ITIkuko Togashi

Ikuko Togashi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ikuko Togashi has a total of 34 co-authors. Here are the top co-authors by number of shared publications:

  • Kyoko Hoshida

    Department of Cardiovascular Medicine, Kyorin University , 6-20-2, Shinkawa, Mitaka-city, Tokyo 181-8611

    4 shared publications
  • Akiko Ueda

    Department of Cardiovascular Medicine, Kyorin University School of Medicine, Tokyo, Japan

    3 shared publications
  • Kyoko Soejima

    Department of Cardiovascular Medicine, Kyorin University School of Medicine , Mitaka , Japan

    2 shared publications
  • Kyoko Soejima

    Department of Cardiovascular Medicine, Kyorin University School of Medicine, Mitaka, Japan

    2 shared publications
  • Mika Tashiro

    Department of Cardiovascular Medicine, Kyorin University School of Medicine , Mitaka , Japan

    2 shared publications
  • Seiichiro Matsuo

    Department of Cardiovascular Medicine, Kyorin University , 6-20-2, Shinkawa, Mitaka-city, Tokyo 181-8611

    2 shared publications

Latest Publications

  • Open Access

    Wristwatch pulse wave monitoring: assessing daily activity post-catheter ablation for atrial fibrillation

    by Noriko Matsushita Nonoguchi, Kyoko Soejima, Yumi Katsume, Kyoko Hoshida, Ikuko Togashi, Ayumi Goda, Akiko Ueda, Seiichiro Matsuo, Toshiaki Sato, Yuichi Takano, et al.

    Aims: Atrial fibrillation (AF) leads to impaired exercise capacity, and catheter ablation (CA) for AF improves exercise capacity. However, the precise changes in daily activities after CA for AF remain unclear. The authors aimed to evaluate the changes in daily activities following CA for AF using a wristwatch-type pulse wave monitor (PWM), which tracks steps and exercise time, estimates burnt daily calories, and records sleep duration, in addition to establishing the rhythm diagnosis of AF or non-AF. Methods and results: One hundred and twenty-three patients with AF (97 paroxysmal, 26 persistent) wore a wristwatch-type PWM for 1 week duration at three time points: before, 1 month after, and 3 months after ablation. Daily activity data were compared. Steps did not change in both groups, and the number of burnt daily calories and total exercise time increased after CA in patients with paroxysmal AF (burnt daily calories: before, 1591 kcal/day; 1 month, 1688 kcal/day; and 3 months, 1624 kcal/day; P < 0.001 and exercise time: before, 45.8 min; 1 month, 51.2 min; and 3 months, 56.3 min; P = 0.023). Sleep hours significantly increased (paroxysmal AF: before, 6.8 h; 1 month, 7.1 h; and 3 months, 7.1 h; P = 0.039 and persistent AF: before, 6.0 h; 1 month, 7.0 h; and 3 months, 7.0 h; P = 0.007). Conclusion: Using a wristwatch-type PWM, we demonstrated changes in daily activities after CA in patients with AF. Trial registration number: jRCT1030210022.


  • Open Access

    Diverse QRS morphology reflecting variations in lead placement for left bundle branch area pacing

    by Toshiaki Sato, Ikuko Togashi, Hirotsugu Ikewaki, Takato Mohri, Yumi Katsume, Mika Tashiro, Noriko Nonoguchi, Kyoko Hoshida, Akiko Ueda, Seiichiro Matsuo, et al.

    Aims: Left bundle branch area pacing (LBBAP) is a potential alternative to His bundle pacing. This study aimed to investigate the impact of different septal locations of pacing leads on the diversity of QRS morphology during non-selective LBBAP. Methods and results: Non-selective LBBAP and left ventricular septal pacing (LVSP) were achieved in 50 and 21 patients with atrioventricular block, respectively. The electrophysiological properties of LBBAP and their relationship with the lead location were investigated. QRS morphology and axis showed broad variations during LBBAP. Echocardiography demonstrated a widespread distribution of LBBAP leads in the septum. During non-selective LBBAP, the qR-wave in lead V1 indicated that the primary location for pacing lead was the inferior septum (93%). The non-selective LBBAP lead was deployed deeper than the LVSP lead in the inferior septum. The Qr-wave in lead V1 with the inferior axis in aVF suggested pacing lead placement in the anterior septum. The penetration depth of the non-selective LBBAP lead in the anterior septum was significantly shallower than that in the inferior septum (72 ± 11 and 87 ± 8%, respectively). In lead V6, the deep S-wave indicated the time lag between the R-wave peak and the latest ventricular activation in the coronary sinus trunk, with pacemaker leads deployed closer to the left ventricular apex. Conclusion: Different QRS morphologies and axes were linked to the location of the non-selective LBBAP lead in the septum. Various lead deployments are feasible for LBBAP, allowing diversity in the conduction system capture in patients with atrioventricular block.


