Ihsan Habib Dakhil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ihsan Habib Dakhil has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Mohd Yusri Bin Mohd Yunus
Centre for Sustainability of Ecosystem & Earth Resources (Earth Centre), Universiti Malaysia Pahang, Gambang, Malaysia
4 shared publications- Ammar Salih Abbas
Department of Chemical Engineering, College of Engineering, University of Baghdad, Baghdad, Iraq
3 shared publications - Sajjad Khudhur Abbas Al-Amshawee
Centre for Sustainability of Ecosystem and Earth Resources (Earth Centre), Universiti Malaysia Pahang, Gambang, Malaysia
3 shared publications Ahmed Hassan Ali
Department of Chemical Engineering, College of Engineering, Al-Muthanna University, Al-Muthanna, Iraq image/svg+xml
2 shared publicationsGhazi F. Naser
Department of Chemical Engineering, College of Engineering, Al-Muthanna University, Al-Muthanna, Iraq image/svg+xml
2 shared publicationsAbdul Aziz Mohd Azoddein
1 shared publication
Latest Publications
- Open Access
- 1 March 2026
- Published by Al-Khwarizmi Engineering Journal in Al-Khwarizmi Engineering Journal
- Vol. 22 (1) , 14-29
Optimization of Phenol Adsorption Using Activated Carbon Derived from Spent Tea Leaves in a Packed-bed Column
This study investigates the potential of spent tea leaf-derived activated carbon (STLAC) as an adsorbent for phenol removal from simulated wastewater using a packed-bed adsorber. STLAC was prepared via chemical activation through impregnation with potassium hydroxide, followed by carbonization under controlled conditions. The physicochemical characterization of the prepared activated carbon has been confirmed. Response surface methodology (RSM) with central composite design (CCD) was utilized to optimize four operating parameters: flow rate, initial phenol concentration, bed height, and pH. A quadratic mathematical model was developed to describe the relationship between these parameters and removal efficiency. Results demonstrate the high phenol removal capacity of STLAC, achieving a maximum efficiency of 91.92% under optimal operating conditions: flow rate (11.46 mL/min), initial phenol concentration (19 mg/L), bed height (17.8 cm), and pH (6.8). The first breakthrough and saturation points were observed at 31 and 70 min, respectively. Regeneration studies have confirmed the activity of STLAC for reuse in the adsorption after five cycles, with an efficiency exceeding 75%. STLAC exhibited high efficiency in phenol removal, offering advantages in terms of sustainability and cost-effectiveness. To our knowledge, this study is the first to systematically optimize phenol removal using STLAC in a continuous packed-bed column using RSM-CCD methodology and utilize the optimized parameters for determining breakthrough characteristics. This study underscores the potential of converting agricultural waste into value-added products for environmental remediation. These results demonstrate that STLAC is a promising, low-cost, and sustainable adsorbent for removing phenol from industrial wastewater.
- 1 March 2026
- Published by Al-Khwarizmi Engineering Journal in Al-Khwarizmi Engineering Journal
- Vol. 22 (1) , 14-29
Open AccessOptimization of Phenol Adsorption Using Activated Carbon Derived from Spent Tea Leaves in a Packed-bed Column
This study investigates the potential of spent tea leaf-derived activated carbon (STLAC) as an adsorbent for phenol removal from simulated wastewater using a packed-bed adsorber. STLAC was prepared via chemical activation through impregnation with potassium hydroxide, followed by carbonization under controlled conditions. The physicochemical characterization of the prepared activated carbon has been confirmed. Response surface methodology (RSM) with central composite design (CCD) was utilized to optimize four operating parameters: flow rate, initial phenol concentration, bed height, and pH. A quadratic mathematical model was developed to describe the relationship between these parameters and removal efficiency. Results demonstrate the high phenol removal capacity of STLAC, achieving a maximum efficiency of 91.92% under optimal operating conditions: flow rate (11.46 mL/min), initial phenol concentration (19 mg/L), bed height (17.8 cm), and pH (6.8). The first breakthrough and saturation points were observed at 31 and 70 min, respectively. Regeneration studies have confirmed the activity of STLAC for reuse in the adsorption after five cycles, with an efficiency exceeding 75%. STLAC exhibited high efficiency in phenol removal, offering advantages in terms of sustainability and cost-effectiveness. To our knowledge, this study is the first to systematically optimize phenol removal using STLAC in a continuous packed-bed column using RSM-CCD methodology and utilize the optimized parameters for determining breakthrough characteristics. This study underscores the potential of converting agricultural waste into value-added products for environmental remediation. These results demonstrate that STLAC is a promising, low-cost, and sustainable adsorbent for removing phenol from industrial wastewater.
