Marwan Al Akkad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Marwan Al Akkad has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Radek Mounajjed
Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry Palacky University Olomouc Olomouc Czech Republic
4 shared publications - Iva Voborná
Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry Palacky University Olomouc Olomouc Czech Republic
2 shared publications - Samer Al Akkad
Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Al-Sham Private University, Damascus, Syria
2 shared publications - Bedirhan Savas Yigit
Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry Palacky University Olomouc Olomouc Czech Republic
1 shared publication - Chaza Kouchaji
Department of Pediatric Dentistry, Faculty of Dentistry, Damascus University, Syria
1 shared publication Iva Voborná
Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacký University Olomouc, Olomouc, Czech Republic
1 shared publication
Latest Publications
- Open Access
- 9 July 2026
- Published by Wiley in Journal of Prosthodontics
Adjustment of CAD–CAM crowns with and without a 3D‐printed model: Comparative study of marginal fit
Purpose: This study evaluated and compared the marginal fit of CAD–CAM zirconia crown copings with and without a 3D‐printed control model. Materials and Methods: This prospective in vitro trial involved 30 zirconia crown copings made from the same STL file. These were divided into two groups. Half of them had their own 3D‐printed control model made from the same STL file (With‐Printed‐Model group), whereas the other half lacked any control model (No‐Printed‐Model group). Both groups underwent manual adjustments in a systematic way. Their marginal gaps were evaluated using a digital optical microscope from eight zones: buccal, mesiobuccal, mesial, mesiopalatal, palatal, distopalatal, distal, and distobuccal. Results: The mean values with standard deviations for the With‐Printed‐Model and No‐Printed‐Model groups were 15.18 ± 14.49 and 12.46 ± 14.09 µm, respectively. All crown copings from both groups were below 75 µm. Statistical analysis showed a significant difference between the two groups. Conclusion: The No‐Printed‐Model group demonstrated superior marginal fit compared to the With‐Printed‐Model group. However, the largest marginal gaps from each group were still within the clinically acceptable range below 75 µm. Although the 3D‐printed control model did not improve marginal fit, its primary function is to effectively identify major manufacturing errors.
- 9 July 2026
- Published by Wiley in Journal of Prosthodontics
Open AccessAdjustment of CAD–CAM crowns with and without a 3D‐printed model: Comparative study of marginal fit
Purpose: This study evaluated and compared the marginal fit of CAD–CAM zirconia crown copings with and without a 3D‐printed control model. Materials and Methods: This prospective in vitro trial involved 30 zirconia crown copings made from the same STL file. These were divided into two groups. Half of them had their own 3D‐printed control model made from the same STL file (With‐Printed‐Model group), whereas the other half lacked any control model (No‐Printed‐Model group). Both groups underwent manual adjustments in a systematic way. Their marginal gaps were evaluated using a digital optical microscope from eight zones: buccal, mesiobuccal, mesial, mesiopalatal, palatal, distopalatal, distal, and distobuccal. Results: The mean values with standard deviations for the With‐Printed‐Model and No‐Printed‐Model groups were 15.18 ± 14.49 and 12.46 ± 14.09 µm, respectively. All crown copings from both groups were below 75 µm. Statistical analysis showed a significant difference between the two groups. Conclusion: The No‐Printed‐Model group demonstrated superior marginal fit compared to the With‐Printed‐Model group. However, the largest marginal gaps from each group were still within the clinically acceptable range below 75 µm. Although the 3D‐printed control model did not improve marginal fit, its primary function is to effectively identify major manufacturing errors.
- Open Access
- 26 May 2026
- Published by Charles University in Prague, Karolinum Press in Acta Medica (Hradec Kralove, Czech Republic)
- Vol. 69 (1) , 26-31
Comparison between the Prognosis of Temporomandibular Disorders with and without Accompanying Otologic Symptoms after Non-Invasive Non-Pharmacological Treatment: Controlled Clinical Trial
Background: Otologic symptoms are commonly reported by patients with temporomandibular disorders. Objective: This study aims to investigate the likely outcome or progression of temporomandibular disorders with and without accompanying otologic symptoms when treated in the dental clinic. Methods: The study is registered under the International Standard Randomised Controlled Trial Number: ISRCTN49976724, DOI: 10.1186/ISRCTN49976724. Forty patients with temporomandibular disorders were included and allocated into two groups: Control group (n=20): isolated temporomandibular disorders symptoms, and Experimental group (n=20): temporomandibular disorders symptoms with otologic symptoms (confirmed by otorhinolaryngological evaluation to exclude primary ear pathology). All participants underwent non-invasive, non-pharmacological treatment. The treatment contained physiotherapy and custom-made occlusal splints. Outcomes (full/partial/no recovery) were assessed at 3 months by a single maxillofacial surgeon, with follow-up every 3 weeks. Statistical analysis included Fisher’s exact test and odds ratios. Results: Fisher’s exact test revealed a statistically significant association between group allocation and recovery outcomes (χ 2 =5.979, p=0.041). The odds ratio was 5.33. Conclusion: The presence of otological symptoms accompanying temporomandibular disorders might predict a better prognosis after non-invasive, non-pharmacological treatment, perhaps not as a direct predictor per se but as a confounding factor.
