Alexander Vladimirovich Radionov
Research Subjects
Alexander Vladimirovich Radionov has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Aleksandr Dmitrievich Podoltsev
Institute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi, Kyiv, 03057, Ukraine
3 shared publications - Yury Dikansky
North-Caucasus Federal University
3 shared publications A A Radionova
LLC Ferrohydrodynamica, Mykolaiv, Ukraine
2 shared publicationsA D Podoltsev
NASU Institute of Electrodynamics, Kyiv, Ukraine
2 shared publicationsA. G. Ispiryan
North-Caucasus Federal University
2 shared publicationsD. V. Gladkikh
North Caucasus Federal University
2 shared publications
Latest Publications
- 25 August 2025
- Published by Wroclaw Board of Scientific Technical Societies Federation NOT in Journal of Machine Engineering
- p. 60-69
Magnetophoretic Motion of Micron-Sized Magnetic Particles in the Working Gap of a Magnetic Fluid Seal.
The operational experience of bearing units in technological equipment has been analyzed. The use of magnetic fluid seals to enhance the reliability and failure-free operation of equipment has been justified. A method for expanding the application range of seals by adding micron-sized magnetic particles to the working magnetic fluid, in accordance with Ukrainian Patent No. 106420, has been proposed. The distribution of magnetic induction in the active zone of the seal with an increased gap (0.8 mm) has been calculated for two cases—with and without a defect on the shaft surface. A regime where micron-sized magnetic particles are additionally introduced into the working magnetic fluid has been considered. The non-uniform distribution of the field and the vector quantity of the magnetic force acting on microscopic particles in the magnetic fluid has been demonstrated. The distribution of the velocity of these particles under the influence of this force in the active zone of the seal, both with and without a defect on the shaft, has been obtained through calculations. It has been shown that these particles concentrate in areas with non-uniform fields—in the angular zones of the teeth of the magnetic system and near the defect on the shaft. The characteristic transition time for particles with diameters of d_p=0,1 ;1 and 10 µm is 630, 6.3, and 0.063 minutes, respectively.
- 25 August 2025
- Published by Wroclaw Board of Scientific Technical Societies Federation NOT in Journal of Machine Engineering
- p. 60-69
Magnetophoretic Motion of Micron-Sized Magnetic Particles in the Working Gap of a Magnetic Fluid Seal.
The operational experience of bearing units in technological equipment has been analyzed. The use of magnetic fluid seals to enhance the reliability and failure-free operation of equipment has been justified. A method for expanding the application range of seals by adding micron-sized magnetic particles to the working magnetic fluid, in accordance with Ukrainian Patent No. 106420, has been proposed. The distribution of magnetic induction in the active zone of the seal with an increased gap (0.8 mm) has been calculated for two cases—with and without a defect on the shaft surface. A regime where micron-sized magnetic particles are additionally introduced into the working magnetic fluid has been considered. The non-uniform distribution of the field and the vector quantity of the magnetic force acting on microscopic particles in the magnetic fluid has been demonstrated. The distribution of the velocity of these particles under the influence of this force in the active zone of the seal, both with and without a defect on the shaft, has been obtained through calculations. It has been shown that these particles concentrate in areas with non-uniform fields—in the angular zones of the teeth of the magnetic system and near the defect on the shaft. The characteristic transition time for particles with diameters of d_p=0,1 ;1 and 10 µm is 630, 6.3, and 0.063 minutes, respectively.
- Open Access
- 5 May 2022
- Published by Publishing House Helvetica (Publications) in Bulletin of Sumy National Agrarian University. The series: Mechanization and Automation of Production Processes
- No. 2 (44),p. 35-40
ВПЛИВ ОРГАНІЗАЦІЇ ТЕХНІЧНОГО СЕРВІСУ НА ЕКОЛОГІЧНУ БЕЗПЕКУ СИСТЕМИ «ЛЮДИНА-МАШИНА-ДОВКІЛЛЯ»
В статті розглянуто питання підвищення екологічної безпеки технічних систем шляхом вдосконалення їх технічного сервісу. Розглянуто вплив комплексу заходів з техніного обслуговування обладнання на надійність функціонування технічних систем. Приділена увага питанням модернізації технологічного устаткування, що забезпечує поліпшення властивостей системи в жорстких умовах існуючої конструкції. Представлено досвід модернізаціїї електродвигунів шляхом застосування магніторідинних герметизирующих комплексів. Запропоновано варіант модернізації підшипникових вузлів насосних та компресорних агрегатів шляхов формування комплексних електроіскрових покриттів на елементах підшипників ковзання.
