Ali Asheibi
Research Subjects
Ali Asheibi has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Ashraf Khalil
Universiti Teknologi Brunei,Electrical and Electronic Engineering Department,Bandar Seri Begawan,Brunei
7 shared publicationsZakariya Rajab
Electrical and Electronics Engineering Department, University of Benghazi, Benghazi, Libya
4 shared publications- Ashraf Khalil
DTU Engineering Technology, Technical University of Denmark, 2750 Ballerup, Denmark
3 shared publications Asma Alfergani
Electrical and Electronic Engineering Department, University of Benghazi, Benghazi, Libya
3 shared publications- David Stirling
School of Electrical, Computer and Telecommunications Engineering, University of Wollongong, Wollongong, Australia
3 shared publications Danny Sutanto
Sch. of Electr. Eng., Univ. of Wollongong, Wollongong, NSW
2 shared publications
Latest Publications
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A Case Study on Black Start Capability Assessment
Despite the fact that tremendous efforts have been placed to avoid outages on power system networks, forced outages can occur as a result of catastrophic event, device error, operator fault and cyber threats. These outages, when occur, can lead to partial or complete blackout. The effects of the blackout are national safety, financial losses, system reliability reduction, and threaten personnel. To minimise such impacts of the blackouts, it is essential to utilise the available black-start units to restore power system to normal condition with minimum restoration time. In this paper a black start modelling and simulation study is accomplished, using real data from Benghazi North Power Plant (BNPP), to validate the feasibility of a black start plan in terms of both steady state and transient operating conditions. It is found that selection of the optimum size of the black start depends on the capacity of the largest motor during starting, the capacitive charging reactance of the connected cable or transmission line as well as the size and vector group of the transformers.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A Case Study on Black Start Capability Assessment
Despite the fact that tremendous efforts have been placed to avoid outages on power system networks, forced outages can occur as a result of catastrophic event, device error, operator fault and cyber threats. These outages, when occur, can lead to partial or complete blackout. The effects of the blackout are national safety, financial losses, system reliability reduction, and threaten personnel. To minimise such impacts of the blackouts, it is essential to utilise the available black-start units to restore power system to normal condition with minimum restoration time. In this paper a black start modelling and simulation study is accomplished, using real data from Benghazi North Power Plant (BNPP), to validate the feasibility of a black start plan in terms of both steady state and transient operating conditions. It is found that selection of the optimum size of the black start depends on the capacity of the largest motor during starting, the capacitive charging reactance of the connected cable or transmission line as well as the size and vector group of the transformers.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Exact Method for Computing the Delay Margin for Power System Using Sweeping Test
The time delay is unavoidable in a power system and it degrades the performance of the system or even destabilizes the system. Determining the maximum delay margin is crucial for power system operators. In this paper, we introduce a precise method for delay margin computation. The method is based on converting the transcendental characteristic equation into a frequency dependent equation. The crossing frequencies are determined using the spectral radius which results in exact delay margin values. A single-machine infinite bus power system is selected as a simple case study. The validity of the proposed method has been proved through comparing with the most recent research work. The effects of the gain of the exciter, the mechanical power of the generator and the generator damping on the delay margin are studied. The delay margin decreases with increasing the gain of the exciter and the generator mechanical output. While the delay margin has negative trend for small values of the damping and positive trend for large damping values.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Exact Method for Computing the Delay Margin for Power System Using Sweeping Test
The time delay is unavoidable in a power system and it degrades the performance of the system or even destabilizes the system. Determining the maximum delay margin is crucial for power system operators. In this paper, we introduce a precise method for delay margin computation. The method is based on converting the transcendental characteristic equation into a frequency dependent equation. The crossing frequencies are determined using the spectral radius which results in exact delay margin values. A single-machine infinite bus power system is selected as a simple case study. The validity of the proposed method has been proved through comparing with the most recent research work. The effects of the gain of the exciter, the mechanical power of the generator and the generator damping on the delay margin are studied. The delay margin decreases with increasing the gain of the exciter and the generator mechanical output. While the delay margin has negative trend for small values of the damping and positive trend for large damping values.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Optimal Sizing of Stand-alone PV System Using Grey Wolf optimization
