Gert Van Gompel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gert Van Gompel has a total of 124 co-authors. Here are the top co-authors by number of shared publications:
- Nico Buls
Department of Radiology, Research Centre For Digital Medicine (REDM), Universitair Ziekenhuis Brussel (UZ Brussel), Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels, Belgium
22 shared publications Johan de Mey
Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Department of Radiology Brussels Belgium
11 shared publications- Jef Vandemeulebroucke
Department of Electronics and Informatics (ETRO) Vrije Universiteit Brussel Brussels Belgium
6 shared publications - Johan De Mey
Department of Radiology, Universitair Ziekenhuis Brussel, Brussels, Belgium
6 shared publications - Jan Sijbers
Imec-Vision Lab, Department of Physics, University of Antwerp, Wilrijk, Belgium
4 shared publications Koenraad H. Nieboer
Departement of Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussels (UZ Brussel), Laarbeeklaan 101, 1090, Brussels, Belgium
4 shared publications
Latest Publications
- Open Access
- 19 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (20) , 3396
Dynamic Xenon-Enhanced Spectral CT Imaging to Evaluate Regional Lung Function in an In Vivo Rabbit Model
Background/Objectives: Pulmonary diseases exhibit spatially heterogeneous functional and structural abnormalities that are inadequately represented by conventional lung function testing. This pilot study investigates dynamic xenon-enhanced dual-energy CT (Xe-DECT) for a multiparametric assessment of lung ventilation and tissue. Methods: Four mechanically ventilated rabbits were scanned during washout of 70% xenon in oxygen using multibreath imaging with a clinical DECT both before (baseline) and after methacholine administration (post-MCh). Tracheal Xe concentration (CXe) and flow were monitored using mass spectrometry and pneumotachometry to estimate specific ventilation () and end-expiratory lung volume (EELVms). DECT-derived xenon concentration and tissue density images (mg/mL) were obtained by material decomposition, yielding and EELVDECT, respectively. Agreement with mass spectrometry and differences between baseline and post-MCh were assessed. Results: The baseline and EELVDECT agreed with the mass spectrometry, with mean differences of 0.6 min−1 [−0.2 min−1, 1.4 min−1] and 0.6 mL [−6.7 mL, 7.9 mL], respectively. Following MCh administration, the mean differences increased to −2.9 min−1 [−4.1 min−1, −1.6 min−1] for and 1.3 mL [−15.3 mL, 12.8 mL] for EELV. Post-MCh, decreased from 8.6 ± 1.6 min−1 to 3.7 ± 0.9 min−1 (p = 0.034) and EELVDECT from 29.3 ± 1.0 mL to 27.0 ± 1.3 mL (p = 0.036), whereas (p = 0.308) and EELVms (p = 0.653) showed no substantial changes. Regional analysis revealed that in well-ventilated regions matched tracheal . Conclusions: Dynamic Xe-DECT imaging enabled spatial and quantitative assessments of specific ventilation and tissue densities in an in vivo rabbit model. This technique allowed detection of focal alterations that remained undetected by tracheal measurements.- 19 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (20) , 3396
Open AccessDynamic Xenon-Enhanced Spectral CT Imaging to Evaluate Regional Lung Function in an In Vivo Rabbit Model
