Ahmad Zaidi Abdullah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Ahmad Zaidi Abdullah has a total of 128 co-authors. Here are the top co-authors by number of shared publications:
- Muzamir Isa
Universiti Malaysia Perlis
8 shared publications - Fareq Malek
School of Electrical Systems Engineering, Universiti Malaysia Perlis (UniMAP), Arau, Malaysia
5 shared publications - Mohamad Nur Khairul Hafizi Rohani
High Voltage Transient & Insulation Research Group, Center of Excellence Renewable Energy (CERE), Universiti Malaysia Perlis, Perlis, Malaysia
5 shared publications - Mohd Asri Jusoh
Universiti Malaysia Perlis (UniMAP)
4 shared publications - Nur Sabrina Md Noorpi
Universiti Malaysia Perlis (UniMAP)
4 shared publications - Nurhakimah Mohd Mokhtar
Universiti Malaysia Perlis (UniMAP)
4 shared publications
Latest Publications
- Open Access
- 16 December 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 62 (2) , 99-112
Performance of Ceramic Insulator under the Effect of Contaminated Condition
The performance of insulators is significantly impacted by harsh environmental conditions and pollution levels, which also have an impact on the dependability of transmission and distribution networks. This study examines the distributions of the electric field and potential along a string of three ceramic insulators operating under various levels of contamination. Additionally, the impact of contaminated layer thickness is examined. The partial differential equations that explain the behaviour of the electric field are solved using software that uses the FEM (Finite Element Method). The units are coated with a thin layer of contaminant to explore the impact of the contamination on the electric field and voltage distributions on the insulator surface. Finally, results pertaining to clean insulators and those pertaining to contaminated insulators under various circumstances have been compared. This study discovered that stray capacitances cause the voltage distributions along the clean insulator string to be non-linear and non-uniform. Additionally, the existence of the contamination layer tends to linearize the distribution of potential throughout the insulator's length. The distribution of the electric field along the creepage path is significantly altered by the existence of a contamination layer on the insulator, although its strength is similar to that in the clean case. For power frequency voltages, uniform contamination results in a better voltage distribution than the clean case, but the value of the electric field is nearly two times greater than in the dry case.
- 16 December 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 62 (2) , 99-112
Open AccessPerformance of Ceramic Insulator under the Effect of Contaminated Condition
The performance of insulators is significantly impacted by harsh environmental conditions and pollution levels, which also have an impact on the dependability of transmission and distribution networks. This study examines the distributions of the electric field and potential along a string of three ceramic insulators operating under various levels of contamination. Additionally, the impact of contaminated layer thickness is examined. The partial differential equations that explain the behaviour of the electric field are solved using software that uses the FEM (Finite Element Method). The units are coated with a thin layer of contaminant to explore the impact of the contamination on the electric field and voltage distributions on the insulator surface. Finally, results pertaining to clean insulators and those pertaining to contaminated insulators under various circumstances have been compared. This study discovered that stray capacitances cause the voltage distributions along the clean insulator string to be non-linear and non-uniform. Additionally, the existence of the contamination layer tends to linearize the distribution of potential throughout the insulator's length. The distribution of the electric field along the creepage path is significantly altered by the existence of a contamination layer on the insulator, although its strength is similar to that in the clean case. For power frequency voltages, uniform contamination results in a better voltage distribution than the clean case, but the value of the electric field is nearly two times greater than in the dry case.
- Open Access
- 11 November 2024
- Published by EDP Sciences in BIO Web of Conferences
- Vol. 137, 03001
Implementation of Solar Street Lighting for Empowering Rural Communities
The integration of renewable energy solutions in humanitarian projects addresses the challenges faced by underserved communities. This paper explores the design and implementation of solar street lighting systems for humanitarian efforts, aiming to enhance safety, extend productive hours, and improve quality of life. We analyze lighting needs in various contexts, such as refugee camps and rural villages, focusing on appropriate solar technologies, optimal placement, and environmental resilience. The implementation strategy includes community engagement, local maintenance training, and partnerships for sustainability. Case studies from Sub-Saharan Africa and Southeast Asia highlight practical challenges and innovative solutions, showing significant improvements in safety, economic activities, and social well-being. Recommendations for policymakers, engineers, and humanitarian workers emphasize best practices for deploying solar street lighting, underscoring renewable energy’s potential to boost sustainable development and humanitarian impact.