Photovoltaic systems are among the leading renewable energy sources. Their main drawback is their high initial cost. Optimizing the size of the system is one of the possible options to minimise the cost. Sizing of the system is the proper selection of the rating and the number of the system components such as the solar panel, the battery, the charger, and the DC/AC inverter. In recent years, the artificial intelligence algorithms have been deployed in optimizing the size of renewable energy systems. In this paper, we optimize the size of stand-alone photovoltaic system by applying grey wolf optimization algorithm. The inputs to the algorithm are the load data, the solar radiation and the ambient temperature. The stand-alone photovoltaic system is modelled and implemented in Matlab. The life cycle cost of the system is selected as our objective function in the grey wolf optimization algorithm. Using different PV system components with different specifications and prices, the results of the grey wolf optimization algorithm sizing are optimum as proven by simulations.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Optimal Sizing of Stand-alone PV System Using Grey Wolf optimization
Photovoltaic systems are among the leading renewable energy sources. Their main drawback is their high initial cost. Optimizing the size of the system is one of the possible options to minimise the cost. Sizing of the system is the proper selection of the rating and the number of the system components such as the solar panel, the battery, the charger, and the DC/AC inverter. In recent years, the artificial intelligence algorithms have been deployed in optimizing the size of renewable energy systems. In this paper, we optimize the size of stand-alone photovoltaic system by applying grey wolf optimization algorithm. The inputs to the algorithm are the load data, the solar radiation and the ambient temperature. The stand-alone photovoltaic system is modelled and implemented in Matlab. The life cycle cost of the system is selected as our objective function in the grey wolf optimization algorithm. Using different PV system components with different specifications and prices, the results of the grey wolf optimization algorithm sizing are optimum as proven by simulations.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Stability analysis of PV-based DC microgrid with communication delay
The emergence of the renewable energy sources such as the PV, fuel cells and storage batteries, in addition to the consumer electronic have shifted the view to DC Microgrids. In the DC Microgrid the energy sources, storage units and loads are connected to a DC Bus through DC/DC converters. In order to achieve the control tasks and for energy management, the sources should transfer their information through a kind of network. In this paper we present a networked system approach for PV based DC Microgrid. The DC Microgrid is modeled using Simulink/Matlab. The PV sources controllers communicate through wireless network to achieve current sharing. The required communication bandwidth is calculated. The controller achieves good performance even with the fluctuations in the PV sources.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Stability analysis of PV-based DC microgrid with communication delay
The emergence of the renewable energy sources such as the PV, fuel cells and storage batteries, in addition to the consumer electronic have shifted the view to DC Microgrids. In the DC Microgrid the energy sources, storage units and loads are connected to a DC Bus through DC/DC converters. In order to achieve the control tasks and for energy management, the sources should transfer their information through a kind of network. In this paper we present a networked system approach for PV based DC Microgrid. The DC Microgrid is modeled using Simulink/Matlab. The PV sources controllers communicate through wireless network to achieve current sharing. The required communication bandwidth is calculated. The controller achieves good performance even with the fluctuations in the PV sources.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Maximum allowable delay bound estimation using Lambert W function
The widespread of communication networks make them very promising to play a great role in future control systems. The communication networks will be present in the feedback control system which makes it a kind of time delay system. Closing the feedback system through a communication network introduces many challenges for the controller designers. Communication networks induce inherent time delay and some of the data may be lost which can destabilize the control system or result in poor system performance. It is important to identify the maximum time delay that the control system can withstand. In this paper, we report the application of the Lambert W function for calculating the maximum allowable delay bound in linear time delay control systems. The results of the calculation are compared with the most widely used Linear Matrix Inequalities based method.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Maximum allowable delay bound estimation using Lambert W function
