YWYongguang Wang

Yongguang Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yongguang Wang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Sensitivity-Enhanced Temperature Sensor of Cascaded Lyot Filter and Mach–Zehnder Interferometer Based on the Vernier Effect

    by Kaidi Tian, Zicheng Wang, Guochen Wang, Xingliang Wu, Yongguang Wang

    The compact structure and resistance to electromagnetic interference of optical fiber temperature sensors have garnered significant interest. Nevertheless, it is imperative to enhance the detecting sensitivity in order to adequately fulfill the existing requirements. This study proposes and demonstrates a sensitivity-enhanced optical fiber temperature sensor of cascaded Lyot filter and Mach-Zehnder interferometer (MZI) based on the Vernier effect. The MZI, which has two consecutive bubble-type upper tapers, is employed as a reference interferometer owing to the exceptional stability of its totally polarization-maintaining fiber (PMF) construction. A Lyot filter is created by fusion splicing a segment of PMF at a 45° angle between two linear polarizers, functioning as a sensing interferometer. The sensitivity of the cascaded sensor improves through the Vernier effect, which is produced when the length of the sensing PMF in the Lyot filter is modified to closely match the free spectral range (FSR) of the MZI. Experimental results reveal the Lyot filter’s sensitivity to be -1.4 nm/°C, while the cascaded sensor achieves an increased sensitivity of -28.3 nm/°C, with a sensitivity amplification factor of 20.2. The proposed sensor structure, composed of PMF, leverages the controllable polarization characteristics of PMF to enhance system performance, effectively addressing the issue of detection error that arises from the fluctuating polarization state of the optical signal being transmitted throughout the sensitivity test. This proposed optical fiber temperature sensor, with its robust polarization stability, simple fabrication, and high sensitivity, is suitable for high-precision industrial applications.


  • Ultrasensitive Optical Electric Field Sensor Based on Harmonic Vernier Effect

    by Guochen Wang, Yongguang Wang, Zicheng Wang, Wei Gao, Yuxin Zhao

    This paper proposed and demonstrated an ultrasensitive optical electric field sensor by hybrid cascaded configuration of a Fabry-Perot interferometer (FPI) and a fiber Sagnac interferometer (FSI). The FPI is fabricated by a LiNbO 3 crystal with length of 1.04 mm, while the FSI consists of a certain length of Panda polarization-maintain fiber. The sensitivity of the electric field can be significantly enhanced through the utilization of high-order harmonic Vernier effect by employing two interferometers. The experimental results show that the sensor is capable of measuring electric field 0 to 1.01 V/μm, with the sensitivity of 4.38 nm/E (40 times that of a single FPI). The results of many experiments demonstrate the sensor has excellent stability, with the electric field sensitivity stabilized at 4.38±0.0016 nm/E and a repeatability error of only 3.65×10 -4 . The sensor exhibits a low detection limit of merely 1.13×10 -2 E. Additionally, the temperature compensation of electric field sensors can be achieved by utilizing the sensitivity coefficient matrix. The proposed electric field sensor overcomes the inherent limitation of half-wave voltage for measuring electric field range, eliminating the need to incorporate a 1/4 wave plate into its structure. And it fundamentally eliminates disturbances caused by variations in light intensity on the sensor output. Applications using this sensor confirmed that it is expected to find widespread use in measurements of intense electric fields.


  • Uncertainty analysis of fiber optical current transformer on-site calibration

    by Wei Gao, Guochen Wang, Yongguang Wang, Yuxin Zhao, Hongze Gao

    The on-site calibration of fiber optical current transformer is often influenced by the environmental factors, resulting in certain deviation of results. We proposed the sources of uncertainty in this paper, which mainly include: the uncertainty uA(ε) induced by the error of standard FOCT, the uncertainty uB(ε) induced by the field environment and improper operation method, and the uncertainty uC(ε) induced by the calibrator unit. In further, the uB(ε) is analyzed detailed. This component is mainly produced by temperature, vibration and inhomogeneous magnetic field. The experimental results show that the errors of temperature, vibration and inhomogeneous magnetic field are 0.020%, 0.051% and 0.049%, respectively. Finally, we can calculate the synthetic standard uncertainty and expanded uncertainty of the DC calibration (P=99%) are 4.8×10-4 and 1.4×10-3, respectively. And the synthetic standard uncertainty and expanded uncertainty of the AC calibration (P=99%) are 5.6×10-4 and 1.6×10-3 respectively. The results show that the scheme can satisfy the uncertainty requirements of the direct comparison method (0.5S level).

  • Analysis of non-uniform magnetic field error and optimization design for fiber optic ultra-high current transformer

    by Fei Yu, Yuxin Zhao, Hongze Gao, Wei Gao, Yongguang Wang

    A reflection fiber optic current transformer (FOCT) based on equal-ampere-turn method and range self-expanding approach is proposed to measure ultra-high current in this paper. A flexible sensing coil is utilized in FOCT to suit the needs of the measurement environment and to enable installation and removal. At the same time, two significant difficulties have been raised: one is the nonlinear difficulty introduced by the equal-ampere-turn approach and the range self-expanding method; the other is the non-uniform magnetic field errors generated when the flexible sensing coil is put on site, including conductor eccentricity and non-closed angle, which can amplify the nonlinear problem. Therefore, in order to eliminate the non-uniform magnetic field error, a closed structure of λ/4 waveplate and reflector is designed for the reflection structure, and the sensing coil skeleton is optimized. Experimental results show that the FOCT with closed structure and sensing coil skeleton has a good range self-expanding ability. The accuracy at rated current can also fulfill the requirement of 0.2S. Finally, the FOCT was subjected to a temperature cycle test in the range of -40°C to 70°C, with a ratio error of less than ±0.2%. So the method's validity and feasibility are confirmed.