Francisco Jiménez-Moreno
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Francisco Jiménez-Moreno has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Ana Isabel Jiménez Abizanda
Departamento de Química Analítica, Bromatología y Toxicología, Facultad de Química, Universidad de La Laguna, E-38204 La Laguna, Tenerife, Spain
8 shared publications - Adrián Gutiérrez-Serpa
Chair of Inorganic Chemistry I, Faculty of Chemistry and Food Chemistry, Technische Universität Dresden, Bergstraße 66, Dresden 01069, Germany
4 shared publications - Verónica Pino
Instituto Universitario de Enfermedades Tropicales y Salud Pública de Canarias, Universidad de La Laguna, 38296 San Cristóbal de La Laguna, Santa Cruz de Tenerife, Spain
4 shared publications - José M. García Fraga
Departamento de Quı́mica Analı́tica, Nutrición y Bromatologı́a, Facultad de Quı́mica, Universidad de La Laguna, E-38204 La Laguna, Tenerife, Spain
3 shared publications - Jorge Pasán
MAT4LL Departamento de Química Unidad Departamental de Química Inorgánica Universidad de La Laguna La Laguna Tenerife 38206 Spain
2 shared publications A.I.JIménez Abizanda
1 shared publication
Latest Publications
- Open Access
Hybrid Materials Formed with Green Metal-Organic Frameworks and Polystyrene as Sorbents in Dispersive Micro-Solid-Phase Extraction for Determining Personal Care Products in Micellar Cosmetics
Hybrid materials based on polystyrene (PS) and green metal-organic frameworks (MOFs) were synthesized, characterized, and evaluated as potential sorbents in dispersive micro-solid-phase extraction (µ-dSPE). Among the resulting materials, the hybrid PS/DUT-67(Zr) was selected as the adequate extraction material for the monitoring of six personal care products in micellar cosmetic samples, combining the µ-dSPE method with ultra-high performance liquid chromatography (UHPLC) coupled to ultraviolet/visible detection (UV/Vis). Univariate studies and a factorial design were performed in the optimization of the microextraction procedure. The compromise optimum extraction conditions included 20 mg of PS/DUT-67(Zr) for 10 mL of sample, 2 min of extraction time, and two desorption steps using 100 µL of acetonitrile and 5 min assisted by vortex in each one. The validated μ-dSPE-UHPLC-UV/Vis method presented limits of detection and quantification down to 3.00 and 10.0 μg·L−1, respectively. The inter-day precision values were lower than 23.5 and 21.2% for concentration levels of 75 μg·L−1 and 650 μg·L−1, respectively. The hydrophobicity of the resulting PS/DUT-67(Zr) material was crucial for the improvement of its extraction capacity in comparison with its unitary components, showing the advantages of combining MOFs with other materials, getting new sorbents with interesting properties.
Open AccessHybrid Materials Formed with Green Metal-Organic Frameworks and Polystyrene as Sorbents in Dispersive Micro-Solid-Phase Extraction for Determining Personal Care Products in Micellar Cosmetics
Hybrid materials based on polystyrene (PS) and green metal-organic frameworks (MOFs) were synthesized, characterized, and evaluated as potential sorbents in dispersive micro-solid-phase extraction (µ-dSPE). Among the resulting materials, the hybrid PS/DUT-67(Zr) was selected as the adequate extraction material for the monitoring of six personal care products in micellar cosmetic samples, combining the µ-dSPE method with ultra-high performance liquid chromatography (UHPLC) coupled to ultraviolet/visible detection (UV/Vis). Univariate studies and a factorial design were performed in the optimization of the microextraction procedure. The compromise optimum extraction conditions included 20 mg of PS/DUT-67(Zr) for 10 mL of sample, 2 min of extraction time, and two desorption steps using 100 µL of acetonitrile and 5 min assisted by vortex in each one. The validated μ-dSPE-UHPLC-UV/Vis method presented limits of detection and quantification down to 3.00 and 10.0 μg·L−1, respectively. The inter-day precision values were lower than 23.5 and 21.2% for concentration levels of 75 μg·L−1 and 650 μg·L−1, respectively. The hydrophobicity of the resulting PS/DUT-67(Zr) material was crucial for the improvement of its extraction capacity in comparison with its unitary components, showing the advantages of combining MOFs with other materials, getting new sorbents with interesting properties.