The widespread of communication networks make them very promising to play a great role in future control systems. The communication networks will be present in the feedback control system which makes it a kind of time delay system. Closing the feedback system through a communication network introduces many challenges for the controller designers. Communication networks induce inherent time delay and some of the data may be lost which can destabilize the control system or result in poor system performance. It is important to identify the maximum time delay that the control system can withstand. In this paper, we report the application of the Lambert W function for calculating the maximum allowable delay bound in linear time delay control systems. The results of the calculation are compared with the most widely used Linear Matrix Inequalities based method.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Control of master-slave microgrid based on CAN bus
In this paper, the control of parallel voltage-source inverters Microgrid based on Controller Area Network (CAN) is introduced. The design is based on the maximum time delay that guarantees the stability where the system is composed of three-phase DC/AC inverters with master-slave control strategy in the rotational reference frame (dq frame). The reference current signals are sent from the master to the slave converters through Controller Area Network bus (CAN bus). A model for masterslave communication-based Microgrid is presented and the system is modeled as a general time delay system. The maximum time delay that guarantees the stability of the system is calculated using a Lyapunov-Krasovskii based linear matrix inequalities method. The results are tested through Matlab/Simulink and True-Time 2.0 simulation.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Control of master-slave microgrid based on CAN bus
In this paper, the control of parallel voltage-source inverters Microgrid based on Controller Area Network (CAN) is introduced. The design is based on the maximum time delay that guarantees the stability where the system is composed of three-phase DC/AC inverters with master-slave control strategy in the rotational reference frame (dq frame). The reference current signals are sent from the master to the slave converters through Controller Area Network bus (CAN bus). A model for masterslave communication-based Microgrid is presented and the system is modeled as a general time delay system. The maximum time delay that guarantees the stability of the system is calculated using a Lyapunov-Krasovskii based linear matrix inequalities method. The results are tested through Matlab/Simulink and True-Time 2.0 simulation.
- 1 April 2017
- Published by Allerton Press in Applied Solar Energy
- Vol. 53 (2) , 138-151
The benefits of the transition from fossil fuel to solar energy in Libya: A street lighting system case study
The Libyan economy is dominated by the oil and the gas industry which are considered as the primary energy sources for the generating power plants. With the increased energy demands in the near future, Libya will be forced to burn more oil and gas. This, in turn will result in reducing the country revenue, threatening the economy and increasing the CO2 emission. This triggers the alarm for Libya to an urgent plan to diversify the energy sources through using sustainable energy. The sun showers Libya every day by a huge amount of sunshine, especially during the peaks in the summer days. Recently, the country has been struggling to satisfy its escalating energy demands. The residential and street lighting loads constitute more than 50% of the electricity demands in Libya. Street lighting consumes more than 3.996 TW h, which is around one fifth of the energy demands in Libya. Energy conservation and transition from fossil fuel to renewable energy could have significant profit on the energy sector in Libya. For example, Libya is still relying on the old-fashioned, inefficient and unsustainable street lighting systems. Replacing the old technology lighting systems with up-to-date solar powered lighting system can achieve energy saving and sustainability. In this paper, improving the energy situation in Libya through replacing the high pressure sodium street lighting systems with solar powered LED street lighting systems is investigated. A four km road is chosen as a case study. Four alternatives are analyzed; grid-powered high pressure sodium lamp street lighting system, grid-powered LED lamp street lighting system, stand-alone solar powered LED street lighting system and grid-connected solar powered LED street lighting system. The four options are compared in terms of the capital cost, maintenance cost, total cost, fuel cost and the CO2 emission. Replacing the high pressure sodium lamp system with LED lamp system saves 75% of energy and reduces the CO2 emission by 75%. The stand-alone solar powered LED lighting system cuts the CO2 emission, saves the fuel and is economically feasible. Furthermore, improvement is attained if the solar powered lighting system is connected to the grid where the excess energy is fed to the grid. The two solar powered options are economically feasible and sustainable.