- Open Access
- 30 September 2025
- Published by Iraqi Journal of Chemical and Petroleum Engineering in Iraqi Journal of Chemical and Petroleum Engineering
- Vol. 26 (3) , 63-83
Challenges and future directions in photoelectro-Fenton techniques: A comprehensive review of emerging applications and innovations
This comprehensive review examines the fundamental principles and practical applications of heterogeneous electrochemical wastewater treatment utilizing Fenton's reactions. The fundamental equations involved in generating hydroxyl-free radicals in electro-Fenton and photoelectro-Fenton processes have been reviewed. Photoelectro-Fenton processes have been proven to be the most effective methods for mineralizing and degrading pollutants in wastewater. The primary focus is on understanding the limitations of hybrid Fenton processes and proposing practical solutions to address these challenges. Additionally, the study evaluated the significance of electrode configuration development and light penetration enhancement in promoting hydrogen peroxide production and enhancing hydroxyl radical generation. These improvements contribute to the enhanced degradation and mineralization of contaminants in groundwater. A comparative analysis of electrode materials, novel reactor configurations, and operating conditions demonstrates the relationship between preparation methods and treatment efficiency. Research gaps for improving the photoelectro-Fenton process are identified, with suggestions for future work. Studies have shown that internal light irradiation leads to higher removal efficiency compared to external lighting systems with the same light source power. The most important recommendations were utilizing multi-electrode stacked reactors to reduce energy consumption, enhancing current efficiency, the shape of the electrodes also plays a vital role in increasing light exposure on the photoanode surfaces, and conducting long-term experiments with various contaminants to demonstrate the reactor's stability, efficiency, and efficacy in treating industrial wastewater.
- 30 September 2025
- Published by Iraqi Journal of Chemical and Petroleum Engineering in Iraqi Journal of Chemical and Petroleum Engineering
- Vol. 26 (3) , 63-83
Open AccessChallenges and future directions in photoelectro-Fenton techniques: A comprehensive review of emerging applications and innovations
This comprehensive review examines the fundamental principles and practical applications of heterogeneous electrochemical wastewater treatment utilizing Fenton's reactions. The fundamental equations involved in generating hydroxyl-free radicals in electro-Fenton and photoelectro-Fenton processes have been reviewed. Photoelectro-Fenton processes have been proven to be the most effective methods for mineralizing and degrading pollutants in wastewater. The primary focus is on understanding the limitations of hybrid Fenton processes and proposing practical solutions to address these challenges. Additionally, the study evaluated the significance of electrode configuration development and light penetration enhancement in promoting hydrogen peroxide production and enhancing hydroxyl radical generation. These improvements contribute to the enhanced degradation and mineralization of contaminants in groundwater. A comparative analysis of electrode materials, novel reactor configurations, and operating conditions demonstrates the relationship between preparation methods and treatment efficiency. Research gaps for improving the photoelectro-Fenton process are identified, with suggestions for future work. Studies have shown that internal light irradiation leads to higher removal efficiency compared to external lighting systems with the same light source power. The most important recommendations were utilizing multi-electrode stacked reactors to reduce energy consumption, enhancing current efficiency, the shape of the electrodes also plays a vital role in increasing light exposure on the photoanode surfaces, and conducting long-term experiments with various contaminants to demonstrate the reactor's stability, efficiency, and efficacy in treating industrial wastewater.