- 5 May 2022
- Published by Publishing House Helvetica (Publications) in Bulletin of Sumy National Agrarian University. The series: Mechanization and Automation of Production Processes
- No. 2 (44),p. 35-40
Open AccessВПЛИВ ОРГАНІЗАЦІЇ ТЕХНІЧНОГО СЕРВІСУ НА ЕКОЛОГІЧНУ БЕЗПЕКУ СИСТЕМИ «ЛЮДИНА-МАШИНА-ДОВКІЛЛЯ»
В статті розглянуто питання підвищення екологічної безпеки технічних систем шляхом вдосконалення їх технічного сервісу. Розглянуто вплив комплексу заходів з техніного обслуговування обладнання на надійність функціонування технічних систем. Приділена увага питанням модернізації технологічного устаткування, що забезпечує поліпшення властивостей системи в жорстких умовах існуючої конструкції. Представлено досвід модернізаціїї електродвигунів шляхом застосування магніторідинних герметизирующих комплексів. Запропоновано варіант модернізації підшипникових вузлів насосних та компресорних агрегатів шляхов формування комплексних електроіскрових покриттів на елементах підшипників ковзання.
- Open Access
- 1 January 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1741 (1) , 012037
Magnetic field in the core of a magnetic fluid seal taking magnetic structural elements into account
According to the results of the finite element analysis of the magnetic field of the liquid metal seal designed to protect the bearing assembly from external aggressive influences, it is shown that its mounting directly on the bearing shield having magnetic properties leads to an increase in magnetic fluxes of scattering and to a decrease in the peak value of magnetic induction in the working the gap from 1, 6 T to 1,1 T., i.e. to a decrease of 31%. The use of a non-magnetic insert between the seal and the bearing assembly allows this induction to be increased. The dependence of this induction on the thickness of the insert is given, which makes it possible to choose its rational value when installing the seal. It is shown that the use of an additional permanent magnet located in the area of this insert allows one to increase the peak value of magnetic induction in the working gap from 1.3 T to 1.75 T and, as a result, improve the performance of the seal.
- 1 January 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1741 (1) , 012037
Open AccessMagnetic field in the core of a magnetic fluid seal taking magnetic structural elements into account
According to the results of the finite element analysis of the magnetic field of the liquid metal seal designed to protect the bearing assembly from external aggressive influences, it is shown that its mounting directly on the bearing shield having magnetic properties leads to an increase in magnetic fluxes of scattering and to a decrease in the peak value of magnetic induction in the working the gap from 1, 6 T to 1,1 T., i.e. to a decrease of 31%. The use of a non-magnetic insert between the seal and the bearing assembly allows this induction to be increased. The dependence of this induction on the thickness of the insert is given, which makes it possible to choose its rational value when installing the seal. It is shown that the use of an additional permanent magnet located in the area of this insert allows one to increase the peak value of magnetic induction in the working gap from 1.3 T to 1.75 T and, as a result, improve the performance of the seal.
- Open Access
- 26 October 2018
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Mechanics and Advanced Technologies
- Vol. 83 (2)
The specific features of high-velocity magnetic fluid sealing complexes
The specific features of high-velocity magnetic fluid sealing complexes
- 26 October 2018
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Mechanics and Advanced Technologies
- Vol. 83 (2)
Open AccessThe specific features of high-velocity magnetic fluid sealing complexes
The specific features of high-velocity magnetic fluid sealing complexes
- Open Access
- 15 May 2018
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2018 (4) , 14-18
A THIN ELECTROMAGNETIC SHIELD OF A COMPOSITE STRUCTURE MADE ON THE BASIS OF A MAGNETIC FLUID
Joomla! - the dynamic portal engine and content management system
- 15 May 2018
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2018 (4) , 14-18
Open AccessA THIN ELECTROMAGNETIC SHIELD OF A COMPOSITE STRUCTURE MADE ON THE BASIS OF A MAGNETIC FLUID
Joomla! - the dynamic portal engine and content management system
- 1 January 2018
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 63 (1) , 57-61
Magnetization of Paraffin-Based Magnetic Nanocolloids
Using paraffin-based magnetic nanocolloids as an example, the reasons for maxima in the temperature dependence of the magnetic susceptibility of magnetic colloids have been discussed. The behavior of...