- 11 November 2024
- Published by EDP Sciences in BIO Web of Conferences
- Vol. 137, 03001
Open AccessImplementation of Solar Street Lighting for Empowering Rural Communities
The integration of renewable energy solutions in humanitarian projects addresses the challenges faced by underserved communities. This paper explores the design and implementation of solar street lighting systems for humanitarian efforts, aiming to enhance safety, extend productive hours, and improve quality of life. We analyze lighting needs in various contexts, such as refugee camps and rural villages, focusing on appropriate solar technologies, optimal placement, and environmental resilience. The implementation strategy includes community engagement, local maintenance training, and partnerships for sustainability. Case studies from Sub-Saharan Africa and Southeast Asia highlight practical challenges and innovative solutions, showing significant improvements in safety, economic activities, and social well-being. Recommendations for policymakers, engineers, and humanitarian workers emphasize best practices for deploying solar street lighting, underscoring renewable energy’s potential to boost sustainable development and humanitarian impact.
- Open Access
- 2 October 2024
- Published by Human Resources Management Academic Research Society (HRMARS) in International Journal of Academic Research in Business and Social Sciences
- Vol. 14 (10) , 440-448
Development of Smart Fire Detection System for Household Kitchen
HRMARS is well established journal publisher based in Pakistan. It is publishing prominent journals in social sciences since 2011.
- 2 October 2024
- Published by Human Resources Management Academic Research Society (HRMARS) in International Journal of Academic Research in Business and Social Sciences
- Vol. 14 (10) , 440-448
Open AccessDevelopment of Smart Fire Detection System for Household Kitchen
HRMARS is well established journal publisher based in Pakistan. It is publishing prominent journals in social sciences since 2011.
- Open Access
- 10 June 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 46 (2) , 37-49
Investigation of Solar Energy Production by Photovoltaic (PV) System Using Rooftop Coating as Passive Cooling Technique at Bukit Tinggi, Malaysia
Solar power energy is known as one of the popular renewable energies that has been studied by many researchers all over the world. Photovoltaic (PV) panels are used to produce electricity directly from the sunlight. Cooling is a very important technique used in the PV system industry. This is because the heat generated by the PV system can reduce its performance, resulting in higher costs. The cooling technique consists of two types: active cooling technique and passive cooling technique. In this investigation, the passive cooling technique is selected. This is due to its advantages such as less maintenance, did not require large space and affordable. The nanocoating method is a widely used as passive cooling method for glass and PV panels. However, this investigation is carried out to investigate the rooftop coating integrated with PV panels system at Bukit Tinggi due to the limited previous research found worldwide. M168 coating is applied to the rooftop and the effects on the PV systems have been investigated. Two sets of On-Grid Connected PV systems were set up; where each system consists of two inverters were set up to analyze the output. The results then were recorded. According to the investigation results, the PV system with a coated rooftop generates a higher voltage of 249.80V and total power production difference of 16% compared to the PV system with an uncoated rooftop. Although the temperature for coated rooftop PV system quite higher than the uncoated rooftop PV system at the beginning, then the temperature constantly lower than the uncoated rooftop PV system. This study can be used as a guideline for PV system passive cooling methods at Bukit Tinggi.
