Yaqi Shen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yaqi Shen has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Jing Ma
State Key Laboratory of New Energy Power System, North China Electric Power University, Changping District, Beijing 102206, China
9 shared publications - Letian Wang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
3 shared publications - Peng Cheng
China Institute of Energy and Transportation Integrated Development, North China Electric Power University, Beijing, China
3 shared publications - Phadke A.G
Virginia, United States
3 shared publications A. G. Phadke
Bradley Department of Electrical and Computer Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA
2 shared publications- Tong Wang
North China Electric Power University (Baoding)
2 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (6) , 4696-4715
Identification and Enhancement of Transient Voltage Oscillation Stability Involved With Switching Dynamic Process
Due to the nonlinear switching dynamics of inverterbased resources (IBRs), repeated low-voltage ride-through (LVRT) behavior has induced transient voltage oscillation phenomena, which have emerged in recent years, posing a substantial threat to the security and stability of modern power systems. To address this issue, this paper proposes a transient voltage instability identification method and coordinated control strategy for renewable energy systems. Firstly, a hybrid differentialalgebraic equation (DAE) system model incorporating sequential switching dynamics of IBRs is established. Subsequently, the dynamic response trajectories of the system corresponding to voltage instability phenomenon are accurately characterized through voltage bifurcation manifold theory, and a transient voltage instability identification method is proposed. Moreover, the impacts of dominant parameters on the switching process and transient voltage oscillation severity are analyzed. Finally, a multi-level coordinated control strategy is proposed based on the transient voltage instability criterion, and simulations conducted on real renewable energy station systems verify the effectiveness of the transient voltage instability identification method and the coordinated control strategy.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (6) , 4696-4715
Identification and Enhancement of Transient Voltage Oscillation Stability Involved With Switching Dynamic Process
Due to the nonlinear switching dynamics of inverterbased resources (IBRs), repeated low-voltage ride-through (LVRT) behavior has induced transient voltage oscillation phenomena, which have emerged in recent years, posing a substantial threat to the security and stability of modern power systems. To address this issue, this paper proposes a transient voltage instability identification method and coordinated control strategy for renewable energy systems. Firstly, a hybrid differentialalgebraic equation (DAE) system model incorporating sequential switching dynamics of IBRs is established. Subsequently, the dynamic response trajectories of the system corresponding to voltage instability phenomenon are accurately characterized through voltage bifurcation manifold theory, and a transient voltage instability identification method is proposed. Moreover, the impacts of dominant parameters on the switching process and transient voltage oscillation severity are analyzed. Finally, a multi-level coordinated control strategy is proposed based on the transient voltage instability criterion, and simulations conducted on real renewable energy station systems verify the effectiveness of the transient voltage instability identification method and the coordinated control strategy.
- Open Access
- 20 September 2023
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 17 (13) , 3325-3339
Stability analysis for sub‐synchronous oscillations in multi‐DFIGs connected system considering the interaction between generators
In order to reveal the multi‐DFIGs interaction mechanism in DFIG wind farms (DFIG‐WFs), this paper proposes a method based on dynamic energy flow path for stability analysis of sub‐synchronous oscillations in multi‐DFIGs connected system. First, the detailed dynamic energy model of DFIG‐WFs is established considering the inter‐DFIGs coupling effect, and the energy flow paths among multi‐DFIGs are revealed. From this, the interaction energy coefficient is defined to describe the effect of multi‐DFIGs interaction on the system stability, which can be divided into two items: the inter‐DFIGs induction coefficient and the inter‐DFIGs circulation coefficient. On this basis, how the differences in the parameters affect these coefficients are analysed. In this way, the effects of multi‐DFIGs interaction on the oscillation are clarified. Finally, a wind farm model is built in RT‐LAB for simulation verification. The results show that, the changes in DFIG parameters may have mutually exclusive effects on the two coefficients. When the parameters of DFIGs differ greatly, the circulation effect is dominant, which is mainly determined by the difference between DFIGs. If the parameters of DFIGs are similar to each other, the induction effect is dominant and the influence law of parameters is consistent with that of single equivalent model.