- 1 January 2018
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 63 (1) , 57-61
Magnetization of Paraffin-Based Magnetic Nanocolloids
Using paraffin-based magnetic nanocolloids as an example, the reasons for maxima in the temperature dependence of the magnetic susceptibility of magnetic colloids have been discussed. The behavior of...
- Open Access
- 30 August 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 233 (1) , 012038
Express - method for determining the quality of a magnetic fluid for operation in the working gap of a magnetic fluid seal
The reliability of the magnetic fluid seals operation is reduced to an assessment of the quality control of a magnetic fluid associated with its stability in the working gap of the seal in many cases. The previously developed relatively simple method for express analysis of the quality of a magnetic fluid is supplemented by studying the dependence of the dynamic characteristics of a nanofluid on the size of magnetite particles. This method can be easily implemented in an industrial enterprise using devices with a magnetic fluid.
- 30 August 2017
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 233 (1) , 012038
Open AccessExpress - method for determining the quality of a magnetic fluid for operation in the working gap of a magnetic fluid seal
The reliability of the magnetic fluid seals operation is reduced to an assessment of the quality control of a magnetic fluid associated with its stability in the working gap of the seal in many cases. The previously developed relatively simple method for express analysis of the quality of a magnetic fluid is supplemented by studying the dependence of the dynamic characteristics of a nanofluid on the size of magnetite particles. This method can be easily implemented in an industrial enterprise using devices with a magnetic fluid.
- 23 November 2015
- Published by Springer Nature in Chemical and Petroleum Engineering
- Vol. 51 (7-8) , 481-486
Application of Magnetic Fluid Seals for Improving Reliability of Air Coolers
- 23 November 2015
- Published by Springer Nature in Chemical and Petroleum Engineering
- Vol. 51 (7-8) , 481-486
Application of Magnetic Fluid Seals for Improving Reliability of Air Coolers
- 16 August 2015
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 60 (8) , 1204-1207
On the Nature of the maximum in the temperature dependence of magnetic liquid susceptibility
The temperature dependence of the real part of complex magnetic susceptibility of magnetic colloid nanosystems based on glycerol and two samples of fine magnetite powder is studied. The results are...
- 16 August 2015
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 60 (8) , 1204-1207
On the Nature of the maximum in the temperature dependence of magnetic liquid susceptibility
The temperature dependence of the real part of complex magnetic susceptibility of magnetic colloid nanosystems based on glycerol and two samples of fine magnetite powder is studied. The results are...
- 20 March 2015
- Published by Pleiades Publishing Ltd in Colloid Journal
- Vol. 77 (2) , 196-201
A magnetic fluid for operation in strong gradient fields
The properties of a magnetic fluid based on colloidal magnetite and VM-3 vacuum oil have been experimentally studied. The fluid is designed for a long-term operation in strong gradient magnetic fields. A variant of magneto-granulometric analysis has been proposed that makes it possible to determine the average magnetic moment, variance of magnetic moments, and number density of particles with no a priori assumptions of the particle size distribution. Magneto-granulometric and cluster analyses of the magnetic fluid have been carried out. It has been shown that individual particles with an average diameter of the magnetic core of 7 nm, which is markedly smaller than those in common commercial fluids, prevail in the studied solution. The volume concentration of multiparticle clusters is also low; their total contribution to the initial magnetic susceptibility of the fluid only slightly exceeds 3%. The small particle sizes and the low cluster concentration provide the colloidal solution with a high stability in a strong magnetic field and a centrifugal force field at a rather high saturation magnetization of the solution.
- 20 March 2015
- Published by Pleiades Publishing Ltd in Colloid Journal
- Vol. 77 (2) , 196-201
A magnetic fluid for operation in strong gradient fields
The properties of a magnetic fluid based on colloidal magnetite and VM-3 vacuum oil have been experimentally studied. The fluid is designed for a long-term operation in strong gradient magnetic fields. A variant of magneto-granulometric analysis has been proposed that makes it possible to determine the average magnetic moment, variance of magnetic moments, and number density of particles with no a priori assumptions of the particle size distribution. Magneto-granulometric and cluster analyses of the magnetic fluid have been carried out. It has been shown that individual particles with an average diameter of the magnetic core of 7 nm, which is markedly smaller than those in common commercial fluids, prevail in the studied solution. The volume concentration of multiparticle clusters is also low; their total contribution to the initial magnetic susceptibility of the fluid only slightly exceeds 3%. The small particle sizes and the low cluster concentration provide the colloidal solution with a high stability in a strong magnetic field and a centrifugal force field at a rather high saturation magnetization of the solution.