FMFederico Morosato

Federico Morosato

*This is an algorithmically generated author record based on publicly available information.

Federico Morosato has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Long-term availability of powered exoskeleton for ambulation in domestic context: A cross-sectional study to assess safety, usage pattern, and satisfaction after long-term use

    by Andrea Giovanni Cutti, Federico Morosato, Valeria Gazzotti, Gregorio Teti, Antonella Miccio, Patrizio Rossi, Emanuele Gruppioni

    Cross-sectional study. To quantify the safety, usage pattern, and satisfaction of seven subjects with paraplegia after prolonged home use of a commercial powered overground exoskeleton. Centro Protesi Inail, the prosthetic centre of the Italian workers' compensation authority. The participants were recalled for a single-day assessment. Five domains were investigated: i. occurrences of adverse events. ii. Active use, usability, and satisfaction: Number of gait steps and stair steps with exoskeleton, System Usability Scale (SUS), Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST). iii. Health status and independence: Short Form-36 (SF-36), Patient Health Questionnaire-9 (PHQ-9), General Anxiety Disorder Scale (GAD-7), VO2 consumption associated to a sub-maximal arm crank ergometer test, Modified Ashworth Scale (MAS), Jobe's test and Speed's test, Spinal Cord Injury Measure (SCIM). iv. Perceived benefits: Self-perceived pain severity (VAS scale), Self-perceived bowel and bladder management (5-Likert scale). v. Performance: 6 min Walking Test (6MWT), 10 Meters Walking Test (10MWT). Most recruited subjects were able to use the exoskeleton actively and safely throughout the observation period, experiencing an overall improvement across all domains of investigation. In one case, the ambulation time was lower due to the unavailability of the caregiver. Home supply of powered exoskeleton for ambulation could be part of a rehabilitation program to support individuals with paraplegia in their daily life. However, the presence of a qualified caregiver emerged as dominant factor for technology abandonment.


  • Open Access

    Correction: Cutti et al. The Effect of the Poly-Articulated Prosthetic Hand on Shoulder and Trunk Compensatory Movements during Manipulation and Grasp Tasks. Prosthesis 2023, 5, 182–196

    by Andrea Giovanni Cutti, Federico Morosato, Emanuele Gruppioni, Gregorio Teti, Lorenzo De Michieli, Cosimo Gentile

    “Institutional Review Board Statement” was not included in the original publication


  • A retrospective multidimensional comparison of microprocessor and mechanical knee users: Analysis of quality of life and satisfaction with the prosthesis

    by Andrea G Cutti, Federico Morosato, Cosimo Gentile, Gregorio Teti, Emanuele Lettieri, Emanuele Gruppioni

    Background: Despite the demonstrated greater efficacy of microprocessor knees (MPK) over mechanical knees (MK), the latter is still widely used by persons with transfemoral amputation. Besides motivations related to local insurance policies, quality of life (QoL) and satisfaction with the prosthesis play a key role in user preference. Objective: The aim of this study is to compare QoL and satisfaction in a large sample of MPK and MK users and to assess how these outcomes are explained by clinical and demographic characteristics. Study Design: Retrospective study. Methods: The study was conducted on 75 MPK and 60 MK users. Quality of life was assessed using the EuroQoL Five Dimensions and the EuroQoL Visual Analog Scale questionnaires. Satisfaction was assessed with the Satisfaction with Prosthesis questionnaire. All 3 instruments were self-administered. Univariate and multivariate regression analyses were conducted thereafter. Results: The difference in satisfaction between MPK and MK users was not statistically significant. Significant differences were observed instead for QoL. From the univariate regression analysis, 6 factors were significant predictors of QoL and satisfaction. On multivariate analysis, the number of significant factors was reduced to 3, namely knee type, age at the first prosthesis, and experience with prosthesis. Type of knee and age at the first prosthesis significantly predicted QoL scores, explaining 12% of EuroQoL Five Dimensions and 25% of EuroQoL Visual Analog Scale variances. Age at the first prosthesis and experience with prosthesis predicted Satisfaction with Prosthesis scores in the multivariate model, explaining 25% of the variance. Conclusions: MPK affects QoL but not satisfaction, which is positively driven by patients’ experience with prosthesis and negatively affected by the age at the time of the first prosthesis.