- 22 September 2025
- Published by Springer Nature in Clean Technologies and Environmental Policy
- Vol. 27 (12) , 8121-8139
Preparation, characterization, and performance of potential stainless steel electrodes modified with immobilized semiconductors for persistent organic pollutants via photoelectro-Fenton process
- 22 September 2025
- Published by Springer Nature in Clean Technologies and Environmental Policy
- Vol. 27 (12) , 8121-8139
Preparation, characterization, and performance of potential stainless steel electrodes modified with immobilized semiconductors for persistent organic pollutants via photoelectro-Fenton process
- 1 August 2024
- Published by Pleiades Publishing Ltd in Petroleum Chemistry
- Vol. 64 (8) , 1055-1062
Developing a Millifluidic Flow Analysis System for Asphaltene Content Reduction in Crude Oil via Liquid-Liquid Extraction with Variable Parameters
Solvent deasphalting (SDA) of the actual heavy crude oil is one of the most critical processes in the petroleum industry, which improves the specifications of low-quality crude oil. The work shows heavy crude oil with an asphaltene content of 2.49 wt % taken from the Samawah oil refinery in southern Iraq was deasphalted using a homemade flow system with several variables. The significant variables impacting the deasphalting process were identified using the central composite design (CCD) and response surface method (RSM). The optimum conditions of the deasphalting process are n-heptane solvent, a flow rate of 31 mL/min, a mixing coil length of 172 cm, a temperature of 32°C, and a time of 3 s. It was determined that the impact of using variables occurs in the following order: mixing coil length > temperature > solvent flow rate > time in n-heptane solvent. The experimental and theoretical efficiencies of the deasphalting technique for heavy crude oil were found to be 57.94 and 56.26%, respectively.
- 1 August 2024
- Published by Pleiades Publishing Ltd in Petroleum Chemistry
- Vol. 64 (8) , 1055-1062
Developing a Millifluidic Flow Analysis System for Asphaltene Content Reduction in Crude Oil via Liquid-Liquid Extraction with Variable Parameters
Solvent deasphalting (SDA) of the actual heavy crude oil is one of the most critical processes in the petroleum industry, which improves the specifications of low-quality crude oil. The work shows heavy crude oil with an asphaltene content of 2.49 wt % taken from the Samawah oil refinery in southern Iraq was deasphalted using a homemade flow system with several variables. The significant variables impacting the deasphalting process were identified using the central composite design (CCD) and response surface method (RSM). The optimum conditions of the deasphalting process are n-heptane solvent, a flow rate of 31 mL/min, a mixing coil length of 172 cm, a temperature of 32°C, and a time of 3 s. It was determined that the impact of using variables occurs in the following order: mixing coil length > temperature > solvent flow rate > time in n-heptane solvent. The experimental and theoretical efficiencies of the deasphalting technique for heavy crude oil were found to be 57.94 and 56.26%, respectively.
- 20 May 2024
- Published by University of the Aegean in Global Nest Journal
- Vol. 26 (5) , 1-6
Evaluation of Electro-Fenton Process for Removal of Amoxicillin from Simulated Wastewater
The purpose of this work is to examine the efficiency of the Electro-Fenton process (Fenton oxidation) for the elimination of amoxicillin from simulated wastewater through response surface methodology (RSM). The effect three operating parameters that were selected for this evaluation were electrolysis time, hydrogen peroxide concentration, and the current density. The Electro-Fenton method was assessed by a set of experiments that were designed using the Box-Behnken model. The results conclude optimum parameters conditions, at 30 min electrolysis time, 30 ppm H2O2, and current density 2 amps by fixing the other two parameters; 20 ppm concentration of amoxicillin and pH of 3. The maximum removal efficiency at these conditions was 98.11%. The mathematical model concluded has a high correlation coefficient (R2= 98.3). Depending on the results, the Electro-Fenton process has proven an excellent method for the elimination of antibiotics from wastewater.
