Muhammad Ahsan Shafique
Research Interests
Muhammad Ahsan Shafique has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Ghulam Murtaza
Department of Physics Islamia College Peshawar Khyber Pakhtunkhwa Pakistan
2 shared publications - Ahmed S. Haidyrah
Nuclear and Radiological Control Unit, King Abdulaziz City for Science and Technology (KACST), Riyadh 11442, Saudi Arabia
1 shared publication - Athar N. Akhtar
Centre for Advanced Studies in Physics, GC University, Lahore 54000, Pakistan
1 shared publication Athar Naeem Akhtar
Government College University, Lahore
1 shared publicationG. Murtaza
Government College University, Lahore
1 shared publicationGhulam Farid
Department of Applied Physics University of Barcelona C/Martí i Franquès 1 08028 Barcelona Catalunya Spain
1 shared publication
Latest Publications
- 19 June 2025
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 54 (8) , 6749-6758
Tuning the Bandgap and Dielectric Properties of CdSnO3 Through Ag Doping: Implications for Opto-electronic and Dielectric Applications
- 19 June 2025
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 54 (8) , 6749-6758
Tuning the Bandgap and Dielectric Properties of CdSnO3 Through Ag Doping: Implications for Opto-electronic and Dielectric Applications
- Open Access
- 31 December 2022
- Published by International Research Alliance for Sustainable Development in Journal of Materials and Physical Sciences
- Vol. 3 (2) , 48-58
Ion Implantation in the Form of Layers: A Novel Method to Surface Properties
In this study, a novel method was adopted to tailor the surface properties of iron. We attempted to increase the degradation rate of iron by H-induced damaging. Equal number of H ions were implanted in four samples using a 2MV Pelletron accelerator. But the ion distribution was varied in the iron matrix by adding H ion layers in successively increasing depths. Interesting outcomes, contrary to our assumption were observed. The open-circuit potential was observed to shift toward a stable side. The Tefal plot also revealed improved corrosion potential and decreased corrosion current by adding H layers. Crystallographic studies revealed improved crystallinity and a small shift in preferred orientation of crystal growth.
- 31 December 2022
- Published by International Research Alliance for Sustainable Development in Journal of Materials and Physical Sciences
- Vol. 3 (2) , 48-58
Open AccessIon Implantation in the Form of Layers: A Novel Method to Surface Properties
In this study, a novel method was adopted to tailor the surface properties of iron. We attempted to increase the degradation rate of iron by H-induced damaging. Equal number of H ions were implanted in four samples using a 2MV Pelletron accelerator. But the ion distribution was varied in the iron matrix by adding H ion layers in successively increasing depths. Interesting outcomes, contrary to our assumption were observed. The open-circuit potential was observed to shift toward a stable side. The Tefal plot also revealed improved corrosion potential and decreased corrosion current by adding H layers. Crystallographic studies revealed improved crystallinity and a small shift in preferred orientation of crystal growth.
- Open Access
Effect of Cu Ions Implantation on Structural, Electronic, Optical and Dielectric Properties of Polymethyl Methacrylate (PMMA)
In this work, the effect of ion bombardment on the optical properties of Polymethylmethacrylate (PMMA) was studied. Polymer samples were implanted with 500 keV Cu+ ions with a fluence ranging from 1 × 1012 to 1 × 1014 ions/cm2. X-ray Diffractometer (XRD) study indicated a relatively lower variation with a higher dose of ions. Fourier Transform Infrared (FTIR) spectra exhibited that with the implantation of Cu ions the intensity of existing bands decreases, while the result confirms the existence of a C=C group. The pristine and ion-implanted samples were also investigated using photoluminescence (PL) and Ultra Violet-Visible (UV-VIS) spectra. The optical band gap (Eg) was observed up to 3.05 eV for the implanted samples, while the pristine sample exhibited a wide energy-gap up to ~3.9 eV. The change in the optical gap indicated the presence of a gradual phase transition for the polymer blends. The dielectric measurements of the pristine and Cu-implanted PMMA were investigated in the 10 Hz to 2 GHz frequency range. It was found that the implanted samples showed a significant decrease in the value of the dielectric constant. The value of the dielectric constant and dielectric loss of the PMMA and Cu-implanted samples at a 1-kHz frequency were found to be ~300 and 29, respectively. The modification of the PMMA energy bandgap in the current research suggested the potential use of Cu implanted PMMA in the field of optical communications and flexible electronic devices.
