Jorge Pelegrin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jorge Pelegrin has a total of 775 co-authors. Here are the top co-authors by number of shared publications:
- Yifeng Yang
Institute of Cryogenics, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, U.K.
9 shared publications - Francesco Monrabal
Donostia International Physics Center
8 shared publications - J. Renner
Universidade de Santiago de Compostela
8 shared publications - Josè Juan Gomez Cadenas
Donostia International Physics Center
8 shared publications - F. J. Mora
Universitat Politècnica de València (UPV), ETSIT
7 shared publications - F. Lopez
Donostia International Physics Center
7 shared publications
Latest Publications
- Open Access
- 17 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1066
Publisher Correction: Sensitivity of the Hyper-Kamiokande experiment to neutrino oscillation parameters using accelerator neutrinos
- 17 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1066
Open AccessPublisher Correction: Sensitivity of the Hyper-Kamiokande experiment to neutrino oscillation parameters using accelerator neutrinos
- Open Access
- 10 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1057
Demonstration of sub-percent energy resolution in the NEXT-100 detector
NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to $$\sim $$ 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ( $$\beta \beta 0\nu $$ ) of $$ ^{136}\mathrm Xe$$ . The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ( $$Q_{\beta \beta }$$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a $$ ^{228}\textrm{Th}$$ source, demonstrating excellent linear response and an energy resolution of $$(0.90 \pm 0.02)\%$$ FWHM at the $$^{208}$$ Tl photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $$R(Q_{\beta \beta }) = (0.93 \pm 0.02)\%$$ FWHM, confirming the detector’s capability for precision energy measurement in the search for $$\beta \beta 0\nu $$ .- 10 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1057
Open AccessDemonstration of sub-percent energy resolution in the NEXT-100 detector
NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to $$\sim $$ 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ( $$\beta \beta 0\nu $$ ) of $$ ^{136}\mathrm Xe$$ . The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ( $$Q_{\beta \beta }$$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a $$ ^{228}\textrm{Th}$$ source, demonstrating excellent linear response and an energy resolution of $$(0.90 \pm 0.02)\%$$ FWHM at the $$^{208}$$ Tl photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $$R(Q_{\beta \beta }) = (0.93 \pm 0.02)\%$$ FWHM, confirming the detector’s capability for precision energy measurement in the search for $$\beta \beta 0\nu $$ . - Open Access
- 1 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
First results of the NEXT-100 detector using 83mKr decays
The NEXT collaboration is investigating the double beta decay of $$ ^{136}\mathrm Xe$$ using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $$^{83\text {m}}\textrm{Kr}$$ decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $$^{83\text {m}}\textrm{Kr}$$ point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $$E^{-1/2}$$ extrapolation to $$Q_{\beta \beta }$$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.- 1 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
Open AccessFirst results of the NEXT-100 detector using 83mKr decays
The NEXT collaboration is investigating the double beta decay of $$ ^{136}\mathrm Xe$$ using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $$^{83\text {m}}\textrm{Kr}$$ decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $$^{83\text {m}}\textrm{Kr}$$ point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $$E^{-1/2}$$ extrapolation to $$Q_{\beta \beta }$$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target. - Top Cited PapersOpen Access
- 23 February 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (2) , 170
Sensitivity of the Hyper-Kamiokande experiment to neutrino oscillation parameters using accelerator neutrinos
This paper presents the expected sensitivity to the neutrino oscillation parameters of the Hyper-Kamiokande long-baseline program. The Hyper-Kamiokande experiment, currently under construction in Japan, will measure the oscillations of accelerator-produced neutrinos with thousands of selected events per sample: this corresponds to an increase of statistics of a factor 25–100 with respect to recent results from the currently-running long-baseline neutrino oscillation experiment in Japan, T2K. In the most favorable scenario we will achieve the discovery of Charge-Parity (CP) violation in neutrino oscillation at $$5\sigma $$ C.L. in less than 3 years. With 10 years of data-taking, and assuming a neutrino : antineutrino beam running ratio of 1:3, a CP violation discovery at $$5\sigma $$ C.L. is possible for more than 60% of the actual values of the CP-violating phase, $$\delta _{CP}.$$ Moreover, we will measure $$\delta _{CP}$$ with a precision ranging from 20 $$^{\circ },$$ in the case of maximal CP violation, to 6 $$^{\circ },$$ in the case of CP conservation. We aim to achieve a 0.5% resolution on the $$\Delta m^2_{32}$$ parameter, and a resolution between 3% and 0.5% on the $$\sin ^2\theta _{23}$$ parameter, depending on its true value. These results are obtained by extending the analysis methods of T2K with dedicated tuning to take into account the Hyper-Kamiokande design: the larger far detector, the more powerful beam, the upgraded near detector ND280, and the planned additional Intermediate Water Cherenkov Detector.- 23 February 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (2) , 170
