Philip S. Sauvé
Research Subjects
Philip S. Sauvé has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Y. Shin
Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, United States
2 shared publications Peter C. Rhee
Department of Trauma and Orthopedic Surgery, Queen Alexandra Hospital, Portsmouth, UK; Department of Orthopedic Surgery, San Antonio Military Medical Center, San Antonio, TX; Division of Hand Surgery, Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN; The Pulvertaft Hand Centre, Kings Treatment Center, Royal Derby Hospital, Derby, UK
2 shared publicationsTommy Lindau
Department of Trauma and Orthopedic Surgery, Queen Alexandra Hospital, Portsmouth, UK; Department of Orthopedic Surgery, San Antonio Military Medical Center, San Antonio, TX; Division of Hand Surgery, Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN; The Pulvertaft Hand Centre, Kings Treatment Center, Royal Derby Hospital, Derby, UK
2 shared publicationsAnkur Pandya
Plastic Surgery, Queen Alexandra Hospital, Portsmouth, GBR
1 shared publicationB. Higgins
University of Portsmouth, School of Health Sciences and Social Work, Gloucester House, Queen Alexandra Hospital, Southwick Hill Road, Cosham, Portsmouth PO6 3LY, United Kingdom
1 shared publication- Benjamin J.R.F. Bolland
Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter Hospital, Exeter, UK
1 shared publication
Latest Publications
- Open Access
- 6 January 2023
- Published by Springer Nature in Cureus
- Vol. 15 (1) , e33453
Lower Limb Serratia marcescens Necrotizing Fasciitis Complicated by Nosocomial COVID-19
Serratia marcescens represents an unusual yet potentially deadly cause of lower limb necrotizing fasciitis (NF). Compounding the already high mortality of NF, S. marcescens infections are usually associated with worse outcomes (i.e., amputation). Here we present the case of a 56-year-old immunocompromised man due to lupus nephritis who developed lower limb NF secondary to S. marcescens followed by nosocomial coronavirus disease 2019 (COVID-19) pneumonitis. Successful limb salvage was achieved through a multidisciplinary team approach from various specialties including plastic surgery, orthopedic surgery, anesthesiology, intensive care, respiratory medicine, and nephrology. At 11 months' follow-up, the patient was largely independent with activities of daily living and was able to ambulate. Unfortunately, he suffered a myocardial infarction at 19 months post-operatively and passed away. A review of the literature revealed only a handful of cases of lower limb NF due to S. marcescens and none with subsequent COVID-19. Therefore, this is the first report of such a case which should help with the clinical management of such cases going forward, especially with COVID-19 now becoming endemic in our communities and contributing to delayed presentations and increased mortality in NF.
- 6 January 2023
- Published by Springer Nature in Cureus
- Vol. 15 (1) , e33453
Open AccessLower Limb Serratia marcescens Necrotizing Fasciitis Complicated by Nosocomial COVID-19
Serratia marcescens represents an unusual yet potentially deadly cause of lower limb necrotizing fasciitis (NF). Compounding the already high mortality of NF, S. marcescens infections are usually associated with worse outcomes (i.e., amputation). Here we present the case of a 56-year-old immunocompromised man due to lupus nephritis who developed lower limb NF secondary to S. marcescens followed by nosocomial coronavirus disease 2019 (COVID-19) pneumonitis. Successful limb salvage was achieved through a multidisciplinary team approach from various specialties including plastic surgery, orthopedic surgery, anesthesiology, intensive care, respiratory medicine, and nephrology. At 11 months' follow-up, the patient was largely independent with activities of daily living and was able to ambulate. Unfortunately, he suffered a myocardial infarction at 19 months post-operatively and passed away. A review of the literature revealed only a handful of cases of lower limb NF due to S. marcescens and none with subsequent COVID-19. Therefore, this is the first report of such a case which should help with the clinical management of such cases going forward, especially with COVID-19 now becoming endemic in our communities and contributing to delayed presentations and increased mortality in NF.
