AUAkiko Ueda

Akiko Ueda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Akiko Ueda has a total of 67 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Management of patients with electrical storm at Kyorin University

    by Chutimon Junkrasien, Akiko Ueda, Yumi Katsume, Kyoko Soejima

  • Open Access

    Hidden Remodeling in Hypothyroidism: Insights From AF Ablation

    by Akiko Ueda

    Ueda A. Korean Circ J. 2026 Jan;56:e58. https://doi.org/10.4070/kcj.2025.0510

  • Early Corticosteroid Therapy and Its Effect on Ventricular Tachyarrhythmia Recurrence in Cardiac Sarcoidosis: A 10‐Year Longitudinal Multicenter Study

    by Akiko Ueda, Koji Nakagawa, Koji Miyamoto, Reina Tonegawa‐Kuji, Miyako Igarashi, Kenji Okubo, Akihiko Nogami, Kengo Kusano, Kyoko Soejima

    Introduction: The role of corticosteroids in the management of ventricular tachyarrhythmia (VA) in cardiac sarcoidosis (CS) remains controversial. This study assessed the effect of early steroid initiation on VA recurrence rates in patients with CS and evaluated VA frequency before and after steroid therapy.Methods: From a registry of 137 patients with CS with arrhythmias, those with VA and more than 60 days of follow‐up were included. Patients were categorized into three groups: previous‐on‐steroid, those using corticosteroids at the time of the first VA (n = 15); early‐steroid, those with steroid initiation within 60 days (n = 21); and no‐or‐delayed‐steroid, those without steroid use at 60 days from the first VA (n = 35). The VA recurrence and timing were analyzed.Results: The median age at the first VA was 60 years. Over a median follow‐up period of 81 (range: 4–345) months, 43 patients experienced VA recurrence. The median time to recurrence was 101, 33, and 17 months in the early‐steroid, no‐or‐delayed steroid, and previous‐on‐steroid groups, respectively. Corticosteroid use at 60 days was an independent predictor of VA recurrence at 120 months (hazard ratio: 2.257; p = 0.045 in the no‐or‐delayed steroid group and hazard ratio: 3.155; p = 0.021 in the previous‐on‐steroid group vs. the early‐steroid group). Low left ventricular ejection fraction (LVEF) was associated with frequent VA episodes. Corticosteroid initiation did not increase early VA episodes.Conclusion: Early corticosteroid initiation after VA onset reduced the long‐term recurrence without increasing early episodes. Cases of repetitive VA were common in those with low LVEF.


  • Open Access

    Wristwatch pulse wave monitoring: assessing daily activity post-catheter ablation for atrial fibrillation

    by Noriko Matsushita Nonoguchi, Kyoko Soejima, Yumi Katsume, Kyoko Hoshida, Ikuko Togashi, Ayumi Goda, Akiko Ueda, Seiichiro Matsuo, Toshiaki Sato, Yuichi Takano, et al.

    Aims: Atrial fibrillation (AF) leads to impaired exercise capacity, and catheter ablation (CA) for AF improves exercise capacity. However, the precise changes in daily activities after CA for AF remain unclear. The authors aimed to evaluate the changes in daily activities following CA for AF using a wristwatch-type pulse wave monitor (PWM), which tracks steps and exercise time, estimates burnt daily calories, and records sleep duration, in addition to establishing the rhythm diagnosis of AF or non-AF. Methods and results: One hundred and twenty-three patients with AF (97 paroxysmal, 26 persistent) wore a wristwatch-type PWM for 1 week duration at three time points: before, 1 month after, and 3 months after ablation. Daily activity data were compared. Steps did not change in both groups, and the number of burnt daily calories and total exercise time increased after CA in patients with paroxysmal AF (burnt daily calories: before, 1591 kcal/day; 1 month, 1688 kcal/day; and 3 months, 1624 kcal/day; P < 0.001 and exercise time: before, 45.8 min; 1 month, 51.2 min; and 3 months, 56.3 min; P = 0.023). Sleep hours significantly increased (paroxysmal AF: before, 6.8 h; 1 month, 7.1 h; and 3 months, 7.1 h; P = 0.039 and persistent AF: before, 6.0 h; 1 month, 7.0 h; and 3 months, 7.0 h; P = 0.007). Conclusion: Using a wristwatch-type PWM, we demonstrated changes in daily activities after CA in patients with AF. Trial registration number: jRCT1030210022.


  • Open Access

    Systematic observation‐based diagnosis of atrioventricular nodal reentrant tachycardia with a bystander concealed nodoventricular pathway

    by Koichi Nagashima, Mitsunori Maruyama, Yoshiaki Kaneko, Satoshi Sakai, Takayuki Sekihara, Tetsuma Kawaji, Hidehiro Iwakawa, Yasuyuki Egami, Chisato Ota, Satoshi Nagase, et al.

