Rajiv S. Deshpande
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rajiv S. Deshpande has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Felix Werner Wehrli
Department of Radiology Perelman School of Medicine, University of Pennsylvania Philadelphia Pennsylvania USA
4 shared publications Michael C. Langham
Department of Radiology, Perelman School of Medicine University of Pennsylvania Philadelphia Pennsylvania USA
3 shared publications- Alexander A. Spector
Novosibirsk State Technical University, Russian Federation
2 shared publications - Nada Kamona
Department of Radiology, Perelman School of Medicine University of Pennsylvania Philadelphia Pennsylvania USA
2 shared publications Allison Hu
Division of Plastic, Reconstructive and Oral Surgery Children's Hospital of Philadelphia Philadelphia Pennsylvania USA
1 shared publicationBrian‐Tinh D. Vu
Department of Radiology, Perelman School of Medicine University of Pennsylvania Philadelphia Pennsylvania USA
1 shared publication
Latest Publications
- Open Access
- 29 October 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (3) , 1513-1527
DREAMER : Rapid and Simultaneous Multiple Contrast Magnetic Resonance Imaging of Solid and Soft Tissue
Purpose: Pediatric craniofacial imaging may involve examination of both the skull and brain tissues via CT and MRI, respectively. DREAMER (Dual Repetition and Echo Acquisition with Multi‐contrast Encoding and Reconstruction) simultaneously acquires solid‐ and soft‐tissue images, potentially providing a rapid, high‐resolution, and radiation‐free protocol whenever bone‐selective, T 1 w, and T 2 w images are required. Methods: The DREAMER sequence combines a solid‐state MRI method with phase‐based T 2 encoding to produce a multi‐contrast signal model that enables retrospective customization of image contrast weighting. DREAMER is paired with an iterative image reconstruction algorithm for accelerated and high‐resolution structural imaging of solid‐ and soft‐tissue compartments. Two healthy adult volunteers and two pediatric patients were scanned at 3 T to qualitatively compare soft‐tissue DREAMER image contrasts with their corresponding clinical standards, T 1 w MPRAGE and T 2 w fast spin‐echo (FSE). Two patients also underwent clinical CT to compare the bone‐selective images and skull renderings. Results: DREAMER images are self‐registered, high‐resolution, and spatially isotropic. The bone‐selective, T 1 w, and T 2 w images approximate the image contrasts and structural imaging capabilities of their corresponding clinical standards (CT, T 1 w MPRAGE, and T 2 w FSE). Unlike the standard techniques, DREAMER imaging occurs at a single scanner using a single pulse sequence. Conclusion: DREAMER combines mechanisms for solid‐ and multiple‐contrast soft‐tissue imaging into a single scan. For craniofacial imaging, DREAMER may consolidate CT and MRI demand, reduce exposure to ionizing radiation, decrease patient examination and wait times, and simplify the radiological workflow.
- 29 October 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (3) , 1513-1527
Open AccessDREAMER : Rapid and Simultaneous Multiple Contrast Magnetic Resonance Imaging of Solid and Soft Tissue
Purpose: Pediatric craniofacial imaging may involve examination of both the skull and brain tissues via CT and MRI, respectively. DREAMER (Dual Repetition and Echo Acquisition with Multi‐contrast Encoding and Reconstruction) simultaneously acquires solid‐ and soft‐tissue images, potentially providing a rapid, high‐resolution, and radiation‐free protocol whenever bone‐selective, T 1 w, and T 2 w images are required. Methods: The DREAMER sequence combines a solid‐state MRI method with phase‐based T 2 encoding to produce a multi‐contrast signal model that enables retrospective customization of image contrast weighting. DREAMER is paired with an iterative image reconstruction algorithm for accelerated and high‐resolution structural imaging of solid‐ and soft‐tissue compartments. Two healthy adult volunteers and two pediatric patients were scanned at 3 T to qualitatively compare soft‐tissue DREAMER image contrasts with their corresponding clinical standards, T 1 w MPRAGE and T 2 w fast spin‐echo (FSE). Two patients also underwent clinical CT to compare the bone‐selective images and skull renderings. Results: DREAMER images are self‐registered, high‐resolution, and spatially isotropic. The bone‐selective, T 1 w, and T 2 w images approximate the image contrasts and structural imaging capabilities of their corresponding clinical standards (CT, T 1 w MPRAGE, and T 2 w FSE). Unlike the standard techniques, DREAMER imaging occurs at a single scanner using a single pulse sequence. Conclusion: DREAMER combines mechanisms for solid‐ and multiple‐contrast soft‐tissue imaging into a single scan. For craniofacial imaging, DREAMER may consolidate CT and MRI demand, reduce exposure to ionizing radiation, decrease patient examination and wait times, and simplify the radiological workflow.
