Farzaneh Raji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Farzaneh Raji has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Ioannis Zisis
Florida International Univ
4 shared publications - Amir Naeiji
PhD Student, Department of Civil and Environmental Engineering, Florida International University, 10555 W. Flagler Street, EC 3680, Miami, FL 33174
2 shared publications - Jean-Paul Pinelli
Professor, Dept. of Civil Engineering, Florida Institute of Technology, 203 Olin Engineering Complex, 150 W. University Blvd., Melbourne, FL 32901
2 shared publications Adel Abdelnaby
1 shared publicationAmir Naeiji
PhD Graduate, Sigma Engineering Solutions, Las Vegas, Nevada
1 shared publicationAnteneh Yohannes
1 shared publication
Latest Publications
- 1 July 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 146 (7) , 04020114
Experimental Investigation of Wind-Driven Rain Propagation in a Building Interior
Posthurricane surveys have shown that building interior damage often results from water intrusion into the building interior. The interior damage can make up 50%–100% of the total building loss; therefore, its accurate evaluation and quantification are necessary for estimation of hurricane losses. In this research, water propagation into a building’s interior was experimentally investigated. Large-scale building models with gable and hip roofs were tested for three exterior damage states. The results showed that for the light damage state, the very small area of the roof and wall defects and breaches does not allow wind circulation inside the building, and as a result, the rain affected only localized areas with defects. However, for the more severe damage states, the areas of breaches were large enough to allow wind circulation inside the building, and the water propagation path is highly affected by the internal wind flow. The findings from the current study can be implemented in hurricane loss models and improve their accuracy by estimating the water distribution inside the building.
- 1 July 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 146 (7) , 04020114
Experimental Investigation of Wind-Driven Rain Propagation in a Building Interior
Posthurricane surveys have shown that building interior damage often results from water intrusion into the building interior. The interior damage can make up 50%–100% of the total building loss; therefore, its accurate evaluation and quantification are necessary for estimation of hurricane losses. In this research, water propagation into a building’s interior was experimentally investigated. Large-scale building models with gable and hip roofs were tested for three exterior damage states. The results showed that for the light damage state, the very small area of the roof and wall defects and breaches does not allow wind circulation inside the building, and as a result, the rain affected only localized areas with defects. However, for the more severe damage states, the areas of breaches were large enough to allow wind circulation inside the building, and the water propagation path is highly affected by the internal wind flow. The findings from the current study can be implemented in hurricane loss models and improve their accuracy by estimating the water distribution inside the building.
- Open Access
- 27 April 2019
- Published by Ital Publication in Civil Engineering Journal
- Vol. 5 (4) , 759-766
Performance of Concrete MRF at Near-Field Earthquakes Compared to Far-Field Earthquakes
The characteristic of near-field earthquake records has been investigated in the previous studies. However, the effects of the near-field earthquakes on the response of the building structures need to be further investigated. Engineering demand parameters like inter-story drift ratio and floor acceleration can provide a good means for comparing the response of structures to the near-field and the far-field earthquakes. The main objective of this paper was to apply these two parameters to compare the behavior of the concrete Moment Resistant Frame (MRF) subjected to near-field and far-field ground motions. In this study, non-linear numerical simulations were performed on concrete MRF office buildings subjected to two sets of 14 near-field records and 14 far-field records. The analytical models simulated 4-story, 8-story, and 16 story buildings. The obtained results indicated that the near-field effects can increase the inter-story drift ratio and floor acceleration at lower stories of low and mid-rise building subjected to high ground motion intensities.
- 27 April 2019
- Published by Ital Publication in Civil Engineering Journal
- Vol. 5 (4) , 759-766
Open AccessPerformance of Concrete MRF at Near-Field Earthquakes Compared to Far-Field Earthquakes
The characteristic of near-field earthquake records has been investigated in the previous studies. However, the effects of the near-field earthquakes on the response of the building structures need to be further investigated. Engineering demand parameters like inter-story drift ratio and floor acceleration can provide a good means for comparing the response of structures to the near-field and the far-field earthquakes. The main objective of this paper was to apply these two parameters to compare the behavior of the concrete Moment Resistant Frame (MRF) subjected to near-field and far-field ground motions. In this study, non-linear numerical simulations were performed on concrete MRF office buildings subjected to two sets of 14 near-field records and 14 far-field records. The analytical models simulated 4-story, 8-story, and 16 story buildings. The obtained results indicated that the near-field effects can increase the inter-story drift ratio and floor acceleration at lower stories of low and mid-rise building subjected to high ground motion intensities.
