Fabio Ecke Bisogno
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fabio Ecke Bisogno has a total of 137 co-authors. Here are the top co-authors by number of shared publications:
- Alysson Raniere Seidel
Industrial Technical School of Santa Maria
29 shared publications Do Prado
13 shared publicationsM. F. da Silva
Federal University of Santa Maria - UFSM, Electrical and Computational Systems Research and Development Group - GSEC, Group of Intelligence in Lighting - GEDRE, Santa Maria, RS, Brazil
11 shared publications- Maikel Fernando Menke
Federal University of Santa Maria - UFSM, Electrical and Computational Systems Research and Development Group - GSEC, Group of Intelligence in Lighting - GEDRE, RS, Brazil
11 shared publications - Jose Marcos Alonso
Department of Electrical Engineering, University of Oviedo, Asturias, Spain
9 shared publications - Lucas Sangoi Mendonca
Federal University of Technology - Paraná image/svg+xml
7 shared publications
Latest Publications
- Open Access
- 13 July 2026
- Published by Elsevier in Control Engineering Practice
- Vol. 176
Model reference adaptive control with multiple resonant controllers and active damping for grid-connected inverters with LCL filter under distorted grid conditions
- 13 July 2026
- Published by Elsevier in Control Engineering Practice
- Vol. 176
Open AccessModel reference adaptive control with multiple resonant controllers and active damping for grid-connected inverters with LCL filter under distorted grid conditions
- Open Access
- 30 January 2026
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 31, e202610
Analysis and design of a load-independent class-E LCL resonant converter
This work brings in a load-independent Class-E LCL resonant converter. The intertwined soft-switching and load-independent functions in resonant topologies require high mathematical effort and leads to trade-off designing characteristics related to the operating frequency, output power and load range. Therefore, this paper shows the exact analysis for the Class-E LCL converter by axiomatically dealing with the second, third and fourth-order polynomials. In addition, a design method is proposed based on the implicit equations while considering the soft-switching and load-independence features. The measured built prototype operates at 1.2 MHz, which outperforms most of the state-of-the-art compared converters by x 1.2, while maintaining comparable output power and efficiency (92 %).
- 30 January 2026
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 31, e202610
Open AccessAnalysis and design of a load-independent class-E LCL resonant converter
This work brings in a load-independent Class-E LCL resonant converter. The intertwined soft-switching and load-independent functions in resonant topologies require high mathematical effort and leads to trade-off designing characteristics related to the operating frequency, output power and load range. Therefore, this paper shows the exact analysis for the Class-E LCL converter by axiomatically dealing with the second, third and fourth-order polynomials. In addition, a design method is proposed based on the implicit equations while considering the soft-switching and load-independence features. The measured built prototype operates at 1.2 MHz, which outperforms most of the state-of-the-art compared converters by x 1.2, while maintaining comparable output power and efficiency (92 %).
- Open Access
- 7 January 2026
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 31, e202602
Modeling and Control of a Full-Bridge DC-DC Converter for Arc Welding Applications
This study presents the modeling and control of a full-bridge DC-DC converter applied to Gas Metal Arc Welding (GMAW) in short-circuit transfer mode. GMAW is widely used in industrial manufacturing due to its versatility. However, achieving stable operation in short-circuit transfer requires precise regulation of the welding current and arc voltage. To address this challenge, a simplified yet representative model of the converter and load dynamics is developed. Based on this model, a dual-loop digital control strategy is implemented to ensure fast transient response, reference tracking, and improved stability of the welding process. The effectiveness of the proposed approach is experimentally validated on an industrial-grade prototype, demonstrating agreement between theoretical predictions and measured waveforms.
- 7 January 2026
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 31, e202602
Open AccessModeling and Control of a Full-Bridge DC-DC Converter for Arc Welding Applications
This study presents the modeling and control of a full-bridge DC-DC converter applied to Gas Metal Arc Welding (GMAW) in short-circuit transfer mode. GMAW is widely used in industrial manufacturing due to its versatility. However, achieving stable operation in short-circuit transfer requires precise regulation of the welding current and arc voltage. To address this challenge, a simplified yet representative model of the converter and load dynamics is developed. Based on this model, a dual-loop digital control strategy is implemented to ensure fast transient response, reference tracking, and improved stability of the welding process. The effectiveness of the proposed approach is experimentally validated on an industrial-grade prototype, demonstrating agreement between theoretical predictions and measured waveforms.
