Suchismita Sarangi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Suchismita Sarangi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Suresh V. Garimella
School of Mechanical Engineering
5 shared publications- Justin A. Weibel
School of Mechanical Engineering, Purdue University , West Lafayette, IN 47907
4 shared publications Jayathi Y. Murthy
2 shared publicationsKarthik K. Bodla
2 shared publicationsClaude Wright
Intel Corporation, Hillsboro, OR
1 shared publicationGarimella Suresh V.
1 shared publication
Latest Publications
- 8 November 2016
- Published by Wiley in Journal of Heat Transfer
- Vol. 139 (2) , 021502
Quantitative Evaluation of the Dependence of Pool Boiling Heat Transfer Enhancement on Sintered Particle Coating Characteristics
Immersion cooling strategies often employ surface enhancements to improve the pool boiling heat transfer performance. Sintered particle/powder coatings have been commonly used on smooth surfaces to reduce the wall superheat and increase the critical heat flux (CHF). However, there is no unified understanding of the role of coating characteristics on pool boiling heat transfer enhancement. The morphology and size of the particles affect the pore geometry, permeability, thermal conductivity, and other characteristics of the sintered coating. In turn, these characteristics impact the heat transfer coefficient and CHF during boiling. In this study, pool boiling of FC-72 is experimentally investigated using copper surfaces coated with a layer of sintered copper particles of irregular and spherical morphologies for a range of porosities (∼40–80%). Particles of the same effective diameter (90–106 μm) are sintered to yield identical coating thicknesses (∼4 particle diameters). The porous structure formed by sintering is characterized using microcomputed tomography (μ-CT) scanning to study the geometric and effective thermophysical properties of the coatings. The boiling performance of the porous coatings is analyzed. Coating characteristics that influence the boiling heat transfer coefficient and CHF are identified and their relative strength of dependence analyzed using regression analysis. Irregular particles yield higher heat transfer coefficients compared to spherical particles at similar porosity. The coating porosity, pore diameter, unit necking area, unit interfacial area, effective thermal conductivity, and effective permeability are observed to be the most critical coating properties affecting the boiling heat transfer coefficient and CHF.
- 8 November 2016
- Published by Wiley in Journal of Heat Transfer
- Vol. 139 (2) , 021502
Quantitative Evaluation of the Dependence of Pool Boiling Heat Transfer Enhancement on Sintered Particle Coating Characteristics
Immersion cooling strategies often employ surface enhancements to improve the pool boiling heat transfer performance. Sintered particle/powder coatings have been commonly used on smooth surfaces to reduce the wall superheat and increase the critical heat flux (CHF). However, there is no unified understanding of the role of coating characteristics on pool boiling heat transfer enhancement. The morphology and size of the particles affect the pore geometry, permeability, thermal conductivity, and other characteristics of the sintered coating. In turn, these characteristics impact the heat transfer coefficient and CHF during boiling. In this study, pool boiling of FC-72 is experimentally investigated using copper surfaces coated with a layer of sintered copper particles of irregular and spherical morphologies for a range of porosities (∼40–80%). Particles of the same effective diameter (90–106 μm) are sintered to yield identical coating thicknesses (∼4 particle diameters). The porous structure formed by sintering is characterized using microcomputed tomography (μ-CT) scanning to study the geometric and effective thermophysical properties of the coatings. The boiling performance of the porous coatings is analyzed. Coating characteristics that influence the boiling heat transfer coefficient and CHF are identified and their relative strength of dependence analyzed using regression analysis. Irregular particles yield higher heat transfer coefficients compared to spherical particles at similar porosity. The coating porosity, pore diameter, unit necking area, unit interfacial area, effective thermal conductivity, and effective permeability are observed to be the most critical coating properties affecting the boiling heat transfer coefficient and CHF.