- 29 April 2019
- Published by Springer Nature in Microchimica Acta
- Vol. 186 (5) , 311
Braid solid-phase microextraction of polycyclic aromatic hydrocarbons by using fibers coated with silver-based nanomaterials in combination with HPLC with fluorometric detection
Authors propose a novel braid support configuration for use in solid-phase microextraction (SPME) fibers. Two different braided supports (double and triple) were prepared and compared with the conventional single support configuration. Three kinds of silver-based nanomaterials that serve as coatings on these supports are described. They included silver dendrites, silver nanoparticles (AgNPs), and silver dendrites decorated with AgNPs (Ag-dendrites@AgNPs). They were prepared by electrodeposition, a layer-by-layer (LBL) method, and a hybrid strategy, respectively. Fibers were used in the direct-immersion (DI) mode of SPME. Five polycyclic aromatic hydrocarbons (PAHs) were studied as model analytes by DI-SPME when analyzing (spiked) underground waters. PAHs were further determined with high-performance liquid chromatography (HPLC) and fluorescence detection. The analytical performance of the fibers was compared to that of the commercial polydimethylsiloxane (PDMS) fiber of 100 μm thickness. AgNPs obtained by LBL was the best coating and the double braid was the best support configuration. The configuration of the SPME support always played an important role independently on the coating material, being always beneficial the use of double-braids. Despite the low coatings volumes of the silver-based fibers compared to that of PDMS, the analytical features of the method were adequate. Figures of merit include: (a) limits of detection down to 20 ng·L−1; (b) intra-day, inter-day, and inter-fiber precisions (expressed as RSDs) of 60 extractions).
- 29 April 2019
- Published by Springer Nature in Microchimica Acta
- Vol. 186 (5) , 311
Braid solid-phase microextraction of polycyclic aromatic hydrocarbons by using fibers coated with silver-based nanomaterials in combination with HPLC with fluorometric detection
Authors propose a novel braid support configuration for use in solid-phase microextraction (SPME) fibers. Two different braided supports (double and triple) were prepared and compared with the conventional single support configuration. Three kinds of silver-based nanomaterials that serve as coatings on these supports are described. They included silver dendrites, silver nanoparticles (AgNPs), and silver dendrites decorated with AgNPs (Ag-dendrites@AgNPs). They were prepared by electrodeposition, a layer-by-layer (LBL) method, and a hybrid strategy, respectively. Fibers were used in the direct-immersion (DI) mode of SPME. Five polycyclic aromatic hydrocarbons (PAHs) were studied as model analytes by DI-SPME when analyzing (spiked) underground waters. PAHs were further determined with high-performance liquid chromatography (HPLC) and fluorescence detection. The analytical performance of the fibers was compared to that of the commercial polydimethylsiloxane (PDMS) fiber of 100 μm thickness. AgNPs obtained by LBL was the best coating and the double braid was the best support configuration. The configuration of the SPME support always played an important role independently on the coating material, being always beneficial the use of double-braids. Despite the low coatings volumes of the silver-based fibers compared to that of PDMS, the analytical features of the method were adequate. Figures of merit include: (a) limits of detection down to 20 ng·L−1; (b) intra-day, inter-day, and inter-fiber precisions (expressed as RSDs) of 60 extractions).
- 1 October 2017
- Published by Elsevier in Journal of Luminescence
- Vol. 190, 207-214
Synthesis and physical characterization of Ag nanoparticles and their interaction with Fe
- 1 October 2017
- Published by Elsevier in Journal of Luminescence
- Vol. 190, 207-214
Synthesis and physical characterization of Ag nanoparticles and their interaction with Fe
- 6 April 2017
- Published by Wiley in Journal of Separation Science
- Vol. 40 (9) , 2009-2021
Gold nanoparticles based solid‐phase microextraction coatings for determining organochlorine pesticides in aqueous environmental samples
The use of solid‐phase microextraction coatings based on gold nanoparticles was investigated, focusing the attention on the preparation of nanoparticles with nonclassical reduction agents of HAuCl4 such as gallic acid and H2O2, rather than the conventional sodium citrate. All nanoparticles were characterized by diode array spectroscopy, whereas novel nanoparticles prepared with gallic acid and H2O2 were also characterized by microscopic techniques. Solid‐phase microextraction coatings were prepared with a layer‐by‐layer approach. Gallic acid permitted the preparation of stable nanoparticles with milder experimental conditions (1 min, room temperature) and provided the most uniform coatings (thickness ∼3 μm). Seven organochlorine pesticides were determined in different environmental waters using gas chromatography with electron capture detection. Despite the low thickness of the coatings, limits of detection of the entire method down to 0.13 μg/L were obtained. A comparison with the commercial polyacrylate in terms of the partition coefficients of the analytes to the coatings gave logarithm of the partition coefficient values two times higher with gallic acid than polyacrylate (although the commercial fiber is 28 times thicker). Interfiber relative standard deviation values ranged from 8.67 to 21.3%. Optimum fibers also presented an adequate lifetime (>100 extractions).