- Open Access
- 1 December 2018
- Published by Walter de Gruyter GmbH in Journal of Applied Engineering Sciences
- Vol. 8 (2) , 35-40
Effects of Fly Ash on Mechanical Properties of Concrete
Cement is a common and widespread building material over the world. Similarly, carbon dioxide emissions have been significantly increased due to cement production. Alternative low-carbon binders rather than cement have been progressively sought in recent years. Fly ash was found as an available option, since it is being largely disposed annually as a waste material. In this research several studies have been reviewed and recent applications of fly ash on concrete specification, including strength and fracture toughness of green concrete have been perused. Furthermore, transport properties of high volume fly ash after exposure to high temperature and influence of curing temperature on strength development of fly ash-recycled concrete aggregate blends have been investigated. The investigated test results showed that the properties of composites incorporating fly ash depend on the age of the concrete. Test results also revealed that transport properties of concrete increased notably after exposure to 400cº and the results achieved on fly ash-recycled concrete aggregate led to the conclusion that 15% FA is the optimum blend for road stabilization applications.
- 1 December 2018
- Published by Walter de Gruyter GmbH in Journal of Applied Engineering Sciences
- Vol. 8 (2) , 35-40
Open AccessEffects of Fly Ash on Mechanical Properties of Concrete
Cement is a common and widespread building material over the world. Similarly, carbon dioxide emissions have been significantly increased due to cement production. Alternative low-carbon binders rather than cement have been progressively sought in recent years. Fly ash was found as an available option, since it is being largely disposed annually as a waste material. In this research several studies have been reviewed and recent applications of fly ash on concrete specification, including strength and fracture toughness of green concrete have been perused. Furthermore, transport properties of high volume fly ash after exposure to high temperature and influence of curing temperature on strength development of fly ash-recycled concrete aggregate blends have been investigated. The investigated test results showed that the properties of composites incorporating fly ash depend on the age of the concrete. Test results also revealed that transport properties of concrete increased notably after exposure to 400cº and the results achieved on fly ash-recycled concrete aggregate led to the conclusion that 15% FA is the optimum blend for road stabilization applications.
- 1 September 2017
- Published by Elsevier in Journal of Wind Engineering and Industrial Aerodynamics
- Vol. 168, 228-246
Wind loads on residential scale rooftop photovoltaic panels
- 1 September 2017
- Published by Elsevier in Journal of Wind Engineering and Industrial Aerodynamics
- Vol. 168, 228-246
Wind loads on residential scale rooftop photovoltaic panels
- 1 March 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 23 (1)
Large-Scale Wind Tunnel Tests of Canopies Attached to Low-Rise Buildings
Canopies attached to residential and other buildings are predominantly lightweight structures with both surfaces exposed to the wind; therefore, their design is mostly governed by wind-induced loads. Currently, only limited information exists for the design of attached canopies against wind action in building codes and wind standards, which justifies the need to further investigate the wind effects on these structures to establish reliable design recommendations. The pressure distribution on the canopy surfaces, as well as the net component, is highly affected by the wind field around the canopy; therefore, its dimensions, location, and wind direction need to be considered. To investigate the effects of these parameters, in this study, a set of six 1:6 scaled model configurations of a low-rise building with different attached canopy dimensions and locations were tested at boundary-layer flow in the Wall of Wind Research Facility at Florida International University. The results are presented as loc...
- 1 March 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Architectural Engineering
- Vol. 23 (1)
Large-Scale Wind Tunnel Tests of Canopies Attached to Low-Rise Buildings
Canopies attached to residential and other buildings are predominantly lightweight structures with both surfaces exposed to the wind; therefore, their design is mostly governed by wind-induced loads. Currently, only limited information exists for the design of attached canopies against wind action in building codes and wind standards, which justifies the need to further investigate the wind effects on these structures to establish reliable design recommendations. The pressure distribution on the canopy surfaces, as well as the net component, is highly affected by the wind field around the canopy; therefore, its dimensions, location, and wind direction need to be considered. To investigate the effects of these parameters, in this study, a set of six 1:6 scaled model configurations of a low-rise building with different attached canopy dimensions and locations were tested at boundary-layer flow in the Wall of Wind Research Facility at Florida International University. The results are presented as loc...
- 17 April 2015
- Published by American Society of Civil Engineers (ASCE)
- p. 1868-1878
Large-Scale Wind Testing of Photovoltaic Panels Mounted on Residential Roofs
- 17 April 2015
- Published by American Society of Civil Engineers (ASCE)
- p. 1868-1878
Large-Scale Wind Testing of Photovoltaic Panels Mounted on Residential Roofs