Andrzej Galecki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrzej Galecki has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Arkadiusz Kaszewski
Institute of Control and Industrial Electronics, Warsaw University of Technology, 75 Koszykowa Street, 00-662 Warsaw, Poland
7 shared publications - Bartlomiej Ufnalski
WARSAW UNIVERSITY OF TECHNOLOGY, Institute of Control and Industrial Electronics, 75 Koszykowa St., Warsaw 00-662, Poland
7 shared publications - Lech Marian Grzesiak
Institute of Control and Industrial Electronics, Warsaw University of Technology, Warsaw, Poland
7 shared publications - Marek Michalczuk
Department of Electrical Drive Division , Warsaw University of Technology, Institute of Control and Industrial Electronics , Warsaw , Poland
6 shared publications Piotr Rumniak
3 shared publications- Bogdan Bednarski
Faculty of Electrical Engineering, Institute of Control and Industrial Electronics, Warsaw University of Technology, Koszykowa 75, 00-662 Warsaw, Poland
1 shared publication
Latest Publications
- Open Access
- 30 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (4) , 4006-4015
Multithreaded State Controller for Grid-Connected Converter With Imposed Limits
This article proposes an innovative approach to control a grid-connected converter. The method combines the versatility and high-quality control offered by the state-feedback controllers for linear plants with the ease of imposing limits on the controlled variables offered by the cascaded control systems. The method is groundbreaking in its ability to bridge the gap between the elegance of the full-state-feedback control structure and its lack of popularity among power electronics engineers and possibly also other groups of practitioners. A multithreaded state controller is proposed in the form of three state controllers: one to control grid currents and dc-link voltage if limits of the currents are not reached, and two state controllers that are put into the closed loop if one of the current limits is reached. A complete design procedure is proposed, including the selection of all gains present in the three state-feedback controllers using the pole placement method. An algorithm of soft switching between the three control signals is also developed. Sharing the desired dynamics between the threads is fulfilled thanks to the eigenstructure assignment introduced to overcome the problem of multiple solutions by choosing the most orthogonal eigenvectors. The proposed control system is then verified in a simulation, and its high practicality is demonstrated experimentally.
- 30 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (4) , 4006-4015
Open AccessMultithreaded State Controller for Grid-Connected Converter With Imposed Limits
This article proposes an innovative approach to control a grid-connected converter. The method combines the versatility and high-quality control offered by the state-feedback controllers for linear plants with the ease of imposing limits on the controlled variables offered by the cascaded control systems. The method is groundbreaking in its ability to bridge the gap between the elegance of the full-state-feedback control structure and its lack of popularity among power electronics engineers and possibly also other groups of practitioners. A multithreaded state controller is proposed in the form of three state controllers: one to control grid currents and dc-link voltage if limits of the currents are not reached, and two state controllers that are put into the closed loop if one of the current limits is reached. A complete design procedure is proposed, including the selection of all gains present in the three state-feedback controllers using the pole placement method. An algorithm of soft switching between the three control signals is also developed. Sharing the desired dynamics between the threads is fulfilled thanks to the eigenstructure assignment introduced to overcome the problem of multiple solutions by choosing the most orthogonal eigenvectors. The proposed control system is then verified in a simulation, and its high practicality is demonstrated experimentally.
- 10 March 2023
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (3) , 32-37
Właściwości przekształtnika sieciowego z filtrem LCL ze sprzężeniem od wspólnego pomiaru prądów cewek filtru
Artykuł przedstawia właściwości układu przekształtnika sieciowego z filtrem typu LCL z wykorzystaniem sprzężenia od wspólnego pomiaru prądu cewek filtru. Przedstawiono analizę porównawczą układów wykorzystujących sprzężenie od pojedynczego prądu jednej bądź drugiej cewki filtru LCL oraz możliwości poprawy odpowiedzi na wymuszenie prądu zadanego w układzie ze sprzężeniem zawierającym wyłącznie człon proporcjonalny. Przedstawiono wyniki symulacji i eksperymentu potwierdzającego pewne korzystne cechy wykorzystania wspólnego czujnika prądu.
- 10 March 2023
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (3) , 32-37
Właściwości przekształtnika sieciowego z filtrem LCL ze sprzężeniem od wspólnego pomiaru prądów cewek filtru
Artykuł przedstawia właściwości układu przekształtnika sieciowego z filtrem typu LCL z wykorzystaniem sprzężenia od wspólnego pomiaru prądu cewek filtru. Przedstawiono analizę porównawczą układów wykorzystujących sprzężenie od pojedynczego prądu jednej bądź drugiej cewki filtru LCL oraz możliwości poprawy odpowiedzi na wymuszenie prądu zadanego w układzie ze sprzężeniem zawierającym wyłącznie człon proporcjonalny. Przedstawiono wyniki symulacji i eksperymentu potwierdzającego pewne korzystne cechy wykorzystania wspólnego czujnika prądu.