Background/Objectives: Pulmonary diseases exhibit spatially heterogeneous functional and structural abnormalities that are inadequately represented by conventional lung function testing. This pilot study investigates dynamic xenon-enhanced dual-energy CT (Xe-DECT) for a multiparametric assessment of lung ventilation and tissue. Methods: Four mechanically ventilated rabbits were scanned during washout of 70% xenon in oxygen using multibreath imaging with a clinical DECT both before (baseline) and after methacholine administration (post-MCh). Tracheal Xe concentration (CXe) and flow were monitored using mass spectrometry and pneumotachometry to estimate specific ventilation () and end-expiratory lung volume (EELVms). DECT-derived xenon concentration and tissue density images (mg/mL) were obtained by material decomposition, yielding and EELVDECT, respectively. Agreement with mass spectrometry and differences between baseline and post-MCh were assessed. Results: The baseline and EELVDECT agreed with the mass spectrometry, with mean differences of 0.6 min−1 [−0.2 min−1, 1.4 min−1] and 0.6 mL [−6.7 mL, 7.9 mL], respectively. Following MCh administration, the mean differences increased to −2.9 min−1 [−4.1 min−1, −1.6 min−1] for and 1.3 mL [−15.3 mL, 12.8 mL] for EELV. Post-MCh, decreased from 8.6 ± 1.6 min−1 to 3.7 ± 0.9 min−1 (p = 0.034) and EELVDECT from 29.3 ± 1.0 mL to 27.0 ± 1.3 mL (p = 0.036), whereas (p = 0.308) and EELVms (p = 0.653) showed no substantial changes. Regional analysis revealed that in well-ventilated regions matched tracheal . Conclusions: Dynamic Xe-DECT imaging enabled spatial and quantitative assessments of specific ventilation and tissue densities in an in vivo rabbit model. This technique allowed detection of focal alterations that remained undetected by tracheal measurements. - Open Access
- 12 February 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3) , 035023
Regional ventilation imaging in normal and bronchoconstricted in vivo rabbit lungs using dynamic shuttle mode Xe-enhanced DECT imaging
Objective. To investigate dynamic shuttle-mode xenon (Xe)-enhanced dual-energy CT (Xe-DECT) imaging for a regional assessment of ventilation in in vivo rabbit lungs. Approach. Four mechanically ventilated rabbits were scanned during the washout of a 70% xenon in 30% oxygen gas mixture using dynamic shuttle-mode DECT at baseline and during methacholine (MCh)-induced bronchoconstriction (post-MCh). Material decomposition was applied to generate xenon and tissue density images (mg ml −1 ). A tissue-based correction was used to isolate the xenon concentration ( C Xe ) in the gas phase of the xenon density images. The resultant C Xe images were used to investigate regional ventilation defects (VDs) by comparing the VD fraction (VDF, expressed as percentage) between baseline and post-MCh conditions. Additionally, regional ventilation efficiency within the VDs and surrounding (non-VD) areas was quantified as specific ventilation ( s V ˙ in min −1 ). Ventilation was also qualitatively assessed by evaluating ventilation distributions during washout. Main results. MCh-induced bronchoconstriction resulted in an increase in VDF. The average VDF at baseline was 13.8 ± 8.5%, compared to an average post-MCh VDF of 29.6 ± 7.7%, p = 0.026. The VDs at baseline did not reveal a reduced ventilation efficiency ( s V ˙ V D : 8.4 ± 2.7 min −1 ), compared to non-VD areas ( s V ˙ n o n − V D : 7.0 ± 3.1 min −1 ), p = 0.306. In contrast, MCh-induced VDs were found to have a reduced ventilation efficiency ( s V ˙ V D : 4.9 ± 2.3 min −1 ), compared to non-VD areas ( s V ˙ n o n − V D : 6.4 ± 2.3 min −1 ), p = 0.004 . Significance. Dynamic shuttle-mode Xe-DECT during washout enabled regional evaluation of ventilation in healthy and pathological in vivo rabbit lungs. As traditional lung function tests offer only global assessments of respiratory impairment, there is a growing interest in pulmonary functional imaging to enable quantitative evaluation of regional lung function.
