Phadke A.G
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Phadke A.G has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Jing Ma
State Key Laboratory of New Energy Power System, North China Electric Power University, Changping District, Beijing 102206, China
3 shared publications - Yaqi Shen
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
3 shared publications - Dong Zhao
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China
1 shared publication
Latest Publications
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (4) , 4169-4186
DFIG Active Damping Control Strategy Based on Remodeling of Multiple Energy Branches
Concerning sub-synchronous oscillation caused by the integration of DFIG to power grid via series compensation line, an active damping control strategy based on remodeling of multiple energy branches in DFIG is proposed. First, according to the flow path of oscillation components, DFIG energy branches are divided. Second, potential energy and dissipation energy are defined characterizing accumulation and consumption of energy during oscillation. By analyzing the contribution of energy branches to them, key energy branches affecting system stability are screened. On this basis, relations among stator voltage, potential energy and dissipation energy are established. Frequency-dependent energy compensation in key branches are derived. By assessing their impact on LVRT performance of DFIG, the compensation branches compatible with DFIG fundamental frequency characteristics are screened. Then, take sub/super-synchronous frequency stability coefficient ratio as objective, and requirement on stability in sub/super-synchronous frequency band as constraints. The compensation branch parameter optimization scheme is established. Finally, a test system is built in RT-LAB for verification. Simulation results demonstrate that, the proposed strategy can realize active damping control in multiple oscillation cases, and guarantee the stability in full frequency band. Besides, the strategy doesn't affect LVRT performance of DFIG and is well compatible with DFIG fundamental frequency characteristics.
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (4) , 4169-4186
DFIG Active Damping Control Strategy Based on Remodeling of Multiple Energy Branches
Concerning sub-synchronous oscillation caused by the integration of DFIG to power grid via series compensation line, an active damping control strategy based on remodeling of multiple energy branches in DFIG is proposed. First, according to the flow path of oscillation components, DFIG energy branches are divided. Second, potential energy and dissipation energy are defined characterizing accumulation and consumption of energy during oscillation. By analyzing the contribution of energy branches to them, key energy branches affecting system stability are screened. On this basis, relations among stator voltage, potential energy and dissipation energy are established. Frequency-dependent energy compensation in key branches are derived. By assessing their impact on LVRT performance of DFIG, the compensation branches compatible with DFIG fundamental frequency characteristics are screened. Then, take sub/super-synchronous frequency stability coefficient ratio as objective, and requirement on stability in sub/super-synchronous frequency band as constraints. The compensation branch parameter optimization scheme is established. Finally, a test system is built in RT-LAB for verification. Simulation results demonstrate that, the proposed strategy can realize active damping control in multiple oscillation cases, and guarantee the stability in full frequency band. Besides, the strategy doesn't affect LVRT performance of DFIG and is well compatible with DFIG fundamental frequency characteristics.
- 25 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (8) , 8074-8087
Stability Assessment of DFIG Subsynchronous Oscillation Based on Energy Dissipation Intensity Analysis
Concerning the sub-synchronous oscillation caused by the integration of DFIG to power grid via the series compensation circuit, a method to assess the stability of sub-synchronous oscillation based on the dissipation intensity is proposed. First, the transient energy that DFIG generates in one oscillation period is defined as the dynamic energy of DFIG, and the model of DFIG dynamic energy containing internal control and external networks is constructed. And then, according to Lyapunov stability theory, the negative gradient of dynamic energy is defined as the dissipation intensity, which reflects the dissipation effect of DFIG on the energy generated during oscillation. On this basis, the effect of the series compensation degree, PLL and converter control parameters on sub-synchronous oscillation is assessed and real-time assessment of the stability level of DFIG-integrated power system is realized. Finally, a simulation model is built in RT-LAB to verify the proposed method. Simulation results demonstrate that the stability level of system can be assessed accurately according to the value of dissipation intensity. When the value of dissipation intensity is positive, system oscillation converges. When the dissipation intensity is 0, system oscillates with constant-amplitude oscillation. When the value of dissipation intensity is negative, system oscillation diverges.