- 20 May 2024
- Published by University of the Aegean in Global Nest Journal
- Vol. 26 (5) , 1-6
Evaluation of Electro-Fenton Process for Removal of Amoxicillin from Simulated Wastewater
The purpose of this work is to examine the efficiency of the Electro-Fenton process (Fenton oxidation) for the elimination of amoxicillin from simulated wastewater through response surface methodology (RSM). The effect three operating parameters that were selected for this evaluation were electrolysis time, hydrogen peroxide concentration, and the current density. The Electro-Fenton method was assessed by a set of experiments that were designed using the Box-Behnken model. The results conclude optimum parameters conditions, at 30 min electrolysis time, 30 ppm H2O2, and current density 2 amps by fixing the other two parameters; 20 ppm concentration of amoxicillin and pH of 3. The maximum removal efficiency at these conditions was 98.11%. The mathematical model concluded has a high correlation coefficient (R2= 98.3). Depending on the results, the Electro-Fenton process has proven an excellent method for the elimination of antibiotics from wastewater.
- Open Access
- 1 January 2024
- Published by Walter de Gruyter GmbH in Open Engineering
- Vol. 14 (1)
Asphalt binder modified with recycled tyre rubber
In the last few decades, tyre rubber waste has been considered a risky issue to the ecosystem. A huge amount of used and deformed tyres is disposed of in landfill or recycled into other products. The main goal is to modify 60/70 bitumen grade to achieve 40/50 bitumen results. In this work, tyre rubber waste was added at different weights from 5 to 20% after cutting into small particles to use in the modification process of 60/70 asphalt binder. The modified asphalt was tested to meet the Iraqi standard specifications of roads and bridges. In the experimental work, Central Composite Design was applied to attain mathematical models that describes binder consistency by relating three operating parameters: tyre rubber ratio, mixing temperature and time. The predicted models relate to the penetration and softening point of the modified binder achieved R 2 of 97 and 99%, respectively. The obtained results indicated that the penetration and softening point improved after adding 20% recycled tyre rubber at 170°C and 20 min of mixing time.
- 1 January 2024
- Published by Walter de Gruyter GmbH in Open Engineering
- Vol. 14 (1)
Open AccessAsphalt binder modified with recycled tyre rubber
In the last few decades, tyre rubber waste has been considered a risky issue to the ecosystem. A huge amount of used and deformed tyres is disposed of in landfill or recycled into other products. The main goal is to modify 60/70 bitumen grade to achieve 40/50 bitumen results. In this work, tyre rubber waste was added at different weights from 5 to 20% after cutting into small particles to use in the modification process of 60/70 asphalt binder. The modified asphalt was tested to meet the Iraqi standard specifications of roads and bridges. In the experimental work, Central Composite Design was applied to attain mathematical models that describes binder consistency by relating three operating parameters: tyre rubber ratio, mixing temperature and time. The predicted models relate to the penetration and softening point of the modified binder achieved R 2 of 97 and 99%, respectively. The obtained results indicated that the penetration and softening point improved after adding 20% recycled tyre rubber at 170°C and 20 min of mixing time.