- 13 November 2015
- Published by ASME International
Effect of Particle Morphology on Pool Boiling From Surfaces Coated With Sintered Particles
Immersion cooling strategies often employ surface enhancements to improve the pool boiling heat transfer performance. Sintered particle/powder coatings with different constituent particle sizes and total layer thicknesses have been commonly used on smooth surfaces to reduce the wall superheat and increase the critical heat flux during pool boiling. However, the role of the particle morphology on pool boiling has not been explicitly investigated. Since the morphology of the particles affects the pore shape, permeability, surface roughness, effective conductivity and diffusivity of the sintered coating, it will impact the heat transfer coefficient and critical heat flux during boiling. In this study, pool boiling of FC-72 is experimentally investigated using copper surfaces coated with a layer of sintered copper particles of irregular, dendritic and spherical morphologies. In order to isolate the effect of particle morphology, particles with the same effective diameter (90–106 μm) are sintered under controlled conditions that yield the same porosity (∼60%) and coating thickness (∼6 particle diameters) for all samples tested. The effects of particle morphology on the incipient wall superheat, nucleate boiling heat transfer coefficient, and critical heat flux are analyzed. The morphology of the pore structure in the coating formed by sintering is observed with SEM images; bubble nucleation and departure characteristics affecting the heat transfer performance of the coatings are qualitatively assessed with the aid of high-speed flow visualizations to corroborate the trends observed in the boiling curves. The irregular particles are observed to show the highest heat transfer coefficient, followed by dendritic and then spherical particles. The critical heat flux is found to be independent of the particle morphology.
- 13 November 2015
- Published by ASME International
Effect of Particle Morphology on Pool Boiling From Surfaces Coated With Sintered Particles
Immersion cooling strategies often employ surface enhancements to improve the pool boiling heat transfer performance. Sintered particle/powder coatings with different constituent particle sizes and total layer thicknesses have been commonly used on smooth surfaces to reduce the wall superheat and increase the critical heat flux during pool boiling. However, the role of the particle morphology on pool boiling has not been explicitly investigated. Since the morphology of the particles affects the pore shape, permeability, surface roughness, effective conductivity and diffusivity of the sintered coating, it will impact the heat transfer coefficient and critical heat flux during boiling. In this study, pool boiling of FC-72 is experimentally investigated using copper surfaces coated with a layer of sintered copper particles of irregular, dendritic and spherical morphologies. In order to isolate the effect of particle morphology, particles with the same effective diameter (90–106 μm) are sintered under controlled conditions that yield the same porosity (∼60%) and coating thickness (∼6 particle diameters) for all samples tested. The effects of particle morphology on the incipient wall superheat, nucleate boiling heat transfer coefficient, and critical heat flux are analyzed. The morphology of the pore structure in the coating formed by sintering is observed with SEM images; bubble nucleation and departure characteristics affecting the heat transfer performance of the coatings are qualitatively assessed with the aid of high-speed flow visualizations to corroborate the trends observed in the boiling curves. The irregular particles are observed to show the highest heat transfer coefficient, followed by dendritic and then spherical particles. The critical heat flux is found to be independent of the particle morphology.
