RMRadek Mounajjed

Radek Mounajjed

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Radek Mounajjed has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Adjustment of CAD–CAM crowns with and without a 3D‐printed model: Comparative study of marginal fit

    by Marwan Al Akkad, Bedirhan Savas Yigit, Iva Voborna, Vaclav Prokupek, Oluwafunmibi Fasanya, Thomas Salinas, Radek Mounajjed

    Purpose: This study evaluated and compared the marginal fit of CAD–CAM zirconia crown copings with and without a 3D‐printed control model. Materials and Methods: This prospective in vitro trial involved 30 zirconia crown copings made from the same STL file. These were divided into two groups. Half of them had their own 3D‐printed control model made from the same STL file (With‐Printed‐Model group), whereas the other half lacked any control model (No‐Printed‐Model group). Both groups underwent manual adjustments in a systematic way. Their marginal gaps were evaluated using a digital optical microscope from eight zones: buccal, mesiobuccal, mesial, mesiopalatal, palatal, distopalatal, distal, and distobuccal. Results: The mean values with standard deviations for the With‐Printed‐Model and No‐Printed‐Model groups were 15.18 ± 14.49 and 12.46 ± 14.09 µm, respectively. All crown copings from both groups were below 75 µm. Statistical analysis showed a significant difference between the two groups. Conclusion: The No‐Printed‐Model group demonstrated superior marginal fit compared to the With‐Printed‐Model group. However, the largest marginal gaps from each group were still within the clinically acceptable range below 75 µm. Although the 3D‐printed control model did not improve marginal fit, its primary function is to effectively identify major manufacturing errors.

  • Open Access

    Effectiveness of laser-assisted gingivectomy compared to surgical methods: a systematic review

    by Omar Hamadah, Saed Almahayni, Raghad Ghazzawi, Radek Mounajjed, Walid Altayeb, Marwa Khalil

    Background: Lasers have demonstrated their potential as an effective alternative to the scalpel for gingivectomy procedures. Therefore, it is essential to evaluate their efficacy and safety. This article summarizes human studies comparing the effectiveness of laser-assisted gingivectomy with conventional surgical methods. Methods: A comprehensive electronic search was conducted in Cochrane, PubMed/MEDLINE, ScienceDirect, and Google Scholar using the terms “Gingivectomy”, “Gingivoplasty”, “Crown lengthening”, “Gingival surgery”, and “LASER” to identify human studies that compared laser-assisted gingivectomy with traditional surgical methods up until December 2022. The inclusion criteria were as follows: English language, use of laser as the primary treatment tool, and study designs including randomized controlled trials, controlled clinical trials, clinical trials, and comparative studies. Results: Twenty-two studies met the inclusion criteria and were analyzed. Diode lasers (810–940 nm) and Erbium, chromium-doped yttrium scandium gallium garnet laser (Er,Cr:YSGG) lasers caused less postoperative pain than conventional flap surgery, while the neodymium-doped yttrium aluminum garnet (Nd:YAG) laser resulted in higher initial pain. The diode 808 nm laser yielded mixed results—one study reported pain levels comparable to those of scalpels, while another noted reduced pain with laser use. However, one study indicated greater use of analgesics in laser-treated patients, suggesting increased discomfort. Lasers, particularly carbon dioxide (CO2) and diode 810 nm lasers, provided superior hemostasis compared to scalpels, with the Er,Cr:YSGG laser in flapless osteotomy minimizing bleeding. Additionally, no sutures were required in the laser-treated groups. The stability of the gingival margins after laser treatment was found to be similar to that of the scalpel. Discussion: All lasers discussed in this article can be safely and effectively used for gingivectomy as an alternative to conventional surgical methods. Laser treatment demonstrated superior clinical outcomes in terms of pain, patient satisfaction, hemostasis, recovery period, and periodontal health.