- Open Access
- 25 May 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (4) , 1529-1545
MRI ‐based quantification of whole‐organ renal metabolic rate of oxygen during free‐breathing
Purpose: Renal metabolic rate of oxygen (rMRO 2 ) reflects the kidney's metabolic efficiency, making it a potential biomarker for early‐stage kidney disease. This study introduces an ungated, free‐breathing MRI sequence in comparison to its breath‐hold counterpart to noninvasively measure whole‐organ rMRO 2 . Methods: Free‐breathing (FB) K‐MOTIVE sequence (kidney metabolism of oxygen via T 2 and interleaved velocity encoding) was developed to simultaneously measure renal blood flow rate (BFR) and T 2 of blood water using the conservation of mass. T 2 is converted to venous oxygen saturation (SvO 2 ) using a calibration curve. Compared to previous versions, FB K‐MOTIVE minimizes respiratory motion artifacts by acquiring fully sampled velocity maps with spiral readout instead of partially collecting radial views at each T 2 weighting. Healthy participants ( n = 15, 32 ± 9 years) were imaged at 3 T at the renal veins to quantify individual rMRO 2 , and at the suprarenal and infrarenal inferior vena cava to indirectly quantify bilateral rMRO 2 (the total metabolism from both kidneys). Results: Renal venous blood was highly oxygenated (SvO 2 91% ± 3%) and exhibited high BFR of 460 ± 90 mL/min per kidney. Further, total rMRO 2 of the two kidneys (160 ± 80 (μmol O 2 /min)/100 g) was statistically comparable to the indirect bilateral rMRO 2 (250 ± 120 (μmol O 2 /min)/100 g, p = 0.066). Using Lin's concordance correlation coefficient, there was good agreement between breath‐hold and free‐breathing acquisitions at the individual kidneys for SvO 2 (>0.75), BFR (>0.96), and rMRO 2 (>0.75). Conclusion: FB K‐MOTIVE is a feasible approach to estimate rMRO 2 , yielding reproducible and physiologically plausible metabolic parameters. Free‐breathing acquisition can enhance patient comfort by eliminating the need for breath‐holding.
- 25 May 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (4) , 1529-1545
Open AccessMRI ‐based quantification of whole‐organ renal metabolic rate of oxygen during free‐breathing
Purpose: Renal metabolic rate of oxygen (rMRO 2 ) reflects the kidney's metabolic efficiency, making it a potential biomarker for early‐stage kidney disease. This study introduces an ungated, free‐breathing MRI sequence in comparison to its breath‐hold counterpart to noninvasively measure whole‐organ rMRO 2 . Methods: Free‐breathing (FB) K‐MOTIVE sequence (kidney metabolism of oxygen via T 2 and interleaved velocity encoding) was developed to simultaneously measure renal blood flow rate (BFR) and T 2 of blood water using the conservation of mass. T 2 is converted to venous oxygen saturation (SvO 2 ) using a calibration curve. Compared to previous versions, FB K‐MOTIVE minimizes respiratory motion artifacts by acquiring fully sampled velocity maps with spiral readout instead of partially collecting radial views at each T 2 weighting. Healthy participants ( n = 15, 32 ± 9 years) were imaged at 3 T at the renal veins to quantify individual rMRO 2 , and at the suprarenal and infrarenal inferior vena cava to indirectly quantify bilateral rMRO 2 (the total metabolism from both kidneys). Results: Renal venous blood was highly oxygenated (SvO 2 91% ± 3%) and exhibited high BFR of 460 ± 90 mL/min per kidney. Further, total rMRO 2 of the two kidneys (160 ± 80 (μmol O 2 /min)/100 g) was statistically comparable to the indirect bilateral rMRO 2 (250 ± 120 (μmol O 2 /min)/100 g, p = 0.066). Using Lin's concordance correlation coefficient, there was good agreement between breath‐hold and free‐breathing acquisitions at the individual kidneys for SvO 2 (>0.75), BFR (>0.96), and rMRO 2 (>0.75). Conclusion: FB K‐MOTIVE is a feasible approach to estimate rMRO 2 , yielding reproducible and physiologically plausible metabolic parameters. Free‐breathing acquisition can enhance patient comfort by eliminating the need for breath‐holding.