- 6 July 2015
- Published by ASME International
Evaluation of Cooling Technologies for Xeon Phi™ Based High Performance Computing Clusters
Efficient and compact cooling technologies play a pivotal role in determining the performance of high performance computing devices when used with highly parallel workloads in supercomputers. The present work deals with evaluation of different cooling technologies and elucidating their impact on the power, performance, and thermal management of Intel® Xeon Phi™ coprocessors. The scope of the study is to demonstrate enhanced cooling capabilities beyond today’s fan-driven air-cooling for use in high performance computing (HPC) technology, thereby improving the overall Performance per Watt in datacenters. The various cooling technologies evaluated for the present study include air-cooling, liquid-cooling and two-phase immersion-cooling. Air-cooling is evaluated by providing controlled airflow to a cluster of eight 300 W Xeon Phi coprocessors (7120P). For liquid-cooling, two different cold plate technologies are evaluated, viz, Formed tube cold pates and Microchannel based cold plates. Liquidcooling with water as working fluid, is evaluated on single Xeon Phi coprocessors, using inlet conditions in accordance with ASHRAE W2 and W3 class liquid cooled datacenter baselines. For immersion-cooling, a cluster of multiple Xeon Phi coprocessors is evaluated, with three different types of Integrated Heat Spreaders (IHS), viz., bare IHS, IHS with a Boiling Enhancement Coating (BEC) and IHS with BEC coated pin-fins. The entire cluster is immersed in a pool of Novec 649 (3M fluid, boiling point 49 °C at 1 atm), with polycarbonate spacers used to reduce the volume of fluid required, to achieve target fluid/power density of ∼ 3 L/kW. Flow visualization is performed to provide further insight into the boiling behavior during the immersion-cooling process. Performance per Watt of the Xeon Phi coprocessors is characterized as a function of the cooling technologies using several HPC workloads benchmark run at constant frequency, such as the Intel proprietary Power Thermal Utility (PTU), and industry standard HPC benchmarks LINPACK, DGEMM, SGEMM and STREAM. The major parameters measured by sensors on the coprocessor include total power to the coprocessor, CPU temperature, and memory temperature, while the calculated outputs of interest also include the performance per watt and equivalent thermal resistance. As expected, it is observed that both liquid and immersion cooling show improved performance per Watt and lower CPU temperature compared to air-cooling. In addition to elucidating the performance/watt improvement, this work reports on the relationship of cooling technologies on total power consumed by the Xeon-Phi card as a function of coolant inlet temperatures. Further, the paper discusses form-factor advantages to liquid and immersion cooling and compares technologies on a common platform. Finally, the paper concludes by discussing datacenter optimization for cooling in the context of leakage power control for Xeon-Phi coprocessors.
- 6 July 2015
- Published by ASME International
Evaluation of Cooling Technologies for Xeon Phi™ Based High Performance Computing Clusters
Efficient and compact cooling technologies play a pivotal role in determining the performance of high performance computing devices when used with highly parallel workloads in supercomputers. The present work deals with evaluation of different cooling technologies and elucidating their impact on the power, performance, and thermal management of Intel® Xeon Phi™ coprocessors. The scope of the study is to demonstrate enhanced cooling capabilities beyond today’s fan-driven air-cooling for use in high performance computing (HPC) technology, thereby improving the overall Performance per Watt in datacenters. The various cooling technologies evaluated for the present study include air-cooling, liquid-cooling and two-phase immersion-cooling. Air-cooling is evaluated by providing controlled airflow to a cluster of eight 300 W Xeon Phi coprocessors (7120P). For liquid-cooling, two different cold plate technologies are evaluated, viz, Formed tube cold pates and Microchannel based cold plates. Liquidcooling with water as working fluid, is evaluated on single Xeon Phi coprocessors, using inlet conditions in accordance with ASHRAE W2 and W3 class liquid cooled datacenter baselines. For immersion-cooling, a cluster of multiple Xeon Phi coprocessors is evaluated, with three different types of Integrated Heat Spreaders (IHS), viz., bare IHS, IHS with a Boiling Enhancement Coating (BEC) and IHS with BEC coated pin-fins. The entire cluster is immersed in a pool of Novec 649 (3M fluid, boiling point 49 °C at 1 atm), with polycarbonate spacers used to reduce the volume of fluid required, to achieve target fluid/power density of ∼ 3 L/kW. Flow visualization is performed to provide further insight into the boiling behavior during the immersion-cooling process. Performance per Watt of the Xeon Phi coprocessors is characterized as a function of the cooling technologies using several HPC workloads benchmark run at constant frequency, such as the Intel proprietary Power Thermal Utility (PTU), and industry standard HPC benchmarks LINPACK, DGEMM, SGEMM and STREAM. The major parameters measured by sensors on the coprocessor include total power to the coprocessor, CPU temperature, and memory temperature, while the calculated outputs of interest also include the performance per watt and equivalent thermal resistance. As expected, it is observed that both liquid and immersion cooling show improved performance per Watt and lower CPU temperature compared to air-cooling. In addition to elucidating the performance/watt improvement, this work reports on the relationship of cooling technologies on total power consumed by the Xeon-Phi card as a function of coolant inlet temperatures. Further, the paper discusses form-factor advantages to liquid and immersion cooling and compares technologies on a common platform. Finally, the paper concludes by discussing datacenter optimization for cooling in the context of leakage power control for Xeon-Phi coprocessors.
