Vitalii Nuianzin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vitalii Nuianzin has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Artem Maiboroda
National University of Civil Protection of Ukraine
4 shared publications - Dmytro Tregubov
National University of Civil Protection of Ukraine
2 shared publications - Olena Danyk
National University of Civil Protection of Ukraine
2 shared publications - Tetiana Kostenko
National University of Civil Protection of Ukraine
2 shared publications - Yuliana Hapon
Kharkiv National Automobile and Highway University
2 shared publications - Yuliana Hapon
National University of Civil Defence of Ukraine
2 shared publications
Latest Publications
- 6 November 2025
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1165, 83-89
Investigation of Fire Extinguishing Properties of Multicomponent Systems with Combined Action Based on Wetted Lightweight Bulk Materials for Extinguishing Polar Flammable Liquids
To extinguish flammable polar liquids, it is proposed to use a multicomponent fire extinguishing system consisting of one or two layers of wetted lightweight bulk materials. It has been established that wetting bulk materials leads to a significant increase in the following components of fire extinguishing action: cooling, insulation, and dilution. In addition, the introduction of water into the fire extinguishing system leads to a decrease in the concentration of vapors of polar flammable liquids above the fire extinguishing layer of bulk materials due to their absorption by water. Crushed foam glass with a granule size of 10-15 mm was selected as a bulk material for the formation of the base layer of the fire extinguishing system. To improve the insulating properties of the base layer, it is proposed to apply swollen perlite with a granule size of 1.0-1.4 mm or swollen lamellar vermiculite with a scale size of 1 × 2.5 mm to its surface. Such sizes of perlite and vermiculite particles enable them to fill the cavities between the granules of the foam glass base layer, which leads to an increase in the insulating properties of the fire extinguishing system. The following were experimentally determined: bulk density, buoyancy in methanol, ethanol, propanol-2, and acetone, moisture retention of bulk materials, and the fraction of material that spilled through the foam glass layer. The fire extinguishing capacity of the proposed fire extinguishing systems based on bulk materials in the case of extinguishing polar flammable liquids was experimentally determined. The systems based on bulk materials have a combined fire extinguishing effect by the following mechanisms of combustion termination: cooling, insulation, and dilution. It is concluded that the advantages of the proposed system in comparison with existing fire extinguishing agents for polar flammable liquids are substantiated.
- 6 November 2025
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1165, 83-89
Investigation of Fire Extinguishing Properties of Multicomponent Systems with Combined Action Based on Wetted Lightweight Bulk Materials for Extinguishing Polar Flammable Liquids
To extinguish flammable polar liquids, it is proposed to use a multicomponent fire extinguishing system consisting of one or two layers of wetted lightweight bulk materials. It has been established that wetting bulk materials leads to a significant increase in the following components of fire extinguishing action: cooling, insulation, and dilution. In addition, the introduction of water into the fire extinguishing system leads to a decrease in the concentration of vapors of polar flammable liquids above the fire extinguishing layer of bulk materials due to their absorption by water. Crushed foam glass with a granule size of 10-15 mm was selected as a bulk material for the formation of the base layer of the fire extinguishing system. To improve the insulating properties of the base layer, it is proposed to apply swollen perlite with a granule size of 1.0-1.4 mm or swollen lamellar vermiculite with a scale size of 1 × 2.5 mm to its surface. Such sizes of perlite and vermiculite particles enable them to fill the cavities between the granules of the foam glass base layer, which leads to an increase in the insulating properties of the fire extinguishing system. The following were experimentally determined: bulk density, buoyancy in methanol, ethanol, propanol-2, and acetone, moisture retention of bulk materials, and the fraction of material that spilled through the foam glass layer. The fire extinguishing capacity of the proposed fire extinguishing systems based on bulk materials in the case of extinguishing polar flammable liquids was experimentally determined. The systems based on bulk materials have a combined fire extinguishing effect by the following mechanisms of combustion termination: cooling, insulation, and dilution. It is concluded that the advantages of the proposed system in comparison with existing fire extinguishing agents for polar flammable liquids are substantiated.