Open AccessEffect of Cu Ions Implantation on Structural, Electronic, Optical and Dielectric Properties of Polymethyl Methacrylate (PMMA)
In this work, the effect of ion bombardment on the optical properties of Polymethylmethacrylate (PMMA) was studied. Polymer samples were implanted with 500 keV Cu+ ions with a fluence ranging from 1 × 1012 to 1 × 1014 ions/cm2. X-ray Diffractometer (XRD) study indicated a relatively lower variation with a higher dose of ions. Fourier Transform Infrared (FTIR) spectra exhibited that with the implantation of Cu ions the intensity of existing bands decreases, while the result confirms the existence of a C=C group. The pristine and ion-implanted samples were also investigated using photoluminescence (PL) and Ultra Violet-Visible (UV-VIS) spectra. The optical band gap (Eg) was observed up to 3.05 eV for the implanted samples, while the pristine sample exhibited a wide energy-gap up to ~3.9 eV. The change in the optical gap indicated the presence of a gradual phase transition for the polymer blends. The dielectric measurements of the pristine and Cu-implanted PMMA were investigated in the 10 Hz to 2 GHz frequency range. It was found that the implanted samples showed a significant decrease in the value of the dielectric constant. The value of the dielectric constant and dielectric loss of the PMMA and Cu-implanted samples at a 1-kHz frequency were found to be ~300 and 29, respectively. The modification of the PMMA energy bandgap in the current research suggested the potential use of Cu implanted PMMA in the field of optical communications and flexible electronic devices.
- 25 June 2018
- Published by IOP Publishing in Materials Research Express
- Vol. 5 (7) , 076507
Study the effects of nitrogen ion implantation on structural and mechanical properties of AA7075
Nitrogen ions were implanted on the Aluminum Alloy 7075-T6 to study the structural and mechanical properties. The implantation was carried out at energy 1 MeV with ion doses ranging from 8×1014, 1.2×1015 and 5.2×1015 ions/cm2. Structural analysis of all the samples was done by X-ray Diffractometer (XRD) for the implanted ions. Surface morphology of all the samples was studied by Scanning Electron Microscopy (SEM). Changes in the surface and structure are directly related to the dose of ion implantation. To understand the mechanical properties Universal Tensile Testing Machine was applied. Modifications in the crystalline structure of the material exhibit new properties to the lattice site. Effects on the crystallite size and stress generated by the damage strongly vary the yield stress, ultimate tensile strength and percentage elongation of the material. Hardness was tested by the Vickers Micro Hardness Tester. The result shows that the surface hardness obtained at room temperature by implanting nitrogen ions initially decreases and then systematically increases due to subsequent damage. Graph representing yield stress, ultimate tensile strength and hardness are strongly agreed with each other. The micro structure indicates the fractured surface after Tensile Test.
- 25 June 2018
- Published by IOP Publishing in Materials Research Express
- Vol. 5 (7) , 076507
Study the effects of nitrogen ion implantation on structural and mechanical properties of AA7075
Nitrogen ions were implanted on the Aluminum Alloy 7075-T6 to study the structural and mechanical properties. The implantation was carried out at energy 1 MeV with ion doses ranging from 8×1014, 1.2×1015 and 5.2×1015 ions/cm2. Structural analysis of all the samples was done by X-ray Diffractometer (XRD) for the implanted ions. Surface morphology of all the samples was studied by Scanning Electron Microscopy (SEM). Changes in the surface and structure are directly related to the dose of ion implantation. To understand the mechanical properties Universal Tensile Testing Machine was applied. Modifications in the crystalline structure of the material exhibit new properties to the lattice site. Effects on the crystallite size and stress generated by the damage strongly vary the yield stress, ultimate tensile strength and percentage elongation of the material. Hardness was tested by the Vickers Micro Hardness Tester. The result shows that the surface hardness obtained at room temperature by implanting nitrogen ions initially decreases and then systematically increases due to subsequent damage. Graph representing yield stress, ultimate tensile strength and hardness are strongly agreed with each other. The micro structure indicates the fractured surface after Tensile Test.