  • Open Access

    A Workflow for Studying the Stump–Socket Interface in Persons with Transtibial Amputation through 3D Thermographic Mapping

    by Andrea Giovanni Cutti, Federico Morosato, Cosimo Gentile, Francesca Gariboldi, Giovanni Hamoui, Maria Grazia Santi, Gregorio Teti, Emanuele Gruppioni

    The design and fitting of prosthetic sockets can significantly affect the acceptance of an artificial limb by persons with lower limb amputations. Clinical fitting is typically an iterative process, which requires patients’ feedback and professional assessment. When feedback is unreliable due to the patient’s physical or psychological conditions, quantitative measures can support decision-making. Specifically, monitoring the skin temperature of the residual limb can provide valuable information regarding unwanted mechanical stresses and reduced vascularization, which can lead to inflammation, skin sores and ulcerations. Multiple 2D images to examine a real-life 3D limb can be cumbersome and might only offer a partial assessment of critical areas. To overcome these issues, we developed a workflow for integrating thermographic information on the 3D scan of a residual limb, with intrinsic reconstruction quality measures. Specifically, workflow allows us to calculate a 3D thermal map of the skin of the stump at rest and after walking, and summarize this information with a single 3D differential map. The workflow was tested on a person with transtibial amputation, with a reconstruction accuracy lower than 3 mm, which is adequate for socket adaptation. We expect the workflow to improve socket acceptance and patients’ quality of life.


  • Restoration of natural thermal sensation in upper-limb amputees

    by Francesco Iberite, Jonathan Muheim, Outman Akouissi, Simon Gallo, Giulio Rognini, Federico Morosato, André Clerc, Magnus Kalff, Emanuele Gruppioni, Silvestro Micera, et al.

    The use of hands for gathering rich sensory information is essential for proper interaction with the environment; therefore, the restoration of sensation is critical for reestablishing the sense of embodiment in hand amputees. Here, we show that a noninvasive wearable device can be used to provide thermal sensations on amputees’ phantom hands. The device delivers thermal stimuli to specific regions of skin on their residual limb. These sensations were phenomenologically similar to those on the intact limbs and were stable over time. Using the device, the subjects could successfully exploit the thermal phantom hand maps to detect and discriminate different thermal stimuli. The use of a wearable device that provides thermal sensation can increase the sense of embodiment and improve life quality in hand amputees.


  • Open Access

    The Effect of the Poly-Articulated Prosthetic Hand on Shoulder and Trunk Compensatory Movements during Manipulation and Grasp Tasks

    by Andrea Giovanni Cutti, Federico Morosato, Emanuele Gruppioni, Gregorio Teti, Lorenzo De Michieli, Cosimo Gentile

    Conventional myoelectric prosthetic hands only offer a basic tri-digital pinch. Transradial amputees need to compensate for this lack of function with altered kinematics at the shoulder and trunk that might expose them to an increased risk of musculoskeletal injuries. A poly-articulated prosthetic hand may reduce the physical compensatory movements and close the gap between the sound and the prosthetic side. Six male transradial amputees completed four standardized reach-and-grasp activities with their tri-digital, poly-articulated and sound side hands. Trunk, shoulder girdle, scapula and humerus kinematics were measured with an optoelectronic system. Differences between hands were analyzed in terms of the amplitude of motion, the duration of the altered kinematics over the motion cycle, peak-to-peak amplitude and time to complete the activity. An overall score was defined, which assigned three points when the kinematics of a joint angle was altered for over 41% of the motion cycle, two points between 11 ÷ 40% and one point between 1 ÷ 10%; thus, a lower score indicates less variation from normal kinematics. Despite no changes in times, tri-digital vs. sound hand scored 93 points, tri-digital vs. poly-articulated hands scored 49 and poly-articulated vs. sound hand scored 28, supporting the hypotheses of the poly-articulated hand positively affects shoulder and trunk kinematics.