- 6 November 2025
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1165, 111-118
Research on Thermal Runaway of Mechanically Damaged Li-Ion Batteries and its Stopping by Excess Water
The construction, operating principles, and Li-ion battery thermal runaway mechanisms were analyzed. The external mechanical damage to a Li-ion battery with the uncontrolled thermal runaway development was investigated. The battery self-heating temperature regime was determined. A possible reactions set leading to intense materials self-heating and decomposition was considered. The battery self-heating stopping by immersing it in a container with a water excess relative to the stoichiometric amount for the lithium metal maximum mass that can accumulate was investigated. The change in resulting aqueous solution pH was measured, and the hydrogen release was also recorded. Reaction completion time dependences was established. The water required amount to absorb the heat that could be released during the reaction was calculated, which correlated with the experimental data. Possible measures to Li-ion batteries prevent and stop the burning were considered.
- 6 November 2025
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1165, 111-118
Research on Thermal Runaway of Mechanically Damaged Li-Ion Batteries and its Stopping by Excess Water
The construction, operating principles, and Li-ion battery thermal runaway mechanisms were analyzed. The external mechanical damage to a Li-ion battery with the uncontrolled thermal runaway development was investigated. The battery self-heating temperature regime was determined. A possible reactions set leading to intense materials self-heating and decomposition was considered. The battery self-heating stopping by immersing it in a container with a water excess relative to the stoichiometric amount for the lithium metal maximum mass that can accumulate was investigated. The change in resulting aqueous solution pH was measured, and the hydrogen release was also recorded. Reaction completion time dependences was established. The water required amount to absorb the heat that could be released during the reaction was calculated, which correlated with the experimental data. Possible measures to Li-ion batteries prevent and stop the burning were considered.
- 30 October 2025
- Published by National University of Civil Protection of Ukraine in Problems of Emergency Situations
- p. 160
Моделювання вибухонебезпечних властивостей амонійної селітри
Систематизовано уявлення стосовно механізмів виникнення вибухових властивостей амонійної селітри агропризначення. Показано, що сучасні уявлення лише частково описують випадковість таких подій без обґрунтування чітких механізмів розвитку. Систематизовано напрямки зміни властивостей селітри за різних добавок та умов зберігання, а також шляхи підвищення стійкості її будови під час зберігання. Порівняно механізми запобіганню виникненню вибухової здатності для типових агросумішей селітри з сульфатом амонію або карбонатом кальцію. Наведено схеми хімічних перетворень амонійної селітри під час розкладання за умов температурного впливу або інших шляхів ініціювання. Показано, що питомий тротиловий еквівалент вибуху амонійної селітри коливається у межах 0,45–1,35 залежно від набору супутніх факторів. Оцінено можливі наслідки вибуху для селітри агропризначення масою 3000 т на підставі усередненого тротилового еквіваленту вибуху. Оцінено можливі наслідки вибуху агросумішей селітри порушеного складу масою 10000 т за коефіцієнтом участі у вибуху. Проведено моделювання варіантів надмолекулярної будови амонійної селітри для стабільного стану та для моменту ініціювання вибухових перетворень з визначенням показника схильності до детонації КD на основі показника «легкості плавлення». Встановлено, що схема «лінійний кластер на основі нітробазису» дає високий показник схильності до детонації КD>1, що не відповідає дійсності; для тетрагональних ґраток отримано КD1, що визначає значні вибухові властивості. Можливість утворення різних надмолекулярних структур визначає можливість формування різних вибухових властивостей.