- 12 February 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3) , 035023
Open AccessRegional ventilation imaging in normal and bronchoconstricted in vivo rabbit lungs using dynamic shuttle mode Xe-enhanced DECT imaging
Objective. To investigate dynamic shuttle-mode xenon (Xe)-enhanced dual-energy CT (Xe-DECT) imaging for a regional assessment of ventilation in in vivo rabbit lungs. Approach. Four mechanically ventilated rabbits were scanned during the washout of a 70% xenon in 30% oxygen gas mixture using dynamic shuttle-mode DECT at baseline and during methacholine (MCh)-induced bronchoconstriction (post-MCh). Material decomposition was applied to generate xenon and tissue density images (mg ml −1 ). A tissue-based correction was used to isolate the xenon concentration ( C Xe ) in the gas phase of the xenon density images. The resultant C Xe images were used to investigate regional ventilation defects (VDs) by comparing the VD fraction (VDF, expressed as percentage) between baseline and post-MCh conditions. Additionally, regional ventilation efficiency within the VDs and surrounding (non-VD) areas was quantified as specific ventilation ( s V ˙ in min −1 ). Ventilation was also qualitatively assessed by evaluating ventilation distributions during washout. Main results. MCh-induced bronchoconstriction resulted in an increase in VDF. The average VDF at baseline was 13.8 ± 8.5%, compared to an average post-MCh VDF of 29.6 ± 7.7%, p = 0.026. The VDs at baseline did not reveal a reduced ventilation efficiency ( s V ˙ V D : 8.4 ± 2.7 min −1 ), compared to non-VD areas ( s V ˙ n o n − V D : 7.0 ± 3.1 min −1 ), p = 0.306. In contrast, MCh-induced VDs were found to have a reduced ventilation efficiency ( s V ˙ V D : 4.9 ± 2.3 min −1 ), compared to non-VD areas ( s V ˙ n o n − V D : 6.4 ± 2.3 min −1 ), p = 0.004 . Significance. Dynamic shuttle-mode Xe-DECT during washout enabled regional evaluation of ventilation in healthy and pathological in vivo rabbit lungs. As traditional lung function tests offer only global assessments of respiratory impairment, there is a growing interest in pulmonary functional imaging to enable quantitative evaluation of regional lung function.
- Open Access
- 25 April 2023
- Published by Springer Nature in European Radiology Experimental
- Vol. 7 (1) , 1-10
Stent appearance in a novel silicon-based photon-counting CT prototype: ex vivo phantom study in head-to-head comparison with conventional energy-integrating CT
Background: In this study, stent appearance in a novel silicon-based photon-counting computed tomography (Si-PCCT) prototype was compared with a conventional energy-integrating detector CT (EIDCT) system. Methods: An ex vivo phantom was created, consisting of a 2% agar-water mixture, in which human-resected and stented arteries were individually embedded. Using similar technique parameters, helical scan data was acquired using a novel prototype Si-PCCT and a conventional EIDCT system at a volumetric CT dose index (CTDIvol) of 9 mGy. Reconstructions were made at 502 and 1502 mm2 field-of-views (FOVs) using a bone kernel and adaptive statistical iterative reconstruction with 0% blending. Using a 5-point Likert scale, reader evaluations were performed on stent appearance, blooming and inter-stent visibility. Quantitative image analysis was performed on stent diameter accuracy, blooming and inter-stent distinction. Qualitative and quantitative differences between Si-PCCT and EIDCT systems were tested with a Wilcoxon signed-rank test and a paired samples t-test, respectively. Inter- and intra-reader agreement was assessed using the intraclass correlation coefficient (ICC). Results: Qualitatively, Si-PCCT images were rated higher than EIDCT images at 150-mm FOV, based on stent appearance (p = 0.026) and blooming (p = 0.015), with a moderate inter- (ICC = 0.50) and intra-reader (ICC = 0.60) agreement. Quantitatively, Si-PCCT yielded more accurate diameter measurements (p = 0.001), reduced blooming (p < 0.001) and improved inter-stent distinction (p < 0.001). Similar trends were observed for the images reconstructed at 50-mm FOV. Conclusions: When compared to EIDCT, the improved spatial resolution of Si-PCCT yields enhanced stent appearance, more accurate diameter measurements, reduced blooming and improved inter-stent distinction. Key points: • This study evaluated stent appearance in a novel silicon-based photon-counting computed tomography (Si-PCCT) prototype. • Compared to standard CT, Si-PCCT resulted in more accurate stent diameter measurements. • Si-PCCT also reduced blooming artefacts and improved inter-stent visibility.
