Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Aleksandr Sergeevich Anikin has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimization of Traction Electric Drive with Frequency Control

    by Vladimir Kodkin, Alexander Anikin, Alexander Baldenkov

    Traction motors in electric transport are most often synchronous permanent magnet motors (PMSMs). Induction motors (IMs) have large dimensions and stator current amplitudes under comparable loads. Traditional IM control methods do not solve these problems. Recent studies have shown that by changing the main magnetic flux in the IM in accordance with the load, these characteristics of the asynchronous electric drive can be significantly improved. Standard frequency converters do not allow for the implementation of these algorithms. But it makes sense to conduct a potential assessment of the capabilities of this algorithm to reduce the total stator currents of traction IMs. This article analyzes the results of real tests of a special vehicle for transporting rock inside mines, conducted several years ago at a mining equipment plant and in several mines in Russia. The prototype of the special transport vehicle has a load capacity of 15 tons, and its traction electric drive is based on four motor wheels with a total power of 100 kW and a frequency converter from the company “Vacon” (Vaasa, Finland). The tests were conducted at the plant’s testing ground and in real mine conditions. These tests allowed us to obtain information about the operation of the asynchronous electric drive under dynamically changing loads in a wide range, which is very difficult to obtain on laboratory benches or in industrial enterprise conditions. The experiments confirmed the efficiency of the optimization algorithm for asynchronous electric drives with frequency control. At the same time, the weight, size, and electrical parameters of the drive are as close as possible to those of direct current drives.


  • Open Access

    Frequency Criterion for the Existence of Sliding Processes in Control Systems with an Arbitrary Variable Structure

    by Vladimir Kodkin, Ekaterina Kuznetsova, Alexander Anikin, Alexander A. Baldenkov

    The article proposes a criterion for the existence of sliding processes according to the frequency characteristics of the control device and the control object. It is shown that the conditions for the existence of slip are equivalent to the conditions for the absolute stability of equivalent circuits of the original systems with a variable structure. This approach is proposed by the authors as an alternative to the method of phase trajectories and state space equations used by other researchers. Frequency criteria make it possible to formulate several practical engineering provisions that are very important for the implementation of this control method in real electric drives. The main conclusions are confirmed by simulation of both processes in systems with a variable structure and in equivalent circuits.


  • Open Access

    SUBSTANTIATION OF ENGINEERING METHODS FOR IDENTIFYING OPTIMIZATION MODES OF ASYNCHRONOUS ELECTRIC DRIVES

    by South Ural State University, V.L. Kodkin, М.а. Григорьев, E.A. Kuznetsova, A.S. Anikin, А.а. Baldenkov, N.A. Loginova

    Asynchronous electric drive with frequency control are widely applied in the different industries. Traditional methods of analysis of operating mode of asynchronous electric drives are the equivalent circuits and vector diagrams. The result of their application is not most often visual and effective. Often the simplifications required for visual clarity are too great. This is the case with the interpretation of the popular optimization of power consumption by reducing the amplitude of the stator voltage. The article proposes a rationale for the modified equivalent circuits and vector diagrams, which makes it possible to evaluate how this optimization affects the entire complex of parameters and variables that characterize the mode of operation of an asynchronous electric drive - changes in rotation speed, slip and rotor current. Simplified vector diagrams and equivalent circuits are proposed, which allow estimating the active and reactive power flows in the electric drive and their changes while optimizing the stator voltage amplitude. Based on the proposed equivalent schemes, calculations were carried out showing the nature of the change in the rotor and stator currents with variations in the stator voltage. The proposed calculation methods made it possible to carry out a comprehensive assessment of the control method for asynchronous electric drives with the main magnetic flux, determined by the ratio of the amplitude of the voltage applied to the motor stator to its frequency, which is significantly lower than the nominal value. Асинхронные электроприводы с частотным регулированием широко применяются в самых разных отраслях промышленности. Традиционные методы анализа режимов работы асинхронных электроприводов – схемы замещения и векторные диаграммы – все еще широко применяются для анализа различных режимов работы. Достаточно часто результат их применения не слишком нагляден и эффективен. Часто упрощения, необходимые для наглядности, слишком значительны. Так обстоит дело с интерпретацией популярной оптимизации потребляемой мощности снижением амплитуды статорного напряжения. В статье предлагается обоснование измененных схем замещения и векторных диаграмм, позволяющее оценить, как эта оптимизация влияет на весь комплекс параметров и переменных, характеризующих режим работы асинхронного электропривода – изменения скорости вращения, скольжения и роторного тока. Предложены упрощенные векторные диаграммы и схемы замещения, которые позволяют оценить потоки активной и реактивной мощности в электроприводе и их изменения при оптимизации амплитуды статорного напряжения. На основании предложенных схем замещения проведены расчеты, показывающие характер изменения токов ротора и статора при вариациях статорного напряжения. Предложенные методы расчета позволили провести всестороннюю оценку метода управления асинхронными электроприводами при основном магнитном потоке, определяемым отношением амплитуды напряжения подаваемого на статор двигателя к его частоте, существенно ниже номинального значения.