- 25 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (8) , 8074-8087
Stability Assessment of DFIG Subsynchronous Oscillation Based on Energy Dissipation Intensity Analysis
Concerning the sub-synchronous oscillation caused by the integration of DFIG to power grid via the series compensation circuit, a method to assess the stability of sub-synchronous oscillation based on the dissipation intensity is proposed. First, the transient energy that DFIG generates in one oscillation period is defined as the dynamic energy of DFIG, and the model of DFIG dynamic energy containing internal control and external networks is constructed. And then, according to Lyapunov stability theory, the negative gradient of dynamic energy is defined as the dissipation intensity, which reflects the dissipation effect of DFIG on the energy generated during oscillation. On this basis, the effect of the series compensation degree, PLL and converter control parameters on sub-synchronous oscillation is assessed and real-time assessment of the stability level of DFIG-integrated power system is realized. Finally, a simulation model is built in RT-LAB to verify the proposed method. Simulation results demonstrate that the stability level of system can be assessed accurately according to the value of dissipation intensity. When the value of dissipation intensity is positive, system oscillation converges. When the dissipation intensity is 0, system oscillates with constant-amplitude oscillation. When the value of dissipation intensity is negative, system oscillation diverges.
- 26 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 11 (3) , 1693-1706
Research on Positioning Method of Low Frequency Oscillating Source in DFIG-Integrated System With Virtual Inertia Control
Concerning the difficulty in locating the oscillating source of DFIG-integrated system with virtual inertia control, a method to track the low frequency oscillating source based on energy function is proposed. First, the dynamic energy function of DFIG containing PLL and virtual inertia control modules is constructed. On this basis, considering the effects of PLL and virtual inertia, the energy spectrum of synchronous generator and analogical energy spectrum of DFIG are established, and the characteristics of energy spectrums of oscillating-source and non-oscillating-source generators in the dominant oscillation mode are revealed. And then, according to the characteristic of energy spectrum, the similarity coefficients between energy spectrums of different generators in the frequency band in the vicinity of the dominant oscillation mode are calculated. Thus by comparing the similarity coefficients, system oscillating source in the dominant oscillation mode can be located. Finally, hardware-in-the-loop tests are conducted in RTDS (Real Time Digital Simulator) based on the IEEE 10-machine 39-bus system. Simulation results verify that, in a disturbed system with multiple oscillation modes, the proposed method can eliminate the effect of non-dominant oscillation mode on oscillating source locating and can realize accurate identification of oscillating-source generators even when the system is in complex operating conditions.
- 26 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 11 (3) , 1693-1706
Research on Positioning Method of Low Frequency Oscillating Source in DFIG-Integrated System With Virtual Inertia Control
Concerning the difficulty in locating the oscillating source of DFIG-integrated system with virtual inertia control, a method to track the low frequency oscillating source based on energy function is proposed. First, the dynamic energy function of DFIG containing PLL and virtual inertia control modules is constructed. On this basis, considering the effects of PLL and virtual inertia, the energy spectrum of synchronous generator and analogical energy spectrum of DFIG are established, and the characteristics of energy spectrums of oscillating-source and non-oscillating-source generators in the dominant oscillation mode are revealed. And then, according to the characteristic of energy spectrum, the similarity coefficients between energy spectrums of different generators in the frequency band in the vicinity of the dominant oscillation mode are calculated. Thus by comparing the similarity coefficients, system oscillating source in the dominant oscillation mode can be located. Finally, hardware-in-the-loop tests are conducted in RTDS (Real Time Digital Simulator) based on the IEEE 10-machine 39-bus system. Simulation results verify that, in a disturbed system with multiple oscillation modes, the proposed method can eliminate the effect of non-dominant oscillation mode on oscillating source locating and can realize accurate identification of oscillating-source generators even when the system is in complex operating conditions.