- 30 October 2025
- Published by National University of Civil Protection of Ukraine in Problems of Emergency Situations
- p. 160
Моделювання вибухонебезпечних властивостей амонійної селітри
Систематизовано уявлення стосовно механізмів виникнення вибухових властивостей амонійної селітри агропризначення. Показано, що сучасні уявлення лише частково описують випадковість таких подій без обґрунтування чітких механізмів розвитку. Систематизовано напрямки зміни властивостей селітри за різних добавок та умов зберігання, а також шляхи підвищення стійкості її будови під час зберігання. Порівняно механізми запобіганню виникненню вибухової здатності для типових агросумішей селітри з сульфатом амонію або карбонатом кальцію. Наведено схеми хімічних перетворень амонійної селітри під час розкладання за умов температурного впливу або інших шляхів ініціювання. Показано, що питомий тротиловий еквівалент вибуху амонійної селітри коливається у межах 0,45–1,35 залежно від набору супутніх факторів. Оцінено можливі наслідки вибуху для селітри агропризначення масою 3000 т на підставі усередненого тротилового еквіваленту вибуху. Оцінено можливі наслідки вибуху агросумішей селітри порушеного складу масою 10000 т за коефіцієнтом участі у вибуху. Проведено моделювання варіантів надмолекулярної будови амонійної селітри для стабільного стану та для моменту ініціювання вибухових перетворень з визначенням показника схильності до детонації КD на основі показника «легкості плавлення». Встановлено, що схема «лінійний кластер на основі нітробазису» дає високий показник схильності до детонації КD>1, що не відповідає дійсності; для тетрагональних ґраток отримано КD1, що визначає значні вибухові властивості. Можливість утворення різних надмолекулярних структур визначає можливість формування різних вибухових властивостей.
- 27 May 2025
- Published by National University of Civil Protection of Ukraine in Problems of Emergency Situations
- No. 41,p. 100-113
Fire extinguishing efficiency of lightweight bulk materials when extinguishing acetone
Experimental studies of the fire extinguishing ability of systems based on bulk porous materials during acetone extinguishing were carried out. For this purpose, the experimental methodology for determining the fire extinguishing properties of such extinguishing agents, which was previously proposed for ethanol, was chosen. Crushed foam glass, granulated swollen perlite, and vermiculite were selected as bulk materials. As the bottom layer, which ensures the buoyancy of the fire extinguishing system, granular foam glass with a granule size of 10-15 mm was used. As the upper layer, which provides high insulating properties, we consider swollen perlite with a size of spherical granules with a diameter of 1-1.5 mm and swollen lamellar vermiculite with a linear size of 1×2 mm. The buoyancy of the selected bulk materials in acetone, their bulk density and moisture retention were experimentally determined. On the basis of the experimental results, the heights of the layers of dry and wetted bulk materials required for acetone extinguishing were calculated. It was found that the wetting of bulk materials leads to a significant increase in their extinguishing properties. This fact is explained by two factors: an increase in the insulating properties of perlite and vermiculite due to filling the voids between the perlite and vermiculite granules and a decrease in the concentration of acetone vapour due to its absorption by water. The introduction of water also increases the cooling properties of the fire extinguishing system. The lowest heights of fire extinguishing layers during acetone extinguishing are provided by the systems: wetted foam glass – 6.5 cm and foam glass (5.5 cm)+perlite (1 cm)+water. An expert evaluation of the complex parameter of the effectiveness of fire extinguishing agents for the selected fire extinguishing systems when extinguishing acetone was carried out. The best result was shown by wetted foam glass Further directions of research on the fire extinguishing characteristics of systems based on bulk porous materials and methods for establishing a complex parameter of the effectiveness of fire extinguishing agents are outlined.
