Hongze Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hongze Gao has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Wei Gao
School of Instrumentation Science and Engineering, Harbin Institute of Technology, Harbin 150001, China
2 shared publications - Yongguang Wang
School of Instrumentation Science and Engineering, Harbin Institute of Technology, Harbin, China
2 shared publications - Yuxin Zhao
National University of Defense Technology
2 shared publications Fei Yu
Harbin Institute of Technology (China)
1 shared publication- Guochen Wang
Harbin Institute of Technology
1 shared publication - Haozhe Wang
Duke University
1 shared publication
Latest Publications
- 27 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12169, 617-2725
Uncertainty analysis of fiber optical current transformer on-site calibration
The on-site calibration of fiber optical current transformer is often influenced by the environmental factors, resulting in certain deviation of results. We proposed the sources of uncertainty in this paper, which mainly include: the uncertainty uA(ε) induced by the error of standard FOCT, the uncertainty uB(ε) induced by the field environment and improper operation method, and the uncertainty uC(ε) induced by the calibrator unit. In further, the uB(ε) is analyzed detailed. This component is mainly produced by temperature, vibration and inhomogeneous magnetic field. The experimental results show that the errors of temperature, vibration and inhomogeneous magnetic field are 0.020%, 0.051% and 0.049%, respectively. Finally, we can calculate the synthetic standard uncertainty and expanded uncertainty of the DC calibration (P=99%) are 4.8×10-4 and 1.4×10-3, respectively. And the synthetic standard uncertainty and expanded uncertainty of the AC calibration (P=99%) are 5.6×10-4 and 1.6×10-3 respectively. The results show that the scheme can satisfy the uncertainty requirements of the direct comparison method (0.5S level).
- 27 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12169, 617-2725
Uncertainty analysis of fiber optical current transformer on-site calibration
The on-site calibration of fiber optical current transformer is often influenced by the environmental factors, resulting in certain deviation of results. We proposed the sources of uncertainty in this paper, which mainly include: the uncertainty uA(ε) induced by the error of standard FOCT, the uncertainty uB(ε) induced by the field environment and improper operation method, and the uncertainty uC(ε) induced by the calibrator unit. In further, the uB(ε) is analyzed detailed. This component is mainly produced by temperature, vibration and inhomogeneous magnetic field. The experimental results show that the errors of temperature, vibration and inhomogeneous magnetic field are 0.020%, 0.051% and 0.049%, respectively. Finally, we can calculate the synthetic standard uncertainty and expanded uncertainty of the DC calibration (P=99%) are 4.8×10-4 and 1.4×10-3, respectively. And the synthetic standard uncertainty and expanded uncertainty of the AC calibration (P=99%) are 5.6×10-4 and 1.6×10-3 respectively. The results show that the scheme can satisfy the uncertainty requirements of the direct comparison method (0.5S level).
- 27 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12169, 553-2556
Analysis of non-uniform magnetic field error and optimization design for fiber optic ultra-high current transformer
A reflection fiber optic current transformer (FOCT) based on equal-ampere-turn method and range self-expanding approach is proposed to measure ultra-high current in this paper. A flexible sensing coil is utilized in FOCT to suit the needs of the measurement environment and to enable installation and removal. At the same time, two significant difficulties have been raised: one is the nonlinear difficulty introduced by the equal-ampere-turn approach and the range self-expanding method; the other is the non-uniform magnetic field errors generated when the flexible sensing coil is put on site, including conductor eccentricity and non-closed angle, which can amplify the nonlinear problem. Therefore, in order to eliminate the non-uniform magnetic field error, a closed structure of λ/4 waveplate and reflector is designed for the reflection structure, and the sensing coil skeleton is optimized. Experimental results show that the FOCT with closed structure and sensing coil skeleton has a good range self-expanding ability. The accuracy at rated current can also fulfill the requirement of 0.2S. Finally, the FOCT was subjected to a temperature cycle test in the range of -40°C to 70°C, with a ratio error of less than ±0.2%. So the method's validity and feasibility are confirmed.
- 27 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12169, 553-2556
Analysis of non-uniform magnetic field error and optimization design for fiber optic ultra-high current transformer
A reflection fiber optic current transformer (FOCT) based on equal-ampere-turn method and range self-expanding approach is proposed to measure ultra-high current in this paper. A flexible sensing coil is utilized in FOCT to suit the needs of the measurement environment and to enable installation and removal. At the same time, two significant difficulties have been raised: one is the nonlinear difficulty introduced by the equal-ampere-turn approach and the range self-expanding method; the other is the non-uniform magnetic field errors generated when the flexible sensing coil is put on site, including conductor eccentricity and non-closed angle, which can amplify the nonlinear problem. Therefore, in order to eliminate the non-uniform magnetic field error, a closed structure of λ/4 waveplate and reflector is designed for the reflection structure, and the sensing coil skeleton is optimized. Experimental results show that the FOCT with closed structure and sensing coil skeleton has a good range self-expanding ability. The accuracy at rated current can also fulfill the requirement of 0.2S. Finally, the FOCT was subjected to a temperature cycle test in the range of -40°C to 70°C, with a ratio error of less than ±0.2%. So the method's validity and feasibility are confirmed.
- Open Access
- 10 January 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (2) , eaax8784
Realization of 2D crystalline metal nitrides via selective atomic substitution
Two-dimensional (2D) transition metal nitrides (TMNs) are new members in the 2D materials family with a wide range of applications. Particularly, highly crystalline and large area thin films of TMNs are desirable for applications in electronic and optoelectronic devices; however, the synthesis of these TMNs has not yet been achieved. Here, we report the synthesis of few-nanometer thin Mo5N6 crystals with large area and high quality via in situ chemical conversion of layered MoS2 crystals. The versatility of this general approach is demonstrated by expanding the method to synthesize W5N6 and TiN. Our strategy offers a new direction for preparing 2D TMNs with desirable characteristics, opening a door for studying fundamental physics and facilitating the development of next-generation electronics.
- 10 January 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (2) , eaax8784
Open AccessRealization of 2D crystalline metal nitrides via selective atomic substitution
Two-dimensional (2D) transition metal nitrides (TMNs) are new members in the 2D materials family with a wide range of applications. Particularly, highly crystalline and large area thin films of TMNs are desirable for applications in electronic and optoelectronic devices; however, the synthesis of these TMNs has not yet been achieved. Here, we report the synthesis of few-nanometer thin Mo5N6 crystals with large area and high quality via in situ chemical conversion of layered MoS2 crystals. The versatility of this general approach is demonstrated by expanding the method to synthesize W5N6 and TiN. Our strategy offers a new direction for preparing 2D TMNs with desirable characteristics, opening a door for studying fundamental physics and facilitating the development of next-generation electronics.