Alexander Deisting
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alexander Deisting has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Uwe Oberlack
Institut für Physik and Exzellenzcluster PRISMA+, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany
18 shared publications - Daniel Wenz
Institut für Kernphysik, University of Münster, 48149 Münster, Germany
17 shared publications - A. Elykov
Institute for Astroparticle Physics, Karlsruhe Institute of Technology, 76021 Karlsruhe, Germany
16 shared publications - Julia Müller
Physikalisches Institut, Universität Freiburg, 79104 Freiburg, Germany
16 shared publications - Kathrin Valerius
Institute for Astroparticle Physics, Karlsruhe Institute of Technology, 76021 Karlsruhe, Germany
16 shared publications - Klaus Eitel
Institute for Astroparticle Physics, Karlsruhe Institute of Technology, 76021 Karlsruhe, Germany
16 shared publications
Latest Publications
- Open Access
- 14 September 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (12) , 121001
Constraints on Solar Reflected Dark Matter from XENON1T and XENONnT Data
We report on a search for sub-GeV dark matter upscattered via the solar reflection mechanism in the heavy mediator scenario. Under the standard halo model, keV–MeV dark matter produces nuclear recoils with energies below the detection threshold of liquid xenon time projection chambers. We enhance sensitivity to low-mass dark matter (DM) by considering dark matter–electron scattering, employing dedicated event selections to reduce the detection threshold and exploiting the additional kinetic energy imparted to the dark matter particle by solar upscattering. Using XENON1T ionization-only and XENONnT low-energy electronic recoil datasets, we exclude previously unconstrained DM-electron scattering cross section for masses between 4.6 and 20 keV / c 2 and between 0.2 and 2 MeV / c 2 , reaching a minimum of 3.41 × 10 − 39 cm 2 for a mass of 0.3 MeV / c 2 at 90% confidence level.
- 14 September 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (12) , 121001
Open AccessConstraints on Solar Reflected Dark Matter from XENON1T and XENONnT Data
We report on a search for sub-GeV dark matter upscattered via the solar reflection mechanism in the heavy mediator scenario. Under the standard halo model, keV–MeV dark matter produces nuclear recoils with energies below the detection threshold of liquid xenon time projection chambers. We enhance sensitivity to low-mass dark matter (DM) by considering dark matter–electron scattering, employing dedicated event selections to reduce the detection threshold and exploiting the additional kinetic energy imparted to the dark matter particle by solar upscattering. Using XENON1T ionization-only and XENONnT low-energy electronic recoil datasets, we exclude previously unconstrained DM-electron scattering cross section for masses between 4.6 and 20 keV / c 2 and between 0.2 and 2 MeV / c 2 , reaching a minimum of 3.41 × 10 − 39 cm 2 for a mass of 0.3 MeV / c 2 at 90% confidence level.
- Open Access
- 28 August 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (9) , 091807
Probing the Solar B 8 Neutrino Fog with XENONnT
We report a 3.3 σ measurement of coherent elastic neutrino-nucleus scattering from solar B 8 neutrinos using a 6.77 t × yr exposure from the XENONnT experiment, inferring a solar B 8 neutrino flux of ( 5 − 2 + 3 ) × 10 6 cm − 2 s − 1 , consistent with previous measurements. In the presence of the B 8 “neutrino fog,” we find no evidence for light dark matter, and observe diminishing returns in sensitivity with increasing exposure. A 93% increase in exposure from the previous search improves the median sensitivity to the nucleon scattering cross section for a 5 GeV / c 2 spin-independent weakly interacting massive particle by 10%. The dataset was also used to measure the weak mixing angle at ∼ 0.02 GeV / c momentum transfer and constrain physics beyond the Standard Model.