  • Open Access

    ENGINEERING METHODS FOR CALCULATING THE OPERATING MODES OF ASYNCHRONOUS ELECTRIC DRIVES WITH A WEAKENED MAIN MAGNETIC FLUX

    by V.L. Kodkin, South Ural State University, M.A. Grigorev, E.A. Kuznetsova, A.S. Anikin, A.A. Baldenkov, N.A. Loginova

    This article discusses engineering methods for calculating the operating modes of asynchronous electric drives with frequency control with a reduced main magnetic flux. Magnetization currents and rotor currents are calculated by methods formed on the basis of simplified equivalent circuits for induction motors and vector diagrams. The conditions for the minimum stator current are given, it is proved that this state corresponds to the equality of the amplitudes of the magnetizing current and the rotor current (reactive and active currents, respectively). This provision makes it possible to estimate the current of the rotor of an asynchronous electric motor when the main magnetic flux is weakened, and the calculation of the rotor and magnetization currents is also carried out according to experimental data. The proposed calculation methods are necessary for optimizing the operating modes of asynchronous electric drives operating with a load less than the nominal one. This optimization consists in reducing the maximum amplitude of the stator voltage. The proposed methods make it possible to evaluate the decrease in the magnetization current and the increase in the rotor current, which may turn out to be excessive. В данной статье рассматриваются инженерные методы расчетов режимов работы асинхронных электроприводов с частотным управлением при уменьшенном основном магнитном потоке. Токи намагничивания и токи ротора рассчитываются методами, сформированными на базе упрощенных схем замещения асинхронных двигателей и векторных диаграмм. Приводятся условия минимального тока статора, доказывается, что это состояние соответствует равенству амплитуд тока намагничивания и тока ротора (реактивного и активного токов соответственно). Это положение позволяет дать оценку тока ротора асинхронного электродвигателя при ослаблении основного магнитного потока, а также производится расчет токов ротора и намагничивания по экспериментальным данным. Предложенные методы расчета необходимы при оптимизации режимов работы асинхронных электроприводов, работающих с нагрузкой меньше номинальной. Эта оптимизация заключается в снижении максимальной амплитуды статорного напряжения. Предлагаемые методы позволяют провести оценку происходящих при этом уменьшении тока намагничивания и увеличения тока ротора, которое может оказаться чрезмерным.


  • Open Access

    Experimental study of the VFD's speed stabilization processes under torque disturbances

    by Vladimir L. Kodkin, Aleksandr S. Anikin

    Maintaining speed with various jumps and changes in load torque is one of the main tasks of variable frequency drives (VFD). The article considers the operation of the VFD under the influence of periodic perturbations of variable frequency and amplitude. The dependence of the transient function of the VFD and the family of frequency characteristics associated with it on the frequency of the stator voltage and slip underlies the methodology for experimental studies of such drives. The traditional method is based on the response to harmonic stimulation and works well for a non-linear system. In the course of the work, it was found that the introduction of dynamic positive feedback (DPF) allows to compensate for disturbances of varying frequency and amplitude. Experiments with a sinusoidal change in the load torque have shown the effectiveness of introducing the DPF in front of conventional sensorless control systems (vector and scalar).

  • Open Access

    Efficiency of Applying the Nyquist and V.M. Popov Criteria for Stability Analysis of Linearized Automatic Control Systems in Electromechanics and Power Engineering

    by Vladimir Kodkin, Alexander Anikin, Ekaterina Kuznetsova

    It is well known that all real automatic control systems (ACS) are significantly nonlinear systems. Along with this, in engineering analysis the simplifications of their mathematic description, that is, linearization, are inevitable. These simplifications naturally introduce errors into engineering calculations. For the most complicated calculation of stability conditions, these errors can be very significant, since they lead to not only incorrect forecast of the ACS condition but also to the operating inability of the designed ACS. Most often, engineers simplify nonlinear structures in their calculations. In other words, they linearize these structures according to one of the numerous approaches which have been developed over 100 years. Calculation methods for linear ACS, in particular the Nyquist criterion, can be applied to the already linearized structure for the calculation of ACS stability condition. In this article, the authors suppose that for electromechanical and power ACS it would be more effective to widely use the absolute stability criterions or hyperstability which were developed when solving the “Aizerman problem” by V.M. Popov in the 1960s of the 20th century. This solution is not used as widely as the Nyquist criterion despite its outstanding qualities. In this article, the assumption was made that it is effective to apply the stability criterion of nonlinear ACS for the linearized models of nonlinear systems. Otherwise speaking, it is effective to use the criterion of V.M. Popov and its interpretation according to the logarithmic frequency characteristics of the ACS proposed earlier by the authors of the article. The authors provide simple and illustrative examples and give the results of the simulation.