- Open Access
- 18 June 2024
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 29
Generalized Average Model of the Class-E2 DC-DC Resonant converter
In this paper, the generalized average model of the Class-E$^2$ DC-DC resonant converter has been introduced. The standard average model is not interesting in resonant converters due to their large waveform oscillations. In addition, steady-state approaches restrain the converter to hysteresis control. The resonant tank voltage, reconstructed by the fundamental component, as performed in LLC converters by extended describing function, is not suitable for the Class-E$^2$ topology because the inverter/rectifier interface voltage requires, at least, the third-order harmonic usage. This work relies on the generalized average method to perform the large-signal and small-signal models of the Class-E$^2$ converter. This paper shows how to systematically deal with the following modeling issues: negative index from the convolution summation, complex numbers from the Fourier coefficients and high number of state-space variables. The theoretical approach is confirmed by measurement in an assembled 800 kHz Class-E$^2$ converter based on voltage-controlled oscillator.
- 18 June 2024
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 29
Open AccessGeneralized Average Model of the Class-E2 DC-DC Resonant converter
In this paper, the generalized average model of the Class-E$^2$ DC-DC resonant converter has been introduced. The standard average model is not interesting in resonant converters due to their large waveform oscillations. In addition, steady-state approaches restrain the converter to hysteresis control. The resonant tank voltage, reconstructed by the fundamental component, as performed in LLC converters by extended describing function, is not suitable for the Class-E$^2$ topology because the inverter/rectifier interface voltage requires, at least, the third-order harmonic usage. This work relies on the generalized average method to perform the large-signal and small-signal models of the Class-E$^2$ converter. This paper shows how to systematically deal with the following modeling issues: negative index from the convolution summation, complex numbers from the Fourier coefficients and high number of state-space variables. The theoretical approach is confirmed by measurement in an assembled 800 kHz Class-E$^2$ converter based on voltage-controlled oscillator.
- 27 November 2023
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 71 (12) , 1040-1050
DC voltage ancillary controller for dynamic security of shunt-compensated microgrids
Modern power systems require special features from the distributed energy resources especially to meet the power quality and dynamic security. The distribution static synchronous compensator (DSTATCOM) has a safe DC voltage operating range that is often unexplored. Self-excited induction generators (SEIGs) with a shunt DSTATCOM is a well-known solution for low-power, low-cost generation. These systems may have poor robustness against surges and contingencies. This paper proposes an ancillary controller as a supplement in the shunt compensation of an off-grid distributed generation system powered by SEIGs. The controller consists of a variable structure that uses an adequate DC bus capacitor voltage range to provide fast frequency response (FFR) with soft recovery. The control performance for fault rejection is evaluated as well as for load disturbances and generation contingency. Simulation results are presented to demonstrate system operation and compensator performance.
- 27 November 2023
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 71 (12) , 1040-1050
DC voltage ancillary controller for dynamic security of shunt-compensated microgrids
Modern power systems require special features from the distributed energy resources especially to meet the power quality and dynamic security. The distribution static synchronous compensator (DSTATCOM) has a safe DC voltage operating range that is often unexplored. Self-excited induction generators (SEIGs) with a shunt DSTATCOM is a well-known solution for low-power, low-cost generation. These systems may have poor robustness against surges and contingencies. This paper proposes an ancillary controller as a supplement in the shunt compensation of an off-grid distributed generation system powered by SEIGs. The controller consists of a variable structure that uses an adequate DC bus capacitor voltage range to provide fast frequency response (FFR) with soft recovery. The control performance for fault rejection is evaluated as well as for load disturbances and generation contingency. Simulation results are presented to demonstrate system operation and compensator performance.