- 26 December 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (5) , 2057-2073
Quantification of whole‐organ individual and bilateral renal metabolic rate of oxygen
Purpose: Renal metabolic rate of oxygen (rMRO2) is a potentially important biomarker of kidney function. The key parameters for rMRO2 quantification include blood flow rate (BFR) and venous oxygen saturation (SvO2) in a draining vessel. Previous approaches to quantify renal metabolism have focused on the single organ. Here, both kidneys are considered as one unit to quantify bilateral rMRO2. A pulse sequence to facilitate bilateral rMRO2 quantification is introduced.Methods: To quantify bilateral rMRO2, measurements of BFR and SvO2 are made along the inferior vena cava (IVC) at suprarenal and infrarenal locations. From the continuity equation, these four parameters can be related to derive an expression for bilateral rMRO2. The recently reported K‐MOTIVE pulse sequence was implemented at four locations: left kidney, right kidney, suprarenal IVC, and infrarenal IVC. A dual‐band variant of K‐MOTIVE (db‐K‐MOTIVE) was developed by incorporating simultaneous‐multi‐slice imaging principles. The sequence simultaneously measures BFR and SvO2 at suprarenal and infrarenal locations in a single pass of 21 s, yielding bilateral rMRO2.Results: SvO2 and BFR are higher in suprarenal versus infrarenal IVC, and the renal veins are highly oxygenated (SvO2 >90%). Bilateral rMRO2 quantified in 10 healthy subjects (8 M, 30 ± 8 y) was found to be 291 ± 247 and 349 ± 300 (μmolO2/min)/100 g, derived from K‐MOTIVE and db‐K‐MOTIVE, respectively. In comparison, total rMRO2 from combining left and right was 329 ± 273 (μmolO2/min)/100 g.Conclusion: The present work demonstrates that bilateral rMRO2 quantification is feasible with fair reproducibility and physiological plausibility. The indirect method is a promising approach to compute bilateral rMRO2 when individual rMRO2 quantification is difficult.
- 26 December 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (5) , 2057-2073
Quantification of whole‐organ individual and bilateral renal metabolic rate of oxygen
Purpose: Renal metabolic rate of oxygen (rMRO2) is a potentially important biomarker of kidney function. The key parameters for rMRO2 quantification include blood flow rate (BFR) and venous oxygen saturation (SvO2) in a draining vessel. Previous approaches to quantify renal metabolism have focused on the single organ. Here, both kidneys are considered as one unit to quantify bilateral rMRO2. A pulse sequence to facilitate bilateral rMRO2 quantification is introduced.Methods: To quantify bilateral rMRO2, measurements of BFR and SvO2 are made along the inferior vena cava (IVC) at suprarenal and infrarenal locations. From the continuity equation, these four parameters can be related to derive an expression for bilateral rMRO2. The recently reported K‐MOTIVE pulse sequence was implemented at four locations: left kidney, right kidney, suprarenal IVC, and infrarenal IVC. A dual‐band variant of K‐MOTIVE (db‐K‐MOTIVE) was developed by incorporating simultaneous‐multi‐slice imaging principles. The sequence simultaneously measures BFR and SvO2 at suprarenal and infrarenal locations in a single pass of 21 s, yielding bilateral rMRO2.Results: SvO2 and BFR are higher in suprarenal versus infrarenal IVC, and the renal veins are highly oxygenated (SvO2 >90%). Bilateral rMRO2 quantified in 10 healthy subjects (8 M, 30 ± 8 y) was found to be 291 ± 247 and 349 ± 300 (μmolO2/min)/100 g, derived from K‐MOTIVE and db‐K‐MOTIVE, respectively. In comparison, total rMRO2 from combining left and right was 329 ± 273 (μmolO2/min)/100 g.Conclusion: The present work demonstrates that bilateral rMRO2 quantification is feasible with fair reproducibility and physiological plausibility. The indirect method is a promising approach to compute bilateral rMRO2 when individual rMRO2 quantification is difficult.
