Yuki Kono
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yuki Kono has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Hiroyuki Kosaka
Department of Medical Physics, Graduate School of Medical Sciences, Kindai University Osaka Medical Campus, Sakai, Japan
3 shared publications - Kazunari Ishii
Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan
2 shared publications - Shota Watanabe
Faculty of Medical Science Technology, Morinomiya University of Medical Sciences, Osaka, Japan
2 shared publications - Hajime Monzen
Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka, Japan
1 shared publication - Hiroki Kawashima
Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan
1 shared publication - Katsuhiro Ichikawa
Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan
1 shared publication
Latest Publications
- 2 June 2023
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 46 (3) , 1153-1162
Noise reduction performance of a deep learning-based reconstruction in brain computed tomography images acquired with organ-based tube current modulation
We aimed to evaluate the image quality of brain computed tomography (CT) images reconstructed using deep learning-based reconstruction (DLR) in organ-based tube current modulation (OB-TCM) acquisition. An anthropomorphic head phantom and a cylindrical low-contrast phantom were scanned at the standard dose level for adult brain CT in axial volume acquisition without OB-TCM. Moreover, image acquisition with OB-TCM was performed. The radiation dose on the eye lens was measured using a scintillation fibre-optic dosimeter placed on the anthropomorphic phantom’s eye surface. The task transfer function (TTF), contrast-to-noise ratio (CNR), and low-contrast object specific CNR obtained from low-contrast phantom images reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR), and two types of DLR (DLRCTA and DLRLCD) were compared. In result, OB-TCM achieved a 32.5% dose reduction in the eye lens. Although HIR, DLRCTA, and DLRLCD showed lower TTF than FBP, the difference in TTF at the highest contributing spatial frequency corresponding to the contrast rod diameter was < 10%. Despite the OB-TCM acquisition, DLRCTA and DLRLCD achieved significantly lower noise and a higher CNR than FBP without OB-TCM (p < 0.05). However, low-contrast object specific CNR was equivalent among all reconstruction methods for the objective diameter of 5 mm and slightly improved in DLRLCD for the objective diameter of 7 mm. DLR with OB-TCM acquisition enabled dose reduction for the eye lens and high CNR image appearance, whereas the low contrast detectability evaluated by low-contrast object specific CNR did not always improve.
- 2 June 2023
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 46 (3) , 1153-1162
Noise reduction performance of a deep learning-based reconstruction in brain computed tomography images acquired with organ-based tube current modulation
We aimed to evaluate the image quality of brain computed tomography (CT) images reconstructed using deep learning-based reconstruction (DLR) in organ-based tube current modulation (OB-TCM) acquisition. An anthropomorphic head phantom and a cylindrical low-contrast phantom were scanned at the standard dose level for adult brain CT in axial volume acquisition without OB-TCM. Moreover, image acquisition with OB-TCM was performed. The radiation dose on the eye lens was measured using a scintillation fibre-optic dosimeter placed on the anthropomorphic phantom’s eye surface. The task transfer function (TTF), contrast-to-noise ratio (CNR), and low-contrast object specific CNR obtained from low-contrast phantom images reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR), and two types of DLR (DLRCTA and DLRLCD) were compared. In result, OB-TCM achieved a 32.5% dose reduction in the eye lens. Although HIR, DLRCTA, and DLRLCD showed lower TTF than FBP, the difference in TTF at the highest contributing spatial frequency corresponding to the contrast rod diameter was < 10%. Despite the OB-TCM acquisition, DLRCTA and DLRLCD achieved significantly lower noise and a higher CNR than FBP without OB-TCM (p < 0.05). However, low-contrast object specific CNR was equivalent among all reconstruction methods for the objective diameter of 5 mm and slightly improved in DLRLCD for the objective diameter of 7 mm. DLR with OB-TCM acquisition enabled dose reduction for the eye lens and high CNR image appearance, whereas the low contrast detectability evaluated by low-contrast object specific CNR did not always improve.
- 1 August 2020
- Published by Elsevier in Physica Medica
- Vol. 76, 100-108
Image quality comparison of a nonlinear image-based noise reduction technique with a hybrid-type iterative reconstruction for pediatric computed tomography
- 1 August 2020
- Published by Elsevier in Physica Medica
- Vol. 76, 100-108
Image quality comparison of a nonlinear image-based noise reduction technique with a hybrid-type iterative reconstruction for pediatric computed tomography
- 1 March 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 124, 108814
Radiation dose reduction to the eye lens in head CT using tungsten functional paper and organ-based tube current modulation
- 1 March 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 124, 108814
Radiation dose reduction to the eye lens in head CT using tungsten functional paper and organ-based tube current modulation