- 20 September 2023
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 17 (13) , 3325-3339
Open AccessStability analysis for sub‐synchronous oscillations in multi‐DFIGs connected system considering the interaction between generators
In order to reveal the multi‐DFIGs interaction mechanism in DFIG wind farms (DFIG‐WFs), this paper proposes a method based on dynamic energy flow path for stability analysis of sub‐synchronous oscillations in multi‐DFIGs connected system. First, the detailed dynamic energy model of DFIG‐WFs is established considering the inter‐DFIGs coupling effect, and the energy flow paths among multi‐DFIGs are revealed. From this, the interaction energy coefficient is defined to describe the effect of multi‐DFIGs interaction on the system stability, which can be divided into two items: the inter‐DFIGs induction coefficient and the inter‐DFIGs circulation coefficient. On this basis, how the differences in the parameters affect these coefficients are analysed. In this way, the effects of multi‐DFIGs interaction on the oscillation are clarified. Finally, a wind farm model is built in RT‐LAB for simulation verification. The results show that, the changes in DFIG parameters may have mutually exclusive effects on the two coefficients. When the parameters of DFIGs differ greatly, the circulation effect is dominant, which is mainly determined by the difference between DFIGs. If the parameters of DFIGs are similar to each other, the induction effect is dominant and the influence law of parameters is consistent with that of single equivalent model.
- Open Access
- 21 August 2023
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 154
A multi-time scale coordinated control and scheduling strategy of EVs considering guidance impacts in multi-areas with uncertain RESs
- 21 August 2023
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 154
Open AccessA multi-time scale coordinated control and scheduling strategy of EVs considering guidance impacts in multi-areas with uncertain RESs
- Open Access
- 3 February 2023
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 11
A low-carbon-oriented multi-time-scale dispatching strategy of multi-energy heterogeneous loads in clean heating scenarios of green residences
Clean energy utilization is important for the improvement of energy structure. At present, photothermal and electrothermal conversion technologies are becoming increasingly applied in many homes, which can thus be regarded as green residences. To meet the heating demand of green residences, solar hot water systems and electricity-to-heat (E2H) conversion devices, such as ground source heat pumps electric heating stoves and electric water heaters are widely installed to provide a clean form of heat. Besides, common loads, such as lighting, washing, and electric vehicles are daily loads in green residences. The above electric and thermal loads are regarded as multi-energy heterogeneous loads MEHLs can be used to decarbonize green residences by optimizing energy dispatch through flexible control. In this study, a novel energy structure of green residences was extended through the combination of SHWs, E2H, GSHPs, and EVs, as well as rooftop photovoltaic systems. Then, to minimize carbon emissions, a residential energy dispatching model was designed from day-ahead and real-time scales and a low-carbon-oriented multi-energy heterogeneous loads coordinated control strategy was proposed. Finally, to mitigate the residents’ loss of comfort caused by MEHL control, the indoor environment and water tank temperatures and the state of charge of EVs were regarded as special constraints. The simulation revealed that the proposed strategy can reduce carbon emissions by 33.07% and meet the basic demand for residential heat and electricity. Additionally, the strategy has good applicability for decarbonizing green residences.