  • Open Access

    Assessment of impact of a control die on marginal fidelity of milled zirconia crown copings for finishing and polishing

    by Marwan Al Akkad, John Sorensen, Omar Hamadah, Iva Voborna, Marek Matoušek, Radek Mounajjed

    Purpose: This study evaluated and compared the marginal fidelity of milled zirconia copings before and after finishing and polishing with and without a control die.Materials and Methods: This prospective multicenter in vitro trial involved two methods regularly used in two clinics for hybrid and full‐digital workflows. A typodont mandibular molar was prepared. From each workflow, 20 zirconia crown copings were milled from a single scan. Ten zirconia crown copings were assigned randomly from each workflow to be finished and polished. Finishing and polishing in the hybrid workflow were done directly on the typodont, representing the control die. There were four groups in this study: No‐die‐Before (full‐digital without finishing and polishing), No‐die‐After (hybrid without finishing and polishing), Die‐based‐Before (full‐digital with finishing and polishing), and Die‐based‐After (hybrid with finishing and polishing). The typodont tooth was divided into eight zones for systematic measurement. All groups were evaluated using a digital optical microscope.Results: The mean values with the standard deviation of No‐die‐Before, No‐die‐After, Die‐based‐Before, and Die‐based‐After groups were 24.90 ± 23.88, 30.62 ± 32.63, 21.03 ± 16.65, and 18.93 ± 18.27, respectively. The maximum values for the No‐die‐Before and No‐die‐After groups were 124 and 131 µm, respectively. All the values in the Die‐based‐Before and Die‐based‐After groups were less than the acceptable marginal gap of 75 µm.Conclusions: There was no statistical significance between the two workflows. However, the control die enabled achieving superior accuracy. Without it, the marginal gap might worsen after finishing and polishing in the full‐digital workflow.


  • Open Access

    Assessment of the readiness of restorations manufactured by CAD/CAM in terms of marginal fit (Part I)

    by Radek Mounajjed, Thomas Taylor, Omar Hamadah, Iva Voborná, Marwan Al-Akkad

    Background: The master cast is the gold standard for the control and eventual adjustment of restorations produced by conventional procedures. Some digital workflow bypasses the master cast and relies completely on the precision of the CAD/CAM restoration. Aim: To examine the reproducibility of the margins of CAD/CAM restorations generated from a single digital scan. Also, to check the readiness of these restorations for delivery directly after fabrication without adjustment on a master cast and thereby eliminate the need for the master cast. Methods: A total of 18 metal substructures made from cobalt chrome alloy were fabricated utilizing a single STL file. The circumference was divided into eight zones. The vertical marginal discrepancy (VMD) was measured at each zone of each metal substructure, with optical microscopy at ×200 magnification. Results: Measurements of vertical marginal discrepancy were in a range of (−94: 300) with a mean of 62 ± 60 μm. A one-way ANOVA test revealed that the mean VMD is significantly different among the 18 substructures (F17, 1,134 = 63.948, p < 0.001). Conclusion: Although all the received substructures were fabricated from the same scan file, they were not identical and varied widely, and they were going outside the acceptable range in some zones. Within the limitations of this study, the marginal fit can be improved by extraoral adjustments on the master cast. Thus, skipping the master cast deprives the dentist of delivering a restoration of higher quality.


  • Open Access

    Pulpotomy using Portland cement in Mature Permanent Teeth with Irreversible Pulpitis

    by Sami Albatal, Chaza Kouchaji, Marwan Al-Akkad, Radek Mounajjed

    Tento ?l?nok opisuje vykon?vanie pulpot?mie u die?a?a s pou?it?m portlandsk?ho cementu v trvalom mol?ri s uzavret?mi apexami a ireverzibilnou pulpit?dou. 9-ro?n? pacient sa 4 - 5 dn? s?a?oval na boles? v oblasti prav?ho zadn?ho zuba. Po komple...

  • Open Access

    Post-endodontic treatment using composite resin cement and fiber post

    by Daniel Černý, Radek Mounajjed

    Adhesive post-endodontic treatment does not yet have a generally accepted clinical protocol. We perform this procedure in our clinical practice since 2006. We have developed a clinically successful protocol. Tissues and materials which relate to the the procedure are described following available research. Protocol is described in step-by-step.