- 1 October 2014
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 39 (10) , 2089-2092
Examination of the Wrist: Radial-Sided Wrist Pain
- 1 October 2014
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 39 (10) , 2089-2092
Examination of the Wrist: Radial-Sided Wrist Pain
- 1 September 2014
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 39 (9) , 1859-1862
Examination of the Wrist: Ulnar-Sided Wrist Pain Due to Ligamentous Injury
- 1 September 2014
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 39 (9) , 1859-1862
Examination of the Wrist: Ulnar-Sided Wrist Pain Due to Ligamentous Injury
- 12 February 2014
- Published by SAGE Publications in HAND
- Vol. 9 (4) , 516-521
Volar Locking Plate Fixation of Distal Radius Fractures: Use of an Intra-Operative ‘Carpal Shoot Through’ View to Identify Dorsal Compartment and Distal Radioulnar Joint Screw Penetration
Introduction: We report our experience using a ‘carpal shoot through’ view of the distal radius to identify dorsal compartment screw penetration intra-operatively when performing volar plating of the distal radius. Methods: A prospective study of 42 patients (mean age 56 years) with acute distal radius fractures treated with open reduction internal fixation was undertaken. Surgical fixation was performed using a volar locking plate in all patients. After plate application, inclined posteroanterior and lateral radiographs were taken followed by the carpal shoot through view. Results: In six cases (14 %), the carpal shoot through view revealed dorsal screw protrusion, which was not detectable on standard PA and lateral views. In one case, a screw had penetrated the distal radioulnar joint (DRUJ), which was only apparent on the shoot through view. The overall screw exchange rate was 17 %. Conclusions: Using the hand and carpus to minimise the contrast in X-ray penetration, the dorsal cortex of the distal radius may be imaged intra-operatively and dorsal compartment screw penetration detected in cases with significant multifragmentation when screw measurement is difficult. This view potentially reduces the risk of post-operative pain and extensor tendon injury and also provides excellent visualisation of the DRUJ.
- 12 February 2014
- Published by SAGE Publications in HAND
- Vol. 9 (4) , 516-521
Volar Locking Plate Fixation of Distal Radius Fractures: Use of an Intra-Operative ‘Carpal Shoot Through’ View to Identify Dorsal Compartment and Distal Radioulnar Joint Screw Penetration
Introduction: We report our experience using a ‘carpal shoot through’ view of the distal radius to identify dorsal compartment screw penetration intra-operatively when performing volar plating of the distal radius. Methods: A prospective study of 42 patients (mean age 56 years) with acute distal radius fractures treated with open reduction internal fixation was undertaken. Surgical fixation was performed using a volar locking plate in all patients. After plate application, inclined posteroanterior and lateral radiographs were taken followed by the carpal shoot through view. Results: In six cases (14 %), the carpal shoot through view revealed dorsal screw protrusion, which was not detectable on standard PA and lateral views. In one case, a screw had penetrated the distal radioulnar joint (DRUJ), which was only apparent on the shoot through view. The overall screw exchange rate was 17 %. Conclusions: Using the hand and carpus to minimise the contrast in X-ray penetration, the dorsal cortex of the distal radius may be imaged intra-operatively and dorsal compartment screw penetration detected in cases with significant multifragmentation when screw measurement is difficult. This view potentially reduces the risk of post-operative pain and extensor tendon injury and also provides excellent visualisation of the DRUJ.