- 3 February 2023
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 11
Open AccessA low-carbon-oriented multi-time-scale dispatching strategy of multi-energy heterogeneous loads in clean heating scenarios of green residences
Clean energy utilization is important for the improvement of energy structure. At present, photothermal and electrothermal conversion technologies are becoming increasingly applied in many homes, which can thus be regarded as green residences. To meet the heating demand of green residences, solar hot water systems and electricity-to-heat (E2H) conversion devices, such as ground source heat pumps electric heating stoves and electric water heaters are widely installed to provide a clean form of heat. Besides, common loads, such as lighting, washing, and electric vehicles are daily loads in green residences. The above electric and thermal loads are regarded as multi-energy heterogeneous loads MEHLs can be used to decarbonize green residences by optimizing energy dispatch through flexible control. In this study, a novel energy structure of green residences was extended through the combination of SHWs, E2H, GSHPs, and EVs, as well as rooftop photovoltaic systems. Then, to minimize carbon emissions, a residential energy dispatching model was designed from day-ahead and real-time scales and a low-carbon-oriented multi-energy heterogeneous loads coordinated control strategy was proposed. Finally, to mitigate the residents’ loss of comfort caused by MEHL control, the indoor environment and water tank temperatures and the state of charge of EVs were regarded as special constraints. The simulation revealed that the proposed strategy can reduce carbon emissions by 33.07% and meet the basic demand for residential heat and electricity. Additionally, the strategy has good applicability for decarbonizing green residences.
- 2 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (11) , 13711-13729
Analytical Damping Contribution Assessment Method of Multiconverters System Based on Energy Network Model
Multiconverters connected to grid can induce subsynchronous oscillation (SSO). This article proposed an analytical damping contribution assessment method that can explicitly reveal how (positively or negatively) and to which degree each converter in the multiconverters system changes the system stability level. First, the energy network model of the multiconverters system that satisfies energy conservation is proposed. On this basis, a theory proof is presented that the real part of eigenvalue of SSO mode in the multiconverters system is equal to the sum of coefficient in the aperiodic components of the derivative of dynamic energies injected by each converter and dissipation energy of network, which illustrates analytically how the SSO stability level is shaped. The dynamic energy showing a decreasing trend is good for the oscillation to disappear, and the faster the dynamic energy decreases, the faster the oscillation amplitude decreases. Thus, how and to which degree converter changes stability level can be revealed by the changing trend and rate of its dynamic energy, respectively. Moreover, the expression of dynamic energy is brief, which is, thus, readily for online use, and is universal for converters with different control strategies. Finally, hardware in loop tests verifies that, eliminate converters’ rapidly increasing dynamic energy, the unstable SSO converges rapidly, and eliminate converters’ slowly increasing dynamic energy, the unstable SSO converges but slowly, and eliminate converters’ decreasing dynamic energy, unstable SSO diverges more rapidly, which demonstrates that dynamic energy can precisely assess damping contribution of converter.
- 2 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (11) , 13711-13729
Analytical Damping Contribution Assessment Method of Multiconverters System Based on Energy Network Model
Multiconverters connected to grid can induce subsynchronous oscillation (SSO). This article proposed an analytical damping contribution assessment method that can explicitly reveal how (positively or negatively) and to which degree each converter in the multiconverters system changes the system stability level. First, the energy network model of the multiconverters system that satisfies energy conservation is proposed. On this basis, a theory proof is presented that the real part of eigenvalue of SSO mode in the multiconverters system is equal to the sum of coefficient in the aperiodic components of the derivative of dynamic energies injected by each converter and dissipation energy of network, which illustrates analytically how the SSO stability level is shaped. The dynamic energy showing a decreasing trend is good for the oscillation to disappear, and the faster the dynamic energy decreases, the faster the oscillation amplitude decreases. Thus, how and to which degree converter changes stability level can be revealed by the changing trend and rate of its dynamic energy, respectively. Moreover, the expression of dynamic energy is brief, which is, thus, readily for online use, and is universal for converters with different control strategies. Finally, hardware in loop tests verifies that, eliminate converters’ rapidly increasing dynamic energy, the unstable SSO converges rapidly, and eliminate converters’ slowly increasing dynamic energy, the unstable SSO converges but slowly, and eliminate converters’ decreasing dynamic energy, unstable SSO diverges more rapidly, which demonstrates that dynamic energy can precisely assess damping contribution of converter.
