J. Renner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
J. Renner has a total of 787 co-authors. Here are the top co-authors by number of shared publications:
- Josè Juan Gomez Cadenas
Donostia International Physics Center
11 shared publications - Francesco Monrabal
Donostia International Physics Center
10 shared publications - J. A. Hernando Morata
Universidade de Santiago de Compostela
8 shared publications - Jorge Pelegrin
Donostia International Physics Center
8 shared publications - F. J. Mora
Universitat Politècnica de València (UPV), ETSIT
7 shared publications - F. Lopez
Donostia International Physics Center
7 shared publications
Latest Publications
- Open Access
- 19 November 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (11) , 1349
ITACA revisited: ion tracking apparatus with CMOS ASICs
High-pressure xenon gas TPCs with electroluminescent amplification provide detailed topological reconstruction of charged-particle trajectories, offering a distinctive two-electron signature for neutrinoless double beta decay ( $$\beta \beta 0\nu $$ ) searches. We recently proposed ITACA, a detector concept that images both the electron track and the corresponding ion track. While electrons drift rapidly to the anode for standard EL imaging, the positive ions drift slowly to the cathode with millimetre-scale diffusion, allowing time to determine the event energy and barycenter and to position a movable ion detector at the projected arrival point of the ion cloud. We present a conceptual design of the ITACA detector, addressing key feasibility questions. First, we define the detector geometry and operating parameters for a 1-tonne-scale instrument at 15 bar, including a modular tiled electroluminescent structure. Second, we present the conceptual design of the Magnetically Actuated Rotor System (MARS), the mechanism that positions the ion sensor at any coordinate below the cathode, and show that the expected movement time is fast enough to retain $$\sim 93\%$$ of the drift volume for ion detection, while not significantly perturbing the gas on the scales of the ion drift. Third, we propose using a Topmetal CMOS ASIC-based ion detector, enabling real-time, 3D imaging of the ion track without the need for offline laser scanning. Finally, we estimate the sensitivity of the proposed apparatus, showing that enhanced topological discrimination from the ion track, combined with an ultra-low background design, allows exploration of $$\beta \beta 0\nu $$ half-lives in excess of $$10^{28}$$ yr.- 19 November 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (11) , 1349
Open AccessITACA revisited: ion tracking apparatus with CMOS ASICs
High-pressure xenon gas TPCs with electroluminescent amplification provide detailed topological reconstruction of charged-particle trajectories, offering a distinctive two-electron signature for neutrinoless double beta decay ( $$\beta \beta 0\nu $$ ) searches. We recently proposed ITACA, a detector concept that images both the electron track and the corresponding ion track. While electrons drift rapidly to the anode for standard EL imaging, the positive ions drift slowly to the cathode with millimetre-scale diffusion, allowing time to determine the event energy and barycenter and to position a movable ion detector at the projected arrival point of the ion cloud. We present a conceptual design of the ITACA detector, addressing key feasibility questions. First, we define the detector geometry and operating parameters for a 1-tonne-scale instrument at 15 bar, including a modular tiled electroluminescent structure. Second, we present the conceptual design of the Magnetically Actuated Rotor System (MARS), the mechanism that positions the ion sensor at any coordinate below the cathode, and show that the expected movement time is fast enough to retain $$\sim 93\%$$ of the drift volume for ion detection, while not significantly perturbing the gas on the scales of the ion drift. Third, we propose using a Topmetal CMOS ASIC-based ion detector, enabling real-time, 3D imaging of the ion track without the need for offline laser scanning. Finally, we estimate the sensitivity of the proposed apparatus, showing that enhanced topological discrimination from the ion track, combined with an ultra-low background design, allows exploration of $$\beta \beta 0\nu $$ half-lives in excess of $$10^{28}$$ yr. - Open Access
- 17 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1066
Publisher Correction: Sensitivity of the Hyper-Kamiokande experiment to neutrino oscillation parameters using accelerator neutrinos
- 17 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1066
Open AccessPublisher Correction: Sensitivity of the Hyper-Kamiokande experiment to neutrino oscillation parameters using accelerator neutrinos
- Open Access
- 10 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1057
Demonstration of sub-percent energy resolution in the NEXT-100 detector
NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to $$\sim $$ 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ( $$\beta \beta 0\nu $$ ) of $$ ^{136}\mathrm Xe$$ . The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ( $$Q_{\beta \beta }$$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a $$ ^{228}\textrm{Th}$$ source, demonstrating excellent linear response and an energy resolution of $$(0.90 \pm 0.02)\%$$ FWHM at the $$^{208}$$ Tl photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $$R(Q_{\beta \beta }) = (0.93 \pm 0.02)\%$$ FWHM, confirming the detector’s capability for precision energy measurement in the search for $$\beta \beta 0\nu $$ .- 10 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1057
