Hiroyuki Kosaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hiroyuki Kosaka has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Hajime Monzen
Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka, Japan
6 shared publications - Mikoto Tamura
Department of Medical Physics, Graduate School of Medical Sciences, Kindai University , 377-2 Ohno-higashi, Osakasayama, Osaka 589-8511 , Japan
3 shared publications - Yuki Kono
Radiology Center, Kindai University Hospital, Osakasayama, Japan
3 shared publications - Yuya Yanagi
Department of Radiology, Shiga University of Medical Science Hospital, Setatsukinowa, Otsu, Shiga, 5202192, Japan
3 shared publications - Kazunari Ishii
Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
2 shared publications - Shota Watanabe
Faculty of Medical Science Technology, Morinomiya University of Medical Sciences, Osaka, Japan
2 shared publications
Latest Publications
- Open Access
- 8 February 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (1) , 313-320
Robustness of heart dose against cardiac cycle in breast cancer radiotherapy with deep inspiration breath-hold
This study evaluated dose differences to the heart, left anterior descending coronary artery (LADCA), and left main coronary artery (LMCA) between diastolic and systolic heart phases in radiation therapy for left-sided breast cancer using deep inspiration breath-hold (DIBH). Diastolic and systolic doses to the heart, LADCA, and LMCA were analyzed using electrocardiogram-gated cardiac computed tomography images from 15 women. Radiation therapy plans were created for a total dose of 50 Gy in 25 fractions. Parameters assessed included volume, D mean , D 2% , V 5Gy , V 10Gy , V 20Gy , and V 25Gy for the heart; D mean , D 2% , V 5Gy , V 10Gy , and V 20Gy for the LADCA; and D mean and D 2% for the LMCA. The D mean of the heart was 5.10 ± 3.04 Gy and 5.03 ± 3.05 Gy for diastole and systole, respectively (mean ± 1 standard deviation), and D 2% was 37.44 ± 16.03 Gy and 36.15 ± 16.76 Gy. Statistically significant differences were found in the D mean . LADCA doses showed no significant differences, possibly due to anatomical variations. The D mean of the LMCA was 1.88 ± 0.23 Gy and 2.02 ± 0.28 Gy for diastole and systole, and D 2% was 2.05 ± 0.28 Gy and 2.21 ± 0.30 Gy, with both parameters being statistically significantly higher during systole. Although small, cardiac-phase-dependent dose variations under DIBH were statistically significant, confirming that current non-ECG-gated DIBH remains adequate for cardiac dose management.
- 8 February 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (1) , 313-320
Open AccessRobustness of heart dose against cardiac cycle in breast cancer radiotherapy with deep inspiration breath-hold
This study evaluated dose differences to the heart, left anterior descending coronary artery (LADCA), and left main coronary artery (LMCA) between diastolic and systolic heart phases in radiation therapy for left-sided breast cancer using deep inspiration breath-hold (DIBH). Diastolic and systolic doses to the heart, LADCA, and LMCA were analyzed using electrocardiogram-gated cardiac computed tomography images from 15 women. Radiation therapy plans were created for a total dose of 50 Gy in 25 fractions. Parameters assessed included volume, D mean , D 2% , V 5Gy , V 10Gy , V 20Gy , and V 25Gy for the heart; D mean , D 2% , V 5Gy , V 10Gy , and V 20Gy for the LADCA; and D mean and D 2% for the LMCA. The D mean of the heart was 5.10 ± 3.04 Gy and 5.03 ± 3.05 Gy for diastole and systole, respectively (mean ± 1 standard deviation), and D 2% was 37.44 ± 16.03 Gy and 36.15 ± 16.76 Gy. Statistically significant differences were found in the D mean . LADCA doses showed no significant differences, possibly due to anatomical variations. The D mean of the LMCA was 1.88 ± 0.23 Gy and 2.02 ± 0.28 Gy for diastole and systole, and D 2% was 2.05 ± 0.28 Gy and 2.21 ± 0.30 Gy, with both parameters being statistically significantly higher during systole. Although small, cardiac-phase-dependent dose variations under DIBH were statistically significant, confirming that current non-ECG-gated DIBH remains adequate for cardiac dose management.