Top Cited PapersOpen AccessSensitivity of the Hyper-Kamiokande experiment to neutrino oscillation parameters using accelerator neutrinos
This paper presents the expected sensitivity to the neutrino oscillation parameters of the Hyper-Kamiokande long-baseline program. The Hyper-Kamiokande experiment, currently under construction in Japan, will measure the oscillations of accelerator-produced neutrinos with thousands of selected events per sample: this corresponds to an increase of statistics of a factor 25–100 with respect to recent results from the currently-running long-baseline neutrino oscillation experiment in Japan, T2K. In the most favorable scenario we will achieve the discovery of Charge-Parity (CP) violation in neutrino oscillation at $$5\sigma $$ C.L. in less than 3 years. With 10 years of data-taking, and assuming a neutrino : antineutrino beam running ratio of 1:3, a CP violation discovery at $$5\sigma $$ C.L. is possible for more than 60% of the actual values of the CP-violating phase, $$\delta _{CP}.$$ Moreover, we will measure $$\delta _{CP}$$ with a precision ranging from 20 $$^{\circ },$$ in the case of maximal CP violation, to 6 $$^{\circ },$$ in the case of CP conservation. We aim to achieve a 0.5% resolution on the $$\Delta m^2_{32}$$ parameter, and a resolution between 3% and 0.5% on the $$\sin ^2\theta _{23}$$ parameter, depending on its true value. These results are obtained by extending the analysis methods of T2K with dedicated tuning to take into account the Hyper-Kamiokande design: the larger far detector, the more powerful beam, the upgraded near detector ND280, and the planned additional Intermediate Water Cherenkov Detector. - Top Cited PapersOpen Access
- 5 February 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (2) , 114
The NEXT-100 Detector
The NEXT collaboration is dedicated to the study of double beta decays of $$^{136}$$ Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ( $$\le 1\%$$ FWHM at the $$Q_{\beta \beta }$$ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at $$\sim $$ 4 bar and drift fields of $$74\hbox { V cm}^{-1}$$ and $$118\hbox { V cm}^{-1}$$ , respectively. Alpha decays from the $$^{222}$$ Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.- 5 February 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (2) , 114
Top Cited PapersOpen AccessThe NEXT-100 Detector
The NEXT collaboration is dedicated to the study of double beta decays of $$^{136}$$ Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ( $$\le 1\%$$ FWHM at the $$Q_{\beta \beta }$$ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at $$\sim $$ 4 bar and drift fields of $$74\hbox { V cm}^{-1}$$ and $$118\hbox { V cm}^{-1}$$ , respectively. Alpha decays from the $$^{222}$$ Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget. - Open Access
- 20 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2) , 025001
CRYSP: a total-body PET based on cryogenic cesium iodide crystals
Objective. Total body positron emission tomography (TBPET) scanners have the potential to substantially reduce both acquisition time and administered radiation dose, owing to their high sensitivity. However, their widespread clinical adoption is hindered by the high cost of currently available systems. This work explores the use of pure cesium iodide (CsI) monolithic crystals operated at cryogenic temperatures as a cost-effective alternative to rare-earth scintillators for TBPET. Approach. We investigate the performance of pure CsI crystals operated at cryogenic temperatures (∼100 K), where they achieve a light yield of approximately 10 5 photons/MeV. The implications for energy resolution, spatial resolution (including depth-of-interaction (d.o.i.) capability), and timing performance are assessed, with a view toward their integration into a TBPET system. Main results. Cryogenic CsI crystals demonstrated energy resolution below 7% and coincidence time resolution (CTR) at the nanosecond level, despite their relatively slow scintillation decay time. A Monte Carlo simulation of monolithic CsI crystals shows that a millimeter-scale spatial resolution in all three dimensions can be obtained. These characteristics indicate that high-performance PET imaging is achievable with this technology. Significance. A TBPET scanner based on cryogenic CsI monolithic crystals could combine excellent imaging performance with significantly reduced detector costs, enabling broader accessibility and accelerating the adoption of TBPET in both clinical and research settings.