  • A comparison between modified and conventional surgical techniques for surgical lip repositioning in the management of the gummy smile

    by Asmaa Alammar, Omar Heshmeh, Radek Mounajjed, Michaela Goodson, Omar Hamadah

    Aim: The aim of this study was to evaluate and compare conventional and modified lip repositioning surgical techniques used for management of gummy smile involving hyperactive lip elevator muscles.Methods and Materials.: A prospective study was conducted between April 2016 and May 2017. Twenty two adult patients aged 18‐38 years with gummy smile ranging from 4 to 6 mm because of soft tissue disorders were included in the study. All patients were treated in the oral and maxillofacial department at Damascus University. The sample was divided into two groups of 11 patients. The first group was treated by the conventional standard technique, and the second group treated by a modified study technique. The amount of gingival display in full smile was evaluated in both groups following each intervention.Results: Both groups exhibited a statistically significant reduction in the measurement of gummy smile at month 1 and 6 postoperatively (P < .05), but there was no significant difference in gingival display at 3 months in either group postoperatively (P > .05). The recent study showed a significant difference in gingival display between 3 and 6 months postoperatively in group 1, but no significant difference in group 2.Conclusion: This study showed that the modified technique utilized in treating gummy smile has less relapse after surgery, shows excellent cosmesis and compared to the conventional technique, greater sustainability.Clinical significance: The recent increase in demand for an esthetic smile has led to the development a modification of conventional lip repositioning for correcting gummy smile by myotomy of lip elevator muscles. This modified technique offers less relapse and greater stability post‐operatively than the conventional technique.


  • Open Access

    The marginal fit of lithium disilicate crowns: Press vs. CAD/CAM

    by Basel Azar, Steve Eckert, Josef Kunkela, Tomaš Ingr, Radek Mounajjed

    This study aimed to compare the vertical marginal gap of teeth restored with lithium disilicate crowns fabricated using CAD/CAM or by pressed ceramic approach. Twenty mandibular third molar teeth were collected after surgical extractions and prepared to receive full veneer crowns. Teeth were optically scanned and lithium disilicate blocks were used to fabricate crowns using CAD/CAM technique. Polyvinyl siloxane impressions of the prepared teeth were made and monolithic pressed lithium disilicate crowns were fabricated. The marginal gap was measured using optical microscope at 200× magnification (Keyence VHX-5000, Japan). Statistical analysis was performed using Wilcoxon test. The lithium disilicate pressed crowns had significantly smaller (p = 0.006) marginal gaps (38 ± 12 μm) than the lithium disilicate CAD/CAM crowns (45 ± 12 μm). This research indicates that lithium disilicate crowns fabricated with the press technique have measurably smaller marginal gaps compared with those fabricated with CAD/CAM technique within in vitro environments. The marginal gaps achieved by the crowns across all groups were within a clinically acceptable range.


  • Retrospective 9-Year Clinical Outcome Report on Adhesive Post-endodontic Treatment of Anterior Teeth Using Prefabricated Fiber Posts

    by Daniel Cerny, Steven Eckert, Radek Mounajjed

    Daniel Cerny, MUDr/Steven Eckert, DDS, MS/Radek Mounajjed, DDS, PhD: Purpose: To evaluate survival rates of adhesive post-endodontic buildups made using composite resin and prefabricated quartz fiber posts. Materials and Methods: This retrospective study included all buildups placed between January 1, 2008, and December 31, 2012, by a single skilled operator using a single-adhesive system and dual-curing cement. Final restorations included direct composites, various types of crowns, and fixed partial dentures. During recall, teeth were inspected by four different dentists, and survival analysis was performed using Kaplan-Meier test. Results: A total of 301 root canal?treated incisors and canines were restored. At repeat follow-up appointments, 291 restorations were still in function after a mean time of service of 7.13 ? 2.11 years. Cumulative survival probability at 9 years was 96.0%. No parameter observed was found by log-rank test to have a statistically significant effect on survival rate. Conclusion: Adhesive buildup with prefabricated fiber posts in anterior teeth is a reliable method of post-endodontic treatment in this given clinical protocol.