- 7 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Single Switch High Step-Up Soft-Switching Boost Converter with Coupled Inductor
In this paper, a soft-switching boost converter with coupled inductor and a resonant tank is proposed. From this, the switching frequency can be increased without compromising the efficiency of the converter, and consequently the volume, the size and the cost of the components will decrease. To demonstrate the advantage and validate the theoretical evaluation of the proposed converter, such as; simplicity of operation, low components count, single switch, low voltage stress across the components. In this digest, simulation results of $V_{i}=37.4\mathrm{V}, V_{o}=400\mathrm{V}$ and $f_{s}=100\text{kHz}$ are presented.- 7 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Single Switch High Step-Up Soft-Switching Boost Converter with Coupled Inductor
In this paper, a soft-switching boost converter with coupled inductor and a resonant tank is proposed. From this, the switching frequency can be increased without compromising the efficiency of the converter, and consequently the volume, the size and the cost of the components will decrease. To demonstrate the advantage and validate the theoretical evaluation of the proposed converter, such as; simplicity of operation, low components count, single switch, low voltage stress across the components. In this digest, simulation results of $V_{i}=37.4\mathrm{V}, V_{o}=400\mathrm{V}$ and $f_{s}=100\text{kHz}$ are presented.- 26 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (3) , 3170-3181
A Control Actuation Concept for Self-Oscillating Resonant Converters
This article presents a concept of controller actuation mechanism for self-oscillating resonant converters (SORCs). Simplicity, robustness, and cost-effectiveness are among the main features of this type of converter. Described as a self-oscillating system with an intrinsic positive-type feedback switching network, also known as the self-oscillating command circuit (SOCC), it performs its own gate drive with self-sustained frequency, designed around an equilibrium point. Designers often disregard this converter as an explicit solution for closed-loop applications, especially those that require extra layers of control, due to its inherent inability to operate under pulse frequency modulation without extra circuitry. Thus, in this article, a robust, efficient, and simple way of controlling the SORC through frequency modulation is proposed. The idea consists of varying the self-oscillating frequency through the equivalent magnetizing inductance of the SOCC, using a mechanism called variable current transformer. Thus, through the injection of a small controllable dc current, it is possible to modulate the frequency of resonant converters. This allows the self-oscillating system to follow a reference current signal, operating in closed-loop over a wide range of input voltage and load variation.
- 26 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (3) , 3170-3181
A Control Actuation Concept for Self-Oscillating Resonant Converters
This article presents a concept of controller actuation mechanism for self-oscillating resonant converters (SORCs). Simplicity, robustness, and cost-effectiveness are among the main features of this type of converter. Described as a self-oscillating system with an intrinsic positive-type feedback switching network, also known as the self-oscillating command circuit (SOCC), it performs its own gate drive with self-sustained frequency, designed around an equilibrium point. Designers often disregard this converter as an explicit solution for closed-loop applications, especially those that require extra layers of control, due to its inherent inability to operate under pulse frequency modulation without extra circuitry. Thus, in this article, a robust, efficient, and simple way of controlling the SORC through frequency modulation is proposed. The idea consists of varying the self-oscillating frequency through the equivalent magnetizing inductance of the SOCC, using a mechanism called variable current transformer. Thus, through the injection of a small controllable dc current, it is possible to modulate the frequency of resonant converters. This allows the self-oscillating system to follow a reference current signal, operating in closed-loop over a wide range of input voltage and load variation.
- 18 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (1) , 241-253
State-Space Model of an Electro-Mechanical-Acoustic Contactless Energy Transfer System Based on Multiphysics Networks
Contactless energy transfer systems are mainly divided into acoustic, inductive, capacitive, and optical, in which main applications are related to biomedical, wireless chargers, and sensors in metal enclosures. When solids are used as transfer media, ultrasound transducers based on piezoelectricity can be used for through-wall power transfer, which can be named as an electro-mechanical-acoustic contactless energy transfer system. This work presents a state-space model derived from a multiphysics network that includes all the multiphysical power conversion without separating the stages and including the real physical elements, like as the piezoelectric parameters and the geometry of the transfer media. The model is compared to the experimental response of the system and evaluated for different scenarios regarding transducers types and solid transfer media. An error analysis has shown that the maximum quadratic error between theoretical and experimental responses is 3.7%.
- 18 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (1) , 241-253
State-Space Model of an Electro-Mechanical-Acoustic Contactless Energy Transfer System Based on Multiphysics Networks
Contactless energy transfer systems are mainly divided into acoustic, inductive, capacitive, and optical, in which main applications are related to biomedical, wireless chargers, and sensors in metal enclosures. When solids are used as transfer media, ultrasound transducers based on piezoelectricity can be used for through-wall power transfer, which can be named as an electro-mechanical-acoustic contactless energy transfer system. This work presents a state-space model derived from a multiphysics network that includes all the multiphysical power conversion without separating the stages and including the real physical elements, like as the piezoelectric parameters and the geometry of the transfer media. The model is compared to the experimental response of the system and evaluated for different scenarios regarding transducers types and solid transfer media. An error analysis has shown that the maximum quadratic error between theoretical and experimental responses is 3.7%.
