FOFarid H. Omoumi

Farid H. Omoumi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Farid H. Omoumi has a total of 35 co-authors. Here are the top co-authors by number of shared publications:

  • Hong Liu

    Advanced Medical Imaging Center and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019, USA

    6 shared publications
  • Yuhua Li

    Advanced Medical Imaging Center and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019, USA

    5 shared publications
  • Bin Zheng

    School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK, 73019, USA

    4 shared publications
  • Bin Zheng

    Advanced Medical Imaging Center and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019, USA

    3 shared publications
  • Di Wu

    The Univ. of Oklahoma (United States)

    3 shared publications
  • Hong Liu

    The Univ. of Oklahoma (United States)

    3 shared publications

Latest Publications

  • A Pilot Study to Assess the Performance of Phase-Sensitive Breast Tomosynthesis

    by Laurie L. Fajardo, Stephen L. Hillis, Bin Zheng, Molly Donovan Wong, Muhammad U. Ghani, Farid H. Omoumi, Yuhua Li, Peter Jenkins, Michael E. Peterson, Xizeng Wu, et al.

    In this pilot study for an inline phase-sensitive breast tomosynthesis (PBT) system, the true diagnostic performance of PBT was within 0.08 of the true diagnostic performance of standard digital br... Background A new modality, phase-sensitive breast tomosynthesis (PBT), may have similar diagnostic performance to conventional breast tomosynthesis but with a reduced radiation dose. Purpose To per...


  • A phase sensitive x-ray breast tomosynthesis system: Preliminary patient images with cancer lesions

    by Muhammad U Ghani, Laurie L Fajardo, Farid Omoumi, Aimin Yan, Peter Jenkins, Molly Wong, Yuhua Li, Michael E. Peterson, Edward J Callahan, Stephen L Hillis, et al.

    Phase-sensitive x-ray imaging continues to attract research for its ability to visualize weakly absorbing details like those often encountered in biology and medicine. We have developed and assembled the first inline-based high-energy phase sensitive breast tomosynthesis (PBT) system, which is currently undergoing patient imaging testing at a clinical site. The PBT system consists of a microfocus polychromatic x-ray source and a direct conversion-based flat panel detector coated with a 1 mm thick amorphous selenium layer allowing a high detective quantum efficiency at high energies. The PBT system scans a compressed breast over 15° with 9 angular projection views. The high-energy scan parameters are carefully selected to ensure similar or lower mean glandular dose levels to the clinical standard of care systems. Phase retrieval and data binning are applied to the phase contrast angular projection views and a filtered back-projection algorithm is used to reconstruct the final images. This article reports the distributions of radiation dose versus thickness of the compressed breasts at 59 and 89 kV and sample PBT images acquired from 3 patients. Preliminary PBT images demonstrate the feasibility of this new imaging modality to acquire breast images at lower radiation dose as compared to the clinical digital breast tomosynthesis system with enhanced lesion characteristics (i.e. lesion spiculation and margins).


  • Open Access

    Mathematical estimation of half‐value layer thicknesses

    by Farid H. Omoumi, Xizeng Wu, Muhammad U. Ghani, Molly D. Wong, Yuhua Li, Hong Liu

    Objective The objective of this article is to introduce a simplified and swift method to satisfactorily estimate the half-value layers (HVL), quarter-value layer (QVL), and tenth-value layer (TVL) from the x-ray spectra emitted by any diagnostic radiology or kV radiotherapy x-ray tubes. Methods A CdTe x-ray and Gamma detector (X-123 CdTe, AmpTek Inc.) is used to measure the x-ray spectra at four different x-ray energies (low, mid, high energy x-rays) with different external filtering. The software “SpekCalc GUI” (Developed in McGill University, Montreal, Canada) is also used to obtain the simulated x-ray spectra. Both measured and simulated spectra are used to compute the HVL thicknesses of Aluminum by a mathematical method presented in this article. Next, the HVL thicknesses for corresponding tube potentials are also measured by calibrated ionization chamber and varying thicknesses of aluminum plates. Finally, the computed and measured HVL, QVL, and TVL thicknesses are compared to evaluate the efficacy of the presented method. Results The results show acceptable concordance between computed and measured quantities. The disagreement rates between measured HVL and the values derived mathematically from the x-ray spectra are 10 to 90 micrometers of Aluminum at tube potentials of 31 kV to 120 kV. As it is shown, a negligible discrepancy is observed between the analytical estimation and the experimental assessments. Conclusion The HVL is an essential component in the evaluation of the quality of an x-ray beam. However, its measurement could occasionally be challenging, time-consuming, or uncertain due to some technical difficulties. Although the scope of this study is not to undermine the value of conventional and widely accepted practice to determine the HVL thickness, the introduced method provides the fast, more convenient, and comparably reliable technique to estimate the HVL, QVL, and TVL by employing the given x-ray spectrum.


