Abstract
Introduction: We report our experience using a ‘carpal shoot through’ view of the distal radius to identify dorsal compartment screw penetration intra-operatively when performing volar plating of the distal radius. Methods: A prospective study of 42 patients (mean age 56 years) with acute distal radius fractures treated with open reduction internal fixation was undertaken. Surgical fixation was performed using a volar locking plate in all patients. After plate application, inclined posteroanterior and lateral radiographs were taken followed by the carpal shoot through view. Results: In six cases (14 %), the carpal shoot through view revealed dorsal screw protrusion, which was not detectable on standard PA and lateral views. In one case, a screw had penetrated the distal radioulnar joint (DRUJ), which was only apparent on the shoot through view. The overall screw exchange rate was 17 %. Conclusions: Using the hand and carpus to minimise the contrast in X-ray penetration, the dorsal cortex of the distal radius may be imaged intra-operatively and dorsal compartment screw penetration detected in cases with significant multifragmentation when screw measurement is difficult. This view potentially reduces the risk of post-operative pain and extensor tendon injury and also provides excellent visualisation of the DRUJ.Keywords
This publication has 39 references indexed in Scilit:
- Dorsal Tangential View of the Wrist to Detect Screw Penetration to the Dorsal Cortex of the Distal Radius after Volar Fixed-Angle PlatingHAND, 2011
- Use of Articular Wrist Views to Assess Intra-Articular Screw Penetration in Surgical Fixation of Distal Radius FracturesThe Journal of Hand Surgery, 2010
- Use of Fluoroscopy in Determining Screw Overshoot in the Dorsal Distal Radius: A Cadaveric StudyThe Journal of Hand Surgery, 2009
- Radiographic Evaluation of Dorsal Screw Penetration after Volar Fixed-Angle Plating of the Distal Radius: A Cadaveric StudyHAND, 2007
- Volar Fixation for Dorsally Angulated Extra-Articular Fractures of the Distal Radius: A Biomechanical StudyThe Journal of Hand Surgery, 2006
- Functional Outcome and Complications After Volar Plating for Dorsally Displaced, Unstable Fractures of the Distal RadiusThe Journal of Hand Surgery, 2006
- Volar Versus Dorsal Plating in the Management of Intra-Articular Distal Radius FracturesThe Journal of Hand Surgery, 2006
- Volar Fixation of Dorsally Displaced Distal Radius Fractures Using the 2.4-mm Locking Compression PlatesThe Journal of Hand Surgery, 2005
- Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius: A brief reportThe Journal of Hand Surgery, 1998
- Extensor pollicis longus rupture at the tip of a prominent fixation screw: Report of three casesThe Journal of Hand Surgery, 1993