- 26 May 2026
- Published by Charles University in Prague, Karolinum Press in Acta Medica (Hradec Kralove, Czech Republic)
- Vol. 69 (1) , 26-31
Open AccessComparison between the Prognosis of Temporomandibular Disorders with and without Accompanying Otologic Symptoms after Non-Invasive Non-Pharmacological Treatment: Controlled Clinical Trial
Background: Otologic symptoms are commonly reported by patients with temporomandibular disorders. Objective: This study aims to investigate the likely outcome or progression of temporomandibular disorders with and without accompanying otologic symptoms when treated in the dental clinic. Methods: The study is registered under the International Standard Randomised Controlled Trial Number: ISRCTN49976724, DOI: 10.1186/ISRCTN49976724. Forty patients with temporomandibular disorders were included and allocated into two groups: Control group (n=20): isolated temporomandibular disorders symptoms, and Experimental group (n=20): temporomandibular disorders symptoms with otologic symptoms (confirmed by otorhinolaryngological evaluation to exclude primary ear pathology). All participants underwent non-invasive, non-pharmacological treatment. The treatment contained physiotherapy and custom-made occlusal splints. Outcomes (full/partial/no recovery) were assessed at 3 months by a single maxillofacial surgeon, with follow-up every 3 weeks. Statistical analysis included Fisher’s exact test and odds ratios. Results: Fisher’s exact test revealed a statistically significant association between group allocation and recovery outcomes (χ 2 =5.979, p=0.041). The odds ratio was 5.33. Conclusion: The presence of otological symptoms accompanying temporomandibular disorders might predict a better prognosis after non-invasive, non-pharmacological treatment, perhaps not as a direct predictor per se but as a confounding factor.
- Open Access
- 17 April 2025
- Published by Wiley in Journal of Prosthodontics
Assessment of impact of a control die on marginal fidelity of milled zirconia crown copings for finishing and polishing
Purpose: This study evaluated and compared the marginal fidelity of milled zirconia copings before and after finishing and polishing with and without a control die.Materials and Methods: This prospective multicenter in vitro trial involved two methods regularly used in two clinics for hybrid and full‐digital workflows. A typodont mandibular molar was prepared. From each workflow, 20 zirconia crown copings were milled from a single scan. Ten zirconia crown copings were assigned randomly from each workflow to be finished and polished. Finishing and polishing in the hybrid workflow were done directly on the typodont, representing the control die. There were four groups in this study: No‐die‐Before (full‐digital without finishing and polishing), No‐die‐After (hybrid without finishing and polishing), Die‐based‐Before (full‐digital with finishing and polishing), and Die‐based‐After (hybrid with finishing and polishing). The typodont tooth was divided into eight zones for systematic measurement. All groups were evaluated using a digital optical microscope.Results: The mean values with the standard deviation of No‐die‐Before, No‐die‐After, Die‐based‐Before, and Die‐based‐After groups were 24.90 ± 23.88, 30.62 ± 32.63, 21.03 ± 16.65, and 18.93 ± 18.27, respectively. The maximum values for the No‐die‐Before and No‐die‐After groups were 124 and 131 µm, respectively. All the values in the Die‐based‐Before and Die‐based‐After groups were less than the acceptable marginal gap of 75 µm.Conclusions: There was no statistical significance between the two workflows. However, the control die enabled achieving superior accuracy. Without it, the marginal gap might worsen after finishing and polishing in the full‐digital workflow.
- 17 April 2025
- Published by Wiley in Journal of Prosthodontics
Open AccessAssessment of impact of a control die on marginal fidelity of milled zirconia crown copings for finishing and polishing
Purpose: This study evaluated and compared the marginal fidelity of milled zirconia copings before and after finishing and polishing with and without a control die.Materials and Methods: This prospective multicenter in vitro trial involved two methods regularly used in two clinics for hybrid and full‐digital workflows. A typodont mandibular molar was prepared. From each workflow, 20 zirconia crown copings were milled from a single scan. Ten zirconia crown copings were assigned randomly from each workflow to be finished and polished. Finishing and polishing in the hybrid workflow were done directly on the typodont, representing the control die. There were four groups in this study: No‐die‐Before (full‐digital without finishing and polishing), No‐die‐After (hybrid without finishing and polishing), Die‐based‐Before (full‐digital with finishing and polishing), and Die‐based‐After (hybrid with finishing and polishing). The typodont tooth was divided into eight zones for systematic measurement. All groups were evaluated using a digital optical microscope.Results: The mean values with the standard deviation of No‐die‐Before, No‐die‐After, Die‐based‐Before, and Die‐based‐After groups were 24.90 ± 23.88, 30.62 ± 32.63, 21.03 ± 16.65, and 18.93 ± 18.27, respectively. The maximum values for the No‐die‐Before and No‐die‐After groups were 124 and 131 µm, respectively. All the values in the Die‐based‐Before and Die‐based‐After groups were less than the acceptable marginal gap of 75 µm.Conclusions: There was no statistical significance between the two workflows. However, the control die enabled achieving superior accuracy. Without it, the marginal gap might worsen after finishing and polishing in the full‐digital workflow.