  • Objective characterization of an in-line phase sensitive imaging prototype using a mid-energy beam

    by Bradley Gregory, Muhammad Ghani, Farid Omoumi, Yuhua Li, Molly Wong, Xizeng Wu, Bin Zheng, Hong Liu

    The goal of this study was to perform a characterization study for an in-line phase contrast x-ray imaging prototype with a mid-energy source. Compared to similar prototypes that use high energies, the mid-energy system offers better balancing between the attenuation and phase induced contrasts. An inline phase sensitive prototype acquired all images for this study. The prototype utilizes a microfocus x-ray tube and a flat panel detector, aligned on an optical rail. The source-to-object distance (SOD) was set to 68.58cm while the source-to-image distance (SID) was set to 150.876cm for a magnification of ???? = 2.2. The modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) were calculated for the prototype with source potentials of 60, 90, and 120kV. The oversampled MTF was calculated for each setting. NPS experiments were conducted with a virtual detector set at the SOD. Exposure at the SID was approximately the same for all NPS experiments. The 90 and 120kVp beams were directed through a 2.5mm Al filter, while 60kVp beams were sent through a 1.2mm Al filter. Results indicate that 60kV imaging yields lower amplitude noise than high energy imaging, while maintaining the same resolving power. The cutoff frequency for each source potential was approximately 14 line pairs per mm (lp/mm). The DQE(0) for 60kV, 90kV, and 120kV were 0.757, 0.564, and 0.571 respectively. The study confirmed the hypothesis that 60kVp phase sensitive x-ray imaging yields a higher DQE than those found at 90 and 120kVp.

  • Open Access

    Impact of a single distance phase retrieval algorithm on spatial resolution in X-ray inline phase sensitive imaging

    by Muhammad U. Ghani, Bradley Gregory, Farid Omoumi, Bin Zheng, Aimin Yan, Xizeng Wu, Hong Liu

    A single-projection based phase retrieval method based on the phase attenuation duality principle (PAD) was used to compare the spatial resolution of the acquired phase sensitive and PAD processed phase retrieved images. An inline phase sensitive prototype was used to acquire the phase sensitive images. The prototype incorporates a micro-focus x-ray source and a flat panel detector with a 50 μ m pixel pitch. A phantom composed of a 2 cm thick 50–50 adipose-glandular mimicking slab sandwiched with a 0.82 cm thick slanted PMMA sharp edge was used. Phase sensitive image of the phantom was acquired at 120 kV, 3.35 mAs with a 16 μ m tube focal spot size under a geometric magnification (M) of 2.5. The PAD based method was applied to the acquired phase sensitive image for the retrieval of phase values. With necessary data processing, modulation transfer function (MTF) curves were determined for the estimation and comparison of the spatial resolution. The PAD processed phase retrieved values of the phantom were in good agreement with the theoretically calculated values. Phase sensitive images showed higher spatial resolution at all spatial frequencies compared to the phase retrieved images. It was noted that the high-frequency signal components in the retrieved image were suppressed that resulted in lower MTF values. When compared to the phase sensitive image, the cutoff resolution (10% MTF) for phase retrieved image dropped 32% from 15.6 lp/mm (32 μ m) to 10.6 lp/mm (47 μ m). The resolution offered by this phase sensitive prototype is radiographically enough to detect breast cancer.


  • Laboratory designs and validations of a glandularity-adjustable dual-purpose breast tissue phantom