- Open Access
- 18 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 88211-88225
Robust Tuning of Multiresonant Current Controllers for Grid-Tied Converters and Erroneous Use of the Naslin Polynomial Method
The majority of the paper is devoted to debunking flawed methods proposed in the literature within the context of multiresonant control systems for grid-connected converters and then a novel approach is proposed. Several flawed approaches to grid tied power electronic converters (rectifiers and shunt active power filters) are discussed to initiate a critical discussion regarding some tuning methods reported in the topical literature. In this paper we analytically show that some of them are even erroneous from the control theory point of view or are based on mathematically erroneous derivations. That is especially prevalent for papers in which the Naslin polynomial method is employed to tune proportional-multiresonant controllers. Some authors recognize that the resulting control systems are not robust, i.e. not practical, and use obtained gains only as a starting point for further tuning using the trial and error method or evolutionary global optimization. Robustness of such systems is often not guaranteed and if it occurs at all, it is by chance or thanks to a combination of luck and expert knowledge of the engineer (not by deliberate design). Therefore, the absence of such a guarantee motivates the search for better ways to tune such controllers. As a result, a practical robust controller tuning method for multiresonant grid current controllers is proposed and verified experimentally. We are convinced that one of the solutions can be based on the disk margin stability analysis and a global search algorithm. The required robustness is expressed as stability margins. The design procedure is very user-friendly and the disk size is the key design parameter to be selected by an engineer. The practicality of the tuning method is demonstrated empirically in a 10 kVA physical grid-tied converter.
- 18 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 88211-88225
Open AccessRobust Tuning of Multiresonant Current Controllers for Grid-Tied Converters and Erroneous Use of the Naslin Polynomial Method
The majority of the paper is devoted to debunking flawed methods proposed in the literature within the context of multiresonant control systems for grid-connected converters and then a novel approach is proposed. Several flawed approaches to grid tied power electronic converters (rectifiers and shunt active power filters) are discussed to initiate a critical discussion regarding some tuning methods reported in the topical literature. In this paper we analytically show that some of them are even erroneous from the control theory point of view or are based on mathematically erroneous derivations. That is especially prevalent for papers in which the Naslin polynomial method is employed to tune proportional-multiresonant controllers. Some authors recognize that the resulting control systems are not robust, i.e. not practical, and use obtained gains only as a starting point for further tuning using the trial and error method or evolutionary global optimization. Robustness of such systems is often not guaranteed and if it occurs at all, it is by chance or thanks to a combination of luck and expert knowledge of the engineer (not by deliberate design). Therefore, the absence of such a guarantee motivates the search for better ways to tune such controllers. As a result, a practical robust controller tuning method for multiresonant grid current controllers is proposed and verified experimentally. We are convinced that one of the solutions can be based on the disk margin stability analysis and a global search algorithm. The required robustness is expressed as stability margins. The design procedure is very user-friendly and the disk size is the key design parameter to be selected by an engineer. The practicality of the tuning method is demonstrated empirically in a 10 kVA physical grid-tied converter.
- Open Access
Influence of Microstepping Signal Shape on Shaft Movement Precision and Torque Variation of the Stepper Motor
Stepper motors are widely used in many applications where discrete, precise movement is required. There is a variety of dedicated stepper motor controllers (sometimes referred to as “step sticks”) available on the market. Those controllers provide a number of different motor control schemes that vary by aspects like current control method, reference current shape or maximum resolution increase (microstepping). The two most widely acknowledged signal shapes are sine-cosine microstepping and quadrature microstepping. The choice of the control scheme impacts torque output, torque variation, positioning error and maximum power supply requirements. This paper presents a family of generalised microstepping signal shapes, ranging from sine-cosine microstepping to quadrature microstepping. Derivation of signal shapes as well as their mathematical analyses are provided. Those signals are then implemented on the control board. A series of experiments is performed on a test bench to analyse the influence of different signal shapes on the performance of the motor in both load and no load conditions. The comparison of the new generalized shapes influence on the motor operation to the commonly used sine-cosine and quadrature control is provided.