- Open Access
- 10 October 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (10) , e70301
Impact of extended source‐to‐surface distances and respiratory motion on the precision of electron beam therapy
Purpose: In electron beam therapy targeting superficial thoracic and abdominal lesions, the source‐to‐surface distance (SSD) varies due to patient respiration. This study aimed to investigate the percentage depth dose (PDD) and off‐center ratio (OCR) of 6, 9, and 12 MeV electron beams at extended SSDs; and to assess the variations in dose caused by respiratory motion. Methods: PDDs and OCRs for 6, 9, and 12 MeV electron beams were measured using a Blue Phantom 2 with 5 cm circular aperture and 10 × 10 cm 2 fields at SSDs ranging from 98 to 105 cm. The dose differences at the maximum depth ( d max ) were calculated relative to an SSD of 100 cm. We simulated patient respiratory motion of 0–4 cm during irradiation with 5 cm circular aperture and 10 × 10 cm 2 fields by placing a water‐equivalent phantom with a parallel‐plate ionization chamber on a QUASAR Platform. The gantry angle was set to 270°, and the SSD was set to 100 cm. The dose differences at d max were calculated relative to a motion amplitude of 0 cm. Results: Extending the SSD by 3 cm reduced the dose by > 5% for all energies. For a 6 MeV electron beam with a 5 cm circular aperture, extending the SSD to 105 cm resulted in a dose reduction of 13.42% and expansions of the field size by 2.0 mm and the penumbra by 4.2 mm. A respiratory motion amplitude of 3 cm resulted in dose variations of > 3% for all energies and field sizes. The largest dose difference of 5.36% was observed for a 6 MeV electron beam with a 5 cm circular aperture. Conclusions: The results demonstrate that extending the SSD by 3 cm reduced the dose by >5% for all energies, providing a useful quantitative benchmark for quality assurance in superficial electron therapy. Respiratory motion management may be warranted for electron beam therapy when respiratory‐induced SSD variations exceed 3 cm.
- 10 October 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (10) , e70301
Open AccessImpact of extended source‐to‐surface distances and respiratory motion on the precision of electron beam therapy
Purpose: In electron beam therapy targeting superficial thoracic and abdominal lesions, the source‐to‐surface distance (SSD) varies due to patient respiration. This study aimed to investigate the percentage depth dose (PDD) and off‐center ratio (OCR) of 6, 9, and 12 MeV electron beams at extended SSDs; and to assess the variations in dose caused by respiratory motion. Methods: PDDs and OCRs for 6, 9, and 12 MeV electron beams were measured using a Blue Phantom 2 with 5 cm circular aperture and 10 × 10 cm 2 fields at SSDs ranging from 98 to 105 cm. The dose differences at the maximum depth ( d max ) were calculated relative to an SSD of 100 cm. We simulated patient respiratory motion of 0–4 cm during irradiation with 5 cm circular aperture and 10 × 10 cm 2 fields by placing a water‐equivalent phantom with a parallel‐plate ionization chamber on a QUASAR Platform. The gantry angle was set to 270°, and the SSD was set to 100 cm. The dose differences at d max were calculated relative to a motion amplitude of 0 cm. Results: Extending the SSD by 3 cm reduced the dose by > 5% for all energies. For a 6 MeV electron beam with a 5 cm circular aperture, extending the SSD to 105 cm resulted in a dose reduction of 13.42% and expansions of the field size by 2.0 mm and the penumbra by 4.2 mm. A respiratory motion amplitude of 3 cm resulted in dose variations of > 3% for all energies and field sizes. The largest dose difference of 5.36% was observed for a 6 MeV electron beam with a 5 cm circular aperture. Conclusions: The results demonstrate that extending the SSD by 3 cm reduced the dose by >5% for all energies, providing a useful quantitative benchmark for quality assurance in superficial electron therapy. Respiratory motion management may be warranted for electron beam therapy when respiratory‐induced SSD variations exceed 3 cm.
- 2 June 2023
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 46 (3) , 1153-1162
Noise reduction performance of a deep learning-based reconstruction in brain computed tomography images acquired with organ-based tube current modulation
We aimed to evaluate the image quality of brain computed tomography (CT) images reconstructed using deep learning-based reconstruction (DLR) in organ-based tube current modulation (OB-TCM) acquisition. An anthropomorphic head phantom and a cylindrical low-contrast phantom were scanned at the standard dose level for adult brain CT in axial volume acquisition without OB-TCM. Moreover, image acquisition with OB-TCM was performed. The radiation dose on the eye lens was measured using a scintillation fibre-optic dosimeter placed on the anthropomorphic phantom’s eye surface. The task transfer function (TTF), contrast-to-noise ratio (CNR), and low-contrast object specific CNR obtained from low-contrast phantom images reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR), and two types of DLR (DLRCTA and DLRLCD) were compared. In result, OB-TCM achieved a 32.5% dose reduction in the eye lens. Although HIR, DLRCTA, and DLRLCD showed lower TTF than FBP, the difference in TTF at the highest contributing spatial frequency corresponding to the contrast rod diameter was < 10%. Despite the OB-TCM acquisition, DLRCTA and DLRLCD achieved significantly lower noise and a higher CNR than FBP without OB-TCM (p < 0.05). However, low-contrast object specific CNR was equivalent among all reconstruction methods for the objective diameter of 5 mm and slightly improved in DLRLCD for the objective diameter of 7 mm. DLR with OB-TCM acquisition enabled dose reduction for the eye lens and high CNR image appearance, whereas the low contrast detectability evaluated by low-contrast object specific CNR did not always improve.
