Ratana Chhun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ratana Chhun has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Pierre Touboul
DPHY, ONERA, Université Paris Saclay, F-92322 Châtillon, France
6 shared publicationsBernard Foulon
DPHY, ONERA, Université Paris Saclay, F-92322 Châtillon, France
5 shared publications- Manuel Rodrigues
DPHY, ONERA, Université Paris Saclay, F-92322 Châtillon, France
5 shared publications P. Touboul
ONERA, Physics and Instrumentation Department, BP 72 – 29 avenue de la Division Leclerc, FR-92322 Châtillon Cedex, France
5 shared publicationsVincent Lebat
DPHY, ONERA, Université Paris Saclay, F-92322 Châtillon, France
5 shared publicationsAlain Robert
CNES, 18 Avenue E Belin, F-31401 Toulouse, France
4 shared publications
Latest Publications
- 14 September 2022
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 39 (20) , 204005
Microscope instrument in-flight characterization
Since the MICROSCOPE instrument aims to measure accelerations as low as a few 10−15 m s−2 and cannot operate on ground, it was necessary to have a large time dedicated to its characterization in flight. After its release and first operation, the characterization experiments covered all the aspects of the instrument design in order to consolidate the scientific measurements and the subsequent conclusions drawn from them. Over the course of the mission we validated the servo-control and even updated the PID control laws for each inertial sensor. Thanks to several dedicated experiments and the analysis of the instrument sensitivities, we have been able to identify a number of instrument characteristics such as biases, gold wire and electrostatic stiffnesses, non linearities, couplings and free motion ranges of the test-masses, which may first impact the scientific objective and secondly the analysis of the instrument good operation.
- 14 September 2022
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 39 (20) , 204005
Microscope instrument in-flight characterization
Since the MICROSCOPE instrument aims to measure accelerations as low as a few 10−15 m s−2 and cannot operate on ground, it was necessary to have a large time dedicated to its characterization in flight. After its release and first operation, the characterization experiments covered all the aspects of the instrument design in order to consolidate the scientific measurements and the subsequent conclusions drawn from them. Over the course of the mission we validated the servo-control and even updated the PID control laws for each inertial sensor. Thanks to several dedicated experiments and the analysis of the instrument sensitivities, we have been able to identify a number of instrument characteristics such as biases, gold wire and electrostatic stiffnesses, non linearities, couplings and free motion ranges of the test-masses, which may first impact the scientific objective and secondly the analysis of the instrument good operation.
- Open Access
- 7 September 2022
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 39 (20) , 204006
MICROSCOPE: systematic errors
The MICROSCOPE mission aims to test the weak equivalence principle (WEP) in orbit with an unprecedented precision of 10−15 on the Eötvös parameter thanks to electrostatic accelerometers on board a drag-free micro-satellite. The precision of the test is determined by statistical errors, due to the environment and instrument noises, and by systematic errors to which this paper is devoted. Systematic error sources can be divided into three categories: external perturbations, such as the residual atmospheric drag or the gravity gradient at the satellite altitude, perturbations linked to the satellite design, such as thermal or magnetic perturbations, and perturbations from the instrument internal sources. Each systematic error is evaluated or bounded in order to set a reliable upper bound on the WEP parameter estimation uncertainty.
- 7 September 2022
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 39 (20) , 204006
Open AccessMICROSCOPE: systematic errors
The MICROSCOPE mission aims to test the weak equivalence principle (WEP) in orbit with an unprecedented precision of 10−15 on the Eötvös parameter thanks to electrostatic accelerometers on board a drag-free micro-satellite. The precision of the test is determined by statistical errors, due to the environment and instrument noises, and by systematic errors to which this paper is devoted. Systematic error sources can be divided into three categories: external perturbations, such as the residual atmospheric drag or the gravity gradient at the satellite altitude, perturbations linked to the satellite design, such as thermal or magnetic perturbations, and perturbations from the instrument internal sources. Each systematic error is evaluated or bounded in order to set a reliable upper bound on the WEP parameter estimation uncertainty.
- Open Access
MICROSCOPE instrument in-flight characterization
Since the MICROSCOPE instrument aims to measure accelerations as low as a few 10$^{-15}$\,m\,s$^{-2}$ and cannot operate on ground, it was obvious to have a large time dedicated to its characterization in flight. After its release and first operation, the characterization experiments covered all the aspects of the instrument design in order to consolidate the scientific measurements and the subsequent conclusions drawn from them. Over the course of the mission we validated the servo-control and even updated the PID control laws for each inertial sensor. Thanks to several dedicated experiments and the analysis of the instrument sensitivities, we have been able to identify a number of instrument characteristics such as biases, gold wire and electrostatic stiffnesses, non linearities, couplings and free motion ranges of the test-masses, which may first impact the scientific objective and secondly the analysis of the instrument good operation.
Open AccessMICROSCOPE instrument in-flight characterization
Since the MICROSCOPE instrument aims to measure accelerations as low as a few 10$^{-15}$\,m\,s$^{-2}$ and cannot operate on ground, it was obvious to have a large time dedicated to its characterization in flight. After its release and first operation, the characterization experiments covered all the aspects of the instrument design in order to consolidate the scientific measurements and the subsequent conclusions drawn from them. Over the course of the mission we validated the servo-control and even updated the PID control laws for each inertial sensor. Thanks to several dedicated experiments and the analysis of the instrument sensitivities, we have been able to identify a number of instrument characteristics such as biases, gold wire and electrostatic stiffnesses, non linearities, couplings and free motion ranges of the test-masses, which may first impact the scientific objective and secondly the analysis of the instrument good operation.