- 6 April 2017
- Published by Wiley in Journal of Separation Science
- Vol. 40 (9) , 2009-2021
Gold nanoparticles based solid‐phase microextraction coatings for determining organochlorine pesticides in aqueous environmental samples
The use of solid‐phase microextraction coatings based on gold nanoparticles was investigated, focusing the attention on the preparation of nanoparticles with nonclassical reduction agents of HAuCl4 such as gallic acid and H2O2, rather than the conventional sodium citrate. All nanoparticles were characterized by diode array spectroscopy, whereas novel nanoparticles prepared with gallic acid and H2O2 were also characterized by microscopic techniques. Solid‐phase microextraction coatings were prepared with a layer‐by‐layer approach. Gallic acid permitted the preparation of stable nanoparticles with milder experimental conditions (1 min, room temperature) and provided the most uniform coatings (thickness ∼3 μm). Seven organochlorine pesticides were determined in different environmental waters using gas chromatography with electron capture detection. Despite the low thickness of the coatings, limits of detection of the entire method down to 0.13 μg/L were obtained. A comparison with the commercial polyacrylate in terms of the partition coefficients of the analytes to the coatings gave logarithm of the partition coefficient values two times higher with gallic acid than polyacrylate (although the commercial fiber is 28 times thicker). Interfiber relative standard deviation values ranged from 8.67 to 21.3%. Optimum fibers also presented an adequate lifetime (>100 extractions).
- 5 March 2015
- Published by Taylor & Francis in Environmental Technology
- Vol. 36 (15) , 1933-1942
Green chromatography determination of fatty acid methyl esters in biodiesel
This work proposes a green, simple and rapid chromatographic methodology for separation and determination of a group of 13 fatty acids methyl esters (FAMEs) by using a capillary gas chromatography with a flame ionization detector. The method was successfully applied for the determination of FAMEs in biodiesel samples from commercial and waste cooking oils, synthesized by homogeneous catalysis. Detection and quantification limits were in the μg L−1 level. Direct injection of sample solution was compared with solid-phase extraction and solid-phase microextraction procedures, giving similar results. The lower analysis time represent considerable improvement compared with other papers. The described methodology is especially suitable for process control applications. The samples analysed showed total contents of FAMEs higher than 96.5%, which verifies the European regulations.
- 5 March 2015
- Published by Taylor & Francis in Environmental Technology
- Vol. 36 (15) , 1933-1942
Green chromatography determination of fatty acid methyl esters in biodiesel
This work proposes a green, simple and rapid chromatographic methodology for separation and determination of a group of 13 fatty acids methyl esters (FAMEs) by using a capillary gas chromatography with a flame ionization detector. The method was successfully applied for the determination of FAMEs in biodiesel samples from commercial and waste cooking oils, synthesized by homogeneous catalysis. Detection and quantification limits were in the μg L−1 level. Direct injection of sample solution was compared with solid-phase extraction and solid-phase microextraction procedures, giving similar results. The lower analysis time represent considerable improvement compared with other papers. The described methodology is especially suitable for process control applications. The samples analysed showed total contents of FAMEs higher than 96.5%, which verifies the European regulations.
- 1 July 1996
- Published by Elsevier in Microchemical Journal
- Vol. 54 (1) , 32-40
Kinetic Spectrophotometric Resolution of Mixtures of Europium, Terbium, and Lanthanum in a Micellar Medium Using Multivariate Calibration
- 1 July 1996
- Published by Elsevier in Microchemical Journal
- Vol. 54 (1) , 32-40
Kinetic Spectrophotometric Resolution of Mixtures of Europium, Terbium, and Lanthanum in a Micellar Medium Using Multivariate Calibration
- 30 May 1996
- Published by Elsevier in Clinica Chimica Acta
- Vol. 249 (1-2) , 21-36
Evaluation of multicomponent fluorimetric analytical data by use of partial least-squares calibration. Application to the determination of codeine and ephedrine in urine
- 30 May 1996
- Published by Elsevier in Clinica Chimica Acta
- Vol. 249 (1-2) , 21-36
Evaluation of multicomponent fluorimetric analytical data by use of partial least-squares calibration. Application to the determination of codeine and ephedrine in urine
- 31 July 1992
- Published by Elsevier in Clinica Chimica Acta
- Vol. 209 (1-2) , 35-46
Use of an azo derivative immobilized on an anionic resin for the determination of aluminium in water and dialysis fluids
- 31 July 1992
- Published by Elsevier in Clinica Chimica Acta
- Vol. 209 (1-2) , 35-46
Use of an azo derivative immobilized on an anionic resin for the determination of aluminium in water and dialysis fluids
- 5 November 1991
- Published by Elsevier in Analytica Chimica Acta
- Vol. 252 (1-2) , 107-113
Simultaneous determination of amitriptyline, imipramine and perphenazine in pharmaceutical preparations and blood serum by multi-wavelength spectrophotometry
- 5 November 1991
- Published by Elsevier in Analytica Chimica Acta
- Vol. 252 (1-2) , 107-113
Simultaneous determination of amitriptyline, imipramine and perphenazine in pharmaceutical preparations and blood serum by multi-wavelength spectrophotometry