    by Di Wu, Yong Chen, Farid Omoumi, Yuran Guo, Yuhua Li, Bin Zheng, Hong Liu

    The objectives of this study were to develop and evaluate a breast tissue equivalent phantom that can be used for dual purposes, conventional x-ray imaging and ultrasonography. This phantom was designed based on the prototype of an intralipid-gel soft tissue mimicking phantom used for laser photothermal therapy. The glandularities and the densities of the phantom can be adjusted by modifying the ratio of intralipid and other ingredients and adding fiber powders. An adipose tissue phantom and a glandular tissue phantom were firstly developed and phantoms of different glandularities were further developed through mixing different weight proportions of adipose and glandular. To validate the properties of the phantom for the applications of x-ray imaging techniques, three methods were employed: (1) the compositions of the elements contained in the phantoms were estimated through calculations; (2) the x-ray mass attenuation coefficients of the phantom were calculated based on the elemental compositions; (3) the x-ray photon energies deposit in the phantoms with different glandularities were simulated using Geant4 Simulation Tool Kit. The results showed high agreements with the real breast tissues at corresponding breast glandularities. For the application in ultrasonography, the elasticity of the phantom was determined by measuring the value of Young’s modulus and the value of 39 ± 10 kPa indicated the satisfactory of the requirement of being used as phantom for ultrasound imaging. Therefore, the phantoms developed in this study potentially provided a solution of dualpurpose breast tissue mimicking phantom in the needs of different level of glandularity.

  • Detectability comparison of simulated tumors in digital breast tomosynthesis using high-energy X-ray inline phase sensitive and commercial imaging systems

    by Muhammad U. Ghani, Molly D. Wong, Farid H. Omoumi, Bin Zheng, Laurie L. Fajardo, Aimin Yan, Xizeng Wu, Hong Liu


  • Potential of phase contrast x-ray imaging for detecting tumors in dense breast: initial phantom studies

    by Farid H. Omoumi, Di Wu, Yuran Guo, Muhammad U. Ghani, Yuhua Li, Kari E. Boyce, Hong Liu

    The objective of this study is to demonstrate the potential of using the High-energy in-line phase contrast x-ray imaging to detect lesions that are indistinguishable by conventional x-ray mammography but are detectable by supplemental ultrasound screening within dense breasts. For this study, a custom-made prototype x-ray/ultrasound dualmodality phantom that mimics dense breast is created to include embedded carbon fiber disks with multiple diameters and thicknesses. The phase contrast image is acquired using a prototype at 120kVp, 67μA, exposure time of 16.7sec and focal spot size of 18.3μm with average glandular dose (AGD) of 0.3mGy under a geometric magnification of 2.48. The conventional x-ray image is acquired with a bench top system operating at 40kVp, 300μA, exposure time of 50sec and same AGD. The results demonstrate that conventional x-ray imaging is unable to detect any of the carbon fiber disks, while phase contrast imaging and ultrasonography are able to detect most or all of the disks under the applied experimental conditions. These results illustrate phase contrast imaging is capable of detecting targets in a dual-modality phantom which simulates lesions in dense breast tissue, when the simulated lesions are not distinguishable by conventional mammography. Therefore mammographic screening with phase contrast technique could eventually replace both x-ray and ultrasonography for screening detection of small lesions with microcalcification in dense breasts where pathologic lesions are masked due to highly glandular tissue. These results encourage further investigation using high glandular density phantoms to further evaluate the effectiveness of phase contrast imaging as a single modality test, which combines the advantages of both x-ray and ultrasound imaging in cancer screening of patients with dense breasts.


  • Conventional and phase contrast x-ray imaging techniques and ultrasound imaging method in breast tumor detection: initial comparison studies using phantom

    by Farid H. Omoumi, Molly Donovan Wong, Yuran Guo, Di Wu, Yuhua Li, Muhammad U. Ghani, Bin Zheng, Hong Liu

    The objective of this study was to demonstrate the capability of the high-energy in-line phase contrast imaging in detecting the breast tumors which are undetectable by conventional x-ray imaging but detectable by ultrasound. Experimentally, a CIRS multipurpose breast phantom with heterogeneous 50% glandular and 50% adipose breast tissue was imaged by high-energy in-line phase contrast system, conventional x-ray system and ultrasonography machine. The high-energy in-line phase contrast projection was acquired at 120 kVp, 0.3 mAs with the focal spot size of 18.3 μm. The conventional x-ray projection was acquired at 40 kVp, 3.3 mAs with the focal spot size of 22.26 μm. Both of the x-ray imaging acquisitions were conducted with a unique mean glandular dose of 0.08 mGy. As the result, the high-energy in-line phase contrast system was able to detect one lesion-like object which was also detected by the ultrasonography. This object was spherical shape with the length of about 12.28 mm. Also, the conventional x-ray system was not able to detect any objects. This result indicated the advantages provided by high-energy in-line phase contrast over conventional x-ray system in detecting lesion-like object under the same radiation dose. To meet the needs of current clinical strategies for high-density breasts screening, breast phantoms with higher glandular densities will be employed in future studies.