- 10 June 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 46 (2) , 37-49
Open AccessInvestigation of Solar Energy Production by Photovoltaic (PV) System Using Rooftop Coating as Passive Cooling Technique at Bukit Tinggi, Malaysia
Solar power energy is known as one of the popular renewable energies that has been studied by many researchers all over the world. Photovoltaic (PV) panels are used to produce electricity directly from the sunlight. Cooling is a very important technique used in the PV system industry. This is because the heat generated by the PV system can reduce its performance, resulting in higher costs. The cooling technique consists of two types: active cooling technique and passive cooling technique. In this investigation, the passive cooling technique is selected. This is due to its advantages such as less maintenance, did not require large space and affordable. The nanocoating method is a widely used as passive cooling method for glass and PV panels. However, this investigation is carried out to investigate the rooftop coating integrated with PV panels system at Bukit Tinggi due to the limited previous research found worldwide. M168 coating is applied to the rooftop and the effects on the PV systems have been investigated. Two sets of On-Grid Connected PV systems were set up; where each system consists of two inverters were set up to analyze the output. The results then were recorded. According to the investigation results, the PV system with a coated rooftop generates a higher voltage of 249.80V and total power production difference of 16% compared to the PV system with an uncoated rooftop. Although the temperature for coated rooftop PV system quite higher than the uncoated rooftop PV system at the beginning, then the temperature constantly lower than the uncoated rooftop PV system. This study can be used as a guideline for PV system passive cooling methods at Bukit Tinggi.
- Open Access
- 20 March 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 41 (2) , 194-207
Development of Second Order High Frequency Filter for Partial Discharge Measurement
Partial discharge (PD) can occur on any high-voltage equipment. This study is particularly concerned with the PD that occurs on underground cables. Researchers frequently struggle to isolate interference noise from the PD signal when doing PD measurements. Therefore, to reduce the interference noise during PD measurements, Sallen-Key high-pass filters with a 500 kHz, or a little bit higher cut-off frequency are designed. This filter is designed with a designated cut-off frequency value because the frequency range of the PD signal is between 1 MHz to 1 GHz. Based on the results of experimental testing for actual filters, the designed filter is a high-pass filter with a cut-off frequency of 500KHz. When the generator function's input frequency values are set between 500 kHz and 2.4 MHz, the signal will pass the filter and provide output values for both frequencies and amplitude. However, at frequencies lower than 500 kHz, the signal is beginning to be filtered and the output signal's amplitude is getting close to zero. Based on the PD testing results, there is interference on the PD signal shown on the oscilloscope when a 1kV supply is applied to an underground cable without using a filter. But, when the proposed filter is used in PD testing, the ripple voltage is reduced from 123 mV to 67 mV. This proves that when the designed filter is used in PD testing, it can reduce interference noise on the PD signal.
- 20 March 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 41 (2) , 194-207
Open AccessDevelopment of Second Order High Frequency Filter for Partial Discharge Measurement
Partial discharge (PD) can occur on any high-voltage equipment. This study is particularly concerned with the PD that occurs on underground cables. Researchers frequently struggle to isolate interference noise from the PD signal when doing PD measurements. Therefore, to reduce the interference noise during PD measurements, Sallen-Key high-pass filters with a 500 kHz, or a little bit higher cut-off frequency are designed. This filter is designed with a designated cut-off frequency value because the frequency range of the PD signal is between 1 MHz to 1 GHz. Based on the results of experimental testing for actual filters, the designed filter is a high-pass filter with a cut-off frequency of 500KHz. When the generator function's input frequency values are set between 500 kHz and 2.4 MHz, the signal will pass the filter and provide output values for both frequencies and amplitude. However, at frequencies lower than 500 kHz, the signal is beginning to be filtered and the output signal's amplitude is getting close to zero. Based on the PD testing results, there is interference on the PD signal shown on the oscilloscope when a 1kV supply is applied to an underground cable without using a filter. But, when the proposed filter is used in PD testing, the ripple voltage is reduced from 123 mV to 67 mV. This proves that when the designed filter is used in PD testing, it can reduce interference noise on the PD signal.