  • Open Access

    Fluoroscopic predictors of acceptable capture threshold during the implantation of the micra transcatheter pacing system

    by Ikuko Togashi, Toshiaki Sato, Akiko Maeda, Takato Mohri, Yumi Katsume, Mika Tashiro, Yuichi Momose, Noriko Nonoguchi, Kyoko Hoshida, Yosuke Miwa, et al.

    Introduction: Few predictors of low capture threshold before the deployment of the Micra transcatheter pacing system (Micra TPS) have been determined. We aimed to identify fluoroscopic predictors of an acceptable capture threshold before Micra TPS deployment.Methods: Sixty patients were successfully implanted with Micra TPS. Before deployment, gooseneck appearance of the catheter shaft was quantified using the angle between the tangent line of the shaft and the cup during diastole in the right anterior oblique (RAO) view. The direction of the device cup toward the ventricular septum was evaluated using the angle between the cup and the horizontal plane in the left anterior oblique (LAO) view.Results: Of the 95 deployments we evaluated, 56 achieved an acceptable capture threshold of ≤2.0 V at 0.24 ms. In this acceptable threshold group, the deflection angle of the gooseneck shaft was significantly larger and the device cup was placed more horizontally with a lower elevation angle compared with those in the high threshold group. A deflection angle of ≥6° and an elevation angle of ≤30° were identified as the predictors of an acceptable capture threshold after deployment. An acceptable capture threshold was achieved in 24/31 (77.4%) patients in whom either angle criterion was satisfied at the first deployment.Conclusions: Diastolic gooseneck appearance of the delivery catheter in the RAO view or near‐horizontal direction in the LAO view predicts an acceptable capture threshold after deployment. The shape of the delivery catheter before deployment should be evaluated using multiple fluoroscopic views to ensure successful implantation of Micra TPS.


  • Open Access

    Elongated ascending aorta predicts a short distance between his‐bundle potential recording site and coronary sinus ostium

    by Yuichi Momose, Kyoko Soejima, Akiko Ueda, Takahiro Arai, Masamichi Koyanagi, Yo Hagiwara, Ikuko Togashi, Yosuke Miwa, Kyoko Hoshida, Mutsumi Miyakoshi, et al.

    Structured Background: When performing catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT), it can be difficult to maintain a safe distance from the His recording site to avoid AV block in patients with a short distance between this recording site to the coronary sinus (CS) ostium (small triangle of Koch [TOK]). In this study, we sought to identify parameters predicting small TOK and test these parameters in patients undergoing AVNRT catheter ablation.Methods: Twenty‐eight patients who underwent catheter ablation of atrial fibrillation using a three‐dimensional (3D) electroanatomical mapping system (EAM) with computed tomography (CT) merge (23 males; mean age, 65.8±12.1 years) were included. The shortest distance between the CS ostium and His recording sites (His‐CSd) was measured on the EAM. Aortic (Ao) unfolding in chest X‐ray scan, Ao angle to the LV, Ao length, Ao to the right ventricular distance, size of the Valsalva in the CT scan, and parameters of echocardiogram were evaluated. The identified parameters were subsequently tested as predictors for small TOK in patients undergoing AVNRT ablation.Results: The size of TOK was associated with Ao length (r = −0.70, pr = −0.51, p<0.01), and Ao unfolding. In patients with AVNRT, only Ao unfolding predicted a smaller TOK.Conclusions: Small TOK was associated with longer Ao, larger LVDs, and Ao unfolding. Of these, Ao unfolding was associated with smaller TOK in patients with AVNRT.