Junjie Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Junjie Wang has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Wei Wang
5 shared publicationsYihai Bao
Independent Consultant Engineer, Gaithersburg, MD 20878
5 shared publicationsDawn Lehman
Civil & Environmental Engineering, University of Washington, Seattle, WA, USA
3 shared publications- Wei Wang
Tongji University
3 shared publications Hetao Hou
2 shared publicationsRuofan Lu
2 shared publications
Latest Publications
- 25 September 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 132
Study on the axial compressive performance of foamed ceramic composite walls reinforced with high ductile concrete
- 25 September 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 132
Study on the axial compressive performance of foamed ceramic composite walls reinforced with high ductile concrete
- 5 March 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 123
In-plane cyclic tests of composite walls with precast faceplates and concrete-filled steel tube boundary elements
- 5 March 2026
- Published by Elsevier in Journal of Building Engineering
- Vol. 123
In-plane cyclic tests of composite walls with precast faceplates and concrete-filled steel tube boundary elements
- 1 February 2022
- Published by Elsevier in Thin-Walled Structures
- Vol. 171
Block shear performance of double-line bolted S690 steel angles under uniaxial tension
- 1 February 2022
- Published by Elsevier in Thin-Walled Structures
- Vol. 171
Block shear performance of double-line bolted S690 steel angles under uniaxial tension
- 1 May 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 146 (5)
Full-Scale Test of a Steel–Concrete Composite Floor System with Moment-Resisting Connections under a Middle-Edge Column Removal Scenario
To investigate the load-resisting mechanisms and responses of typical steel–concrete composite frames under the progressive collapse scenario, a bay full-scale steel–concrete composite floor system was quasi-statically tested till failure under a middle-edge column removal scenario. The test specimen was extracted from a prototype building, which was designed according to modern design codes. Based on the measured load-deflection response, load-carrying mechanisms, deformation patterns, and failure modes were discussed in detail. The maximum capacity was achieved at a chord rotation angle of 0.163 rad, where the steel girder and the composite slab contributed 19.2% and 80.8% of the total resistance, respectively. The peak resistant load, as a result of the combined catenary and tensile membrane action, is 15.9% higher than that of the flexural action alone. The load-carrying capacity of the test specimen is 5.5 times larger than the ASCE load combination for extraordinary events. The continuous steel deck and moment-resisting beam–column connections have a significant influence on the load-carrying capacity and the deformation capacity of the composite floor system.- 1 May 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 146 (5)
Full-Scale Test of a Steel–Concrete Composite Floor System with Moment-Resisting Connections under a Middle-Edge Column Removal Scenario
To investigate the load-resisting mechanisms and responses of typical steel–concrete composite frames under the progressive collapse scenario, a bay full-scale steel–concrete composite floor system was quasi-statically tested till failure under a middle-edge column removal scenario. The test specimen was extracted from a prototype building, which was designed according to modern design codes. Based on the measured load-deflection response, load-carrying mechanisms, deformation patterns, and failure modes were discussed in detail. The maximum capacity was achieved at a chord rotation angle of 0.163 rad, where the steel girder and the composite slab contributed 19.2% and 80.8% of the total resistance, respectively. The peak resistant load, as a result of the combined catenary and tensile membrane action, is 15.9% higher than that of the flexural action alone. The load-carrying capacity of the test specimen is 5.5 times larger than the ASCE load combination for extraordinary events. The continuous steel deck and moment-resisting beam–column connections have a significant influence on the load-carrying capacity and the deformation capacity of the composite floor system.- 2 March 2020
- Published by Taylor & Francis in Structure and Infrastructure Engineering
- Vol. 17 (2) , 202-216
Numerical investigation on progressive collapse resistance of steel-concrete composite floor systems
Steel-concrete composite floor systems are commonly used in steel buildings. Stability under gravity and lateral loading depends on these systems. To better understand the design parameters that govern the progressive collapse behaviour of steel-concrete composite floor systems, high-resolution finite-element analyses (FEA) is conducted. Steel fracture and concrete damage are explicitly considered in the finite-element model (FEM). The model is validated using full-scale test data including comparison of the measured response and failure modes. The validated model is used to conduct a parametric study to investigate untested parameters including (i) concrete strength, (ii) horizontal constraint, (iii) steel deck thickness, (iv) reinforcement ratio in the composite slab, and (v) the number of the shear studs. The simulation results are used to determine the optimum design to increase progressive collapse resistance. Specifically, it is found that increasing the continuity and the horizontal constraint of the steel deck, the steel deck thickness, and number of shear studs increase this resistance. Considering the steel consumption and the common practice in the construction, improving the continuity and the horizontal constraint of the steel deck are the best choices to improve the collapse resistance.