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 380-384
First Principles Enhanced Electronic Band Structure of Back Contact in CdTe Solar Cells using DFT+U Method
Cadmium telluride (CdTe) superstrate solar cells have captivated the industry with their remarkable cost-effectiveness. However, optimizing the composition and optoelectrical properties of optimal back surface field (BSF) which can act as a lattice matching interface between the back contact and absorber layer remains a key challenge due to the work function disparity of p-CdTe with metal contacts. In this study, the influence of the Hubbard U parameter on the calculated electronic properties of ZnTe as an optimal BSF compound is presented using the density functional theory (DFT) technique. The Hubbard U value progressively increased from 1 to 4.2 to analyze its influence on the band diagram and Total Density of States (TDOS) in a full comparison of DFT and DFT+U approaches. As the value of Hubbard U increased, the band gap energy exhibited a corresponding increase from 1.20 eV to 2.24 eV, respectively. In comparison, the DFT+U approach with a value of 4.2 exhibited superior accuracy in predicting the band gap of ZnTe, yielding a value of 2.24 eV that closely approximated experimental measurements. This finding reinforces the relevance of employing Hubbard U to achieve more accurate and reliable band gap values for any material doping.
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 380-384
First Principles Enhanced Electronic Band Structure of Back Contact in CdTe Solar Cells using DFT+U Method
Cadmium telluride (CdTe) superstrate solar cells have captivated the industry with their remarkable cost-effectiveness. However, optimizing the composition and optoelectrical properties of optimal back surface field (BSF) which can act as a lattice matching interface between the back contact and absorber layer remains a key challenge due to the work function disparity of p-CdTe with metal contacts. In this study, the influence of the Hubbard U parameter on the calculated electronic properties of ZnTe as an optimal BSF compound is presented using the density functional theory (DFT) technique. The Hubbard U value progressively increased from 1 to 4.2 to analyze its influence on the band diagram and Total Density of States (TDOS) in a full comparison of DFT and DFT+U approaches. As the value of Hubbard U increased, the band gap energy exhibited a corresponding increase from 1.20 eV to 2.24 eV, respectively. In comparison, the DFT+U approach with a value of 4.2 exhibited superior accuracy in predicting the band gap of ZnTe, yielding a value of 2.24 eV that closely approximated experimental measurements. This finding reinforces the relevance of employing Hubbard U to achieve more accurate and reliable band gap values for any material doping.
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 63-68
Partial Discharge Rise Time Characteristic based on Experimental Measurement in Power Cable
This study presents a comprehensive investigation into the rise time characteristics of partial discharges (PD) in cable insulation through experimental measurements. Partial discharges are a critical phenomenon in high-voltage systems, serving as an early indicator of insulation degradation. Understanding the rise time of partial discharges is essential for assessing the severity of insulation defects and ensuring the reliability of power cable systems. The experimental setup involved controlled conditions to induce partial discharges in cable samples, allowing for precise measurement and analysis of the rise time. The study explores the correlation between rise time and different factors such as cable design, insulation material, and defect type. Results indicate that the rise time of partial discharges exhibits distinct patterns based on these factors, providing valuable insights into the nature of insulation defects. The findings contribute to the development of effective diagnostic tools for condition monitoring in power cable systems, ultimately enhancing the reliability and safety of electrical infrastructure.
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 63-68
Partial Discharge Rise Time Characteristic based on Experimental Measurement in Power Cable
This study presents a comprehensive investigation into the rise time characteristics of partial discharges (PD) in cable insulation through experimental measurements. Partial discharges are a critical phenomenon in high-voltage systems, serving as an early indicator of insulation degradation. Understanding the rise time of partial discharges is essential for assessing the severity of insulation defects and ensuring the reliability of power cable systems. The experimental setup involved controlled conditions to induce partial discharges in cable samples, allowing for precise measurement and analysis of the rise time. The study explores the correlation between rise time and different factors such as cable design, insulation material, and defect type. Results indicate that the rise time of partial discharges exhibits distinct patterns based on these factors, providing valuable insights into the nature of insulation defects. The findings contribute to the development of effective diagnostic tools for condition monitoring in power cable systems, ultimately enhancing the reliability and safety of electrical infrastructure.