- 13 June 2023
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 32 (22) , 12992-13013
Ion exchange membrane electrodialysis for water and wastewater processing: application of ladder-type membrane spacers to impact solution concentration and flow dynamics
Concentration polarization, which creates a thin boundary layer along the membranes in electrochemical reactors and electrodialysis-related processes, is one of the main issues. Membrane spacers provide swirling motion in the stream and distribute fluid toward the membrane, which effectively breaks the polarization layer and maximizes flux steadily. Membrane spacers and the spacer-bulk attack angle are reviewed systematically in the current study. The study then in-depth reviews a ladder-type configuration composed of longitudinal (0° attack angle) and transverse (90° attack angle) filaments, and its effects on solution flow direction and hydrodynamics. The review discovered that, at the tradeoff of high-pressure losses, a laddered spacer can provide mass transfer and mixing activity along the channel while preserving comparable patterns of concentration near the membrane wall. Pressure losses are driven by a change in the direction of velocity vectors. Dead spots in the spacer design that are created by the large contribution of the spacer manifolds can be reduced using the high-pressure drop. Laddered spacers also permit long, tortuous flow paths, which help to create turbulent flow and prevent concentration polarization. The absence of spacers produces limited mixing and broad polarization effects. A major portion of streamlines changes direction at ladder spacer strands positioned transverse to the main flow by moving in a zigzag manner up and down the filaments of the spacer. Flow at 90° is perpendicular to the transverse wires in \(x\)-coordinate, no change in \(y\)-coordinate.- 13 June 2023
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 32 (22) , 12992-13013
Ion exchange membrane electrodialysis for water and wastewater processing: application of ladder-type membrane spacers to impact solution concentration and flow dynamics
Concentration polarization, which creates a thin boundary layer along the membranes in electrochemical reactors and electrodialysis-related processes, is one of the main issues. Membrane spacers provide swirling motion in the stream and distribute fluid toward the membrane, which effectively breaks the polarization layer and maximizes flux steadily. Membrane spacers and the spacer-bulk attack angle are reviewed systematically in the current study. The study then in-depth reviews a ladder-type configuration composed of longitudinal (0° attack angle) and transverse (90° attack angle) filaments, and its effects on solution flow direction and hydrodynamics. The review discovered that, at the tradeoff of high-pressure losses, a laddered spacer can provide mass transfer and mixing activity along the channel while preserving comparable patterns of concentration near the membrane wall. Pressure losses are driven by a change in the direction of velocity vectors. Dead spots in the spacer design that are created by the large contribution of the spacer manifolds can be reduced using the high-pressure drop. Laddered spacers also permit long, tortuous flow paths, which help to create turbulent flow and prevent concentration polarization. The absence of spacers produces limited mixing and broad polarization effects. A major portion of streamlines changes direction at ladder spacer strands positioned transverse to the main flow by moving in a zigzag manner up and down the filaments of the spacer. Flow at 90° is perpendicular to the transverse wires in \(x\)-coordinate, no change in \(y\)-coordinate.- Open Access
- 5 June 2023
- Published by Journal of Engineering in Journal of Engineering
- Vol. 19 (11) , 1395-1406
Adsorption of Chromium (Vi) from Aqueous Solutions using Low Cost Adsorbent: Equilibrium and Regeneration Studies
The adsorption of Cr (VI) from aqueous solution by spent tea leaves (STL) was studied at different initial Cr (VI) concentrations, adsorbent dose, pH and contact time under batch isotherm experiments The adsorption experiments were carried out at 30°C and the effects of the four parameters on chromium uptake to establish a mathematical model description percentage removal of Cr (VI). The analysis results showed that the experimental data were adequately fitted to second order polynomial model with correlation coefficients for this model was (R2 = 0.9891). The optimum operating parameters of initial Cr (VI) concentrations, adsorbent dose, pH and contact time were 50 mg/l, 0.7625 g, 3 and 100 min, respectively. At these conditions, the maximum percentage removal of Cr (VI) was 92.88%. The amounts of Cr (VI) adsorbed onto STL were highly affected by the solution pH value. Equilibrium data was modeled with Langmuir and Freundlich models isotherms. Langmuir model is found very well represent the equilibrium data with correlation factor is close to unity than the Freundlich model. The maximum monolayer adsorption capacity was found to be 47.98 mg/g at optimum conditions. The saturated adsorbent was regenerated by base treatment and found to be reuse efficiently after fourth cycleat optimum conditions as well as for safe disposal of base that contains high concentration of Cr (VI) is precipitated as barium chromate.