- Top Cited Papers
- 4 December 2017
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 119 (23) , 231101
MICROSCOPE Mission: First Results of a Space Test of the Equivalence Principle
According to the weak equivalence principle, all bodies should fall at the same rate in a gravitational field. The MICROSCOPE satellite, launched in April 2016, aims to test its validity at the precision level, by measuring the force required to maintain two test masses (of titanium and platinum alloys) exactly in the same orbit. A nonvanishing result would correspond to a violation of the equivalence principle, or to the discovery of a new long-range force. Analysis of the first data gives ( statistical uncertainty) for the titanium-platinum Eötvös parameter characterizing the relative difference in their free-fall accelerations.- 4 December 2017
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 119 (23) , 231101
Top Cited PapersMICROSCOPE Mission: First Results of a Space Test of the Equivalence Principle
According to the weak equivalence principle, all bodies should fall at the same rate in a gravitational field. The MICROSCOPE satellite, launched in April 2016, aims to test its validity at the precision level, by measuring the force required to maintain two test masses (of titanium and platinum alloys) exactly in the same orbit. A nonvanishing result would correspond to a violation of the equivalence principle, or to the discovery of a new long-range force. Analysis of the first data gives ( statistical uncertainty) for the titanium-platinum Eötvös parameter characterizing the relative difference in their free-fall accelerations. - 1 February 2012
- Published by World Scientific Pub Co Pte Ltd
- p. 1552-1554
DEVELOPMENT STATUS OF THE PAYLOAD FOR THE MICROSCOPE MISSION
- 1 February 2012
- Published by World Scientific Pub Co Pte Ltd
- p. 1552-1554
DEVELOPMENT STATUS OF THE PAYLOAD FOR THE MICROSCOPE MISSION
- 1 April 2009
- Published by Cambridge University Press (CUP) in Proceedings of the International Astronomical Union
- Vol. 5 (S261) , 402-408
Two cylindrical masses in orbit for the test of the equivalence principle
Two pairs of solid test-masses have been considered to perform in space the test of the universality of free fall with an accuracy of at least 10−15. These cylindrical masses are precisely at the heart of the MICROSCOPE mission instrument comprising two differential electrostatic accelerometers. These masses shall exhibit material quality, shapes, positions and alignments in regard to stringent experimental requirements. Indeed the space experiment is based on the control of the two masses submitted to the same gravity acceleration along the same orbit at 810 km altitude with an accuracy of 10−11 m. Thus effects of Earth and satellite gravity gradients shall be contained as well as any other disturbances of the mass motions induced by their magnetic susceptibility or electrical dissymmetries, by outgassing of the materials or radiation emissivity. Furthermore, the electrostatic levitation of the two masses depends dramatically on the mass shapes and electrical properties in particular for the definition of the sensitive axes orientation. All these aspects will be presented from the mass characteristics to the space MICROSCOPE experiment performance.
- 1 April 2009
- Published by Cambridge University Press (CUP) in Proceedings of the International Astronomical Union
- Vol. 5 (S261) , 402-408
Two cylindrical masses in orbit for the test of the equivalence principle
Two pairs of solid test-masses have been considered to perform in space the test of the universality of free fall with an accuracy of at least 10−15. These cylindrical masses are precisely at the heart of the MICROSCOPE mission instrument comprising two differential electrostatic accelerometers. These masses shall exhibit material quality, shapes, positions and alignments in regard to stringent experimental requirements. Indeed the space experiment is based on the control of the two masses submitted to the same gravity acceleration along the same orbit at 810 km altitude with an accuracy of 10−11 m. Thus effects of Earth and satellite gravity gradients shall be contained as well as any other disturbances of the mass motions induced by their magnetic susceptibility or electrical dissymmetries, by outgassing of the materials or radiation emissivity. Furthermore, the electrostatic levitation of the two masses depends dramatically on the mass shapes and electrical properties in particular for the definition of the sensitive axes orientation. All these aspects will be presented from the mass characteristics to the space MICROSCOPE experiment performance.
- 1 May 2007
- Published by Elsevier in Acta Astronautica
- Vol. 60 (10-11) , 873-879
Equivalence principle test with microscope: Laboratory and engineering models preliminary results for evaluation of performance
- 1 May 2007
- Published by Elsevier in Acta Astronautica
- Vol. 60 (10-11) , 873-879
Equivalence principle test with microscope: Laboratory and engineering models preliminary results for evaluation of performance
- 1 January 2007
- Published by Elsevier in Advances In Space Research
- Vol. 39 (2) , 307-314
Development status of the differential accelerometer for the MICROSCOPE mission
- 1 January 2007
- Published by Elsevier in Advances In Space Research
- Vol. 39 (2) , 307-314
Development status of the differential accelerometer for the MICROSCOPE mission
- 31 October 2005
- Published by Elsevier in Acta Astronautica
- Vol. 57 (2-8) , 341-347
Development of a differential accelerometer to test the equivalence principle in the microscope mission
- 31 October 2005
- Published by Elsevier in Acta Astronautica
- Vol. 57 (2-8) , 341-347
Development of a differential accelerometer to test the equivalence principle in the microscope mission