- 14 June 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (3) , 1229-1243
Metabolism of oxygen via T2 and interleaved velocity encoding: A rapid method to quantify whole‐brain cerebral metabolic rate of oxygen
Purpose: Cerebral metabolic rate of oxygen (CMRO2) is an important biomarker of brain function. Key physiological parameters required to quantify CMRO2 include blood flow rate in the feeding arteries and venous oxygen saturation (SvO2) in the draining vein. Here, a pulse sequence, metabolism of oxygen via T2 and interleaved velocity encoding (MOTIVE), was developed to measure both parameters simultaneously and enable CMRO2 quantification in a single pass.Methods: The MOTIVE sequence interleaves a phase‐contrast module between a nonselective saturation and a background‐suppressed T2‐prepared EPI readout (BGS‐EPI) to measure T2 of blood water protons and cerebral blood flow in 20 s or less. The MOTIVE and standalone BGS‐EPI sequences were compared against TRUST (“T2 relaxation under spin tagging”) in the brain in healthy subjects (N = 24). Variants of MOTIVE to enhance resolution or shorten scan time were explored. Intrasession and intersession reproducibility studies were performed.Results: MOTIVE experiments yielded an average SvO2 of 61 ± 6% in the superior sagittal sinus of the brain and an average cerebral blood flow of 56 ± 10 ml/min/100 g. The bias in SvO2 of MOTIVE and BGS‐EPI to TRUST was +2 ± 4% and +1 ± 3%, respectively. The bias in cerebral blood flow of MOTIVE to Cartesian phase‐contrast reference was +1 ± 6 ml/min/100 g.Conclusions: The MOTIVE sequence is an advance over existing T2‐based oximetric methods. It does not require a control image and simultaneously measures SvO2 and flow velocity. The measurements agree well with TRUST and reference phase‐contrast sequences. This noninvasive technique enables CMRO2 quantification in under 20 s and is reproducible for in vivo applications.
- 14 June 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (3) , 1229-1243
Metabolism of oxygen via T2 and interleaved velocity encoding: A rapid method to quantify whole‐brain cerebral metabolic rate of oxygen
Purpose: Cerebral metabolic rate of oxygen (CMRO2) is an important biomarker of brain function. Key physiological parameters required to quantify CMRO2 include blood flow rate in the feeding arteries and venous oxygen saturation (SvO2) in the draining vein. Here, a pulse sequence, metabolism of oxygen via T2 and interleaved velocity encoding (MOTIVE), was developed to measure both parameters simultaneously and enable CMRO2 quantification in a single pass.Methods: The MOTIVE sequence interleaves a phase‐contrast module between a nonselective saturation and a background‐suppressed T2‐prepared EPI readout (BGS‐EPI) to measure T2 of blood water protons and cerebral blood flow in 20 s or less. The MOTIVE and standalone BGS‐EPI sequences were compared against TRUST (“T2 relaxation under spin tagging”) in the brain in healthy subjects (N = 24). Variants of MOTIVE to enhance resolution or shorten scan time were explored. Intrasession and intersession reproducibility studies were performed.Results: MOTIVE experiments yielded an average SvO2 of 61 ± 6% in the superior sagittal sinus of the brain and an average cerebral blood flow of 56 ± 10 ml/min/100 g. The bias in SvO2 of MOTIVE and BGS‐EPI to TRUST was +2 ± 4% and +1 ± 3%, respectively. The bias in cerebral blood flow of MOTIVE to Cartesian phase‐contrast reference was +1 ± 6 ml/min/100 g.Conclusions: The MOTIVE sequence is an advance over existing T2‐based oximetric methods. It does not require a control image and simultaneously measures SvO2 and flow velocity. The measurements agree well with TRUST and reference phase‐contrast sequences. This noninvasive technique enables CMRO2 quantification in under 20 s and is reproducible for in vivo applications.