- 1 April 2017
- Published by Allerton Press in Applied Solar Energy
- Vol. 53 (2) , 138-151
The benefits of the transition from fossil fuel to solar energy in Libya: A street lighting system case study
The Libyan economy is dominated by the oil and the gas industry which are considered as the primary energy sources for the generating power plants. With the increased energy demands in the near future, Libya will be forced to burn more oil and gas. This, in turn will result in reducing the country revenue, threatening the economy and increasing the CO2 emission. This triggers the alarm for Libya to an urgent plan to diversify the energy sources through using sustainable energy. The sun showers Libya every day by a huge amount of sunshine, especially during the peaks in the summer days. Recently, the country has been struggling to satisfy its escalating energy demands. The residential and street lighting loads constitute more than 50% of the electricity demands in Libya. Street lighting consumes more than 3.996 TW h, which is around one fifth of the energy demands in Libya. Energy conservation and transition from fossil fuel to renewable energy could have significant profit on the energy sector in Libya. For example, Libya is still relying on the old-fashioned, inefficient and unsustainable street lighting systems. Replacing the old technology lighting systems with up-to-date solar powered lighting system can achieve energy saving and sustainability. In this paper, improving the energy situation in Libya through replacing the high pressure sodium street lighting systems with solar powered LED street lighting systems is investigated. A four km road is chosen as a case study. Four alternatives are analyzed; grid-powered high pressure sodium lamp street lighting system, grid-powered LED lamp street lighting system, stand-alone solar powered LED street lighting system and grid-connected solar powered LED street lighting system. The four options are compared in terms of the capital cost, maintenance cost, total cost, fuel cost and the CO2 emission. Replacing the high pressure sodium lamp system with LED lamp system saves 75% of energy and reduces the CO2 emission by 75%. The stand-alone solar powered LED lighting system cuts the CO2 emission, saves the fuel and is economically feasible. Furthermore, improvement is attained if the solar powered lighting system is connected to the grid where the excess energy is fed to the grid. The two solar powered options are economically feasible and sustainable.
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Economic feasibility of solar powered street lighting system in Libya
Libya is one of the countries blessed with high potential of renewable energy. Currently, the electricity in Libya is produced from fossil fuel to meet the demand on the local electricity market. In the near future, the demand on the energy will increase significantly. The growth in energy demand will lead to more oil and gas consumption in Libya. Additionally, the CO2 emissions will increase substantially. Therefore, Libya should make an urgent plan to use its alternative energy supplies to cover some of its load requirements. For example street lighting forms around 20% of the electricity consumption. The street lighting system in Libya is based on the high pressure sodium lamps which are powered from the electricity grid. The lamp rating ranges from 250 to 400 watts. As the country struggles to satisfy its electricity demands we propose replacing the conventional street lighting system with solar powered LED (Light emitting Diode) lighting system. The paper presents a case study for 4 km solar street lighting system in Almarj city. Two proposals are investigated, the conventional lighting system and the solar powered LED lighting system. A feasibility study of the street lighting system is carried out. The cost, energy savings and the CO2 emission of the two proposed systems are compared. The cost of the solar powered LED street lighting system is 1,250,200 LD, while the cost of the high pressure Sodium lamp street lighting system is 2,117,255 LD. Additionally, the solar powered LED street lighting system has no CO2 emissions.
