JPJosé Miguel Paiva

José Miguel Paiva

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


José Miguel Paiva has a total of 83 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Subclinical Changes in Cardiac Functional Parameters as Determined by Cardiovascular Magnetic Resonance (CMR) Imaging in Sleep Apnea and Snoring: Findings from UK Biobank

    by Adrian Curta, Holger Hetterich, Regina Schinner, Aaron M. Lee, Wieland Sommer, Nay Aung, Mihir M. Sanghvi, Kenneth Fung, Elena Lukaschuk, Jackie A. Cooper, et al.

    Background and Objectives: Obstructive sleep apnea (OSA) is a common disorder with an increased risk for left ventricular and right ventricular dysfunction. Most studies to date have examined populations with manifest cardiovascular disease using echocardiography to analyze ventricular dysfunction with little or no reference to ventricular volumes or myocardial mass. Our aim was to explore these parameters with cardiac MRI. We hypothesized that there would be stepwise increase in left ventricular mass and right ventricular volumes from the unaffected, to the snoring and the OSA group. Materials and Methods: We analyzed cardiac MRI data from 4978 UK Biobank participants free from cardiovascular disease. Participants were allocated into three cohorts: with OSA, with self-reported snoring and without OSA or snoring (n = 118, 1886 and 2477). We analyzed cardiac parameters from balanced cine-SSFP sequences and indexed them to body surface area. Results: Patients with OSA were mostly males (47.3% vs. 79.7%; p < 0.001) with higher body mass index (25.7 ± 4.0 vs. 31.3 ± 5.3 kg/m²; p < 0.001) and higher blood pressure (135 ± 18 vs. 140 ± 17 mmHg; p = 0.012) compared to individuals without OSA or snoring. Regression analysis showed a significant effect for OSA in left ventricular end-diastolic index (LVEDVI) (β = −4.9 ± 2.4 mL/m²; p = 0.040) and right ventricular end-diastolic index (RVEDVI) (β = −6.2 ± 2.6 mL/m²; p = 0.016) in females and for right ventricular ejection fraction (RVEF) (β = 1.7 ± 0.8%; p = 0.031) in males. A significant effect was discovered in snoring females for left ventricular mass index (LVMI) (β = 3.5 ± 0.9 g/m²; p < 0.001) and in males for left ventricular ejection fraction (LVEF) (β = 1.0 ± 0.3%; p = 0.001) and RVEF (β = 1.2 ± 0.3%; p < 0.001). Conclusion: Our study suggests that OSA is highly underdiagnosed and that it is an evolving process with gender specific progression. Females with OSA show significantly lower ventricular volumes while males with snoring show increased ejection fractions which may be an early sign of hypertrophy. Separate prospective studies are needed to further explore the direction of causality.


  • Open Access

    Poor Bone Quality is Associated With Greater Arterial Stiffness: Insights From the UK Biobank

    by Zahra Raisi-Estabragh, Luca Biasiolli, Jackie Cooper, Nay Aung, Kenneth Fung, José M Paiva, Mihir M Sanghvi, Ross J Thomson, Elizabeth Curtis, Julien Paccou, et al.

    Osteoporosis and ischemic heart disease (IHD) represent important public health problems. Existing research suggests an association between the two conditions beyond that attributable to shared risk factors, with a potentially causal relationship. In this study, we tested the association of bone speed of sound (SOS) from quantitative heel ultrasound with (i) measures of arterial compliance from cardiovascular magnetic resonance (aortic distensibility [AD]); (ii) finger photoplethysmography (arterial stiffness index [ASI]); and (iii) incident myocardial infarction and IHD mortality in the UK Biobank cohort. We considered the potential mediating effect of a range of blood biomarkers and cardiometabolic morbidities and evaluated differential relationships by sex, menopause status, smoking, diabetes, and obesity. Furthermore, we considered whether associations with arterial compliance explained association of SOS with ischemic cardiovascular outcomes. Higher SOS was associated with lower arterial compliance by both ASI and AD for both men and women. The relationship was most consistent with ASI, likely relating to larger sample size available for this variable (n = 159,542 versus n = 18,229). There was no clear evidence of differential relationship by menopause, smoking, diabetes, or body mass index (BMI). Blood biomarkers appeared important in mediating the association for both men and women, but with different directions of effect and did not fully explain the observed effects. In fully adjusted models, higher SOS was associated with significantly lower IHD mortality in men, but less robustly in women. The association of SOS with ASI did not explain this observation. In conclusion, our findings support a positive association between bone and vascular health with consistent patterns of association in men and women. The underlying mechanisms are complex and appear to vary by sex. © 2020 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).