Open AccessInfluence of Microstepping Signal Shape on Shaft Movement Precision and Torque Variation of the Stepper Motor
Stepper motors are widely used in many applications where discrete, precise movement is required. There is a variety of dedicated stepper motor controllers (sometimes referred to as “step sticks”) available on the market. Those controllers provide a number of different motor control schemes that vary by aspects like current control method, reference current shape or maximum resolution increase (microstepping). The two most widely acknowledged signal shapes are sine-cosine microstepping and quadrature microstepping. The choice of the control scheme impacts torque output, torque variation, positioning error and maximum power supply requirements. This paper presents a family of generalised microstepping signal shapes, ranging from sine-cosine microstepping to quadrature microstepping. Derivation of signal shapes as well as their mathematical analyses are provided. Those signals are then implemented on the control board. A series of experiments is performed on a test bench to analyse the influence of different signal shapes on the performance of the motor in both load and no load conditions. The comparison of the new generalized shapes influence on the motor operation to the commonly used sine-cosine and quadrature control is provided.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. P.1-P.8
Multifunctional energy storage system for smart grid applications
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. P.1-P.8
Multifunctional energy storage system for smart grid applications
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-10
State current controller with oscillatory terms for three-level grid-connected PWM rectifiers under distorted grid voltage conditions
This paper presents the design of a control system of a three-phase three-level pulse-width modulated rectifier operated under unbalanced and distorted grid voltage conditions. The developed scheme is based on a voltage-oriented control method. Instead of proportional-integral current controllers a state-feedback current controller in rotating reference frame is used. In order to achieve a zero steady-state current control error in response to step commands, integral terms are incorporated into the current control scheme. Similarly, to ensure the rejection of the sinusoidal component of current control error caused by unbalance and distortion in the grid voltage, the oscillatory terms are added to the current control system. To calculate the current controller gains, an augmented plant model is developed and linear-quadratic optimization method is applied. The physical experiments indicate that using state-feedback current control with oscillatory terms allows for notable improvement of the shape of the input currents of the converter and increases the power conversion efficiency.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-10
State current controller with oscillatory terms for three-level grid-connected PWM rectifiers under distorted grid voltage conditions
This paper presents the design of a control system of a three-phase three-level pulse-width modulated rectifier operated under unbalanced and distorted grid voltage conditions. The developed scheme is based on a voltage-oriented control method. Instead of proportional-integral current controllers a state-feedback current controller in rotating reference frame is used. In order to achieve a zero steady-state current control error in response to step commands, integral terms are incorporated into the current control scheme. Similarly, to ensure the rejection of the sinusoidal component of current control error caused by unbalance and distortion in the grid voltage, the oscillatory terms are added to the current control system. To calculate the current controller gains, an augmented plant model is developed and linear-quadratic optimization method is applied. The physical experiments indicate that using state-feedback current control with oscillatory terms allows for notable improvement of the shape of the input currents of the converter and increases the power conversion efficiency.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 191-196
LQ current control for three-phase PWM rectifiers under unbalanced grid voltage conditions
This paper presents a synthesis of a control system of a three-phase three-level PWM rectifier operated under unbalanced grid voltage conditions. The main goal is to obtain balanced grid currents. The proposed control method contains a PI dc-link voltage controller and an inner state feedback current controller coordinated in synchronous reference frame. The state-space model, which describes the dynamics of an input L-type filter of the rectifier, is augmented by a disturbance model that contains integral and oscillatory terms. Moreover, two approaches of reference tracking are considered. In order to determine the current controller gains, linear-quadratic (LQ) optimization is used. The discussed issues are illustrated by experimental results to validate the accuracy of the proposed control design.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 191-196
LQ current control for three-phase PWM rectifiers under unbalanced grid voltage conditions
This paper presents a synthesis of a control system of a three-phase three-level PWM rectifier operated under unbalanced grid voltage conditions. The main goal is to obtain balanced grid currents. The proposed control method contains a PI dc-link voltage controller and an inner state feedback current controller coordinated in synchronous reference frame. The state-space model, which describes the dynamics of an input L-type filter of the rectifier, is augmented by a disturbance model that contains integral and oscillatory terms. Moreover, two approaches of reference tracking are considered. In order to determine the current controller gains, linear-quadratic (LQ) optimization is used. The discussed issues are illustrated by experimental results to validate the accuracy of the proposed control design.
- 5 January 2015
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (1) , 67-71
Control system of the grid-connected converter based on a state current regulator with oscillatory terms
- 5 January 2015
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (1) , 67-71
Control system of the grid-connected converter based on a state current regulator with oscillatory terms