- 25 April 2023
- Published by Springer Nature in European Radiology Experimental
- Vol. 7 (1) , 1-10
Open AccessStent appearance in a novel silicon-based photon-counting CT prototype: ex vivo phantom study in head-to-head comparison with conventional energy-integrating CT
Background: In this study, stent appearance in a novel silicon-based photon-counting computed tomography (Si-PCCT) prototype was compared with a conventional energy-integrating detector CT (EIDCT) system. Methods: An ex vivo phantom was created, consisting of a 2% agar-water mixture, in which human-resected and stented arteries were individually embedded. Using similar technique parameters, helical scan data was acquired using a novel prototype Si-PCCT and a conventional EIDCT system at a volumetric CT dose index (CTDIvol) of 9 mGy. Reconstructions were made at 502 and 1502 mm2 field-of-views (FOVs) using a bone kernel and adaptive statistical iterative reconstruction with 0% blending. Using a 5-point Likert scale, reader evaluations were performed on stent appearance, blooming and inter-stent visibility. Quantitative image analysis was performed on stent diameter accuracy, blooming and inter-stent distinction. Qualitative and quantitative differences between Si-PCCT and EIDCT systems were tested with a Wilcoxon signed-rank test and a paired samples t-test, respectively. Inter- and intra-reader agreement was assessed using the intraclass correlation coefficient (ICC). Results: Qualitatively, Si-PCCT images were rated higher than EIDCT images at 150-mm FOV, based on stent appearance (p = 0.026) and blooming (p = 0.015), with a moderate inter- (ICC = 0.50) and intra-reader (ICC = 0.60) agreement. Quantitatively, Si-PCCT yielded more accurate diameter measurements (p = 0.001), reduced blooming (p < 0.001) and improved inter-stent distinction (p < 0.001). Similar trends were observed for the images reconstructed at 50-mm FOV. Conclusions: When compared to EIDCT, the improved spatial resolution of Si-PCCT yields enhanced stent appearance, more accurate diameter measurements, reduced blooming and improved inter-stent distinction. Key points: • This study evaluated stent appearance in a novel silicon-based photon-counting computed tomography (Si-PCCT) prototype. • Compared to standard CT, Si-PCCT resulted in more accurate stent diameter measurements. • Si-PCCT also reduced blooming artefacts and improved inter-stent visibility.
- Open Access
- 20 December 2022
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (1)
A patient‐ and acquisition‐tailored injection approach for improving consistency of CT enhancement towards a target CT value in coronary CT angiography
Background: Unoptimized coronary CT angiography (CTA) exams typically result in a highly variable arterial enhancement (HUa) across patients. This study aimed at harmonizing arterial enhancement by implementing a patient‐, contrast‐ and kV‐tailored injection protocol.Methods: First, the optimal body size metric to predict HUa was identified by retrospectively analysing images of 76 patients, acquired with 70 ml contrast media (G1). Second, using phantom experiments, correction factors for the effect of kV and contrast concentration on HUa were determined. Third, a model was developed, prescribing the optimal contrast dose to be injected to obtain a diagnostically appropriate arterial target enhancement HUtarget. The model was then validated on 278 prospectively collected patients, in two groups with two different HUtarget: 525 HU (207 patients, G2A) and 425 HU (71 patients, G2B). The HUa histograms were compared among groups and to the target enhancement through their mean and standard deviation (SD) at 100 kVp reference level. Also, signal‐to‐noise ratio was obtained and compared among the groups.Results: Fat free mass (FFM) showed the highest correlation with HUa (r = 0.69). KVp correction factors ranged from 0.65 at 70 kVp to 1.22 at 140 kVp. The obtained model reduced the group heterogeneity (SD) from 101HU for reference G1 to 75HU (p < 0.001) for G2A and 68HU (p < 0.001) for G2B. The mean HUa of 506HU in G2A was slightly below HUtarget = 525HU (p = 0.01) whereas in G2B, the mean HUa of 414HU was not significantly different from HUtarget = 425HU (p = 0.54). The total iodine dose was lowered from 19.5 g‐I to 17.6 g‐I and 14.2 g‐I from G1 to G2A and G2B, on average.Conclusion: A contrast injection model, based on patient's fat free mass and accounting for the contrast agent concentration and the planned CT‐scan tube voltage, harmonized arterial enhancement among patients towards a predefined target enhancement in coronary CTA scanning, without affecting the bolus timing.