  • Open Access

    3.2 First Genome-Wide Association Study of Cardiovascular Magnetic Resonance Derived Aortic Distensibility Reveals 7 Loci

    by Kenneth Fung, Luca Biasiolli, Evan Hann, Julia Ramirez, Elena Lukaschuk, Nay Aung, Jose Paiva, Konrad Werys, Mihir Sanghvi, Ross Thomson, et al.


  • Open Access

    Automated Quality Control in Image Segmentation: Application to the UK Biobank Cardiac MR Imaging Study

    by Robert Robinson, Vanya V. Valindria, Wenjia Bai, Ozan Oktay, Bernhard Kainz, Hideaki Suzuki, Mihir M. Sanghvi, Nay Aung, José Miguel Paiva, Filip Zemrak, et al.

    Background: The trend towards large-scale studies including population imaging poses new challenges in terms of quality control (QC). This is a particular issue when automatic processing tools, e.g. image segmentation methods, are employed to derive quantitative measures or biomarkers for later analyses. Manual inspection and visual QC of each segmentation isn't feasible at large scale. However, it's important to be able to automatically detect when a segmentation method fails so as to avoid inclusion of wrong measurements into subsequent analyses which could lead to incorrect conclusions. Methods: To overcome this challenge, we explore an approach for predicting segmentation quality based on Reverse Classification Accuracy, which enables us to discriminate between successful and failed segmentations on a per-cases basis. We validate this approach on a new, large-scale manually-annotated set of 4,800 cardiac magnetic resonance scans. We then apply our method to a large cohort of 7,250 cardiac MRI on which we have performed manual QC. Results: We report results used for predicting segmentation quality metrics including Dice Similarity Coefficient (DSC) and surface-distance measures. As initial validation, we present data for 400 scans demonstrating 99% accuracy for classifying low and high quality segmentations using predicted DSC scores. As further validation we show high correlation between real and predicted scores and 95% classification accuracy on 4,800 scans for which manual segmentations were available. We mimic real-world application of the method on 7,250 cardiac MRI where we show good agreement between predicted quality metrics and manual visual QC scores. Conclusions: We show that RCA has the potential for accurate and fully automatic segmentation QC on a per-case basis in the context of large-scale population imaging as in the UK Biobank Imaging Study.

  • Open Access

    Automated quality control in image segmentation: application to the UK Biobank cardiovascular magnetic resonance imaging study

    by Robert Robinson, Vanya V. Valindria, Wenjia Bai, Ozan Oktay, Bernhard Kainz, Hideaki Suzuki, Mihir M. Sanghvi, Nay Aung, José Miguel Paiva, Filip Zemrak, et al.


  • Top Cited Papers
    Open Access

    Automated cardiovascular magnetic resonance image analysis with fully convolutional networks

    by Wenjia Bai, Matthew Sinclair, Giacomo Tarroni, Ozan Oktay, Martin Rajchl, Ghislain Vaillant, Aaron M. Lee, Nay Aung, Elena Lukaschuk, Mihir M. Sanghvi, et al.


  • Open Access

    The impact of cardiovascular risk factors on cardiac structure and function: Insights from the UK Biobank imaging enhancement study

    by Steffen E Petersen, Mihir M Sanghvi, Nay Aung, Jackie A Cooper, José Miguel Paiva, Filip Zemrak, Kenneth Fung, Elena Lukaschuk, Aaron M Lee, Valentina Carapella, et al.