- 27 May 2025
- Published by National University of Civil Protection of Ukraine in Problems of Emergency Situations
- No. 41,p. 100-113
Fire extinguishing efficiency of lightweight bulk materials when extinguishing acetone
Experimental studies of the fire extinguishing ability of systems based on bulk porous materials during acetone extinguishing were carried out. For this purpose, the experimental methodology for determining the fire extinguishing properties of such extinguishing agents, which was previously proposed for ethanol, was chosen. Crushed foam glass, granulated swollen perlite, and vermiculite were selected as bulk materials. As the bottom layer, which ensures the buoyancy of the fire extinguishing system, granular foam glass with a granule size of 10-15 mm was used. As the upper layer, which provides high insulating properties, we consider swollen perlite with a size of spherical granules with a diameter of 1-1.5 mm and swollen lamellar vermiculite with a linear size of 1×2 mm. The buoyancy of the selected bulk materials in acetone, their bulk density and moisture retention were experimentally determined. On the basis of the experimental results, the heights of the layers of dry and wetted bulk materials required for acetone extinguishing were calculated. It was found that the wetting of bulk materials leads to a significant increase in their extinguishing properties. This fact is explained by two factors: an increase in the insulating properties of perlite and vermiculite due to filling the voids between the perlite and vermiculite granules and a decrease in the concentration of acetone vapour due to its absorption by water. The introduction of water also increases the cooling properties of the fire extinguishing system. The lowest heights of fire extinguishing layers during acetone extinguishing are provided by the systems: wetted foam glass – 6.5 cm and foam glass (5.5 cm)+perlite (1 cm)+water. An expert evaluation of the complex parameter of the effectiveness of fire extinguishing agents for the selected fire extinguishing systems when extinguishing acetone was carried out. The best result was shown by wetted foam glass Further directions of research on the fire extinguishing characteristics of systems based on bulk porous materials and methods for establishing a complex parameter of the effectiveness of fire extinguishing agents are outlined.
- Open Access
- 1 January 2025
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 9 (1) , 152-164
PREDICTION OF AMMONIA DANGERS TAKING INTO ACCOUNT THE SUPRAMOLECULAR STRUCTUR
The work aim is to analyze the ammonia hazards, ways to eliminate them, and to develop methods for hazards parameters predicting by the supramolecular structures modeling in comparison with hydrocarbons. The work task is to summarize information about ammonia hazards, analyze their origin, and extend assessing methods of the hydrocarbons supramolecular structure to the ammonia description. Thework analyzes the formation of physicochemical hazard indicators of ammonia and its aqueous solutions. A supramolecular structure influence theoretical assessment on the hazards genesis was carried out. Attention is focused on the developments lack for the such implementation an approach for ammonia. A standard techniques review for eliminating the dangers of ammonia and its aqueous solutions during storage or use in technological processes, as well as in the emergency leakage case, was carried out. Using the hydrocarbons example, the stepwiseness and decrease of maximum permissible concentrations (MPC) in homologous series, which is preserved for the ammonia–hydrazine pair, is shown. The close nature of the change in MPC, solubility in water, and the n-alcohols content in the azeotropic mixture with water was observed. The melting temperature, stoichiometric conditions of combustion, flammability limits, solubility in water were described in cluster structure parameters with a good correlation. To predict the ammonia properties, various schemes of the supramolecular structure worked: for the melting state, different combustion conditions, solubility in а water. The melting temperature is described by the clustering coefficient K = 14; the combustion stoichiometric condition –as an ammonia tetramer with 3 peroxide bridges; lower FL –as ammonia hydroperoxide with β = 1; the upper FL –as an ammonia dimer with 1 peroxide bridge with β = 0.5, an aqueous solution according by a scheme close to stoichiometric combustion conditions, as a tetramer and 14 associated water molecules.Key words:ammonia, hydrocarbons, hazards parameters, maximum permissible concentration, supramolecular structure, cluster, length.