- 7 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 12 (4) , 2378-2392
Stability Analysis of Power Grid Connected With Direct-Drive Wind Farm Containing Virtual Inertia Based on Integrated Dissipation Energy Model
Concerning the difficulty in unified modeling of direct-drive wind farm with virtual inertia and the unknown cause of low frequency oscillation, a detailed model of integrated dissipation energy of direct-drive wind farm is built. First, the dissipation energy model of wind generator and the integrated dissipation energy model of direct-drive wind farm containing virtual inertia and PLL is derived and built. On this basis, according to different sources of integrated dissipation energy, it is decomposed into free dissipation energy, resonant dissipation energy and forced dissipation energy. These three components respectively characterize the contribution of inherent damping, generator-grid coupled resonance and generator-grid interaction to the stability of system. And then, how the variation of wind speed and generator location affects the stability of system is analyzed quantitatively using the integrated dissipation energy. Finally, the model of IEEE 10-machine 39-bus system connected with direct-drive wind farm is built in RTDS for hardware-in-the-loop tests. Simulation results verify that, the detailed model exhibits three different oscillation states, and each generator in the wind farm contributes differently to system oscillation. The traditional equivalent model of wind farm only exhibits one oscillation state and cannot reflect the difference in contributions of generators, thus it may wrongly identify the stability of system, even aggravate oscillation.
- 7 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 12 (4) , 2378-2392
Stability Analysis of Power Grid Connected With Direct-Drive Wind Farm Containing Virtual Inertia Based on Integrated Dissipation Energy Model
Concerning the difficulty in unified modeling of direct-drive wind farm with virtual inertia and the unknown cause of low frequency oscillation, a detailed model of integrated dissipation energy of direct-drive wind farm is built. First, the dissipation energy model of wind generator and the integrated dissipation energy model of direct-drive wind farm containing virtual inertia and PLL is derived and built. On this basis, according to different sources of integrated dissipation energy, it is decomposed into free dissipation energy, resonant dissipation energy and forced dissipation energy. These three components respectively characterize the contribution of inherent damping, generator-grid coupled resonance and generator-grid interaction to the stability of system. And then, how the variation of wind speed and generator location affects the stability of system is analyzed quantitatively using the integrated dissipation energy. Finally, the model of IEEE 10-machine 39-bus system connected with direct-drive wind farm is built in RTDS for hardware-in-the-loop tests. Simulation results verify that, the detailed model exhibits three different oscillation states, and each generator in the wind farm contributes differently to system oscillation. The traditional equivalent model of wind farm only exhibits one oscillation state and cannot reflect the difference in contributions of generators, thus it may wrongly identify the stability of system, even aggravate oscillation.
- 15 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (5) , 5542-5557
Interaction Energy-Based Stability Analysis Method and Application in Grid-Tied Type-4 Wind Turbine Generator
Complex dynamic interaction between type-4 wind turbine generator (WTG) and ac grid causes sub-synchronous oscillation (SSO). In view of this problem, this paper proposes a stability analysis method based on interaction energy that can explicitly reveal how (positively or negatively) and to which degree the various interaction links between subsystems in modular state-space model change system stability level. Firstly, an energy model representation for modular state-space model of grid-tied type-4 WTG system, containing stored energy terms, dissipation energy terms and interaction energy terms, is constructed and is proved to satisfy the condition of energy conservation. And then, according to Lyapunov’s 2nd stability principle, it reveals that the increasing of interaction energy term with time is what causes the system to go unstable. Besides, it points out that the interaction energy term has one to one relationship with interaction link. Thus, the effects of different interaction links on system stability level can be identified by analyzing the variation trend of different interaction energy terms. Finally, hardware-in-loop tests with RTLAB verify that, the dynamic interaction effects among different sub-systems are quantified according to the value of interaction energy. Thus, the interaction links that have large impact on system stability are selected, which can provide theoretical support for future adding compensation branches between sub-systems to suppress oscillation (i.e. supplementary compensation branch based damping control).