- 1 February 2015
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 81, 103-113
Effect of particle size on surface-coating enhancement of pool boiling heat transfer
- 1 February 2015
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 81, 103-113
Effect of particle size on surface-coating enhancement of pool boiling heat transfer
- 1 February 2014
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 69, 92-105
Manifold microchannel heat sink design using optimization under uncertainty
- 1 February 2014
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 69, 92-105
Manifold microchannel heat sink design using optimization under uncertainty
- 18 July 2013
- Published by Wiley in Journal of Heat Transfer
- Vol. 135 (8) , 080908
Pool Boiling Heat Transfer From Deformable Particulate Beds
- 18 July 2013
- Published by Wiley in Journal of Heat Transfer
- Vol. 135 (8) , 080908
Pool Boiling Heat Transfer From Deformable Particulate Beds
- 9 November 2012
- Published by ASME International
- p. 1141-1153
Optimization Under Uncertainty of Manifold Microchannel Heat Sinks
Conventional microchannel heat sinks provide good heat dissipation capability but are associated with high pressure drop and corresponding pumping power. The use of a manifold system that distributes the flow into the microchannels through multiple, alternating inlet and outlet pairs is investigated here. This manifold arrangement greatly reduces the pressure drop incurred due to the smaller flow paths, while simultaneously increasing the heat transfer coefficient by tripping the thermal boundary layers. A three-dimensional numerical model is developed and validated, to study the effect of various geometric parameters on the performance of the manifold microchannel heat sink. Apart from a deterministic analysis, a probabilistic optimization study is also performed. In the presence of uncertainties in the geometric and operating parameters of the system, this probabilistic optimization approach yields an optimal design that is also robust and reliable. Uncertainty-based optimization also yields auxiliary information regarding local and global sensitivities and helps identify the input parameters to which outputs are most sensitive. This information can be used to design improved experiments targeted at the most sensitive inputs. Optimization under uncertainty also provides a quantitative estimate of the allowable uncertainty in input parameters for an acceptable uncertainty in the relevant output parameters. The optimal geometric design parameters with uncertainties that maximize heat transfer coefficient while minimizing pressure drop for fixed input conditions are identified for a manifold microchannel heat sink. A comparison between the deterministic and probabilistic optimization results is also presented.
- 9 November 2012
- Published by ASME International
- p. 1141-1153
Optimization Under Uncertainty of Manifold Microchannel Heat Sinks
Conventional microchannel heat sinks provide good heat dissipation capability but are associated with high pressure drop and corresponding pumping power. The use of a manifold system that distributes the flow into the microchannels through multiple, alternating inlet and outlet pairs is investigated here. This manifold arrangement greatly reduces the pressure drop incurred due to the smaller flow paths, while simultaneously increasing the heat transfer coefficient by tripping the thermal boundary layers. A three-dimensional numerical model is developed and validated, to study the effect of various geometric parameters on the performance of the manifold microchannel heat sink. Apart from a deterministic analysis, a probabilistic optimization study is also performed. In the presence of uncertainties in the geometric and operating parameters of the system, this probabilistic optimization approach yields an optimal design that is also robust and reliable. Uncertainty-based optimization also yields auxiliary information regarding local and global sensitivities and helps identify the input parameters to which outputs are most sensitive. This information can be used to design improved experiments targeted at the most sensitive inputs. Optimization under uncertainty also provides a quantitative estimate of the allowable uncertainty in input parameters for an acceptable uncertainty in the relevant output parameters. The optimal geometric design parameters with uncertainties that maximize heat transfer coefficient while minimizing pressure drop for fixed input conditions are identified for a manifold microchannel heat sink. A comparison between the deterministic and probabilistic optimization results is also presented.