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Economic feasibility of solar powered street lighting system in Libya
Libya is one of the countries blessed with high potential of renewable energy. Currently, the electricity in Libya is produced from fossil fuel to meet the demand on the local electricity market. In the near future, the demand on the energy will increase significantly. The growth in energy demand will lead to more oil and gas consumption in Libya. Additionally, the CO2 emissions will increase substantially. Therefore, Libya should make an urgent plan to use its alternative energy supplies to cover some of its load requirements. For example street lighting forms around 20% of the electricity consumption. The street lighting system in Libya is based on the high pressure sodium lamps which are powered from the electricity grid. The lamp rating ranges from 250 to 400 watts. As the country struggles to satisfy its electricity demands we propose replacing the conventional street lighting system with solar powered LED (Light emitting Diode) lighting system. The paper presents a case study for 4 km solar street lighting system in Almarj city. Two proposals are investigated, the conventional lighting system and the solar powered LED lighting system. A feasibility study of the street lighting system is carried out. The cost, energy savings and the CO2 emission of the two proposed systems are compared. The cost of the solar powered LED street lighting system is 1,250,200 LD, while the cost of the high pressure Sodium lamp street lighting system is 2,117,255 LD. Additionally, the solar powered LED street lighting system has no CO2 emissions.
- 24 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Networked control of parallel DC/DC converters over CAN bus
The rapid development and the low cost of the communication networks made them a viable alternative to conventional wiring in distributed energy systems. Closing the feedback through a communication network forms a networked control system which is characterized by time delay and packet loss. However, exchanging the control signals over communication networks reduces the complexity in the wiring and enhances the reliability, the induced time delay and data loss could lead to system instability. The most widely approach for modeling the time delay and the packet loss is through using Markov chains. The paper addresses the stability of parallel DC/DC Buck converters over CAN bus. The networked converters system is formulated as standard Markovian Jump System. The stochastic stability of the parallel DC/DC converters controlled through the CAN is investigated in the paper. The resulting stability problem is in the form of Linear Matrix Inequality. The range of the controller parameter that achieve the stochastic stability of the system over the CAN is calculated.
- 24 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Networked control of parallel DC/DC converters over CAN bus
The rapid development and the low cost of the communication networks made them a viable alternative to conventional wiring in distributed energy systems. Closing the feedback through a communication network forms a networked control system which is characterized by time delay and packet loss. However, exchanging the control signals over communication networks reduces the complexity in the wiring and enhances the reliability, the induced time delay and data loss could lead to system instability. The most widely approach for modeling the time delay and the packet loss is through using Markov chains. The paper addresses the stability of parallel DC/DC Buck converters over CAN bus. The networked converters system is formulated as standard Markovian Jump System. The stochastic stability of the parallel DC/DC converters controlled through the CAN is investigated in the paper. The resulting stability problem is in the form of Linear Matrix Inequality. The range of the controller parameter that achieve the stochastic stability of the system over the CAN is calculated.
- 24 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Stability of parallel DC/DC converters with time varying delay
The rapid development in communication networks made them very attractive to replace conventional wiring in distributed power electronic systems. Parallel DC/DC converters are one of the important distributed power electronic systems. Conventionally, the controllers exchange the control signals through wires. This reduces the reliability and increases the system cost and complexity. Replacing them with communication network will introduce a time delay that may lead to system instability. The paper addresses the stability of parallel DC converters controlled over communication networks. The network is represented as variable time delay. A theorem based on solving a set of linear matrix inequalities is used to investigate the delay-dependent stability of the system. The effects of the voltage controller parameters on the maximum allowable delay bound are investigated. Furthermore the effect of the time delay variation rate on the maximum allowable delay bound is discussed.
- 24 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Stability of parallel DC/DC converters with time varying delay
The rapid development in communication networks made them very attractive to replace conventional wiring in distributed power electronic systems. Parallel DC/DC converters are one of the important distributed power electronic systems. Conventionally, the controllers exchange the control signals through wires. This reduces the reliability and increases the system cost and complexity. Replacing them with communication network will introduce a time delay that may lead to system instability. The paper addresses the stability of parallel DC converters controlled over communication networks. The network is represented as variable time delay. A theorem based on solving a set of linear matrix inequalities is used to investigate the delay-dependent stability of the system. The effects of the voltage controller parameters on the maximum allowable delay bound are investigated. Furthermore the effect of the time delay variation rate on the maximum allowable delay bound is discussed.