- Open Access
- 20 January 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , srep40639
Modeling Stem Cell Myogenic Differentiation
The process of stem cell myogenesis (transformation into skeletal muscle cells) includes several stages characterized by the expression of certain combinations of myogenic factors. The first part of this process is accompanied by cell division, while the second part is mainly associated with direct differentiation. The mechanical cues are known to enhance stem cell myogenesis, and the paper focuses on the stem cell differentiation under the condition of externally applied strain. The process of stem cell myogenic differentiation is interpreted as the interplay among transcription factors, targeted proteins and strain-generated signaling molecule, and it is described by a kinetic multi-stage model. The model parameters are optimally adjusted by using the available data from the experiment with adipose-derived stem cells subjected to the application of cyclic uniaxial strains of the magnitude of 10%. The modeling results predict the kinetics of the process of myogenic differentiation, including the number of cells in each stage of differentiation and the rates of differentiation from one stage to another for different strains from 4% to 16%. The developed model can help better understand the process of myogenic differentiation and the effects of mechanical cues on stem cell use in muscle therapies.
- 20 January 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , srep40639
Open AccessModeling Stem Cell Myogenic Differentiation
The process of stem cell myogenesis (transformation into skeletal muscle cells) includes several stages characterized by the expression of certain combinations of myogenic factors. The first part of this process is accompanied by cell division, while the second part is mainly associated with direct differentiation. The mechanical cues are known to enhance stem cell myogenesis, and the paper focuses on the stem cell differentiation under the condition of externally applied strain. The process of stem cell myogenic differentiation is interpreted as the interplay among transcription factors, targeted proteins and strain-generated signaling molecule, and it is described by a kinetic multi-stage model. The model parameters are optimally adjusted by using the available data from the experiment with adipose-derived stem cells subjected to the application of cyclic uniaxial strains of the magnitude of 10%. The modeling results predict the kinetics of the process of myogenic differentiation, including the number of cells in each stage of differentiation and the rates of differentiation from one stage to another for different strains from 4% to 16%. The developed model can help better understand the process of myogenic differentiation and the effects of mechanical cues on stem cell use in muscle therapies.
- Open Access
- 26 October 2015
- Published by Frontiers Media SA in Frontiers in Neuroanatomy
- Vol. 9, 138
Construction and application of human neonatal DTI atlases
Atlas-based analysis is one of many analytical methods and is used to investigate typical as well as abnormal neurodevelopment. It has been widely applied to the adult and pediatric populations. Successful applications of atlas-based analysis (ABA) in those cohorts have motivated the creation of a neonatal atlas and parcellation map. The purpose of this review is to discuss the various neonatal diffusion tensor imaging (DTI) atlases that are available for use in ABA, examine how such atlases are constructed, review their applications, and observe future directions in DTI. Neonatal DTI atlases are created from a template, which can be study-specific or standardized, and merged with the corresponding parcellation map. Study-specific templates can retain higher image registration accuracy, but are usually not applicable across different studies. However, standardized templates can be used to make comparisons among various studies, but may not accurately reflect the anatomies of the study population. Methods such as volume-based template estimation are being developed to overcome these limitations. The applications for ABA, including atlas-based image quantification and atlas-based connectivity analysis, vary from quantifying neurodevelopmental progress to analyzing population differences in groups of neonates. ABA can also be applied to detect pathology related to prematurity at birth or exposure to toxic substances. Future directions for this method include research designed to increase the accuracy of the image parcellation. Methods such as multi-atlas label fusion and multi-modal analysis applied to neonatal DTI currently comprise an active field of research. Moreover, ABA can be used in high-throughput analysis to efficiently process medical images and to assess longitudinal brain changes. Nevertheless, the overarching goal of neonatal ABA is application to the clinical setting, to assist with diagnoses, monitor disease progression, and outcome prediction.