- 2 March 2020
- Published by Taylor & Francis in Structure and Infrastructure Engineering
- Vol. 17 (2) , 202-216
Numerical investigation on progressive collapse resistance of steel-concrete composite floor systems
Steel-concrete composite floor systems are commonly used in steel buildings. Stability under gravity and lateral loading depends on these systems. To better understand the design parameters that govern the progressive collapse behaviour of steel-concrete composite floor systems, high-resolution finite-element analyses (FEA) is conducted. Steel fracture and concrete damage are explicitly considered in the finite-element model (FEM). The model is validated using full-scale test data including comparison of the measured response and failure modes. The validated model is used to conduct a parametric study to investigate untested parameters including (i) concrete strength, (ii) horizontal constraint, (iii) steel deck thickness, (iv) reinforcement ratio in the composite slab, and (v) the number of the shear studs. The simulation results are used to determine the optimum design to increase progressive collapse resistance. Specifically, it is found that increasing the continuity and the horizontal constraint of the steel deck, the steel deck thickness, and number of shear studs increase this resistance. Considering the steel consumption and the common practice in the construction, improving the continuity and the horizontal constraint of the steel deck are the best choices to improve the collapse resistance.
- 1 December 2019
- Published by Elsevier in Engineering Structures
- Vol. 200
Progressive collapse simulation of the steel-concrete composite floor system considering ductile fracture of steel
- 1 December 2019
- Published by Elsevier in Engineering Structures
- Vol. 200
Progressive collapse simulation of the steel-concrete composite floor system considering ductile fracture of steel
- 1 February 2019
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 153, 55-70
Effects of different steel-concrete composite slabs on rigid steel beam-column connection under a column removal scenario
- 1 February 2019
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 153, 55-70
Effects of different steel-concrete composite slabs on rigid steel beam-column connection under a column removal scenario
- 17 April 2018
- Published by American Society of Civil Engineers (ASCE)
- p. 236-245
Enhanced Bolted Connection Detailing of H-Beam-to-RHS Column Joints for Disproportionate Collapse Prevention
A partial damage caused by an abnormal load could trigger progressive collapse of high rise buildings which may lead to fatal consequences. To meliorate structural robustness, one types of joint with improved connection details—modified bolted connection and their corresponding design methods are proposed on the basis of the conventional RHS column joint with through diaphragm. The experimental results indicate that the modified bolted connection can enhance the vertical deformation capacity of the beam-column assemblages before the force transmission failure at the bottom of connection region, which is conductive to the development of catenary action by axial force in the beams. For that reason, the beam-column assemblages can provide greater vertical carrying capacity and the improved connection details can be used in designing and transforming structures against disproportionate collapse.
- 17 April 2018
- Published by American Society of Civil Engineers (ASCE)
- p. 236-245
Enhanced Bolted Connection Detailing of H-Beam-to-RHS Column Joints for Disproportionate Collapse Prevention
A partial damage caused by an abnormal load could trigger progressive collapse of high rise buildings which may lead to fatal consequences. To meliorate structural robustness, one types of joint with improved connection details—modified bolted connection and their corresponding design methods are proposed on the basis of the conventional RHS column joint with through diaphragm. The experimental results indicate that the modified bolted connection can enhance the vertical deformation capacity of the beam-column assemblages before the force transmission failure at the bottom of connection region, which is conductive to the development of catenary action by axial force in the beams. For that reason, the beam-column assemblages can provide greater vertical carrying capacity and the improved connection details can be used in designing and transforming structures against disproportionate collapse.
- 1 February 2017
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 129, 141-155
Slab effect of composite subassemblies under a column removal scenario
- 1 February 2017
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 129, 141-155
Slab effect of composite subassemblies under a column removal scenario