- 5 June 2023
- Published by Journal of Engineering in Journal of Engineering
- Vol. 19 (11) , 1395-1406
Open AccessAdsorption of Chromium (Vi) from Aqueous Solutions using Low Cost Adsorbent: Equilibrium and Regeneration Studies
The adsorption of Cr (VI) from aqueous solution by spent tea leaves (STL) was studied at different initial Cr (VI) concentrations, adsorbent dose, pH and contact time under batch isotherm experiments The adsorption experiments were carried out at 30°C and the effects of the four parameters on chromium uptake to establish a mathematical model description percentage removal of Cr (VI). The analysis results showed that the experimental data were adequately fitted to second order polynomial model with correlation coefficients for this model was (R2 = 0.9891). The optimum operating parameters of initial Cr (VI) concentrations, adsorbent dose, pH and contact time were 50 mg/l, 0.7625 g, 3 and 100 min, respectively. At these conditions, the maximum percentage removal of Cr (VI) was 92.88%. The amounts of Cr (VI) adsorbed onto STL were highly affected by the solution pH value. Equilibrium data was modeled with Langmuir and Freundlich models isotherms. Langmuir model is found very well represent the equilibrium data with correlation factor is close to unity than the Freundlich model. The maximum monolayer adsorption capacity was found to be 47.98 mg/g at optimum conditions. The saturated adsorbent was regenerated by base treatment and found to be reuse efficiently after fourth cycleat optimum conditions as well as for safe disposal of base that contains high concentration of Cr (VI) is precipitated as barium chromate.
- 24 February 2023
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 98 (11) , 2627-2638
Multilayered membrane spacer: does it enhance solution mixing?
The present review systematically investigates and illustrates the effect of multilayered membrane spacers on the features of fluid dynamics that influence all performance metrics. Multilayer spacers are frequently composed of three sets of filaments (i.e., top, middle, and bottom layers), which has the benefit of increasing mass transfer and decreasing membrane surface fouling when compared to ordinary monolayer (e.g., extruded spacer) and two‐layer spacers. The review found that the multilayer spacer's middle layer disperses primary flow to the thin side spacers placed near the membrane's surfaces. The thin side spacers will then form narrow passageways to keep the solution in situ for as long as mass transfer is achievable. The employment of thin spacers close to the membranes at satisfactory operational conditions (e.g., adequate flow velocity) results in swirling flows and incorporation of transverse and longitudinal eddies near to the membranes, reducing the boundary layer's width and making the associated ion concentration domain at the membranes much more consistent. The concept and implementation of multilayer geometry in feed channels appears to be promising, since a multilayered spacer can function at a lower maximum flow velocity than normal two‐layer spacers, saving operational energy while minimizing concentration gradients at the membrane surfaces. Furthermore, the multilayer structure's durability and mechanical strength may help to reduce membrane deformation and maintain long processes. Future studies might look at significantly reducing spacer thickness for industrial uses. © 2023 Society of Chemical Industry (SCI).
- 24 February 2023
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 98 (11) , 2627-2638
Multilayered membrane spacer: does it enhance solution mixing?
The present review systematically investigates and illustrates the effect of multilayered membrane spacers on the features of fluid dynamics that influence all performance metrics. Multilayer spacers are frequently composed of three sets of filaments (i.e., top, middle, and bottom layers), which has the benefit of increasing mass transfer and decreasing membrane surface fouling when compared to ordinary monolayer (e.g., extruded spacer) and two‐layer spacers. The review found that the multilayer spacer's middle layer disperses primary flow to the thin side spacers placed near the membrane's surfaces. The thin side spacers will then form narrow passageways to keep the solution in situ for as long as mass transfer is achievable. The employment of thin spacers close to the membranes at satisfactory operational conditions (e.g., adequate flow velocity) results in swirling flows and incorporation of transverse and longitudinal eddies near to the membranes, reducing the boundary layer's width and making the associated ion concentration domain at the membranes much more consistent. The concept and implementation of multilayer geometry in feed channels appears to be promising, since a multilayered spacer can function at a lower maximum flow velocity than normal two‐layer spacers, saving operational energy while minimizing concentration gradients at the membrane surfaces. Furthermore, the multilayer structure's durability and mechanical strength may help to reduce membrane deformation and maintain long processes. Future studies might look at significantly reducing spacer thickness for industrial uses. © 2023 Society of Chemical Industry (SCI).