- 28 August 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 137 (9) , 091807
Open AccessProbing the Solar B 8 Neutrino Fog with XENONnT
We report a 3.3 σ measurement of coherent elastic neutrino-nucleus scattering from solar B 8 neutrinos using a 6.77 t × yr exposure from the XENONnT experiment, inferring a solar B 8 neutrino flux of ( 5 − 2 + 3 ) × 10 6 cm − 2 s − 1 , consistent with previous measurements. In the presence of the B 8 “neutrino fog,” we find no evidence for light dark matter, and observe diminishing returns in sensitivity with increasing exposure. A 93% increase in exposure from the previous search improves the median sensitivity to the nucleon scattering cross section for a 5 GeV / c 2 spin-independent weakly interacting massive particle by 10%. The dataset was also used to measure the weak mixing angle at ∼ 0.02 GeV / c momentum transfer and constrain physics beyond the Standard Model.
- Open Access
- 29 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (11)
Low-energy nuclear recoil calibration of XENONnT with a Y 88 Be photoneutron source
Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used an Yttrium-Beryllium photoneutron source that emits 152 keV neutrons for the calibration of the light and charge yields of the XENONnT experiment for the first time. After data selection, we accumulated 474 events from 183 hours of exposure with this source. The expected background was 55 ± 12 accidental coincidence events, estimated using a dedicated 152 hour background calibration run with a Yttrium-PVC gamma-only source and data-driven modeling. From these calibrations, we extracted the light (charge) yield for liquid xenon at our field strength of 23 V / cm between 0.3 (0.7) keV NR and 5.0 keV NR . This calibration is crucial for accurately measuring the solar B 8 neutrino coherent elastic neutrino-nucleus scattering and searching for light dark matter particles with masses below 12 GeV / c 2 .
- 29 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (11)
Open AccessLow-energy nuclear recoil calibration of XENONnT with a Y 88 Be photoneutron source
Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used an Yttrium-Beryllium photoneutron source that emits 152 keV neutrons for the calibration of the light and charge yields of the XENONnT experiment for the first time. After data selection, we accumulated 474 events from 183 hours of exposure with this source. The expected background was 55 ± 12 accidental coincidence events, estimated using a dedicated 152 hour background calibration run with a Yttrium-PVC gamma-only source and data-driven modeling. From these calibrations, we extracted the light (charge) yield for liquid xenon at our field strength of 23 V / cm between 0.3 (0.7) keV NR and 5.0 keV NR . This calibration is crucial for accurately measuring the solar B 8 neutrino coherent elastic neutrino-nucleus scattering and searching for light dark matter particles with masses below 12 GeV / c 2 .
- Open Access
- 23 March 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (12) , 120201
Challenging Spontaneous Quantum Collapse with the XENONnT Dark Matter Detector
We report on the search for x-ray radiation as predicted from dynamical quantum collapse with low-energy electronic recoil data in the energy range of 1–140 keV from the first science run of the XENONnT dark matter detector. Spontaneous radiation is an unavoidable effect of dynamical collapse models, which were introduced as a possible solution to the long-standing measurement problem in quantum mechanics. The analysis utilizes a model that for the first time accounts for cancellation effects in the emitted spectrum, which arise in the x-ray range due to the opposing electron-proton charges in xenon atoms. New world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Diósi-Penrose models are set, improving previous best constraints by two orders of magnitude and a factor of five, respectively. For the strength and correlation length of the continuous spontaneous localization model, values in the originally proposed parameter ranges are experimentally excluded for the first time.
- 23 March 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (12) , 120201
Open AccessChallenging Spontaneous Quantum Collapse with the XENONnT Dark Matter Detector
We report on the search for x-ray radiation as predicted from dynamical quantum collapse with low-energy electronic recoil data in the energy range of 1–140 keV from the first science run of the XENONnT dark matter detector. Spontaneous radiation is an unavoidable effect of dynamical collapse models, which were introduced as a possible solution to the long-standing measurement problem in quantum mechanics. The analysis utilizes a model that for the first time accounts for cancellation effects in the emitted spectrum, which arise in the x-ray range due to the opposing electron-proton charges in xenon atoms. New world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Diósi-Penrose models are set, improving previous best constraints by two orders of magnitude and a factor of five, respectively. For the strength and correlation length of the continuous spontaneous localization model, values in the originally proposed parameter ranges are experimentally excluded for the first time.