Open AccessDemonstration of sub-percent energy resolution in the NEXT-100 detector
NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to $$\sim $$ 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ( $$\beta \beta 0\nu $$ ) of $$ ^{136}\mathrm Xe$$ . The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ( $$Q_{\beta \beta }$$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a $$ ^{228}\textrm{Th}$$ source, demonstrating excellent linear response and an energy resolution of $$(0.90 \pm 0.02)\%$$ FWHM at the $$^{208}$$ Tl photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $$R(Q_{\beta \beta }) = (0.93 \pm 0.02)\%$$ FWHM, confirming the detector’s capability for precision energy measurement in the search for $$\beta \beta 0\nu $$ . - Open Access
- 1 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
First results of the NEXT-100 detector using 83mKr decays
The NEXT collaboration is investigating the double beta decay of $$ ^{136}\mathrm Xe$$ using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $$^{83\text {m}}\textrm{Kr}$$ decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $$^{83\text {m}}\textrm{Kr}$$ point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $$E^{-1/2}$$ extrapolation to $$Q_{\beta \beta }$$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.- 1 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
Open AccessFirst results of the NEXT-100 detector using 83mKr decays
The NEXT collaboration is investigating the double beta decay of $$ ^{136}\mathrm Xe$$ using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $$^{83\text {m}}\textrm{Kr}$$ decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $$^{83\text {m}}\textrm{Kr}$$ point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $$E^{-1/2}$$ extrapolation to $$Q_{\beta \beta }$$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target. - Open Access
- 31 March 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (3)
A journey to ITACA
A unique feature of gas xenon electroluminescent time projection chambers (GXeEL TPCs) in $$\beta \beta 0\nu $$ searches is their ability to reconstruct event topology, in particular to distinguish “single-electron” from “double-electron” tracks, the latter being the signature of a $$\beta \beta 0\nu $$ decay near the decay endpoint $$Q_{\beta \beta }$$ . Together with excellent energy resolution and the t $$_0$$ provided by primary scintillation, this topological information is key to suppressing backgrounds. Preserving EL, however, requires operation in pure xenon (with helium as the only benign additive), where electron diffusion is large. Consequently, reconstructed track fidelity is limited by diffusion and intrinsic EL blurring. We propose augmenting the detector with the ability to image not only the electron track but also the corresponding mirror ion track. Introducing trace amounts of $$\mathrm{NH_3}$$ ( $$\sim $$ 100 ppb) converts primary xenon ions into ammonium ions, $$\mathrm{NH_4^{+}}$$ , via a fast two-step ion–molecule process involving charge transfer followed by proton transfer, while leaving EL unaffected. Electrons drift rapidly to the anode, producing the standard EL image, whereas $$\mathrm{NH_4^{+}}$$ ions drift slowly toward the cathode, allowing time to determine the event energy and barycenter. For events in the region of interest, an ion sensor near the cathode at the projected barycenter captures the ions. Laser interrogation of the sensor’s molecular layer then reveals an ion-track image with sub-millimeter diffusion and no EL-induced smearing. Combined electron–ion imaging strengthens topological discrimination, improving background rejection by about an order of magnitude and significantly extending the discovery potential of GXeEL TPCs for very long $$\beta \beta 0\nu $$ lifetimes.- 31 March 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (3)
Open AccessA journey to ITACA
A unique feature of gas xenon electroluminescent time projection chambers (GXeEL TPCs) in $$\beta \beta 0\nu $$ searches is their ability to reconstruct event topology, in particular to distinguish “single-electron” from “double-electron” tracks, the latter being the signature of a $$\beta \beta 0\nu $$ decay near the decay endpoint $$Q_{\beta \beta }$$ . Together with excellent energy resolution and the t $$_0$$ provided by primary scintillation, this topological information is key to suppressing backgrounds. Preserving EL, however, requires operation in pure xenon (with helium as the only benign additive), where electron diffusion is large. Consequently, reconstructed track fidelity is limited by diffusion and intrinsic EL blurring. We propose augmenting the detector with the ability to image not only the electron track but also the corresponding mirror ion track. Introducing trace amounts of $$\mathrm{NH_3}$$ ( $$\sim $$ 100 ppb) converts primary xenon ions into ammonium ions, $$\mathrm{NH_4^{+}}$$ , via a fast two-step ion–molecule process involving charge transfer followed by proton transfer, while leaving EL unaffected. Electrons drift rapidly to the anode, producing the standard EL image, whereas $$\mathrm{NH_4^{+}}$$ ions drift slowly toward the cathode, allowing time to determine the event energy and barycenter. For events in the region of interest, an ion sensor near the cathode at the projected barycenter captures the ions. Laser interrogation of the sensor’s molecular layer then reveals an ion-track image with sub-millimeter diffusion and no EL-induced smearing. Combined electron–ion imaging strengthens topological discrimination, improving background rejection by about an order of magnitude and significantly extending the discovery potential of GXeEL TPCs for very long $$\beta \beta 0\nu $$ lifetimes. - Top Cited PapersOpen Access