- 3 March 2009
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 17 (5) , 551-554
Primary hyperparathyroidism presenting as delayed fracture union
We describe a case of delayed union in a tibial fracture secondary to primary hyperparathyroidism. A closed intra‐articular proximal tibia fracture was stabilized with a hybrid external fixator. At 5 months clinical and radiological evaluation failed to demonstrate evidence of fracture healing. Fixation was stable and inflammatory markers ruled out infection. Further questioning revealed symptoms of anorexia, nausea and constipation. Plasma biochemistry showed an elevated corrected calcium and parathyroid hormone concentration. Further investigation included a sestamibi scan which confirmed a diagnosis of hyperparathyroidism secondary to a parathyroid adenoma. Six weeks following partial parathyroidectomy the fracture site was pain free, non‐tender and the fracture had united radiologically. In cases of delayed‐union, once an infective cause has been excluded with a mechanically stable fracture, other causes of delayed union like primary hyperparathyroidism should be ruled out.
- 3 March 2009
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 17 (5) , 551-554
Primary hyperparathyroidism presenting as delayed fracture union
We describe a case of delayed union in a tibial fracture secondary to primary hyperparathyroidism. A closed intra‐articular proximal tibia fracture was stabilized with a hybrid external fixator. At 5 months clinical and radiological evaluation failed to demonstrate evidence of fracture healing. Fixation was stable and inflammatory markers ruled out infection. Further questioning revealed symptoms of anorexia, nausea and constipation. Plasma biochemistry showed an elevated corrected calcium and parathyroid hormone concentration. Further investigation included a sestamibi scan which confirmed a diagnosis of hyperparathyroidism secondary to a parathyroid adenoma. Six weeks following partial parathyroidectomy the fracture site was pain free, non‐tender and the fracture had united radiologically. In cases of delayed‐union, once an infective cause has been excluded with a mechanically stable fracture, other causes of delayed union like primary hyperparathyroidism should be ruled out.
- 1 March 2008
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 47 (2) , 80-88
Rheumatoid Forefoot Reconstruction: First Metatarsophalangeal Joint Fusion Combined with Weil’s Metatarsal Osteotomies of the Lesser Rays
- 1 March 2008
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 47 (2) , 80-88
Rheumatoid Forefoot Reconstruction: First Metatarsophalangeal Joint Fusion Combined with Weil’s Metatarsal Osteotomies of the Lesser Rays
- Open Access
- 1 May 2007
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 89-B (5) , 586-590
Metal ion levels after metal-on-metal Ring total hip replacement
Metal-on-metal bearings for total hip replacement (THR) are becoming increasingly popular. Improved wear characteristics mean that these articulations are being inserted into younger patients in the form of THR and resurfacing procedures. This has led to concerns regarding potential carcinogenicity because of the increased exposure to metal ions that the procedure brings. We have studied the serum cobalt and chromium concentrations in patients who had primary, well-fixed Ring metal-on-metal THRs for more than 30 years. The levels of cobalt and chromium were elevated by five and three times, respectively compared with those in our reference groups. Metal-on-metal articulations appear to be the source of metal ions throughout the life of the prosthesis. In three patients who had undergone revision of a previous metal-on-metal THR to a metal-on-polyethylene replacement the levels of metal ions were within the normal range. The elevations of cobalt and chromium ions seen in our study were comparable with those in patients with modern metal-on-metal THRs.
- 1 May 2007
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 89-B (5) , 586-590
Open AccessMetal ion levels after metal-on-metal Ring total hip replacement
Metal-on-metal bearings for total hip replacement (THR) are becoming increasingly popular. Improved wear characteristics mean that these articulations are being inserted into younger patients in the form of THR and resurfacing procedures. This has led to concerns regarding potential carcinogenicity because of the increased exposure to metal ions that the procedure brings. We have studied the serum cobalt and chromium concentrations in patients who had primary, well-fixed Ring metal-on-metal THRs for more than 30 years. The levels of cobalt and chromium were elevated by five and three times, respectively compared with those in our reference groups. Metal-on-metal articulations appear to be the source of metal ions throughout the life of the prosthesis. In three patients who had undergone revision of a previous metal-on-metal THR to a metal-on-polyethylene replacement the levels of metal ions were within the normal range. The elevations of cobalt and chromium ions seen in our study were comparable with those in patients with modern metal-on-metal THRs.