    Background: This study aimed to establish a systematic method for diagnosing atrioventricular nodal reentrant tachycardia (AVNRT) with a bystander concealed nodoventricular pathway (cNVP).Methods: We analyzed 13 cases of AVNRT with a bystander cNVP, 11 connected to the slow pathway (cNVP‐SP) and two to the fast pathway (cNVP‐FP), along with two cases of cNVP‐related orthodromic reciprocating tachycardia (ORT).Results: The diagnostic process was summarized in three steps. Step 1 was identification of the presence of an accessory pathway by resetting the tachycardia with delay (n = 9) and termination without atrial capture (n = 4) immediately after delivery of a His‐refractory premature ventricular contraction (PVC). Step 2 was exclusion of ORT by atrio‐His block during the tachycardia (n = 4), disappearance of the reset phenomenon after the early PVC (n = 7), or dissociation of His from the tachycardia during ventricular overdrive pacing (n = 1). Moreover, tachycardia reset/termination without the atrial capture (n = 2/2) 1 cycle after the His‐refractory PVC was specifically diagnostic. Exceptionally, the disappearance of the reset phenomenon was also observed in the two cNVP‐ORTs. Step 3 was verification of the AVN as the cNVP insertion site, evidenced by an atrial reset/block preceding the His reset/block in fast–slow AVNRT with a cNVP‐SP and slow–fast AVNRT with a cNVP‐FP or His reset preceding the atrial reset in slow–fast AVNRT with a cNVP‐SP.Conclusion: AVNRT with a bystander cNVP can be diagnosed in the three steps with few exceptions. Notably, tachycardia reset/termination without atrial capture one cycle after delivery of a His‐refractory PVC is specifically diagnostic.


  • Open Access

    Diverse QRS morphology reflecting variations in lead placement for left bundle branch area pacing

    by Toshiaki Sato, Ikuko Togashi, Hirotsugu Ikewaki, Takato Mohri, Yumi Katsume, Mika Tashiro, Noriko Nonoguchi, Kyoko Hoshida, Akiko Ueda, Seiichiro Matsuo, et al.

    Aims: Left bundle branch area pacing (LBBAP) is a potential alternative to His bundle pacing. This study aimed to investigate the impact of different septal locations of pacing leads on the diversity of QRS morphology during non-selective LBBAP. Methods and results: Non-selective LBBAP and left ventricular septal pacing (LVSP) were achieved in 50 and 21 patients with atrioventricular block, respectively. The electrophysiological properties of LBBAP and their relationship with the lead location were investigated. QRS morphology and axis showed broad variations during LBBAP. Echocardiography demonstrated a widespread distribution of LBBAP leads in the septum. During non-selective LBBAP, the qR-wave in lead V1 indicated that the primary location for pacing lead was the inferior septum (93%). The non-selective LBBAP lead was deployed deeper than the LVSP lead in the inferior septum. The Qr-wave in lead V1 with the inferior axis in aVF suggested pacing lead placement in the anterior septum. The penetration depth of the non-selective LBBAP lead in the anterior septum was significantly shallower than that in the inferior septum (72 ± 11 and 87 ± 8%, respectively). In lead V6, the deep S-wave indicated the time lag between the R-wave peak and the latest ventricular activation in the coronary sinus trunk, with pacemaker leads deployed closer to the left ventricular apex. Conclusion: Different QRS morphologies and axes were linked to the location of the non-selective LBBAP lead in the septum. Various lead deployments are feasible for LBBAP, allowing diversity in the conduction system capture in patients with atrioventricular block.


  • Temporal and spatial pacemap parameters for identification of cardiac surfaces with critical sites for ventricular tachycardia

    by Akiko Ueda, Yumi Katsume, Yosuke Miwa, Takato Mohri, Mika Tashiro, Noriko Nonoguchi, Kyoko Hoshida, Ikuko Togashi, Toshiaki Sato, Kyoko Soejima, et al.