  • Open Access

    Experimental Studies of Nonlinear Dynamics of Asynchronous Electric Drives with Variable Load

    by Vladimir Kodkin, Alexander Anikin

    This article presents the results of the analysis of experimental data that were obtained during industrial tests of an adjustable asynchronous traction electric drive of a shuttle car for the mining industry. During these tests, by changing the parameters of the stator voltage, the stator currents of the induction motor were optimized when the load changes over a wide range (from −1.5 Tn to + 1.5 Tn). The authors managed to significantly reduce the effective values of the stator currents of the motor, but at the same time it was found that, with the load and even the rate of its change, oscillations of the effective values of currents with variable amplitude and frequency occur. It turned out to be very difficult to explain these oscillations and the variability of their parameters using traditional mathematical methods for describing processes in asynchronous electric motors. Vector equations and diagrams are valid only at constant frequencies of the stator voltage and, in the modes of their significant changes, which exist during self-oscillations of the effective values of the motor stator current, their error is very large. To analyze the conditions of the self-oscillations, it was proposed to use nonlinear continuous transfer functions that describe the formation of torque in induction motors. The article shows how such transfer functions make it possible to take into account the influence of the load torque and the speed of its change on the parameters of the self-oscillations of the effective values of the stator current of asynchronous electric drives experiencing such loads. The article proposes a qualitative analysis of the results of experiments carried out on real tracks of the movement of the shuttle car. The analysis of experimental data confirmed the effectiveness of using nonlinear transfer functions to evaluate the dynamics of asynchronous electric drives and the sufficient accuracy of the proposed method. In the course of research, it is shown how the conditions of the boundary stability of the drive depend on external loads that change the nonlinear transfer function of the induction motor. As a result, it was found that the condition of boundary stability and the parameters of the self-oscillations are affected not only by the magnitude, but also by the rate of load change. The article made assumptions about possible options for the effective correction of asynchronous electric drives experiencing variable loads.


  • Open Access

    A Method for Assessing the Stability of Digital Automatic Control Systems (ACS) with Discrete Elements. Hypothesis and Simulation Results

    by Vladimir Kodkin, Alexander Baldenkov, Alexander Anikin

    The article presents a new approach to the analysis of the stability of automatic systems with discrete links. In almost all modern automatic control systems (ACS), there are links that break signals in time. These are power controlled switches—transistors or thyristors operating in a pulsed mode and digital links in regulators. Time discretization significantly affects the stability of processes in the automatic control system. The theoretical analysis of such systems is rather complicated and requires a significant change in engineering approaches to analysis. With the improvement of digital controllers and a significant increase in their performance, this problem has practically been forgotten. However, its mathematical “content” has not changed since the 1980s when discreteness began to play a major role in hindering the transition to digital automatic control systems. In this paper, we propose a new approach that consists of interpreting the sampling operation by a link with the proposed frequency characteristic, which determines the suppression of input high-frequency signals. This link greatly simplifies engineering calculations and demonstrates the new capabilities of sampling systems. These possibilities include the rational distribution of digitalization resources—the number of bits and the sampling interval between the regulator channels, depending on the frequency range of the efficiency of these channels. We verify and confirm our theoretical statements through simulations and show how this approach makes it possible to formulate new principles of construction of seemingly well-known controllers—PID (Proportional Integral Differential) controllers and variable structure systems (VSS).


  • Open Access

    On the Physical Nature of Frequency Control Problems of Induction Motor Drives

    by Kodkin Vladimir, Anikin Alexander

    This article considers the possibility of connecting the problems of the engineering synthesis of frequency control systems for induction motor drives (IMD) with the theory of the identification of IMD based on the equations of a generalized AC electric machine. The article presents experimental studies of load parrying in IMD with vector (VC) and scalar (SC) controls. These results indicate the absence of fundamental advantages in a drive with VC. This advantage should manifest in a more efficient formation of the moment and fast transients. A method was proposed for describing IMD by nonlinear transfer functions, making it possible to formulate the principle of the correction of IMD and a method for assessing their efficiency. The article shows that the correction based on the proposed nonlinear transfer functions of the induction motor is much more efficient than the traditional VC, which was confirmed by detailed experiments and modeling. The most important results are given in the article. An assumption was made that the efficiency advantage was due to more accurate identification of the dynamics of an IMD with a gear function instead of vector equations.


  • Open Access

    Prospects for Increasing the Dynamic Efficiency of Asynchronous Double-Feed Machines and Wind Power Generators Using Structural Methods and Solutions

    by Vladimir L. Kodkin, Alexandr S. Anikin, Alexandr A. Baldenkov

    The chapter proposes to consider the problems of control of asynchronous machines with dual power supply, as a nonlinear structure, the transfer functions of which depend on the frequency of the stator voltage and the relative slip. The authors cite the results of research confirming the high efficiency of control of asynchronous electric motors, using cross-dynamic connections on the developed torque or a signal close to it (active component of the motor stator current). The proposed correction operates in a wide range of changes in the rotation and sliding speeds of the asynchronous electric generator. This is especially important for wind turbines that need to remain efficient at different speeds. As a justification, the results of experiments, modeling and industrial application of control algorithms with positive torque coupling are presented. Research results suggest that such algorithms will improve the efficiency of wind power by 5–10%.