korean Electrochemical Society - English Journal in Journal of Electrochemical Science and Technology
- Vol. 11 (3) , 248-256
Pyrocatechol Violet Modified Graphite Pencil Electrode for Flow Injection Amperometric Determination of Sulfide
- 31 August 2020
- Published by The Korean Electrochemical Society - English Journal in Journal of Electrochemical Science and Technology
- Vol. 11 (3) , 248-256
Open AccessPyrocatechol Violet Modified Graphite Pencil Electrode for Flow Injection Amperometric Determination of Sulfide
- 12 December 2019
- Published by Wiley in ChemElectroChem
- Vol. 7 (3) , 649-658
A New Redox Mediator (Cupric‐Neocuproine Complex)‐ Modified Pencil Graphite Electrode for the Electrocatalytic Oxidation of H 2 O 2 : A Flow Injection Amperometric Sensor
This paper introduces the cupric‐neocuproine complex ([Cu(Nc) 2 ] 2+ ) as a new redox mediator for the electrocatalytic oxidation of H 2 O 2 . For this purpose, [Cu(Nc) 2 ] 2+ was modified onto a disposable pencil graphite electrode (PGE) surface by using Nafion (Nf) as a cation‐exchange membrane for the effective adsorption of complex. The modified electrode was prepared by immersing Nf‐adsorbed PGE into [Cu(Nc) 2 ] 2+ complex solution (0.40 mM of Cu 2+ and 0.80 mM of Nc prepared at pH 4.76 in 0.10 M acetate buffer). SEM images and EDX spectra of electrodes were presented for the elucidation of their surface morphologies. Cyclic voltammetric results showed that H 2 O 2 was electrocatalytically oxidized at [Cu(Nc) 2 ] 2+ /Nf/PGE, because both the increase in current and the potential shift to a more negative direction were observed for oxidation of H 2 O 2 at [Cu(Nc) 2 ] 2+ /Nf/PGE in comparison to bare PGE. Then, the electrocatalytic activity of [Cu(Nc) 2 ] 2+ /Nf/PGE toward H 2 O 2 oxidation was utilized for amperometric determination of H 2 O 2 in flow injection analysis (FIA) system. Flow injection (FI) amperometric studies showed two linear calibration ranges (1.0‐1000.0 μM ( R 2 =0.9958) and 1000.0‐10000.0 μM ( R 2 =0.9902) with a detection limit of 0.4 μM H 2 O 2 which is considered good for electroanalytical determinations, especially for electrocatalytic oxidation. To test the applicability of the developed FI amperometric hydrogen peroxide sensor, H 2 O 2 contents of some relevant samples were determined.
- 12 December 2019
- Published by Wiley in ChemElectroChem
- Vol. 7 (3) , 649-658
A New Redox Mediator (Cupric‐Neocuproine Complex)‐ Modified Pencil Graphite Electrode for the Electrocatalytic Oxidation of H 2 O 2 : A Flow Injection Amperometric Sensor
This paper introduces the cupric‐neocuproine complex ([Cu(Nc) 2 ] 2+ ) as a new redox mediator for the electrocatalytic oxidation of H 2 O 2 . For this purpose, [Cu(Nc) 2 ] 2+ was modified onto a disposable pencil graphite electrode (PGE) surface by using Nafion (Nf) as a cation‐exchange membrane for the effective adsorption of complex. The modified electrode was prepared by immersing Nf‐adsorbed PGE into [Cu(Nc) 2 ] 2+ complex solution (0.40 mM of Cu 2+ and 0.80 mM of Nc prepared at pH 4.76 in 0.10 M acetate buffer). SEM images and EDX spectra of electrodes were presented for the elucidation of their surface morphologies. Cyclic voltammetric results showed that H 2 O 2 was electrocatalytically oxidized at [Cu(Nc) 2 ] 2+ /Nf/PGE, because both the increase in current and the potential shift to a more negative direction were observed for oxidation of H 2 O 2 at [Cu(Nc) 2 ] 2+ /Nf/PGE in comparison to bare PGE. Then, the electrocatalytic activity of [Cu(Nc) 2 ] 2+ /Nf/PGE toward H 2 O 2 oxidation was utilized for amperometric determination of H 2 O 2 in flow injection analysis (FIA) system. Flow injection (FI) amperometric studies showed two linear calibration ranges (1.0‐1000.0 μM ( R 2 =0.9958) and 1000.0‐10000.0 μM ( R 2 =0.9902) with a detection limit of 0.4 μM H 2 O 2 which is considered good for electroanalytical determinations, especially for electrocatalytic oxidation. To test the applicability of the developed FI amperometric hydrogen peroxide sensor, H 2 O 2 contents of some relevant samples were determined.