- 23 February 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (2) , 170
Sensitivity of the Hyper-Kamiokande experiment to neutrino oscillation parameters using accelerator neutrinos
This paper presents the expected sensitivity to the neutrino oscillation parameters of the Hyper-Kamiokande long-baseline program. The Hyper-Kamiokande experiment, currently under construction in Japan, will measure the oscillations of accelerator-produced neutrinos with thousands of selected events per sample: this corresponds to an increase of statistics of a factor 25–100 with respect to recent results from the currently-running long-baseline neutrino oscillation experiment in Japan, T2K. In the most favorable scenario we will achieve the discovery of Charge-Parity (CP) violation in neutrino oscillation at $$5\sigma $$ C.L. in less than 3 years. With 10 years of data-taking, and assuming a neutrino : antineutrino beam running ratio of 1:3, a CP violation discovery at $$5\sigma $$ C.L. is possible for more than 60% of the actual values of the CP-violating phase, $$\delta _{CP}.$$ Moreover, we will measure $$\delta _{CP}$$ with a precision ranging from 20 $$^{\circ },$$ in the case of maximal CP violation, to 6 $$^{\circ },$$ in the case of CP conservation. We aim to achieve a 0.5% resolution on the $$\Delta m^2_{32}$$ parameter, and a resolution between 3% and 0.5% on the $$\sin ^2\theta _{23}$$ parameter, depending on its true value. These results are obtained by extending the analysis methods of T2K with dedicated tuning to take into account the Hyper-Kamiokande design: the larger far detector, the more powerful beam, the upgraded near detector ND280, and the planned additional Intermediate Water Cherenkov Detector.- 23 February 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (2) , 170
Top Cited PapersOpen AccessSensitivity of the Hyper-Kamiokande experiment to neutrino oscillation parameters using accelerator neutrinos
This paper presents the expected sensitivity to the neutrino oscillation parameters of the Hyper-Kamiokande long-baseline program. The Hyper-Kamiokande experiment, currently under construction in Japan, will measure the oscillations of accelerator-produced neutrinos with thousands of selected events per sample: this corresponds to an increase of statistics of a factor 25–100 with respect to recent results from the currently-running long-baseline neutrino oscillation experiment in Japan, T2K. In the most favorable scenario we will achieve the discovery of Charge-Parity (CP) violation in neutrino oscillation at $$5\sigma $$ C.L. in less than 3 years. With 10 years of data-taking, and assuming a neutrino : antineutrino beam running ratio of 1:3, a CP violation discovery at $$5\sigma $$ C.L. is possible for more than 60% of the actual values of the CP-violating phase, $$\delta _{CP}.$$ Moreover, we will measure $$\delta _{CP}$$ with a precision ranging from 20 $$^{\circ },$$ in the case of maximal CP violation, to 6 $$^{\circ },$$ in the case of CP conservation. We aim to achieve a 0.5% resolution on the $$\Delta m^2_{32}$$ parameter, and a resolution between 3% and 0.5% on the $$\sin ^2\theta _{23}$$ parameter, depending on its true value. These results are obtained by extending the analysis methods of T2K with dedicated tuning to take into account the Hyper-Kamiokande design: the larger far detector, the more powerful beam, the upgraded near detector ND280, and the planned additional Intermediate Water Cherenkov Detector. - Top Cited PapersOpen Access
- 5 February 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (2) , 114
The NEXT-100 Detector
The NEXT collaboration is dedicated to the study of double beta decays of $$^{136}$$ Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ( $$\le 1\%$$ FWHM at the $$Q_{\beta \beta }$$ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at $$\sim $$ 4 bar and drift fields of $$74\hbox { V cm}^{-1}$$ and $$118\hbox { V cm}^{-1}$$ , respectively. Alpha decays from the $$^{222}$$ Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.- 5 February 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (2) , 114
Top Cited PapersOpen AccessThe NEXT-100 Detector
The NEXT collaboration is dedicated to the study of double beta decays of $$^{136}$$ Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ( $$\le 1\%$$ FWHM at the $$Q_{\beta \beta }$$ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at $$\sim $$ 4 bar and drift fields of $$74\hbox { V cm}^{-1}$$ and $$118\hbox { V cm}^{-1}$$ , respectively. Alpha decays from the $$^{222}$$ Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget. - Open Access
