Anna Chiari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anna Chiari has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Stefano Bergero
7 shared publications- Anna Magrini
Department of Civil Engineering and Architecture, University of Pavia, 27100 Pavia, Italy
1 shared publication Enrico Nannei
University of Genoa, Genoa, Italy
1 shared publication- Lucia Cattani
Department of Public Health and Experimental and Forensic Medicine, University of Pavia, 27100 Pavia, Italy
1 shared publication Paolo Cavalletti
1 shared publication
Latest Publications
- Open Access
A Method and Metrics to Assess the Energy Efficiency of Smart Working
The paper discusses the energy efficiency of smart working (SW) as a solution to traditional work-approach issues, with a focus on evaluating benefits for both employers and employees. Remote working, while offering environmental advantages such as reduced commuting and office space use, poses challenges in assessing its true impact. The study presents results from a dynamic analysis on a real residential building, typical of an architectural style diffused in northern Italy, revealing a 15% average increase in energy consumption when all work tasks are performed from home. To address concerns about the environmental impact of SW, the research proposes a method and metrics for evaluation. Four novel indices (SWEET, SEE, SSEE, and 4E) are introduced, providing a structured approach to assess the energy efficiency of SW initiatives. The paper outlines a methodology for data gathering and metric application, aiming to acquire quantitative insights and mitigate disparities arising from a transfer of burdens to employees. This contribution not only signifies a ground-breaking methodology but also addresses an unresolved research question concerning the evaluation of the actual energy efficiency of smart working implementations for both employers and employees. The results underscore the importance of understanding the nuances of SW’s impact on household energy usage and its broader implications for sustainability goals.
Open AccessA Method and Metrics to Assess the Energy Efficiency of Smart Working
The paper discusses the energy efficiency of smart working (SW) as a solution to traditional work-approach issues, with a focus on evaluating benefits for both employers and employees. Remote working, while offering environmental advantages such as reduced commuting and office space use, poses challenges in assessing its true impact. The study presents results from a dynamic analysis on a real residential building, typical of an architectural style diffused in northern Italy, revealing a 15% average increase in energy consumption when all work tasks are performed from home. To address concerns about the environmental impact of SW, the research proposes a method and metrics for evaluation. Four novel indices (SWEET, SEE, SSEE, and 4E) are introduced, providing a structured approach to assess the energy efficiency of SW initiatives. The paper outlines a methodology for data gathering and metric application, aiming to acquire quantitative insights and mitigate disparities arising from a transfer of burdens to employees. This contribution not only signifies a ground-breaking methodology but also addresses an unresolved research question concerning the evaluation of the actual energy efficiency of smart working implementations for both employers and employees. The results underscore the importance of understanding the nuances of SW’s impact on household energy usage and its broader implications for sustainability goals.
- Open Access
- 1 December 2017
- Published by Elsevier in Energy Procedia
- Vol. 140, 127-140
Energy refurbishment in existing buildings: thermal bridge correction according to DM 26/06/2015 limit values
- 1 December 2017
- Published by Elsevier in Energy Procedia
- Vol. 140, 127-140
Open AccessEnergy refurbishment in existing buildings: thermal bridge correction according to DM 26/06/2015 limit values
- 1 January 2011
- Published by ASME International
- p. 869-878
Energy Saving in a Heat Pump Air-Conditioning System Using Liquid Desiccant and Membrane Contactors
It has been demonstrated in the literature that significant energy savings can be achieved in air-conditioning through the use of so-called hybrid systems, in which a chemical dehumidification system is combined with a vapour-compression heat pump. The advantage of such systems lies in the fact that the heat pump can operate at a higher evaporation temperature than that of a traditional system in which dehumidification is achieved through condensation, thereby achieving higher coefficients of performance. The hybrid system described in the present paper operates as follows: the air supplied to the conditioned ambient is simultaneously cooled and dehumidified in an air-solution membrane contactor. The LiCl solution is cooled by means of a vapour-compression heat pump using the refrigerant KLEA 410A. The solution is regenerated in another membrane contactor by exploiting the exhaust air and the heat rejected by the condenser. A study of the steady-state behaviour of the system in summer climatic conditions was carried out, on varying some significant operating parameters, such as the thermal efficiency of the heat exchangers, the outdoor temperature and the sensible load of the conditioned room. The performances of the hybrid system were compared with those of a traditional direct-expansion air-conditioning plant; the results of the simulations reveal that, in particular operating conditions, energy saving can exceed 50%.