- Open Access
- 1 February 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (02) , P02035
Development & characterization of electrodes for large-scale Xenon Time Projection Chambers
Dual-phase liquid xenon time projection chambers are the core detector elements of many experiments that conduct searches for Dark Matter and rare events, as well as in neutrino and high-energy physics. As part of this detector technology, high-voltage electrodes are instrumental for the generation of observable signals and their physical interpretation. Thus, electrode design and manufacturing has to fulfill stringent requirements, and their production is associated with significant engineering challenges. In this work we describe the successful development of electrodes on the 1.5 m-scale, from their design and simulation to subsequent assembly and high-voltage testing in a gaseous argon environment. The produced electrodes were recently installed as an anode and a cathode during an upgrade to the XENONnT experiment.
- 1 February 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (02) , P02035
Open AccessDevelopment & characterization of electrodes for large-scale Xenon Time Projection Chambers
Dual-phase liquid xenon time projection chambers are the core detector elements of many experiments that conduct searches for Dark Matter and rare events, as well as in neutrino and high-energy physics. As part of this detector technology, high-voltage electrodes are instrumental for the generation of observable signals and their physical interpretation. Thus, electrode design and manufacturing has to fulfill stringent requirements, and their production is associated with significant engineering challenges. In this work we describe the successful development of electrodes on the 1.5 m-scale, from their design and simulation to subsequent assembly and high-voltage testing in a gaseous argon environment. The produced electrodes were recently installed as an anode and a cathode during an upgrade to the XENONnT experiment.
- Open Access
Light Dark Matter Search with 7.8 Tonne-Year of Ionization-Only Data in XENONnT
We report on a blinded search for dark matter (DM) using ionization-only (S2-only) signals in XENONnT with a total exposure of $7.83\mathrm{tonne}\times\mathrm{year}$ over 579 days in three science runs. Dedicated background suppression techniques and the first complete S2-only background model in XENONnT provide sensitivity to nuclear recoils of [0.5, 5.0] $\mathrm{keV_\mathrm{nr}}$ and electronic recoils of [0.04, 0.7] $\mathrm{keV_\mathrm{ee}}$. No significant excess over the expected background is observed, and we set 90\% confidence level upper limits on spin-independent DM--nucleon and spin-dependent DM--neutron scattering for DM masses between 3 and 8 $\mathrm{GeV}/c^2$, as well as on DM--electron scattering, axion-like particles, and dark photons, improving on previous constraints. For spin-independent DM--nucleon scattering, we exclude cross sections above $6.0\times10^{-45} $cm$^2$ at a DM mass of 5 $\mathrm{GeV}/c^2$, pushing the XENONnT sensitivity closer to the region where coherent elastic neutrino-nucleus scattering ($\text{CE}ν\text{NS}$) becomes an irreducible background.Open AccessLight Dark Matter Search with 7.8 Tonne-Year of Ionization-Only Data in XENONnT
We report on a blinded search for dark matter (DM) using ionization-only (S2-only) signals in XENONnT with a total exposure of $7.83\mathrm{tonne}\times\mathrm{year}$ over 579 days in three science runs. Dedicated background suppression techniques and the first complete S2-only background model in XENONnT provide sensitivity to nuclear recoils of [0.5, 5.0] $\mathrm{keV_\mathrm{nr}}$ and electronic recoils of [0.04, 0.7] $\mathrm{keV_\mathrm{ee}}$. No significant excess over the expected background is observed, and we set 90\% confidence level upper limits on spin-independent DM--nucleon and spin-dependent DM--neutron scattering for DM masses between 3 and 8 $\mathrm{GeV}/c^2$, as well as on DM--electron scattering, axion-like particles, and dark photons, improving on previous constraints. For spin-independent DM--nucleon scattering, we exclude cross sections above $6.0\times10^{-45} $cm$^2$ at a DM mass of 5 $\mathrm{GeV}/c^2$, pushing the XENONnT sensitivity closer to the region where coherent elastic neutrino-nucleus scattering ($\text{CE}ν\text{NS}$) becomes an irreducible background. - 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , P01034
GRANITE: high-resolution imaging and electrical qualification of large-area TPC electrodes