- 20 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2) , 025001
CRYSP: a total-body PET based on cryogenic cesium iodide crystals
Objective. Total body positron emission tomography (TBPET) scanners have the potential to substantially reduce both acquisition time and administered radiation dose, owing to their high sensitivity. However, their widespread clinical adoption is hindered by the high cost of currently available systems. This work explores the use of pure cesium iodide (CsI) monolithic crystals operated at cryogenic temperatures as a cost-effective alternative to rare-earth scintillators for TBPET. Approach. We investigate the performance of pure CsI crystals operated at cryogenic temperatures (∼100 K), where they achieve a light yield of approximately 10 5 photons/MeV. The implications for energy resolution, spatial resolution (including depth-of-interaction (d.o.i.) capability), and timing performance are assessed, with a view toward their integration into a TBPET system. Main results. Cryogenic CsI crystals demonstrated energy resolution below 7% and coincidence time resolution (CTR) at the nanosecond level, despite their relatively slow scintillation decay time. A Monte Carlo simulation of monolithic CsI crystals shows that a millimeter-scale spatial resolution in all three dimensions can be obtained. These characteristics indicate that high-performance PET imaging is achievable with this technology. Significance. A TBPET scanner based on cryogenic CsI monolithic crystals could combine excellent imaging performance with significantly reduced detector costs, enabling broader accessibility and accelerating the adoption of TBPET in both clinical and research settings.
- 20 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2) , 025001
Open AccessCRYSP: a total-body PET based on cryogenic cesium iodide crystals
Objective. Total body positron emission tomography (TBPET) scanners have the potential to substantially reduce both acquisition time and administered radiation dose, owing to their high sensitivity. However, their widespread clinical adoption is hindered by the high cost of currently available systems. This work explores the use of pure cesium iodide (CsI) monolithic crystals operated at cryogenic temperatures as a cost-effective alternative to rare-earth scintillators for TBPET. Approach. We investigate the performance of pure CsI crystals operated at cryogenic temperatures (∼100 K), where they achieve a light yield of approximately 10 5 photons/MeV. The implications for energy resolution, spatial resolution (including depth-of-interaction (d.o.i.) capability), and timing performance are assessed, with a view toward their integration into a TBPET system. Main results. Cryogenic CsI crystals demonstrated energy resolution below 7% and coincidence time resolution (CTR) at the nanosecond level, despite their relatively slow scintillation decay time. A Monte Carlo simulation of monolithic CsI crystals shows that a millimeter-scale spatial resolution in all three dimensions can be obtained. These characteristics indicate that high-performance PET imaging is achievable with this technology. Significance. A TBPET scanner based on cryogenic CsI monolithic crystals could combine excellent imaging performance with significantly reduced detector costs, enabling broader accessibility and accelerating the adoption of TBPET in both clinical and research settings.
- Open Access
- 28 August 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (8) , 1-9
Performance of an optical TPC Geant4 simulation with opticks GPU-accelerated photon propagation
We investigate the performance of , a 7.5 GPU-accelerated photon propagation tool compared with a single-threaded simulation. We compare the simulations using an improved model of the gaseous time projection chamber. Performance results suggest that improves simulation speeds by between $$58.47\pm {0.02}$$ and $$181.39\pm {0.28}$$ times relative to a CPU-only simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between and .- 28 August 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (8) , 1-9
Open AccessPerformance of an optical TPC Geant4 simulation with opticks GPU-accelerated photon propagation
We investigate the performance of , a 7.5 GPU-accelerated photon propagation tool compared with a single-threaded simulation. We compare the simulations using an improved model of the gaseous time projection chamber. Performance results suggest that improves simulation speeds by between $$58.47\pm {0.02}$$ and $$181.39\pm {0.28}$$ times relative to a CPU-only simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between and . - Open Access
- 15 July 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (7) , 1-22
Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging
A bstract: If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $$ \overline{\cos\ \theta } $$ and $$ \overline{T_1} $$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.- 15 July 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (7) , 1-22
Open AccessReconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging
A bstract: If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $$ \overline{\cos\ \theta } $$ and $$ \overline{T_1} $$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.