- 1 January 2025
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 9 (1) , 152-164
Open AccessPREDICTION OF AMMONIA DANGERS TAKING INTO ACCOUNT THE SUPRAMOLECULAR STRUCTUR
The work aim is to analyze the ammonia hazards, ways to eliminate them, and to develop methods for hazards parameters predicting by the supramolecular structures modeling in comparison with hydrocarbons. The work task is to summarize information about ammonia hazards, analyze their origin, and extend assessing methods of the hydrocarbons supramolecular structure to the ammonia description. Thework analyzes the formation of physicochemical hazard indicators of ammonia and its aqueous solutions. A supramolecular structure influence theoretical assessment on the hazards genesis was carried out. Attention is focused on the developments lack for the such implementation an approach for ammonia. A standard techniques review for eliminating the dangers of ammonia and its aqueous solutions during storage or use in technological processes, as well as in the emergency leakage case, was carried out. Using the hydrocarbons example, the stepwiseness and decrease of maximum permissible concentrations (MPC) in homologous series, which is preserved for the ammonia–hydrazine pair, is shown. The close nature of the change in MPC, solubility in water, and the n-alcohols content in the azeotropic mixture with water was observed. The melting temperature, stoichiometric conditions of combustion, flammability limits, solubility in water were described in cluster structure parameters with a good correlation. To predict the ammonia properties, various schemes of the supramolecular structure worked: for the melting state, different combustion conditions, solubility in а water. The melting temperature is described by the clustering coefficient K = 14; the combustion stoichiometric condition –as an ammonia tetramer with 3 peroxide bridges; lower FL –as ammonia hydroperoxide with β = 1; the upper FL –as an ammonia dimer with 1 peroxide bridge with β = 0.5, an aqueous solution according by a scheme close to stoichiometric combustion conditions, as a tetramer and 14 associated water molecules.Key words:ammonia, hydrocarbons, hazards parameters, maximum permissible concentration, supramolecular structure, cluster, length.
- 1 January 2024
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 8 (2)
DETERMINATION OF THE HEAT OF FORMATION OF ALKYL GLYCID ETHERS FOR THE ASSESSMENT OF THEIR FIRE HAZARD
Epoxy compounds, i.e. compounds that contain a three-membered ring of two hydrogen atoms and one oxygen atom, were synthesized in the middle of the last century and were initially used only as starting products for epoxy resins [1]. But over time, the scope of their application has expanded significantly. In particular, glycidol and its derivatives, in which the hydroxyl hydrogen atom is replaced by alkyl groups, attracted the attention of the chemical industry. The history of production and use of glycidol ethers (epoxy-containing ethers) dates back only a few dozen years. But today they are widely used in industry, in particular as solvents, semi-products for the synthesis of other chemical products and, in particularly large quantities, as active thinners and modifiers of epoxy resins and other polymer materials [2-4]. Theoretical and laboratory studies of the properties of these compounds do not keep up with the development of the scale of their manufacture and application. Meanwhile, most of them belong to combustible substances, and the lower representatives (methylglycidol and ethyl, propyl and n-butyl derivatives) may also be flammable. This necessitates a detailed study of their thermodynamic properties, most of which are based on the heat of compound formation. In this work, this indicator was determined for the four most typical representatives through the experimental determination of their heat of combustion and subsequent recalculation according to Hess's law.Key words:Heat of formation, heat of combustion, glycidol ethers.
- 1 January 2024
- Published by National University of Civil Protection of Ukraine in Emergency Situations: Prevention and Liquidation
- Vol. 8 (2)
DETERMINATION OF THE HEAT OF FORMATION OF ALKYL GLYCID ETHERS FOR THE ASSESSMENT OF THEIR FIRE HAZARD
Epoxy compounds, i.e. compounds that contain a three-membered ring of two hydrogen atoms and one oxygen atom, were synthesized in the middle of the last century and were initially used only as starting products for epoxy resins [1]. But over time, the scope of their application has expanded significantly. In particular, glycidol and its derivatives, in which the hydroxyl hydrogen atom is replaced by alkyl groups, attracted the attention of the chemical industry. The history of production and use of glycidol ethers (epoxy-containing ethers) dates back only a few dozen years. But today they are widely used in industry, in particular as solvents, semi-products for the synthesis of other chemical products and, in particularly large quantities, as active thinners and modifiers of epoxy resins and other polymer materials [2-4]. Theoretical and laboratory studies of the properties of these compounds do not keep up with the development of the scale of their manufacture and application. Meanwhile, most of them belong to combustible substances, and the lower representatives (methylglycidol and ethyl, propyl and n-butyl derivatives) may also be flammable. This necessitates a detailed study of their thermodynamic properties, most of which are based on the heat of compound formation. In this work, this indicator was determined for the four most typical representatives through the experimental determination of their heat of combustion and subsequent recalculation according to Hess's law.Key words:Heat of formation, heat of combustion, glycidol ethers.