- 26 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (1) , 234-248
Distributed Hierarchical Control With Separation of Concerns for Parallel-Connected UPSs
This article presents a distributed hierarchical control structure for parallel uninterruptible power supplies. A dynamic approach with separation of concerns is proposed for the secondary control, where a so-called grid forming inverter is responsible for restoring the amplitude and frequency of the output voltage, while the remaining inverters, called grid supporting, are responsible for enhancing long-term power sharing. This strategy aims to minimize the tradeoff between voltage regulation and power sharing through secondary control, which uses a low bandwidth communication link. For the primary controller, resistive droop control with virtual resistance is employed to accomplish short-term power sharing. Simple design guidelines for the secondary controllers based on simplified models developed in the article are provided. Extensive experimental results obtained from two 500-VA prototypes demonstrated the good performance of the proposed strategy. The amplitude and power sharing errors remained below 1% and 2%, respectively, for the entire load range evaluated.
- 26 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (1) , 234-248
Distributed Hierarchical Control With Separation of Concerns for Parallel-Connected UPSs
This article presents a distributed hierarchical control structure for parallel uninterruptible power supplies. A dynamic approach with separation of concerns is proposed for the secondary control, where a so-called grid forming inverter is responsible for restoring the amplitude and frequency of the output voltage, while the remaining inverters, called grid supporting, are responsible for enhancing long-term power sharing. This strategy aims to minimize the tradeoff between voltage regulation and power sharing through secondary control, which uses a low bandwidth communication link. For the primary controller, resistive droop control with virtual resistance is employed to accomplish short-term power sharing. Simple design guidelines for the secondary controllers based on simplified models developed in the article are provided. Extensive experimental results obtained from two 500-VA prototypes demonstrated the good performance of the proposed strategy. The amplitude and power sharing errors remained below 1% and 2%, respectively, for the entire load range evaluated.
- Open Access
- 7 December 2020
- Published by Sociedade Brasileira de Automatica
- Vol. 2 (1)
Modelagem e Extração Paramétrica de Baterias de Chumbo-Ácido para Desenvolvimento de Conversores
Este artigo apresenta uma revisão bibliográfica sobre os principais modelos para baterias de chumbo-ácido, dando foco aos modelos de circuito equivalente. Estes podem ser utilizados em simuladores comerciais e acelerar o desenvolvimento de eletrônica de potência voltada para carga e manutenção dessas baterias, especialmente em subestações de energia. Além de uma visão geral sobre ensaios com baterias, o artigo traz um levantamento dos dados fornecidos pelos principais fabricantes nacionais de baterias e apresenta métodos de extração paramétrica baseados em dados experimentais e fornecidos no manual. São ressaltadas a relação entre estado de carga, tensão, corrente e resistência interna da bateria. Por último, simulações de curva de descarga com diferentes correntes são realizadas, validando os métodos apresentados.
- 7 December 2020
- Published by Sociedade Brasileira de Automatica
- Vol. 2 (1)
Open AccessModelagem e Extração Paramétrica de Baterias de Chumbo-Ácido para Desenvolvimento de Conversores
Este artigo apresenta uma revisão bibliográfica sobre os principais modelos para baterias de chumbo-ácido, dando foco aos modelos de circuito equivalente. Estes podem ser utilizados em simuladores comerciais e acelerar o desenvolvimento de eletrônica de potência voltada para carga e manutenção dessas baterias, especialmente em subestações de energia. Além de uma visão geral sobre ensaios com baterias, o artigo traz um levantamento dos dados fornecidos pelos principais fabricantes nacionais de baterias e apresenta métodos de extração paramétrica baseados em dados experimentais e fornecidos no manual. São ressaltadas a relação entre estado de carga, tensão, corrente e resistência interna da bateria. Por último, simulações de curva de descarga com diferentes correntes são realizadas, validando os métodos apresentados.