- 20 December 2022
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (1)
Open AccessA patient‐ and acquisition‐tailored injection approach for improving consistency of CT enhancement towards a target CT value in coronary CT angiography
Background: Unoptimized coronary CT angiography (CTA) exams typically result in a highly variable arterial enhancement (HUa) across patients. This study aimed at harmonizing arterial enhancement by implementing a patient‐, contrast‐ and kV‐tailored injection protocol.Methods: First, the optimal body size metric to predict HUa was identified by retrospectively analysing images of 76 patients, acquired with 70 ml contrast media (G1). Second, using phantom experiments, correction factors for the effect of kV and contrast concentration on HUa were determined. Third, a model was developed, prescribing the optimal contrast dose to be injected to obtain a diagnostically appropriate arterial target enhancement HUtarget. The model was then validated on 278 prospectively collected patients, in two groups with two different HUtarget: 525 HU (207 patients, G2A) and 425 HU (71 patients, G2B). The HUa histograms were compared among groups and to the target enhancement through their mean and standard deviation (SD) at 100 kVp reference level. Also, signal‐to‐noise ratio was obtained and compared among the groups.Results: Fat free mass (FFM) showed the highest correlation with HUa (r = 0.69). KVp correction factors ranged from 0.65 at 70 kVp to 1.22 at 140 kVp. The obtained model reduced the group heterogeneity (SD) from 101HU for reference G1 to 75HU (p < 0.001) for G2A and 68HU (p < 0.001) for G2B. The mean HUa of 506HU in G2A was slightly below HUtarget = 525HU (p = 0.01) whereas in G2B, the mean HUa of 414HU was not significantly different from HUtarget = 425HU (p = 0.54). The total iodine dose was lowered from 19.5 g‐I to 17.6 g‐I and 14.2 g‐I from G1 to G2A and G2B, on average.Conclusion: A contrast injection model, based on patient's fat free mass and accounting for the contrast agent concentration and the planned CT‐scan tube voltage, harmonized arterial enhancement among patients towards a predefined target enhancement in coronary CTA scanning, without affecting the bolus timing.
- Open Access
- 7 November 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (11) , 2062
Automated Motion Analysis of Bony Joint Structures from Dynamic Computer Tomography Images: A Multi-Atlas Approach
Dynamic computer tomography (CT) is an emerging modality to analyze in-vivo joint kinematics at the bone level, but it requires manual bone segmentation and, in some instances, landmark identification. The objective of this study is to present an automated workflow for the assessment of three-dimensional in vivo joint kinematics from dynamic musculoskeletal CT images. The proposed method relies on a multi-atlas, multi-label segmentation and landmark propagation framework to extract bony structures and detect anatomical landmarks on the CT dataset. The segmented structures serve as regions of interest for the subsequent motion estimation across the dynamic sequence. The landmarks are propagated across the dynamic sequence for the construction of bone embedded reference frames from which kinematic parameters are estimated. We applied our workflow on dynamic CT images obtained from 15 healthy subjects on two different joints: thumb base (n = 5) and knee (n = 10). The proposed method resulted in segmentation accuracies of 0.90 ± 0.01 for the thumb dataset and 0.94 ± 0.02 for the knee as measured by the Dice score coefficient. In terms of motion estimation, mean differences in cardan angles between the automated algorithm and manual segmentation, and landmark identification performed by an expert were below 1°. Intraclass correlation (ICC) between cardan angles from the algorithm and results from expert manual landmarks ranged from 0.72 to 0.99 for all joints across all axes. The proposed automated method resulted in reproducible and reliable measurements, enabling the assessment of joint kinematics using 4DCT in clinical routine.
- 7 November 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (11) , 2062
Open AccessAutomated Motion Analysis of Bony Joint Structures from Dynamic Computer Tomography Images: A Multi-Atlas Approach
Dynamic computer tomography (CT) is an emerging modality to analyze in-vivo joint kinematics at the bone level, but it requires manual bone segmentation and, in some instances, landmark identification. The objective of this study is to present an automated workflow for the assessment of three-dimensional in vivo joint kinematics from dynamic musculoskeletal CT images. The proposed method relies on a multi-atlas, multi-label segmentation and landmark propagation framework to extract bony structures and detect anatomical landmarks on the CT dataset. The segmented structures serve as regions of interest for the subsequent motion estimation across the dynamic sequence. The landmarks are propagated across the dynamic sequence for the construction of bone embedded reference frames from which kinematic parameters are estimated. We applied our workflow on dynamic CT images obtained from 15 healthy subjects on two different joints: thumb base (n = 5) and knee (n = 10). The proposed method resulted in segmentation accuracies of 0.90 ± 0.01 for the thumb dataset and 0.94 ± 0.02 for the knee as measured by the Dice score coefficient. In terms of motion estimation, mean differences in cardan angles between the automated algorithm and manual segmentation, and landmark identification performed by an expert were below 1°. Intraclass correlation (ICC) between cardan angles from the algorithm and results from expert manual landmarks ranged from 0.72 to 0.99 for all joints across all axes. The proposed automated method resulted in reproducible and reliable measurements, enabling the assessment of joint kinematics using 4DCT in clinical routine.