  • Factors influencing the self-perceived mobility of active unilateral lower limb amputees assessed with the Prosthetic Mobility Questionnaire: a brief report

    by Federico Morosato, Cosimo Gentile, Arianna Di Bernardo, Emanuele Gruppioni, Antonella Miccio

    The Prosthetic Mobility Questionnaire (PMQ 2.0) represents a reliable solution for evaluating amputees’ self-perceived mobility. The study aimed to evaluate the perceived mobility of middle-aged users with a traumatic amputation using the PMQ 2.0 and to assess the influence of age, stump and phantom limb pain, amputation level, time since amputation, and prosthesis use on it. Fifty subjects were recruited. The median value of the score was higher than previously published reference values, reflecting the ‘active’ mobility status of the sample. The hours of prosthesis use per day explained about 21% of the variance of the questionnaire score and was a significant predictor of perceived mobility. Reference values for the recently developed PMQ 2.0 survey and relative to active, traumatic amputees were reported. As prosthesis use was a significant predictor of the amputees’ perceived mobility, prolonged use of the artificial limb should be always encouraged in clinical practice.


  • Open Access

    Primary Stability of Revision Acetabular Reconstructions Using an Innovative Bone Graft Substitute: A Comparative Biomechanical Study on Cadaveric Pelvises

    by Federico Morosato, Francesco Traina, Ronja A. Schierjott, Georg Hettich, Thomas M. Grupp, Luca Cristofolini

    Hip implant failure is mainly due to aseptic loosening of the cotyle and is typically accompanied by defects in the acetabular region. Revision surgery aims to repair such defects before implantation by means of reconstruction materials, whose morselized bone graft represents the gold standard. Due to the limited availability of bone tissue, synthetic substitutes are also used. The aim of this study was to evaluate if a synthetic fully resorbable tri-calcium phosphate-based substitute can provide adequate mechanical stability when employed to restore severe, contained defects, in comparison with morselized bone graft. Five cadaveric pelvises were adopted, one side was reconstructed with morselized bone graft and the other with the synthetic substitute, consisting of dense calcium phosphate granules within a collagen matrix. During the biomechanical test, cyclic load packages of increasing magnitude were applied to each specimen until failure. Bone/implant motions were measured through Digital Image Correlation and were expressed in terms of permanent and inducible translations and rotations. The reconstruction types exhibited a similar behavior, consisting of an initial settling trend followed by failure as bone fracture (i.e., no failure of the reconstruction material). When 2.2 Body Weight was applied, the permanent translations were not significantly different between the two reconstructions (p = 0.06–1.0) and were below 1.0 mm. Similarly, the inducible translations did not differ significantly (p = 0.06–1.0) and were below 0.160 mm. Rotations presented the same order of magnitude but were qualitatively different. Overall, the synthetic substitute provided adequate mechanical stability in comparison with morselized bone graft, thus representing a reliable alternative to treat severe, contained acetabular defects.


  • Standardization of hemipelvis alignment for in vitro biomechanical testing

    by Federico Morosato, Francesco Traina, Luca Cristofolini

    Although in vitro biomechanical tests are regularly performed, the definition of a suitable reference frame for hemipelvic specimens is still a challenge. The aims of the present study were to: (i) define a reference frame for the human hemipelvis suitable for in vitro applications, based on robust anatomical landmarks; (ii) identify the alignment of a hemipelvis based on the alignment of a whole pelvis (including right/left and male/female differences); (iii) identify the relative alignment of the proposed in vitro reference frame with respect to a reference frame commonly used in gait analysis; (iv) create an in vitro alignment procedure easy, robust and inexpensive; (v) quantify the intra‐operator repeatability and inter‐operator reproducibility of the procedure. A procedure to univocally identify the anatomical landmarks was created, exploiting the in vitro accessibility of the specimen's surface. Through the analysis on 53 CT scans (106 hemipelvises), the alignment of the hemipelvis based on the alignment of a whole pelvis was analyzed: differences between male/female and right/left hemipelvises were not statistically significant To overcome the uncertainty in the identification of the acetabular rim, a standard acetabular plane was defined. An alignment procedure was developed to implement such anatomical reference frame. The intra‐operator repeatability and the inter‐operator reproducibility were quantified with four operators, on male and female hemipelvises. The intra‐operator repeatability was better than 1.5°. The inter‐operator reproducibility was better than 2.0°. Alignment in the transverse plane was the most repeatable. The presented procedure to align hemipelvic specimens is sufficiently robust, standardized, and accessible. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1645–1652, 2018.