- 20 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2) , 025001
Open AccessCRYSP: a total-body PET based on cryogenic cesium iodide crystals
Objective. Total body positron emission tomography (TBPET) scanners have the potential to substantially reduce both acquisition time and administered radiation dose, owing to their high sensitivity. However, their widespread clinical adoption is hindered by the high cost of currently available systems. This work explores the use of pure cesium iodide (CsI) monolithic crystals operated at cryogenic temperatures as a cost-effective alternative to rare-earth scintillators for TBPET. Approach. We investigate the performance of pure CsI crystals operated at cryogenic temperatures (∼100 K), where they achieve a light yield of approximately 10 5 photons/MeV. The implications for energy resolution, spatial resolution (including depth-of-interaction (d.o.i.) capability), and timing performance are assessed, with a view toward their integration into a TBPET system. Main results. Cryogenic CsI crystals demonstrated energy resolution below 7% and coincidence time resolution (CTR) at the nanosecond level, despite their relatively slow scintillation decay time. A Monte Carlo simulation of monolithic CsI crystals shows that a millimeter-scale spatial resolution in all three dimensions can be obtained. These characteristics indicate that high-performance PET imaging is achievable with this technology. Significance. A TBPET scanner based on cryogenic CsI monolithic crystals could combine excellent imaging performance with significantly reduced detector costs, enabling broader accessibility and accelerating the adoption of TBPET in both clinical and research settings.
- Open Access
- 28 August 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (8) , 1-9
Performance of an optical TPC Geant4 simulation with opticks GPU-accelerated photon propagation
We investigate the performance of , a 7.5 GPU-accelerated photon propagation tool compared with a single-threaded simulation. We compare the simulations using an improved model of the gaseous time projection chamber. Performance results suggest that improves simulation speeds by between $$58.47\pm {0.02}$$ and $$181.39\pm {0.28}$$ times relative to a CPU-only simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between and .- 28 August 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (8) , 1-9
Open AccessPerformance of an optical TPC Geant4 simulation with opticks GPU-accelerated photon propagation
We investigate the performance of , a 7.5 GPU-accelerated photon propagation tool compared with a single-threaded simulation. We compare the simulations using an improved model of the gaseous time projection chamber. Performance results suggest that improves simulation speeds by between $$58.47\pm {0.02}$$ and $$181.39\pm {0.28}$$ times relative to a CPU-only simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between and . - Open Access
- 15 July 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (7) , 1-22
Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging
A bstract: If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $$ \overline{\cos\ \theta } $$ and $$ \overline{T_1} $$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.- 15 July 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (7) , 1-22
Open AccessReconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging
A bstract: If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $$ \overline{\cos\ \theta } $$ and $$ \overline{T_1} $$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected. - 13 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
Effect of Non-Uniform Contact Resistance in Critical Current Measurements of HTS Roebel Cables
High temperature superconductors can be manufactured in multi-strand configurations such as Roebel and CORC cables. There is very limited modelling examining the inhomogeneities in HTS Roebel cables. Thus a finite element model was developed to analyse the effects of non-uniform contact resistances and current redistribution, when attempting to define the critical current of the cable. Different defects were imposed on a single or pair of neighbouring strands to interrogate the modelled outputs. Types of defect included mimicking a poor contact caused during soldering to the current terminals or varying the inter-strand contact to account for twisting or orientating the cable. The model showed that if poor contact exists between neighbouring strands (tapes); this remains difficult to detect from the electric field data, however, if a poor contact exists at the current terminals, this can be identified, with the individual strand exhibiting voltages several orders lower than in all other strands. Introducing a single strand with low Ic characteristics only had a significant effect unless limited by at least 75%. The model will inform future experiments and can be used as a tool for to define the cable length and location of instrumentation to extract information about the critical current and locating the origins of current sharing.