    The UK Biobank is a large-scale population-based study utilising cardiovascular magnetic resonance (CMR) to generate measurements of atrial and ventricular structure and function. This study aimed to quantify the association between modifiable cardiovascular risk factors and cardiac morphology and function in individuals without known cardiovascular disease. Age, sex, ethnicity (non-modifiable) and systolic blood pressure, diastolic blood pressure, smoking status, exercise, body mass index (BMI), high cholesterol, diabetes, alcohol intake (modifiable) were considered important cardiovascular risk factors. Multivariable regression models were built to ascertain the association of risk factors on left ventricular (LV), right ventricular (RV), left atrial (LA) and right atrial (RA) CMR parameters. 4,651 participants were included in the analysis. All modifiable risk factors had significant effects on differing atrial and ventricular parameters. BMI was the modifiable risk factor most consistently associated with subclinical changes to CMR parameters, particularly in relation to higher LV mass (+8.3% per SD [4.3 kg/m2], 95% CI: 7.6 to 8.9%), LV (EDV: +4.8% per SD, 95% CI: 4.2 to 5.4%); ESV: +4.4% per SD, 95% CI: 3.5 to 5.3%), RV (EDV: +5.3% per SD, 95% CI: 4.7 to 5.9%; ESV: +5.4% per SD, 95% CI: 4.5 to 6.4%) and LA maximal (+8.6% per SD, 95% CI: 7.4 to 9.7%) volumes. Increases in SBP were associated with higher LV mass (+6.8% per SD, 95% CI: 5.9 to 7.7%), LV (EDV: +4.5% per SD, 95% CI: 3.6 to 5.4%; ESV: +2.0% per SD, 95% CI: 0.8 to 3.3%) volumes. The presence of diabetes or high cholesterol resulted in smaller volumes and lower ejection fractions. Modifiable risk factors are associated with subclinical alterations in structure and function in all four cardiac chambers. BMI and systolic blood pressure are the most important modifiable risk factors affecting CMR parameters known to be linked to adverse outcomes.


  • Open Access

    Fully-automated left ventricular mass and volume MRI analysis in the UK Biobank population cohort: evaluation of initial results

    by Avan Suinesiaputra, Mihir M. Sanghvi, Nay Aung, Jose Miguel Paiva, Filip Zemrak, Kenneth Fung, Elena Lukaschuk, Aaron M. Lee, Valentina Carapella, Young Jin Kim, et al.

    UK Biobank, a large cohort study, plans to acquire 100,000 cardiac MRI studies by 2020. Although fully-automated left ventricular (LV) analysis was performed in the original acquisition, this was not designed for unsupervised incorporation into epidemiological studies. We sought to evaluate automated LV mass and volume (Siemens syngo InlineVF versions D13A and E11C), against manual analysis in a substantial sub-cohort of UK Biobank participants. Eight readers from two centers, trained to give consistent results, manually analyzed 4874 UK Biobank cases for LV end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF) and LV mass (LVM). Agreement between manual and InlineVF automated analyses were evaluated using Bland–Altman analysis and the intra-class correlation coefficient (ICC). Tenfold cross-validation was used to establish a linear regression calibration between manual and InlineVF results. InlineVF D13A returned results in 4423 cases, whereas InlineVF E11C returned results in 4775 cases and also reported LVM. Rapid visual assessment of the E11C results found 178 cases (3.7%) with grossly misplaced contours or landmarks. In the remaining 4597 cases, LV function showed good agreement: ESV −6.4 ± 9.0 ml, 0.853 (mean ± SD of the differences, ICC) EDV −3.0 ± 11.6 ml, 0.937; SV 3.4 ± 9.8 ml, 0.855; and EF 3.5 ± 5.1%, 0.586. Although LV mass was consistently overestimated (29.9 ± 17.0 g, 0.534) due to larger epicardial contours on all slices, linear regression could be used to correct the bias and improve accuracy. Automated InlineVF results can be used for case-control studies in UK Biobank, provided visual quality control and linear bias correction are performed. Improvements between InlineVF D13A and InlineVF E11C show the field is rapidly advancing, with further improvements expected in the near future.


  • Top Cited Papers
    Open Access

    Reference ranges for cardiac structure and function using cardiovascular magnetic resonance (CMR) in Caucasians from the UK Biobank population cohort

    by Steffen E. Petersen, Nay Aung, Mihir M. Sanghvi, Filip Zemrak, Kenneth Fung, Jose Miguel Paiva, Jane M. Francis, Mohammed Y. Khanji, Elena Lukaschuk, Aaron M. Lee, et al.