- 26 October 2015
- Published by Frontiers Media SA in Frontiers in Neuroanatomy
- Vol. 9, 138
Open AccessConstruction and application of human neonatal DTI atlases
Atlas-based analysis is one of many analytical methods and is used to investigate typical as well as abnormal neurodevelopment. It has been widely applied to the adult and pediatric populations. Successful applications of atlas-based analysis (ABA) in those cohorts have motivated the creation of a neonatal atlas and parcellation map. The purpose of this review is to discuss the various neonatal diffusion tensor imaging (DTI) atlases that are available for use in ABA, examine how such atlases are constructed, review their applications, and observe future directions in DTI. Neonatal DTI atlases are created from a template, which can be study-specific or standardized, and merged with the corresponding parcellation map. Study-specific templates can retain higher image registration accuracy, but are usually not applicable across different studies. However, standardized templates can be used to make comparisons among various studies, but may not accurately reflect the anatomies of the study population. Methods such as volume-based template estimation are being developed to overcome these limitations. The applications for ABA, including atlas-based image quantification and atlas-based connectivity analysis, vary from quantifying neurodevelopmental progress to analyzing population differences in groups of neonates. ABA can also be applied to detect pathology related to prematurity at birth or exposure to toxic substances. Future directions for this method include research designed to increase the accuracy of the image parcellation. Methods such as multi-atlas label fusion and multi-modal analysis applied to neonatal DTI currently comprise an active field of research. Moreover, ABA can be used in high-throughput analysis to efficiently process medical images and to assess longitudinal brain changes. Nevertheless, the overarching goal of neonatal ABA is application to the clinical setting, to assist with diagnoses, monitor disease progression, and outcome prediction.
- Open Access
- 17 September 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (9) , e0137918
A Modeling Insight into Adipose-Derived Stem Cell Myogenesis
Adipose-derived stem cells (ASCs) are clinically important in regenerative medicine as they are relatively easy to obtain, are characterized by low morbidity, and can differentiate into myogenic progenitor cells. Although studies have elucidated the principal markers, PAX7, Desmin, MyoD, and MHC, the underlying mechanisms are not completely understood. This motivates the application of computational methods to facilitate greater understanding of such processes. In the following, we present a multi-stage kinetic model comprising a system of ordinary differential equations (ODEs). We sought to model ASC differentiation using data from a static culture, where no strain is applied, and a dynamic culture, where 10% strain is applied. The coefficients of the equations have been modulated by those experimental data points. To correctly represent the trajectories, various switches and a feedback factor based on total cell number have been introduced to better represent the biology of ASC differentiation. Furthermore, the model has then been applied to predict ASC fate for strains different from those used in the experimental conditions and for times longer than the duration of the experiment. Analysis of the results reveals unique characteristics of ASC myogenesis under dynamic conditions of the applied strain.
- 17 September 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (9) , e0137918
Open AccessA Modeling Insight into Adipose-Derived Stem Cell Myogenesis
Adipose-derived stem cells (ASCs) are clinically important in regenerative medicine as they are relatively easy to obtain, are characterized by low morbidity, and can differentiate into myogenic progenitor cells. Although studies have elucidated the principal markers, PAX7, Desmin, MyoD, and MHC, the underlying mechanisms are not completely understood. This motivates the application of computational methods to facilitate greater understanding of such processes. In the following, we present a multi-stage kinetic model comprising a system of ordinary differential equations (ODEs). We sought to model ASC differentiation using data from a static culture, where no strain is applied, and a dynamic culture, where 10% strain is applied. The coefficients of the equations have been modulated by those experimental data points. To correctly represent the trajectories, various switches and a feedback factor based on total cell number have been introduced to better represent the biology of ASC differentiation. Furthermore, the model has then been applied to predict ASC fate for strains different from those used in the experimental conditions and for times longer than the duration of the experiment. Analysis of the results reveals unique characteristics of ASC myogenesis under dynamic conditions of the applied strain.