- 2 June 2023
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 46 (3) , 1153-1162
Noise reduction performance of a deep learning-based reconstruction in brain computed tomography images acquired with organ-based tube current modulation
We aimed to evaluate the image quality of brain computed tomography (CT) images reconstructed using deep learning-based reconstruction (DLR) in organ-based tube current modulation (OB-TCM) acquisition. An anthropomorphic head phantom and a cylindrical low-contrast phantom were scanned at the standard dose level for adult brain CT in axial volume acquisition without OB-TCM. Moreover, image acquisition with OB-TCM was performed. The radiation dose on the eye lens was measured using a scintillation fibre-optic dosimeter placed on the anthropomorphic phantom’s eye surface. The task transfer function (TTF), contrast-to-noise ratio (CNR), and low-contrast object specific CNR obtained from low-contrast phantom images reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR), and two types of DLR (DLRCTA and DLRLCD) were compared. In result, OB-TCM achieved a 32.5% dose reduction in the eye lens. Although HIR, DLRCTA, and DLRLCD showed lower TTF than FBP, the difference in TTF at the highest contributing spatial frequency corresponding to the contrast rod diameter was < 10%. Despite the OB-TCM acquisition, DLRCTA and DLRLCD achieved significantly lower noise and a higher CNR than FBP without OB-TCM (p < 0.05). However, low-contrast object specific CNR was equivalent among all reconstruction methods for the objective diameter of 5 mm and slightly improved in DLRLCD for the objective diameter of 7 mm. DLR with OB-TCM acquisition enabled dose reduction for the eye lens and high CNR image appearance, whereas the low contrast detectability evaluated by low-contrast object specific CNR did not always improve.
- 5 May 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (10) , 105007
The development and characterization of an all-purpose bolus for radiotherapy
Objective. The purpose of this study was to develop a new bolus (HM bolus), with tissue equivalence, transparency, reusability, and free shaping at approximately 40 °C for excellent adhesion, and to evaluate the feasibility of clinically using this bolus as an ideal bolus. Approach. We summarized the advantages and disadvantages of existing boluses. To evaluate dose characteristics, a vinyl gel sheet bolus (Gel bolus) and HM bolus placed on a water-equivalent phantom were used to obtain the percentage depth dose (PDD) of electron (6 MeV, 9 MeV) and photon (4 MV, 6 MV) beams. The average dose difference of the HM bolus and Gel bolus was calculated. The Gel bolus, a soft rubber bolus (SR bolus), and HM bolus were placed in adherence to a pelvic phantom. CT images taken after shaping and 1, 2, and 3 weeks after shaping were used to evaluate the adhesion and reproducibility using air gap and dice similarity coefficient (DSC). Main results. The average dose difference for electron beams was 0.16% ± 0.79% and photon beams was 0.06% ± 0.34%, both within 1% of the PDD results. The HM bolus showed the same build-up effect and dose characteristics as the Gel bolus. The mean air gap values for the Gel bolus, SR bolus, and HM bolus were 96.02 ± 43.77 cm 3 , 34.93 ± 21.44 cm 3 , and 4.40 ± 1.50 cm 3 , respectively. The mean DSC values compared to initial images for the Gel bolus, SR bolus, and HM bolus were 0.363 ± 0.035, 0.556 ± 0.042, and 0.837 ± 0.018, respectively. Excellent adhesion was observed in the CT simulation and during the treatment period. Significance. The HM bolus has unique features, such as tissue equivalence, transparency, reusability, and free shaping for excellent adhesion, and is thus an ideal bolus for use in clinical cases.