- Open Access
- 26 June 2023
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 110,p. 264-276
The research of the fire resistance limits of a reinforced concrete slab according to the results of fire tests without mechanical load
The paper analyzes the thermal effect of fire on reinforced concrete slabs based on their heating according to the standard fire temperature regime in a small-sized installation for the study of the thermal effect of fire on building structures. On the basis of the proposed method, a methodology was created that makes it possible to obtain data on temperature distributions on the surfaces of a slab fragment and in its cross-section. The course and results of the conducted fire test are described, and the adequacy and reproducibility of the experimental data are verified. The temperature distribution over the entire area of the fire furnace, the studied fragments, was analyzed and the obtained results were processed. The possibility of creating a standard fire temperature regime in the fire furnace chamber has been verified. According to the results of this work, it was established that during the heating of reinforced concrete, the release of moisture and steam inside the material was observed: on the heated surface, this process took place from 15 to 25 minutes, on the unheated surface from 39 to 57 minutes, and at the level of the reinforcement from 31 to 55 minutes, the heating of the structure at all levels was uniform in the planes of placement of thermocouples, the maximum temperature at the level of the reinforcement was 200°C, it was observed in the last minute of the experiment and continued to increase linearly after leaving the plateau, the maximum temperature on the unheated surface of the rock was 110°C, it observed at the last minute of the experiment and continued to grow linearly after leaving the plateau. The adequacy of the experimental data was confirmed: the relative deviation did not exceed 4%, and the calculated adequacy criteria (Fisher, Student and Cochrane) were below the critical value.
- 26 June 2023
- Published by Kyiv National University of Construction and Architecture in Strength of Materials and Theory of Structures
- No. 110,p. 264-276
Open AccessThe research of the fire resistance limits of a reinforced concrete slab according to the results of fire tests without mechanical load
The paper analyzes the thermal effect of fire on reinforced concrete slabs based on their heating according to the standard fire temperature regime in a small-sized installation for the study of the thermal effect of fire on building structures. On the basis of the proposed method, a methodology was created that makes it possible to obtain data on temperature distributions on the surfaces of a slab fragment and in its cross-section. The course and results of the conducted fire test are described, and the adequacy and reproducibility of the experimental data are verified. The temperature distribution over the entire area of the fire furnace, the studied fragments, was analyzed and the obtained results were processed. The possibility of creating a standard fire temperature regime in the fire furnace chamber has been verified. According to the results of this work, it was established that during the heating of reinforced concrete, the release of moisture and steam inside the material was observed: on the heated surface, this process took place from 15 to 25 minutes, on the unheated surface from 39 to 57 minutes, and at the level of the reinforcement from 31 to 55 minutes, the heating of the structure at all levels was uniform in the planes of placement of thermocouples, the maximum temperature at the level of the reinforcement was 200°C, it was observed in the last minute of the experiment and continued to increase linearly after leaving the plateau, the maximum temperature on the unheated surface of the rock was 110°C, it observed at the last minute of the experiment and continued to grow linearly after leaving the plateau. The adequacy of the experimental data was confirmed: the relative deviation did not exceed 4%, and the calculated adequacy criteria (Fisher, Student and Cochrane) were below the critical value.
