Yohan Kondo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yohan Kondo has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Osamu Sato
National Institute of Advanced Industrial Science and Technology
12 shared publications Sonko Osawa
10 shared publicationsMasaharu Komori
Department of Mechanical Engineering and Science, Kyoto University
9 shared publicationsFumi Takeoka
8 shared publications- Toshiyuki Takatsuji
National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8563, Japan
8 shared publications - Youichi Bitou
National Institute of Advanced Industrial Science and Technology, AIST Tsukuba Central 3, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563, Japan
7 shared publications
Latest Publications
- Open Access
- 25 May 2026
- Published by Elsevier in Precision Engineering
- Vol. 102, 942-954
Non-contact absolute measurement of curved surface profiles using a scanning deflectometric profiler
- 25 May 2026
- Published by Elsevier in Precision Engineering
- Vol. 102, 942-954
Open AccessNon-contact absolute measurement of curved surface profiles using a scanning deflectometric profiler
- 17 December 2024
- Published by IOP Publishing in Metrologia
- Vol. 62 (1) , 015006
Accurate density measurement of a small solid sample using a combination of hydrostatic weighing and pressure-of-flotation methods
A new high-precision density measurement method for small non-silicon samples was developed. Hydrostatic weighing (HW) and the pressure-of-flotation method (PFM) are high-precision techniques for determination solid sample densities. However, in HW, the uncertainty of the density measurement is quite large when the volume of the sample is much smaller than that of a 1 kg silicon sample owing to the uncertainty of the auxiliary weights during the measurement. Additionally, the PFM is not applicable for measuring the density of non-silicon materials. We developed a new method that combines HW and the PFM. We prepared a small 45 g Si3N4 sphere sample with a diameter of 30 mm. By employing two silicon discs with these masses that were nearly equivalent to the apparent masses of the sample, the same auxiliary weights were used for both the standards and the sample. The new method was validated by measuring the density of the 45 g Si3N4 sphere with a relative standard uncertainty of 4.6 × 10−6, which is significantly lower than that obtained by traditional HW methods. This approach demonstrates substantial improvements in the precision of small-sample density measurements, thus offering a robust alternative to conventional techniques.
- 17 December 2024
- Published by IOP Publishing in Metrologia
- Vol. 62 (1) , 015006
Accurate density measurement of a small solid sample using a combination of hydrostatic weighing and pressure-of-flotation methods
A new high-precision density measurement method for small non-silicon samples was developed. Hydrostatic weighing (HW) and the pressure-of-flotation method (PFM) are high-precision techniques for determination solid sample densities. However, in HW, the uncertainty of the density measurement is quite large when the volume of the sample is much smaller than that of a 1 kg silicon sample owing to the uncertainty of the auxiliary weights during the measurement. Additionally, the PFM is not applicable for measuring the density of non-silicon materials. We developed a new method that combines HW and the PFM. We prepared a small 45 g Si3N4 sphere sample with a diameter of 30 mm. By employing two silicon discs with these masses that were nearly equivalent to the apparent masses of the sample, the same auxiliary weights were used for both the standards and the sample. The new method was validated by measuring the density of the 45 g Si3N4 sphere with a relative standard uncertainty of 4.6 × 10−6, which is significantly lower than that obtained by traditional HW methods. This approach demonstrates substantial improvements in the precision of small-sample density measurements, thus offering a robust alternative to conventional techniques.
