Zbigniew Ogonowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zbigniew Ogonowski has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Szymon Ogonowski
Department of Measurements and Control Systems, Silesian University of Technology, Akademicka 16, 44-100 Gliwice, Poland
6 shared publications - Marek Pawelczyk
Silesian University of Technology, Department of Measurements and Control Systems, Akademicka 16, 44-100 Gliwice, Poland
4 shared publications Markus Swierzy
2 shared publications- Dariusz Bismor
Silesian University of Technology
1 shared publication - Dariusz Foszcz
Faculty of Civil Engineering and Resource Management, AGH University of Krakow, al. A. Mickiewicza 30, 30-059 Krakow, Poland
1 shared publication Klaus Damert
1 shared publication
Latest Publications
- Open Access
Comparison of Wet and Dry Grinding in Electromagnetic Mill
Comparison of dry and wet grinding process in an electromagnetic mill is presented in this paper. The research was conducted in a batch copper ore grinding. Batch mode allows for precise parametrization and constant repetitive conditions of the experiments. The following key aspects were tested: processing time, feed size, size of the grinding media, mass of the material and graining media, and density of the pulp. The particles size distribution of the product samples was analyzed in the laboratory after each experiment. The paper discusses the experimental results as well as the concept of dry and wet grinding and classification circuits for the electromagnetic mill. The main points of the discussion are the size reduction effectiveness and power consumption of the entire system.
Open AccessComparison of Wet and Dry Grinding in Electromagnetic Mill
Comparison of dry and wet grinding process in an electromagnetic mill is presented in this paper. The research was conducted in a batch copper ore grinding. Batch mode allows for precise parametrization and constant repetitive conditions of the experiments. The following key aspects were tested: processing time, feed size, size of the grinding media, mass of the material and graining media, and density of the pulp. The particles size distribution of the product samples was analyzed in the laboratory after each experiment. The paper discusses the experimental results as well as the concept of dry and wet grinding and classification circuits for the electromagnetic mill. The main points of the discussion are the size reduction effectiveness and power consumption of the entire system.
- Open Access
- 27 March 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (4) , 506
Multi-Objective and Multi-Rate Control of the Grinding and Classification Circuit with Electromagnetic Mill
The paper presents an innovative construction and installation of dry grinding in electromagnetic mill that provides a significant reduction of energy consumption when compared to traditional mills. The installation constitutes complex multi-objective plant. To gain control over all the objectives, hierarchical structure of control system was developed where different time-horizons involve multi-rate scheme of steering. The paper presents solutions for the direct regulation, supervisory control, and optimization level. The electromagnetic mill installation constitutes a unique setup that causes open loop instability and implies the application of novel control schemes at all of the levels. The paper presents these solutions and illustrates them with the results of experiments carried out on the electromagnetic mill installations.
- 27 March 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (4) , 506
Open AccessMulti-Objective and Multi-Rate Control of the Grinding and Classification Circuit with Electromagnetic Mill
The paper presents an innovative construction and installation of dry grinding in electromagnetic mill that provides a significant reduction of energy consumption when compared to traditional mills. The installation constitutes complex multi-objective plant. To gain control over all the objectives, hierarchical structure of control system was developed where different time-horizons involve multi-rate scheme of steering. The paper presents solutions for the direct regulation, supervisory control, and optimization level. The electromagnetic mill installation constitutes a unique setup that causes open loop instability and implies the application of novel control schemes at all of the levels. The paper presents these solutions and illustrates them with the results of experiments carried out on the electromagnetic mill installations.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 170-173
Estimation problems of pneumatic transport system for electromagnetic grinding
The paper presents models and estimation algorithm of the air stream velocities in pneumatic material transport for supervisory and direct control layers of electromagnetic milling system. The algorithm uses redundant measurement system and identifies parameters of the first principle model to increase reliability of the measurements and to give rise of the fault detection system.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 170-173
Estimation problems of pneumatic transport system for electromagnetic grinding
The paper presents models and estimation algorithm of the air stream velocities in pneumatic material transport for supervisory and direct control layers of electromagnetic milling system. The algorithm uses redundant measurement system and identifies parameters of the first principle model to increase reliability of the measurements and to give rise of the fault detection system.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 69-76
Control System of Electromagnetic Mill Load
The paper presents control system of a working chamber load of an electromagnetic mill. The mill works in a dry grinding and classification circuit with pneumatic transport. Structure of the circuit is presented in the paper as well as the measurement system. Data acquisition uses direct and indirect measurements. The most challenging are the indirect measurement of the chamber fulfillment and the grinding media load which require special methodology. The proposed approach is explained and exemplary data are presented in the paper. Structure of the control system is described together with the implementation at a semi-industrial plant.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 69-76
Control System of Electromagnetic Mill Load
The paper presents control system of a working chamber load of an electromagnetic mill. The mill works in a dry grinding and classification circuit with pneumatic transport. Structure of the circuit is presented in the paper as well as the measurement system. Data acquisition uses direct and indirect measurements. The most challenging are the indirect measurement of the chamber fulfillment and the grinding media load which require special methodology. The proposed approach is explained and exemplary data are presented in the paper. Structure of the control system is described together with the implementation at a semi-industrial plant.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 8, 370-375
Power optimizing control of grinding process in electromagnetic mill
The paper presents optimizing control of the electromagnetic grinding system. The electromagnetic grinding is a complex process, thus formulation of the optimization problem is done in a top-down manner. To do so, the parameters which influence product quality and serves as decision variables are specially selected. The selection follows from environmental analysis of the system and discussion of the dynamics of disturbances which affect the grinding process. The criterion function to be minimized is electrical energy consumption. Algorithms solving optimization problem are described in the paper. The optimizing control performs as adaptive-like system where minimum energy is kept by proper control of the inverter. Control system constitutes an element of SCADA layered structure.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 8, 370-375
Power optimizing control of grinding process in electromagnetic mill
The paper presents optimizing control of the electromagnetic grinding system. The electromagnetic grinding is a complex process, thus formulation of the optimization problem is done in a top-down manner. To do so, the parameters which influence product quality and serves as decision variables are specially selected. The selection follows from environmental analysis of the system and discussion of the dynamics of disturbances which affect the grinding process. The criterion function to be minimized is electrical energy consumption. Algorithms solving optimization problem are described in the paper. The optimizing control performs as adaptive-like system where minimum energy is kept by proper control of the inverter. Control system constitutes an element of SCADA layered structure.