- 1 August 2019
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 213 (2) , 404-409
Iodine Dose of Administered Contrast Media Affects the Level of Radiation-Induced DNA Damage During Cardiac CT Scans
OBJECTIVE. The purpose of this study is to investigate the contributing effect of contrast media (CM) iodine dose on radiation-induced DNA damage in blood lymphocytes during a cardiac CT scan. MATERIALS AND METHODS. The minipigs were exposed 12 times in total to a fixed cardiac CT scan protocol. An unenhanced and two CM injection protocols were considered, the latter with 50% saline diluted (160 mg I/mL) and standard iodixanol. Blood samples were collected before and after CT, and radiation-induced DNA double-strand breaks were assessed using γ-H2AX (H2A histone family member X) immunofluorescent staining of the blood lymphocytes. Significant differences in foci numbers were investigated with an independent sample t test. In addition, a numeric dosimetry model was applied that simulates the cardiac CT scan, with the heart represented by a blood volume containing a mixture of six iodine concentrations (0, 10, 20, 30, 40, and 50 mg I/mL). RESULTS. Compared with the unenhanced (0 mg I/mL) protocol, the numbe...
- 1 August 2019
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 213 (2) , 404-409
Iodine Dose of Administered Contrast Media Affects the Level of Radiation-Induced DNA Damage During Cardiac CT Scans
OBJECTIVE. The purpose of this study is to investigate the contributing effect of contrast media (CM) iodine dose on radiation-induced DNA damage in blood lymphocytes during a cardiac CT scan. MATERIALS AND METHODS. The minipigs were exposed 12 times in total to a fixed cardiac CT scan protocol. An unenhanced and two CM injection protocols were considered, the latter with 50% saline diluted (160 mg I/mL) and standard iodixanol. Blood samples were collected before and after CT, and radiation-induced DNA double-strand breaks were assessed using γ-H2AX (H2A histone family member X) immunofluorescent staining of the blood lymphocytes. Significant differences in foci numbers were investigated with an independent sample t test. In addition, a numeric dosimetry model was applied that simulates the cardiac CT scan, with the heart represented by a blood volume containing a mixture of six iodine concentrations (0, 10, 20, 30, 40, and 50 mg I/mL). RESULTS. Compared with the unenhanced (0 mg I/mL) protocol, the numbe...
- Open Access
- 4 April 2019
- Published by Frontiers Media SA in Frontiers in Earth Science
- Vol. 7
An Inside Perspective on Magma Intrusion: Quantifying 3D Displacement and Strain in Laboratory Experiments by Dynamic X-Ray Computed Tomography
Magma intrusions grow to their final geometries by deforming the Earth's crust internally and by displacing the Earth's surface. Interpreting the related displacements in terms of intrusion geometry is key to forecasting a volcanic eruption. While scaled laboratory models enable us to study the relationships between surface displacement and intrusion geometry, past approaches entailed limitations regarding imaging of the laboratory model interior or simplicity of the simulated crustal rheology. Here we apply cutting-edge medical wide beam X-ray Computed Tomography (CT) to quantify in 4D the deformation induced in laboratory models by an intrusion of a magma analog (golden syrup) into a rheologically-complex granular host rock analog (sand and plaster). We extract the surface deformation and we quantify the strain field of the entire experimental volume in 3D over time by using Digital Volume Correlation (DVC). By varying the strength and height of the host material, and intrusion velocity, we observe how intrusions of contrasting geometries grow, and induce contrasting strain field characteristics and surface deformation in 4D. The novel application of CT and DVC reveals that distributed strain accommodation and mixed-mode (opening and shear) fracturing dominates in low-cohesion material overburden, and leads to the growth of thick cryptodomes or cup-shaped intrusions. More localized strain accommodation and opening-mode fracturing dominates in high-cohesion material overburden, and leads to the growth of cone sheets or thin dikes. The results demonstrate how the combination of CT and DVC can greatly enhance the utility of optically non-transparent crustal rock analogs in obtaining insights into shallow crustal deformation processes. This unprecedented perspective on the spatio-temporal interaction of intrusion growth coupled with host material deformation provides a conceptual framework that can be tested by field observations at eroded volcanic systems and by the ever increasing spatial and temporal resolution of geodetic data at active volcanoes.