- 3 December 2024
- Published by Elsevier in Precision Engineering
- Vol. 92, 167-178
Two-point diameter calibration of a sphere by a micro-coordinate measuring machine using a silicon gauge block as a reference standard
- 3 December 2024
- Published by Elsevier in Precision Engineering
- Vol. 92, 167-178
Two-point diameter calibration of a sphere by a micro-coordinate measuring machine using a silicon gauge block as a reference standard
- Open Access
- 5 September 2022
- Published by Japan Society for Precision Engineering in Journal of the Japan Society for Precision Engineering
- Vol. 88 (9) , 673-677
Sphere Diameter Measurement Using Micro-Coordinate Measuring Machine
- 5 September 2022
- Published by Japan Society for Precision Engineering in Journal of the Japan Society for Precision Engineering
- Vol. 88 (9) , 673-677
Open AccessSphere Diameter Measurement Using Micro-Coordinate Measuring Machine
- 1 April 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (2) , 024005
Two-point diameter calibration of a sphere using a micro-coordinate measuring machine at NMIJ
The National Metrology Institute of Japan (NMIJ) has developed a highly accurate two-point diameter measurement method of a sphere using a micro-coordinate measuring machine (µ-CMM) with a low-force two-dimensional touch probe. The measured sphere is used as a reference to calibrate the probe of other µ-CMM in industry. Our strategy for measuring sphere’s diameter is that the probe radius of NMIJ’s µ-CMM is calibrated using a reference gauge block, and the NMIJ’s µ-CMM using the calibrated probe measures the mean two-point diameter of a sphere. To achieve the highly accurate calibration of the reference gauge block, we have adopted a double-sided interferometer (DSI) and an atomic force microscopy (AFM). The DSI measures the length of gauge block without wringing. The phase correction value of the gauge block is evaluated by measuring the surface roughness using the AFM. Using the DSI and AFM, the mechanical length of reference gauge block was obtained with the expanded uncertainty of 13 nm (k = 2). Then, the probe radius of NMIJ’s µ-CMM was also calibrated using the reference gauge block calibrated by the DSI and the AFM. The µ-CMM’s probe radius was obtained with the expanded uncertainty of 10 nm (k = 2). Finally, the µ-CMM measured the mean two-point diameter of a sphere with the expanded uncertainty 21 nm (k = 2) was demonstrated.
- 1 April 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (2) , 024005
Two-point diameter calibration of a sphere using a micro-coordinate measuring machine at NMIJ
The National Metrology Institute of Japan (NMIJ) has developed a highly accurate two-point diameter measurement method of a sphere using a micro-coordinate measuring machine (µ-CMM) with a low-force two-dimensional touch probe. The measured sphere is used as a reference to calibrate the probe of other µ-CMM in industry. Our strategy for measuring sphere’s diameter is that the probe radius of NMIJ’s µ-CMM is calibrated using a reference gauge block, and the NMIJ’s µ-CMM using the calibrated probe measures the mean two-point diameter of a sphere. To achieve the highly accurate calibration of the reference gauge block, we have adopted a double-sided interferometer (DSI) and an atomic force microscopy (AFM). The DSI measures the length of gauge block without wringing. The phase correction value of the gauge block is evaluated by measuring the surface roughness using the AFM. Using the DSI and AFM, the mechanical length of reference gauge block was obtained with the expanded uncertainty of 13 nm (k = 2). Then, the probe radius of NMIJ’s µ-CMM was also calibrated using the reference gauge block calibrated by the DSI and the AFM. The µ-CMM’s probe radius was obtained with the expanded uncertainty of 10 nm (k = 2). Finally, the µ-CMM measured the mean two-point diameter of a sphere with the expanded uncertainty 21 nm (k = 2) was demonstrated.
- 5 January 2022
- Published by Taylor & Francis
- p. 241-244
Newly developed UHV-FE-HR-TEM for particle surface studies
We developed a ultrahigh vacuum high-resolution electron microscope equipped with a field-emission gun (UHV-FE-HR TEM) to study nano-particle surfaces. The ultra-high vacuum (2 × 10-8 Pa) allow us to keep clean surfaces on nano-particles. The microscope is equipped with a specially designed electron biprism for electron holography to measure a particle thickness, a high speed TV camera with a time resolution of 1 ms for dynamic observation, and a miniaturized STM which gives the spectroscopic information of a particle having a definite structure determined by high-resolution electron microscopy.