    Introduction: Multisurface pacemapping may help identify the surface of interest in scar‐related ventricular tachycardia (VT). This study aimed to investigate the performance of pacemap parameters for detecting critical sites through multisurface mapping.Methods and Results: In 26 patients who underwent scar‐related VT ablation, pacemap parameters including a matching score, the difference between the longest and shortest stimulus‐QRS intervals (Δs‐QRS), and the distance between the good pacemap sites were measured. The parameters were compared between surfaces with and without critical sites and ablation outcomes. A total of 941 pacemap at 56 surfaces targeting 35 VTs were analyzed. A greater Δs‐QRS (40 vs. 8 ms, p < .001) and longer distance between two good pacemap sites (24 vs. 13 mm, p < .001) were observed on the surfaces with critical sites. A similar trend was seen in multisurface pacemapping for the same VTs (52 vs. 18 ms in Δs‐QRS, p = .021; 37 vs. 12 mm in distance, p = .019), although the best pacemap scores were comparable (94 vs. 87, p = .295). The Δs‐QRS > 20 ms and the distance >19 mm showed high positive likelihood ratios (19.8 and 6.1, respectively) for discriminating the surface harboring the critical site. Ablation of VTs fulfilling these parameters was successful on the surfaces, but without the required multisurface ablation.Conclusion: Temporal (Δs‐QRS) and spatial (distance) parameters for good pacemap match sites were excellent markers for detecting the surface harboring critical sites in scar‐related VT. A multisurface pacemapping can successfully identify the surface of interest.


  • Conduction slowing area during sinus rhythm harbors ventricular tachycardia isthmus

    by Akiko Ueda, Kyoko Soejima, Shiro Nakahara, Reiko Fukuda, Seiji Fukamizu, Iwanari Kawamura, Yosuke Miwa, Takato Mohri, Yumi Katsume, other members of the ILAM‐PM Study Group

    Introduction: The voltage map during sinus rhythm (SR) is a cornerstone of substrate mapping (SM) in scar‐related ventricular tachycardia (VT) and frequently used with pace mapping (PM). Where to conduct PM is unclear in cases of an extensive or unidentified substrate. Conduction properties are another aspect incorporated by SM, and conduction slowing has gained interest as being related to successful ablation, although its mechanism has not been elucidated. We aimed to investigate the relationship between SR conduction properties and VT isthmuses.Methods: Nineteen patients (mean age, 62 years) who underwent VT ablation with voltage mapping and PM were reviewed. Isochronal late activation maps (ILAMs) with eight zones were reconstructed and sequentially named from one to eight according to the SR propagation. Good PM sites were superimposed on ILAMs, and the isthmus was defined using different pacing latencies. ILAM properties harboring isthmuses were investigated.Results: Twenty‐eight ILAMs (13 epicardium, 1 right ventricular [RV], and 14 left ventricular [LV] endocardium) were reviewed. Eighteen isthmuses of 24 target VTs were identified, in which the proximal ends were in a later zone than the distal ends (zone 6 vs 4; P < .001), suggesting a reverse isthmus vector to the SR. The conduction velocity of the zone involving the distal isthmus was significantly lower than that of the SR preceding zone (0.40 vs 1.30 m/s; P < .001). SR conduction velocity decelerated by 69.5% (range 59.7%‐74.5%) before propagating into the isthmus area.Conclusion: Conduction slowing area during SR were related with the exit portion of the VT isthmuses.


  • Open Access

    Elongated ascending aorta predicts a short distance between his‐bundle potential recording site and coronary sinus ostium

    by Yuichi Momose, Kyoko Soejima, Akiko Ueda, Takahiro Arai, Masamichi Koyanagi, Yo Hagiwara, Ikuko Togashi, Yosuke Miwa, Kyoko Hoshida, Mutsumi Miyakoshi, et al.

    Structured Background: When performing catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT), it can be difficult to maintain a safe distance from the His recording site to avoid AV block in patients with a short distance between this recording site to the coronary sinus (CS) ostium (small triangle of Koch [TOK]). In this study, we sought to identify parameters predicting small TOK and test these parameters in patients undergoing AVNRT catheter ablation.Methods: Twenty‐eight patients who underwent catheter ablation of atrial fibrillation using a three‐dimensional (3D) electroanatomical mapping system (EAM) with computed tomography (CT) merge (23 males; mean age, 65.8±12.1 years) were included. The shortest distance between the CS ostium and His recording sites (His‐CSd) was measured on the EAM. Aortic (Ao) unfolding in chest X‐ray scan, Ao angle to the LV, Ao length, Ao to the right ventricular distance, size of the Valsalva in the CT scan, and parameters of echocardiogram were evaluated. The identified parameters were subsequently tested as predictors for small TOK in patients undergoing AVNRT ablation.Results: The size of TOK was associated with Ao length (r = −0.70, pr = −0.51, p<0.01), and Ao unfolding. In patients with AVNRT, only Ao unfolding predicted a smaller TOK.Conclusions: Small TOK was associated with longer Ao, larger LVDs, and Ao unfolding. Of these, Ao unfolding was associated with smaller TOK in patients with AVNRT.