- 4 April 2019
- Published by Frontiers Media SA in Frontiers in Earth Science
- Vol. 7
Open AccessAn Inside Perspective on Magma Intrusion: Quantifying 3D Displacement and Strain in Laboratory Experiments by Dynamic X-Ray Computed Tomography
Magma intrusions grow to their final geometries by deforming the Earth's crust internally and by displacing the Earth's surface. Interpreting the related displacements in terms of intrusion geometry is key to forecasting a volcanic eruption. While scaled laboratory models enable us to study the relationships between surface displacement and intrusion geometry, past approaches entailed limitations regarding imaging of the laboratory model interior or simplicity of the simulated crustal rheology. Here we apply cutting-edge medical wide beam X-ray Computed Tomography (CT) to quantify in 4D the deformation induced in laboratory models by an intrusion of a magma analog (golden syrup) into a rheologically-complex granular host rock analog (sand and plaster). We extract the surface deformation and we quantify the strain field of the entire experimental volume in 3D over time by using Digital Volume Correlation (DVC). By varying the strength and height of the host material, and intrusion velocity, we observe how intrusions of contrasting geometries grow, and induce contrasting strain field characteristics and surface deformation in 4D. The novel application of CT and DVC reveals that distributed strain accommodation and mixed-mode (opening and shear) fracturing dominates in low-cohesion material overburden, and leads to the growth of thick cryptodomes or cup-shaped intrusions. More localized strain accommodation and opening-mode fracturing dominates in high-cohesion material overburden, and leads to the growth of cone sheets or thin dikes. The results demonstrate how the combination of CT and DVC can greatly enhance the utility of optically non-transparent crustal rock analogs in obtaining insights into shallow crustal deformation processes. This unprecedented perspective on the spatio-temporal interaction of intrusion growth coupled with host material deformation provides a conceptual framework that can be tested by field observations at eroded volcanic systems and by the ever increasing spatial and temporal resolution of geodetic data at active volcanoes.
- Open Access
- 4 February 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Four-dimensional CT as a valid approach to detect and quantify kinematic changes after selective ankle ligament sectioning
The objective of the current study was to explore the potential of dynamic computed tomography to detect kinematic changes, induced by sequential sectioning of the lateral collateral ligaments of the ankle, during full motion sequence of the talocrural joint. A custom-made device was used to induce cyclic controlled ankle inversion movement in one fresh frozen cadaver leg. A 256-slice CT scanner was used to investigate four different scenarios. Scenario 1 with all ligaments intact was first investigated followed by sequential section of the anterior talo-fibular ligament (Scenario 2), the calcaneo-fibular ligament (Scenario 3) and posterior talo-fibular ligament (Scenario 4). Off-line image processing based on semi-automatic segmentation and bone rigid registration was performed. Motion parameters such as translation, rotational angles and orientation and position of the axis of rotation were calculated. Differences between scenarios were calculated. Progressive increase of cranio-caudal displacement up to 3.9 mm and flexion up to 10° compared to Scenario 1 were reported. Progressive changes in orientation (up to 20.6°) and position (up to 4.1 mm) of the axis of rotation were also shown. Estimated effective dose of 0.005 mSv (1.9 mGy CTDIvol) was reported. This study demonstrated that kinematic changes due to the absence of ligament integrity can be detected with 4DCT with minimal radiation exposure. Identifying abnormal kinematic patterns could have future application in helping clinicians to choose patients’ optimal treatment. Therefore, further studies with bigger in vitro sample sizes and consequent investigations in vivo are recommended to confirm the current findings.