- Open Access
- 1 January 2023
- Published by Sumy State University in Journal of Engineering Sciences
- Vol. 10 (2) , D1-D7
A Method of Evaluating the Destruction of a Reinforced Concrete Hollow Core Slab for Ensuring Fire Resistance
Fire tests of reinforced concrete floor slabs do not allow the detection of the onset of the boundary state due to loss of entirety because blocks are installed on the unheated surface to reproduce the design load. This prevents the formation of cracks through which toxic combustion products, smoke, and temperature spread can penetrate. Determining a building structure’s actual fire resistance limit was fixed at the onset of any fire resistance boundary state. It was proven that calculation methods for fire resistance assessment have significant advantages over experimental methods. To reduce the number of finite elements for a rational calculation of the fire resistance assessment of a reinforced concrete hollow core slab, a geometric model of 1/4 of this structure was built. The possibility of visualizing the studied structure at full scale was realized when obtaining the calculation results. The stress-strain state of the studied structure was evaluated based on the thermal and mechanical loading results applied to the reinforced concrete hollow core slab. Thus, the work’s objective was achieved based on the calculation experiments’ results. A methodology was developed for calculating the destruction of a reinforced concrete hollow core slab while assessing its fire resistance. Scientific fundamentals for determining the onset of the boundary state of loss of entirety were developed. The proposed methodology allowed for a reliable assessment of the fire resistance of such structures.
- 1 January 2023
- Published by Sumy State University in Journal of Engineering Sciences
- Vol. 10 (2) , D1-D7
Open AccessA Method of Evaluating the Destruction of a Reinforced Concrete Hollow Core Slab for Ensuring Fire Resistance
Fire tests of reinforced concrete floor slabs do not allow the detection of the onset of the boundary state due to loss of entirety because blocks are installed on the unheated surface to reproduce the design load. This prevents the formation of cracks through which toxic combustion products, smoke, and temperature spread can penetrate. Determining a building structure’s actual fire resistance limit was fixed at the onset of any fire resistance boundary state. It was proven that calculation methods for fire resistance assessment have significant advantages over experimental methods. To reduce the number of finite elements for a rational calculation of the fire resistance assessment of a reinforced concrete hollow core slab, a geometric model of 1/4 of this structure was built. The possibility of visualizing the studied structure at full scale was realized when obtaining the calculation results. The stress-strain state of the studied structure was evaluated based on the thermal and mechanical loading results applied to the reinforced concrete hollow core slab. Thus, the work’s objective was achieved based on the calculation experiments’ results. A methodology was developed for calculating the destruction of a reinforced concrete hollow core slab while assessing its fire resistance. Scientific fundamentals for determining the onset of the boundary state of loss of entirety were developed. The proposed methodology allowed for a reliable assessment of the fire resistance of such structures.
- Open Access
- 25 February 2020
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 1 (1 (103)) , 32-39
Revealing patterns of the effective mechanical characteristics of cellular sheet polycarbonate for explosion venting panels
Revealing patterns of the effective mechanical characteristics of cellular sheet polycarbonate for explosion venting panels
- 25 February 2020
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 1 (1 (103)) , 32-39
Open AccessRevealing patterns of the effective mechanical characteristics of cellular sheet polycarbonate for explosion venting panels
Revealing patterns of the effective mechanical characteristics of cellular sheet polycarbonate for explosion venting panels
- Open Access
- 26 January 2018
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 1 (10 (91)) , 31-37
Development of the technique for restricting the propagation of fire in natural peat ecosystems
Development of the technique for restricting the propagation of fire in natural peat ecosystems
- 26 January 2018
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 1 (10 (91)) , 31-37
Open AccessDevelopment of the technique for restricting the propagation of fire in natural peat ecosystems
Development of the technique for restricting the propagation of fire in natural peat ecosystems