- 1 January 2011
- Published by ASME International
- p. 869-878
Energy Saving in a Heat Pump Air-Conditioning System Using Liquid Desiccant and Membrane Contactors
It has been demonstrated in the literature that significant energy savings can be achieved in air-conditioning through the use of so-called hybrid systems, in which a chemical dehumidification system is combined with a vapour-compression heat pump. The advantage of such systems lies in the fact that the heat pump can operate at a higher evaporation temperature than that of a traditional system in which dehumidification is achieved through condensation, thereby achieving higher coefficients of performance. The hybrid system described in the present paper operates as follows: the air supplied to the conditioned ambient is simultaneously cooled and dehumidified in an air-solution membrane contactor. The LiCl solution is cooled by means of a vapour-compression heat pump using the refrigerant KLEA 410A. The solution is regenerated in another membrane contactor by exploiting the exhaust air and the heat rejected by the condenser. A study of the steady-state behaviour of the system in summer climatic conditions was carried out, on varying some significant operating parameters, such as the thermal efficiency of the heat exchangers, the outdoor temperature and the sensible load of the conditioned room. The performances of the hybrid system were compared with those of a traditional direct-expansion air-conditioning plant; the results of the simulations reveal that, in particular operating conditions, energy saving can exceed 50%.
- 1 November 2010
- Published by Elsevier in Energy and Buildings
- Vol. 42 (11) , 1976-1986
Performance analysis of a liquid desiccant and membrane contactor hybrid air-conditioning system
- 1 November 2010
- Published by Elsevier in Energy and Buildings
- Vol. 42 (11) , 1976-1986
Performance analysis of a liquid desiccant and membrane contactor hybrid air-conditioning system
- 1 January 2006
- Published by ASME International
- p. 155-163
Vapour Compression and Liquid Desiccant Hybrid System for Air Conditioning
The present study examines the performance of a hybrid air-conditioning system in which a vapour compression inverse cycle is integrated with an air dehumidification system working with hygroscopic solution and hydrophobic membrane. This approach may prove to be a valid alternative to the traditional summertime air-conditioning system, which involves cooling the air to below its dew point and subsequently reheating it. The system examined simultaneously cools and dehumidifies the air in an air-LiCl solution membrane vapour exchanger before it enters the conditioned environment. The LiCl solution is cooled by means of a vapour compression inverse cycle that uses the refrigerant KLEA 407C. The heat rejected by the condenser is used to regenerate the solution. A SIMULINK calculation programme was used to simulate the system in steady-state conditions. The performance of the system was analysed on varying significant operating parameters and was compared with that of a traditional direct-expansion air-conditioning plant. The results of the simulations revealed significant power saving which, in certain operating conditions, was as much as 50%.
- 1 January 2006
- Published by ASME International
- p. 155-163
Vapour Compression and Liquid Desiccant Hybrid System for Air Conditioning
The present study examines the performance of a hybrid air-conditioning system in which a vapour compression inverse cycle is integrated with an air dehumidification system working with hygroscopic solution and hydrophobic membrane. This approach may prove to be a valid alternative to the traditional summertime air-conditioning system, which involves cooling the air to below its dew point and subsequently reheating it. The system examined simultaneously cools and dehumidifies the air in an air-LiCl solution membrane vapour exchanger before it enters the conditioned environment. The LiCl solution is cooled by means of a vapour compression inverse cycle that uses the refrigerant KLEA 407C. The heat rejected by the condenser is used to regenerate the solution. A SIMULINK calculation programme was used to simulate the system in steady-state conditions. The performance of the system was analysed on varying significant operating parameters and was compared with that of a traditional direct-expansion air-conditioning plant. The results of the simulations revealed significant power saving which, in certain operating conditions, was as much as 50%.
- 1 August 2001
- Published by Elsevier in Applied Thermal Engineering
- Vol. 21 (11) , 1119-1135
Experimental and theoretical analysis of air humidification/dehumidification processes using hydrophobic capillary contactors
- 1 August 2001
- Published by Elsevier in Applied Thermal Engineering
- Vol. 21 (11) , 1119-1135
Experimental and theoretical analysis of air humidification/dehumidification processes using hydrophobic capillary contactors
- 1 October 2000
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 21 (4) , 187-195
Air humidification with membrane contactors: experimental and theoretical results
This paper describes an experimental and theoretical investigation of a non-traditional approach to the air humidification process that uses a hydrophobic membrane contactor acting as a porous barrier between the water and the air to be humidified. The cross-flow contactor consists of a 1.2 m2 total membrane surface of hollow polypropylene capillaries, 200 μm wall thickness, arranged in a staggered array. A set of experimental results obtained with air flow-rates up to 80 m3/h outside the bundle of capillaries is presented and discussed in relation to the theoretical predictions given by a numerical model developed to predict the humidification efficiency of the contactor. Results show a good humidification efficiency of this system. The influence of the various parameters that affect vapour mass flux through the contactor is pointed out.
- 1 October 2000
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 21 (4) , 187-195
Air humidification with membrane contactors: experimental and theoretical results
This paper describes an experimental and theoretical investigation of a non-traditional approach to the air humidification process that uses a hydrophobic membrane contactor acting as a porous barrier between the water and the air to be humidified. The cross-flow contactor consists of a 1.2 m2 total membrane surface of hollow polypropylene capillaries, 200 μm wall thickness, arranged in a staggered array. A set of experimental results obtained with air flow-rates up to 80 m3/h outside the bundle of capillaries is presented and discussed in relation to the theoretical predictions given by a numerical model developed to predict the humidification efficiency of the contactor. Results show a good humidification efficiency of this system. The influence of the various parameters that affect vapour mass flux through the contactor is pointed out.