- 13 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
Effect of Non-Uniform Contact Resistance in Critical Current Measurements of HTS Roebel Cables
High temperature superconductors can be manufactured in multi-strand configurations such as Roebel and CORC cables. There is very limited modelling examining the inhomogeneities in HTS Roebel cables. Thus a finite element model was developed to analyse the effects of non-uniform contact resistances and current redistribution, when attempting to define the critical current of the cable. Different defects were imposed on a single or pair of neighbouring strands to interrogate the modelled outputs. Types of defect included mimicking a poor contact caused during soldering to the current terminals or varying the inter-strand contact to account for twisting or orientating the cable. The model showed that if poor contact exists between neighbouring strands (tapes); this remains difficult to detect from the electric field data, however, if a poor contact exists at the current terminals, this can be identified, with the individual strand exhibiting voltages several orders lower than in all other strands. Introducing a single strand with low Ic characteristics only had a significant effect unless limited by at least 75%. The model will inform future experiments and can be used as a tool for to define the cable length and location of instrumentation to extract information about the critical current and locating the origins of current sharing.
- 1 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
Quench Propagation at Different Conditions in an HTS Pancake Coil Wound With Roebel Cable
The analysis of quench is of paramount importance for the safe operation of any superconducting magnet and this investigation is more relevant, even not fundamental, to prevent damage or burn-out in HTS magnets. Given these premises, quench tests and numerical models are indispensable. A 1D electro-thermal model was developed at the University of Bologna (Italy) and validated versus experimental quench tests performed at the University of Southampton (UK) on a pancake coil wound with REBCO Roebel cable in the frame of the EUCARD- 2 European Project. The analysis here presented investigates quench in the Roebel-based coil in case of a thermal disturbance introduced in the coil. The quench energies measured during tests as a function of the power disturbance are compared with the computed results. The quench energy is furthermore analysed energizing the coil at different transport current. The analysis is further extended to study the quench of the coil at temperatures of 66K and at field of 2T. In the first part of this work, the FEM model is presented. In the second part, the results obtained during the experimental campaign are compared with the numerical ones.
- 1 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
Quench Propagation at Different Conditions in an HTS Pancake Coil Wound With Roebel Cable
The analysis of quench is of paramount importance for the safe operation of any superconducting magnet and this investigation is more relevant, even not fundamental, to prevent damage or burn-out in HTS magnets. Given these premises, quench tests and numerical models are indispensable. A 1D electro-thermal model was developed at the University of Bologna (Italy) and validated versus experimental quench tests performed at the University of Southampton (UK) on a pancake coil wound with REBCO Roebel cable in the frame of the EUCARD- 2 European Project. The analysis here presented investigates quench in the Roebel-based coil in case of a thermal disturbance introduced in the coil. The quench energies measured during tests as a function of the power disturbance are compared with the computed results. The quench energy is furthermore analysed energizing the coil at different transport current. The analysis is further extended to study the quench of the coil at temperatures of 66K and at field of 2T. In the first part of this work, the FEM model is presented. In the second part, the results obtained during the experimental campaign are compared with the numerical ones.