- 4 February 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Open AccessFour-dimensional CT as a valid approach to detect and quantify kinematic changes after selective ankle ligament sectioning
The objective of the current study was to explore the potential of dynamic computed tomography to detect kinematic changes, induced by sequential sectioning of the lateral collateral ligaments of the ankle, during full motion sequence of the talocrural joint. A custom-made device was used to induce cyclic controlled ankle inversion movement in one fresh frozen cadaver leg. A 256-slice CT scanner was used to investigate four different scenarios. Scenario 1 with all ligaments intact was first investigated followed by sequential section of the anterior talo-fibular ligament (Scenario 2), the calcaneo-fibular ligament (Scenario 3) and posterior talo-fibular ligament (Scenario 4). Off-line image processing based on semi-automatic segmentation and bone rigid registration was performed. Motion parameters such as translation, rotational angles and orientation and position of the axis of rotation were calculated. Differences between scenarios were calculated. Progressive increase of cranio-caudal displacement up to 3.9 mm and flexion up to 10° compared to Scenario 1 were reported. Progressive changes in orientation (up to 20.6°) and position (up to 4.1 mm) of the axis of rotation were also shown. Estimated effective dose of 0.005 mSv (1.9 mGy CTDIvol) was reported. This study demonstrated that kinematic changes due to the absence of ligament integrity can be detected with 4DCT with minimal radiation exposure. Identifying abnormal kinematic patterns could have future application in helping clinicians to choose patients’ optimal treatment. Therefore, further studies with bigger in vitro sample sizes and consequent investigations in vivo are recommended to confirm the current findings.
- Open Access
- 30 November 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 17493
Improved enhancement in CT angiography with reduced contrast media iodine concentrations at constant iodine dose
The study objective is to investigate the impact of a wide range of contrast media (CM) iodine concentrations on CT enhancement at constant total iodine dose (TID) and iodine delivery rate (IDR). Seven injection protocols, based on different iodine concentrations ranging from 120 to 370 mg I/mL, were assessed on 4 minipigs at a constant TID of 320 mg I/kg and IDR of 0.64 g I/s. Dynamic images were acquired on a clinical 64-slice MDCT scanner for 120 s with the abdominal aorta, vena cava inferior and liver parenchyma in the field-of-view. Maximal enhancement, time-to-peak and peak width were assessed. The enhancement curve characteristics were correlated with CM iodine concentration. In particular, CM with lower iodine concentrations yielded a significant increased maximal enhancement and peak width compared to the standard-of-care concentrations: e.g. in the aorta, 245 HU maximal enhancement and 9.2 s peak width with the 320 mg I/mL iodine concentration increased to 291 HU and 16.1 s with 160 mg I/mL. When maintaining a constant TID and IDR, by compensating injection rate and volume, injection of a CM with reduced iodine concentration results in a diagnostically beneficial higher maximal enhancement and longer enhancement peak duration.
- 30 November 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 17493
Open AccessImproved enhancement in CT angiography with reduced contrast media iodine concentrations at constant iodine dose
The study objective is to investigate the impact of a wide range of contrast media (CM) iodine concentrations on CT enhancement at constant total iodine dose (TID) and iodine delivery rate (IDR). Seven injection protocols, based on different iodine concentrations ranging from 120 to 370 mg I/mL, were assessed on 4 minipigs at a constant TID of 320 mg I/kg and IDR of 0.64 g I/s. Dynamic images were acquired on a clinical 64-slice MDCT scanner for 120 s with the abdominal aorta, vena cava inferior and liver parenchyma in the field-of-view. Maximal enhancement, time-to-peak and peak width were assessed. The enhancement curve characteristics were correlated with CM iodine concentration. In particular, CM with lower iodine concentrations yielded a significant increased maximal enhancement and peak width compared to the standard-of-care concentrations: e.g. in the aorta, 245 HU maximal enhancement and 9.2 s peak width with the 320 mg I/mL iodine concentration increased to 291 HU and 16.1 s with 160 mg I/mL. When maintaining a constant TID and IDR, by compensating injection rate and volume, injection of a CM with reduced iodine concentration results in a diagnostically beneficial higher maximal enhancement and longer enhancement peak duration.