- 5 January 2022
- Published by Taylor & Francis
- p. 241-244
Newly developed UHV-FE-HR-TEM for particle surface studies
We developed a ultrahigh vacuum high-resolution electron microscope equipped with a field-emission gun (UHV-FE-HR TEM) to study nano-particle surfaces. The ultra-high vacuum (2 × 10-8 Pa) allow us to keep clean surfaces on nano-particles. The microscope is equipped with a specially designed electron biprism for electron holography to measure a particle thickness, a high speed TV camera with a time resolution of 1 ms for dynamic observation, and a miniaturized STM which gives the spectroscopic information of a particle having a definite structure determined by high-resolution electron microscopy.
- Open Access
Traceable Reference Full Metrology Chain for Innovative Aspheric and Freeform Optical Surfaces Accurate at the Nanometer Level
The design of innovative reference aspheric and freeform optical elements was investigated with the aim of calibration and verification of ultra-high accurate measurement systems. The verification is dedicated to form error analysis of aspherical and freeform optical surfaces based on minimum zone fitting. Two thermo-invariant material measures were designed, manufactured using a magnetorheological finishing process and selected for the evaluation of a number of ultra-high-precision measurement machines. All collected data sets were analysed using the implemented robust reference minimum zone (Hybrid Trust Region) fitting algorithm to extract the values of form error. Agreement among the results of several partners was observed, which demonstrates the establishment of a traceable reference full metrology chain for aspherical and freeform optical surfaces with small amplitudes.
Open AccessTraceable Reference Full Metrology Chain for Innovative Aspheric and Freeform Optical Surfaces Accurate at the Nanometer Level
The design of innovative reference aspheric and freeform optical elements was investigated with the aim of calibration and verification of ultra-high accurate measurement systems. The verification is dedicated to form error analysis of aspherical and freeform optical surfaces based on minimum zone fitting. Two thermo-invariant material measures were designed, manufactured using a magnetorheological finishing process and selected for the evaluation of a number of ultra-high-precision measurement machines. All collected data sets were analysed using the implemented robust reference minimum zone (Hybrid Trust Region) fitting algorithm to extract the values of form error. Agreement among the results of several partners was observed, which demonstrates the establishment of a traceable reference full metrology chain for aspherical and freeform optical surfaces with small amplitudes.
- 9 November 2016
- Published by Optica Publishing Group in Applied Optics
- Vol. 55 (32) , 9282-9287
Scanning deflectometric profiler for measurement of transparent parallel plates
An angle-based deflectometric surface profiler has been improved for the measurement of transparent parallel plates. In the developed system, the unwanted beam reflected from the back surface of the transparent parallel plate is removed by ensuring that the beam is obliquely incident to the measurement surface; this is realized by using a modified pentamirror unit comprising two mirrors installed at a predetermined angle to one another. The surface profile measurement of a transparent parallel plate with a repeatability of less than was successfully achieved. A measurement accuracy of around 3 nm was reached by comparing the developed system with other scanning deflectometric profiler systems for the measurement of a silicon bar mirror with a length of 300 mm.- 9 November 2016
- Published by Optica Publishing Group in Applied Optics
- Vol. 55 (32) , 9282-9287
Scanning deflectometric profiler for measurement of transparent parallel plates
An angle-based deflectometric surface profiler has been improved for the measurement of transparent parallel plates. In the developed system, the unwanted beam reflected from the back surface of the transparent parallel plate is removed by ensuring that the beam is obliquely incident to the measurement surface; this is realized by using a modified pentamirror unit comprising two mirrors installed at a predetermined angle to one another. The surface profile measurement of a transparent parallel plate with a repeatability of less than was successfully achieved. A measurement accuracy of around 3 nm was reached by comparing the developed system with other scanning deflectometric profiler systems for the measurement of a silicon bar mirror with a length of 300 mm.