- Open Access
- 24 September 2024
- Published by Springer Nature
How ear symptoms affect recovery from jaw disorders using non-drug non-surgical treatment
- 24 September 2024
- Published by Springer Nature
Open AccessHow ear symptoms affect recovery from jaw disorders using non-drug non-surgical treatment
- Open Access
Assessment of the readiness of restorations manufactured by CAD/CAM in terms of marginal fit (Part I)
Background: The master cast is the gold standard for the control and eventual adjustment of restorations produced by conventional procedures. Some digital workflow bypasses the master cast and relies completely on the precision of the CAD/CAM restoration. Aim: To examine the reproducibility of the margins of CAD/CAM restorations generated from a single digital scan. Also, to check the readiness of these restorations for delivery directly after fabrication without adjustment on a master cast and thereby eliminate the need for the master cast. Methods: A total of 18 metal substructures made from cobalt chrome alloy were fabricated utilizing a single STL file. The circumference was divided into eight zones. The vertical marginal discrepancy (VMD) was measured at each zone of each metal substructure, with optical microscopy at ×200 magnification. Results: Measurements of vertical marginal discrepancy were in a range of (−94: 300) with a mean of 62 ± 60 μm. A one-way ANOVA test revealed that the mean VMD is significantly different among the 18 substructures (F17, 1,134 = 63.948, p < 0.001). Conclusion: Although all the received substructures were fabricated from the same scan file, they were not identical and varied widely, and they were going outside the acceptable range in some zones. Within the limitations of this study, the marginal fit can be improved by extraoral adjustments on the master cast. Thus, skipping the master cast deprives the dentist of delivering a restoration of higher quality.
Open AccessAssessment of the readiness of restorations manufactured by CAD/CAM in terms of marginal fit (Part I)
Background: The master cast is the gold standard for the control and eventual adjustment of restorations produced by conventional procedures. Some digital workflow bypasses the master cast and relies completely on the precision of the CAD/CAM restoration. Aim: To examine the reproducibility of the margins of CAD/CAM restorations generated from a single digital scan. Also, to check the readiness of these restorations for delivery directly after fabrication without adjustment on a master cast and thereby eliminate the need for the master cast. Methods: A total of 18 metal substructures made from cobalt chrome alloy were fabricated utilizing a single STL file. The circumference was divided into eight zones. The vertical marginal discrepancy (VMD) was measured at each zone of each metal substructure, with optical microscopy at ×200 magnification. Results: Measurements of vertical marginal discrepancy were in a range of (−94: 300) with a mean of 62 ± 60 μm. A one-way ANOVA test revealed that the mean VMD is significantly different among the 18 substructures (F17, 1,134 = 63.948, p < 0.001). Conclusion: Although all the received substructures were fabricated from the same scan file, they were not identical and varied widely, and they were going outside the acceptable range in some zones. Within the limitations of this study, the marginal fit can be improved by extraoral adjustments on the master cast. Thus, skipping the master cast deprives the dentist of delivering a restoration of higher quality.
- Open Access
- 15 December 2021
- Published by Slovenská Komora Zubných Lekárov in Stomatológ
- Vol. 31 (2) , 46-51
Pulpotomy using Portland cement in Mature Permanent Teeth with Irreversible Pulpitis
Tento ?l?nok opisuje vykon?vanie pulpot?mie u die?a?a s pou?it?m portlandsk?ho cementu v trvalom mol?ri s uzavret?mi apexami a ireverzibilnou pulpit?dou. 9-ro?n? pacient sa 4 - 5 dn? s?a?oval na boles? v oblasti prav?ho zadn?ho zuba. Po komple...
- 15 December 2021
- Published by Slovenská Komora Zubných Lekárov in Stomatológ
- Vol. 31 (2) , 46-51
Open AccessPulpotomy using Portland cement in Mature Permanent Teeth with Irreversible Pulpitis
Tento ?l?nok opisuje vykon?vanie pulpot?mie u die?a?a s pou?it?m portlandsk?ho cementu v trvalom mol?ri s uzavret?mi apexami a ireverzibilnou pulpit?dou. 9-ro?n? pacient sa 4 - 5 dn? s?a?oval na boles? v oblasti prav?ho zadn?ho zuba. Po komple...