- Open Access
- 4 August 2023
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 31 (3) , 145-154
Measurement and Identification of Partial Discharge in 11kV XLPE Cable Jointing
The reliability of power networks can be compromised by failures in cable connections, which are often caused by poor insulation quality. The use of different insulating materials during the connection process can result in defects, leading to partial discharge (PD) in high voltage equipment. PD measurements using a Rogowski Coil sensor and a high-efficiency Oscilloscope, following the IEC-60270 guidelines, are a widely recognized method for evaluating the quality of insulation systems. Experimental measurement was performed at university high voltage laboratory. This paper focuses on measuring PDs in extension (joint) cables, where they typically occur, specifically in 11kV XLPE jointing cables, and comparing them with ordinary cables without jointing. The project aims to analyze PD signal characteristics and identify partial discharge patterns in the time and frequency domains using MATLAB. .
- 4 August 2023
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 31 (3) , 145-154
Open AccessMeasurement and Identification of Partial Discharge in 11kV XLPE Cable Jointing
The reliability of power networks can be compromised by failures in cable connections, which are often caused by poor insulation quality. The use of different insulating materials during the connection process can result in defects, leading to partial discharge (PD) in high voltage equipment. PD measurements using a Rogowski Coil sensor and a high-efficiency Oscilloscope, following the IEC-60270 guidelines, are a widely recognized method for evaluating the quality of insulation systems. Experimental measurement was performed at university high voltage laboratory. This paper focuses on measuring PDs in extension (joint) cables, where they typically occur, specifically in 11kV XLPE jointing cables, and comparing them with ordinary cables without jointing. The project aims to analyze PD signal characteristics and identify partial discharge patterns in the time and frequency domains using MATLAB. .
- Open Access
- 31 July 2023
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 107 (1) , 58-79
A Contemporary Review of High Voltage Partial Discharge Detection and Recognition Techniques
This review article provides a summary of the most advanced approaches and advancements in the detection and recognition of high voltage partial discharge (PD). It discusses numerous detecting technologies, such as electrical, acoustic, and optical approaches, as well as their merits and disadvantages. It also discusses current developments in signal processing and pattern recognition algorithms used for PD detection and classification. Lastly, the study covers the challenges and limitations in high voltage PD detection and identification studies, as well as potential future solutions.
- 31 July 2023
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 107 (1) , 58-79
Open AccessA Contemporary Review of High Voltage Partial Discharge Detection and Recognition Techniques
This review article provides a summary of the most advanced approaches and advancements in the detection and recognition of high voltage partial discharge (PD). It discusses numerous detecting technologies, such as electrical, acoustic, and optical approaches, as well as their merits and disadvantages. It also discusses current developments in signal processing and pattern recognition algorithms used for PD detection and classification. Lastly, the study covers the challenges and limitations in high voltage PD detection and identification studies, as well as potential future solutions.
- Open Access
- 8 March 2023
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 30 (1) , 331-343
Review Study of Image De-Noising on Digital Image Processing and Applications
This paper reviews several studies of image de-noising on digital image processing and applications. Noisy images contain different noise that exist either due to environment or electronic interferences. Ergo, de-noising is crucial to eliminate the noise that disturb data collecting process. The impact of de-noising on image processing can result for accurate and precise data collected from the image. Additionally, de-noising process required several crucial steps that help to enhance knowledge on digital image and its application. Hence, study and understanding de-noising can improve multiple aspect such as image quality, data sensitivity and specificity, accuracy of the collected data, and increase the percentage of each parameter.
- 8 March 2023
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 30 (1) , 331-343
Open AccessReview Study of Image De-Noising on Digital Image Processing and Applications
This paper reviews several studies of image de-noising on digital image processing and applications. Noisy images contain different noise that exist either due to environment or electronic interferences. Ergo, de-noising is crucial to eliminate the noise that disturb data collecting process. The impact of de-noising on image processing can result for accurate and precise data collected from the image. Additionally, de-noising process required several crucial steps that help to enhance knowledge on digital image and its application. Hence, study and understanding de-noising can improve multiple aspect such as image quality, data sensitivity and specificity, accuracy of the collected data, and increase the percentage of each parameter.