- 26 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 901-906
Model of the air stream ratio for an electromagnetic mill control system
The paper presents a model of the air stream ratio in the dry grinding and classification circuit with the electromagnetic mill. The concept of the grinding system is described along with indirect measurement methodology. Model structure and identification problems are discussed and a supervisory control algorithm based on the model is derived.
- 26 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 901-906
Model of the air stream ratio for an electromagnetic mill control system
The paper presents a model of the air stream ratio in the dry grinding and classification circuit with the electromagnetic mill. The concept of the grinding system is described along with indirect measurement methodology. Model structure and identification problems are discussed and a supervisory control algorithm based on the model is derived.
- 1 January 2016
- Published by International Institute of Acoustics and Vibration (IIAV) in The International Journal of Acoustics and Vibration
- Vol. 21 (1)
Review and Comparison of Variable Step-Size LMS Algorithms
- 1 January 2016
- Published by International Institute of Acoustics and Vibration (IIAV) in The International Journal of Acoustics and Vibration
- Vol. 21 (1)
Review and Comparison of Variable Step-Size LMS Algorithms
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 195-199
Active suspension with a limited authority adaptive control
The paper presents feedback control algorithm for active vehicle suspension systems. The algorithm uses internal model of the system which is composed with two parts: disturbances path and control path. The first is highly non-stationary while the second is constituted with relatively fixed-parameters. This difference justifies the use of limited authority adaptive control, where only disturbance path is subjected to identifycation. The controller is derived in a direct adaptive form where the parameters of the controller are identified directly. Pole placement methodology is also involved to provide a room for upper-layer optimization which allows for inclusion additional requirements, for example optimal contact between wheels and road surface.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 195-199
Active suspension with a limited authority adaptive control
The paper presents feedback control algorithm for active vehicle suspension systems. The algorithm uses internal model of the system which is composed with two parts: disturbances path and control path. The first is highly non-stationary while the second is constituted with relatively fixed-parameters. This difference justifies the use of limited authority adaptive control, where only disturbance path is subjected to identifycation. The controller is derived in a direct adaptive form where the parameters of the controller are identified directly. Pole placement methodology is also involved to provide a room for upper-layer optimization which allows for inclusion additional requirements, for example optimal contact between wheels and road surface.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 433-438
Optimized control of air-conditioning process with recycle
The paper presents hierarchical control system of air-conditioning process with recycle. Technological demands require changes of the operating points which are realized by the upper control layer. Operating points are optimized using grey box model of the process: one part of the model is formulated as first principle model while the second is identified as the mathematical model. Dedicated optimization algorithm is derived and described in the paper. Direct (lower) control layer uses gain-scheduled PID controllers. This hierarchical control system has been tested on a pilot air-conditioning process which is aimed to verify real-world installation of air-conditioning for the hall where creep testing of metals is performed.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 433-438
Optimized control of air-conditioning process with recycle
The paper presents hierarchical control system of air-conditioning process with recycle. Technological demands require changes of the operating points which are realized by the upper control layer. Operating points are optimized using grey box model of the process: one part of the model is formulated as first principle model while the second is identified as the mathematical model. Dedicated optimization algorithm is derived and described in the paper. Direct (lower) control layer uses gain-scheduled PID controllers. This hierarchical control system has been tested on a pilot air-conditioning process which is aimed to verify real-world installation of air-conditioning for the hall where creep testing of metals is performed.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 23-28
Stratified model identification
Structure choice and identification of stratified models' parameters are presented in this paper. Stratification is suggested to base on the environmental structure of the plant. Algorithm of Generalized Back Propagation Through Time is applied as the identification method. Vertical hot water tank serves as the illustration of application to single dimensional case. Methods of generalization on three dimensional case are suggested.
- 1 August 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 23-28
Stratified model identification
Structure choice and identification of stratified models' parameters are presented in this paper. Stratification is suggested to base on the environmental structure of the plant. Algorithm of Generalized Back Propagation Through Time is applied as the identification method. Vertical hot water tank serves as the illustration of application to single dimensional case. Methods of generalization on three dimensional case are suggested.