- 5 May 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (10) , 105007
The development and characterization of an all-purpose bolus for radiotherapy
Objective. The purpose of this study was to develop a new bolus (HM bolus), with tissue equivalence, transparency, reusability, and free shaping at approximately 40 °C for excellent adhesion, and to evaluate the feasibility of clinically using this bolus as an ideal bolus. Approach. We summarized the advantages and disadvantages of existing boluses. To evaluate dose characteristics, a vinyl gel sheet bolus (Gel bolus) and HM bolus placed on a water-equivalent phantom were used to obtain the percentage depth dose (PDD) of electron (6 MeV, 9 MeV) and photon (4 MV, 6 MV) beams. The average dose difference of the HM bolus and Gel bolus was calculated. The Gel bolus, a soft rubber bolus (SR bolus), and HM bolus were placed in adherence to a pelvic phantom. CT images taken after shaping and 1, 2, and 3 weeks after shaping were used to evaluate the adhesion and reproducibility using air gap and dice similarity coefficient (DSC). Main results. The average dose difference for electron beams was 0.16% ± 0.79% and photon beams was 0.06% ± 0.34%, both within 1% of the PDD results. The HM bolus showed the same build-up effect and dose characteristics as the Gel bolus. The mean air gap values for the Gel bolus, SR bolus, and HM bolus were 96.02 ± 43.77 cm 3 , 34.93 ± 21.44 cm 3 , and 4.40 ± 1.50 cm 3 , respectively. The mean DSC values compared to initial images for the Gel bolus, SR bolus, and HM bolus were 0.363 ± 0.035, 0.556 ± 0.042, and 0.837 ± 0.018, respectively. Excellent adhesion was observed in the CT simulation and during the treatment period. Significance. The HM bolus has unique features, such as tissue equivalence, transparency, reusability, and free shaping for excellent adhesion, and is thus an ideal bolus for use in clinical cases.
- 8 January 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (4) , 366-372
REDUCTION OF THE COMPUTED TOMOGRAPHY DOSE TO THE GONADS OF ADOLESCENT AND YOUNG ADULT MALES THROUGH USE OF A TUNGSTEN-CONTAINING RUBBER SHEET
This study aims to measure the shielding effect of a novel tungsten rubber sheet (TRS) on the exposure of male gonads to ionizing radiation during upper abdominal and abdominal plus pelvic computed tomography (CT) examinations. The air kerma at the gonad with and without shielding was measured using an anthropomorphic body phantom. Gonads were shielded using: (1) 360° wrap with TRS (0.5-mm thick) and (2) 180° wrap with TRS. The air kerma at a position of male gonads in a pelvic scan was 21.8 mGy, even when the gonads were in the off-axis range. The TRS reduced the dose to the male gonads in abdominal plus pelvic CT examinations by 61% and 38% for the 360° and 180° TRS wrap, respectively.
- 8 January 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (4) , 366-372
REDUCTION OF THE COMPUTED TOMOGRAPHY DOSE TO THE GONADS OF ADOLESCENT AND YOUNG ADULT MALES THROUGH USE OF A TUNGSTEN-CONTAINING RUBBER SHEET
This study aims to measure the shielding effect of a novel tungsten rubber sheet (TRS) on the exposure of male gonads to ionizing radiation during upper abdominal and abdominal plus pelvic computed tomography (CT) examinations. The air kerma at the gonad with and without shielding was measured using an anthropomorphic body phantom. Gonads were shielded using: (1) 360° wrap with TRS (0.5-mm thick) and (2) 180° wrap with TRS. The air kerma at a position of male gonads in a pelvic scan was 21.8 mGy, even when the gonads were in the off-axis range. The TRS reduced the dose to the male gonads in abdominal plus pelvic CT examinations by 61% and 38% for the 360° and 180° TRS wrap, respectively.
- 8 July 2022
- Published by Elsevier in Radiography
- Vol. 28 (4) , 912-918
Development of a radiopaque tiltmeter to improve reproducibility for Fowler's position on chest radiography
- 8 July 2022
- Published by Elsevier in Radiography
- Vol. 28 (4) , 912-918
Development of a radiopaque tiltmeter to improve reproducibility for Fowler's position on chest radiography
- 1 August 2020
- Published by Elsevier in Physica Medica
- Vol. 76, 100-108
Image quality comparison of a nonlinear image-based noise reduction technique with a hybrid-type iterative reconstruction for pediatric computed tomography
- 1 August 2020
- Published by Elsevier in Physica Medica
- Vol. 76, 100-108
Image quality comparison of a nonlinear image-based noise reduction technique with a hybrid-type iterative reconstruction for pediatric computed tomography
- 1 March 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 124, 108814
Radiation dose reduction to the eye lens in head CT using tungsten functional paper and organ-based tube current modulation
- 1 March 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 124, 108814
Radiation dose reduction to the eye lens in head CT using tungsten functional paper and organ-based tube current modulation