- 22 February 2018
- Published by IOP Publishing in Materials Research Express
- Vol. 5 (3) , 036509
Study of wettability and cell viability of H implanted stainless steel
In the present work, the effect of hydrogen ion implantation on surface wettability and biocompatibility of stainless steel is investigated. Hydrogen ions are implanted in the near-surface of stainless steel to facilitate hydrogen bonding at different doses with constant energy of 500KeV, which consequently improve the surface wettability. Treated and untreated sample are characterized for surface wettability, incubation of hydroxyapatite and cell viability. Contact angle (CA) study reveals that surface wettability increases with increasing H- ion dose. Raman spectroscopy shows that precipitation of hydroxyapatite over the surface increase with increasing dose of H-ions. Cell viability study using MTT assay describes improved cell viability in treated samples as compared to the untreated sample. It is found that low dose of H-ions is more effective for cell proliferation and the cell count decreases with increasing ion dose. Our study demonstrates that H ion implantation improves the surface wettability and biocompatibility of stainless steel.
- 22 February 2018
- Published by IOP Publishing in Materials Research Express
- Vol. 5 (3) , 036509
Study of wettability and cell viability of H implanted stainless steel
In the present work, the effect of hydrogen ion implantation on surface wettability and biocompatibility of stainless steel is investigated. Hydrogen ions are implanted in the near-surface of stainless steel to facilitate hydrogen bonding at different doses with constant energy of 500KeV, which consequently improve the surface wettability. Treated and untreated sample are characterized for surface wettability, incubation of hydroxyapatite and cell viability. Contact angle (CA) study reveals that surface wettability increases with increasing H- ion dose. Raman spectroscopy shows that precipitation of hydroxyapatite over the surface increase with increasing dose of H-ions. Cell viability study using MTT assay describes improved cell viability in treated samples as compared to the untreated sample. It is found that low dose of H-ions is more effective for cell proliferation and the cell count decreases with increasing ion dose. Our study demonstrates that H ion implantation improves the surface wettability and biocompatibility of stainless steel.
- 3 August 2017
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 172 (7-8) , 590-599
Improved cell viability and hydroxyapatite growth on nitrogen ion-implanted surfaces
Stainless steel 306 is implanted with various doses of nitrogen ions using a 2 MV pelletron accelerator for the improvement of its surface biomedical properties. Raman spectroscopy reveals incubation of hydroxyapatite (HA) on all the samples and it is found that the growth of incubated HA is greater in higher ion dose samples. SEM profiles depict uniform growth and greater spread of HA with higher ion implantation. Human oral fibroblast response is also found consistent with Raman spectroscopy and SEM results; the cell viability is found maximum in samples treated with the highest (more than 300%) dose. XRD profiles signified greater peak intensity of HA with ion implantation; a contact angle study revealed hydrophilic behavior of all the samples but the treated samples were found to be lesser hydrophilic compared to the control samples. Nitrogen implantation yields greater bioactivity, improved surface affinity for HA incubation and improved hardness of the surface.
- 3 August 2017
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 172 (7-8) , 590-599
Improved cell viability and hydroxyapatite growth on nitrogen ion-implanted surfaces
Stainless steel 306 is implanted with various doses of nitrogen ions using a 2 MV pelletron accelerator for the improvement of its surface biomedical properties. Raman spectroscopy reveals incubation of hydroxyapatite (HA) on all the samples and it is found that the growth of incubated HA is greater in higher ion dose samples. SEM profiles depict uniform growth and greater spread of HA with higher ion implantation. Human oral fibroblast response is also found consistent with Raman spectroscopy and SEM results; the cell viability is found maximum in samples treated with the highest (more than 300%) dose. XRD profiles signified greater peak intensity of HA with ion implantation; a contact angle study revealed hydrophilic behavior of all the samples but the treated samples were found to be lesser hydrophilic compared to the control samples. Nitrogen implantation yields greater bioactivity, improved surface affinity for HA incubation and improved hardness of the surface.