- 15 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (5) , 5542-5557
Interaction Energy-Based Stability Analysis Method and Application in Grid-Tied Type-4 Wind Turbine Generator
Complex dynamic interaction between type-4 wind turbine generator (WTG) and ac grid causes sub-synchronous oscillation (SSO). In view of this problem, this paper proposes a stability analysis method based on interaction energy that can explicitly reveal how (positively or negatively) and to which degree the various interaction links between subsystems in modular state-space model change system stability level. Firstly, an energy model representation for modular state-space model of grid-tied type-4 WTG system, containing stored energy terms, dissipation energy terms and interaction energy terms, is constructed and is proved to satisfy the condition of energy conservation. And then, according to Lyapunov’s 2nd stability principle, it reveals that the increasing of interaction energy term with time is what causes the system to go unstable. Besides, it points out that the interaction energy term has one to one relationship with interaction link. Thus, the effects of different interaction links on system stability level can be identified by analyzing the variation trend of different interaction energy terms. Finally, hardware-in-loop tests with RTLAB verify that, the dynamic interaction effects among different sub-systems are quantified according to the value of interaction energy. Thus, the interaction links that have large impact on system stability are selected, which can provide theoretical support for future adding compensation branches between sub-systems to suppress oscillation (i.e. supplementary compensation branch based damping control).
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (4) , 4169-4186
DFIG Active Damping Control Strategy Based on Remodeling of Multiple Energy Branches
Concerning sub-synchronous oscillation caused by the integration of DFIG to power grid via series compensation line, an active damping control strategy based on remodeling of multiple energy branches in DFIG is proposed. First, according to the flow path of oscillation components, DFIG energy branches are divided. Second, potential energy and dissipation energy are defined characterizing accumulation and consumption of energy during oscillation. By analyzing the contribution of energy branches to them, key energy branches affecting system stability are screened. On this basis, relations among stator voltage, potential energy and dissipation energy are established. Frequency-dependent energy compensation in key branches are derived. By assessing their impact on LVRT performance of DFIG, the compensation branches compatible with DFIG fundamental frequency characteristics are screened. Then, take sub/super-synchronous frequency stability coefficient ratio as objective, and requirement on stability in sub/super-synchronous frequency band as constraints. The compensation branch parameter optimization scheme is established. Finally, a test system is built in RT-LAB for verification. Simulation results demonstrate that, the proposed strategy can realize active damping control in multiple oscillation cases, and guarantee the stability in full frequency band. Besides, the strategy doesn't affect LVRT performance of DFIG and is well compatible with DFIG fundamental frequency characteristics.
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (4) , 4169-4186
DFIG Active Damping Control Strategy Based on Remodeling of Multiple Energy Branches
Concerning sub-synchronous oscillation caused by the integration of DFIG to power grid via series compensation line, an active damping control strategy based on remodeling of multiple energy branches in DFIG is proposed. First, according to the flow path of oscillation components, DFIG energy branches are divided. Second, potential energy and dissipation energy are defined characterizing accumulation and consumption of energy during oscillation. By analyzing the contribution of energy branches to them, key energy branches affecting system stability are screened. On this basis, relations among stator voltage, potential energy and dissipation energy are established. Frequency-dependent energy compensation in key branches are derived. By assessing their impact on LVRT performance of DFIG, the compensation branches compatible with DFIG fundamental frequency characteristics are screened. Then, take sub/super-synchronous frequency stability coefficient ratio as objective, and requirement on stability in sub/super-synchronous frequency band as constraints. The compensation branch parameter optimization scheme is established. Finally, a test system is built in RT-LAB for verification. Simulation results demonstrate that, the proposed strategy can realize active damping control in multiple oscillation cases, and guarantee the stability in full frequency band. Besides, the strategy doesn't affect LVRT performance of DFIG and is well compatible with DFIG fundamental frequency characteristics.