Next-generation dual-phase time projection chambers (TPCs) for rare event searches will require large-scale, high-precision electrodes. To meet the stringent requirements for high-voltage performance of such an experiment, we have developed a scanning setup for comprehensive electrode quality assurance. The system is built around the GRANITE (Granular Robotic Assay for Novel Integrated TPC Electrodes) facility: a gantry robot on top of a 2.5 m× 1.8 m granite table, equipped with a suite of non-contact metrology devices. We developed a coaxial wire scanning head to measure and correlate localized high-voltage discharge currents in air with high-resolution surface images. We find that the identified discharge `hotspots' are transient and show no significant correlation with static visual features. Next, we established a quantitative relationship between artificially induced abrasive surface damage on the wires and a reduction in the discharge inception voltage. This work provides a novel non-invasive tool for qualifying wires dedicated for use in electrodes for future low-background experiments.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , P01034
GRANITE: high-resolution imaging and electrical qualification of large-area TPC electrodes
Next-generation dual-phase time projection chambers (TPCs) for rare event searches will require large-scale, high-precision electrodes. To meet the stringent requirements for high-voltage performance of such an experiment, we have developed a scanning setup for comprehensive electrode quality assurance. The system is built around the GRANITE (Granular Robotic Assay for Novel Integrated TPC Electrodes) facility: a gantry robot on top of a 2.5 m× 1.8 m granite table, equipped with a suite of non-contact metrology devices. We developed a coaxial wire scanning head to measure and correlate localized high-voltage discharge currents in air with high-resolution surface images. We find that the identified discharge `hotspots' are transient and show no significant correlation with static visual features. Next, we established a quantitative relationship between artificially induced abrasive surface damage on the wires and a reduction in the discharge inception voltage. This work provides a novel non-invasive tool for qualifying wires dedicated for use in electrodes for future low-background experiments.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , P01033
GRANITE: mechanical characterization and optical inspection of large-area TPC electrodes
Next-generation dual-phase time projection chambers (TPCs) for rare event searches will require large-scale, high-precision electrodes. To meet the stringent requirements for mechanical stability and high-voltage performance of such an experiment, we have developed a scanning setup for comprehensive electrode quality assurance called GRANITE: Granular Robotic Assay for Novel Integrated TPC Electrodes. GRANITE is built around a gantry robot on top of a 2.5 × 1.8 m granite table, equipped with a suite of non-contact metrology devices. We demonstrate the setup's capabilities in two key areas: first, using laser scanners, we characterize wire tension, and in an independent measurement wire deflection due to gravity and electrostatic forces is determined. The setup achieves a precision of 20 μm for the relative measurement of only electrostatic displacement. Furthermore, GRANITE can measure gravitational sag down to 200 μm in an absolute measurement; this precision improves to 50 μm when applying model-based corrections for systematic effects. The performance achieved exceeds the needs for the characterisation of the electrode sagging in future experiments, which typically aims to ensure a maximal sag on the order of 500 μm. Second, we use GRANITE's high resolution camera to image every wire of the cathode grid of the XENON1T experiment. Subsets of these images are then hand sorted and used to train an autoencoder, to reliably classify wire images as either pristine wires or images containing severe anomalous features. These anomalies appear e.g. as staining and may be potential defects. The interpretation of the classification results is complicated by the fact that most wire segments are not spotless, but show a varying amount of anomalous features. Follow-up studies are needed to identify the exact nature of such features on wires and if they cause effects (e.g. field emission) which would prohibit the deployment of the corresponding wire as part of an electrode in a future dual-phase TPC.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , P01033
GRANITE: mechanical characterization and optical inspection of large-area TPC electrodes
Next-generation dual-phase time projection chambers (TPCs) for rare event searches will require large-scale, high-precision electrodes. To meet the stringent requirements for mechanical stability and high-voltage performance of such an experiment, we have developed a scanning setup for comprehensive electrode quality assurance called GRANITE: Granular Robotic Assay for Novel Integrated TPC Electrodes. GRANITE is built around a gantry robot on top of a 2.5 × 1.8 m granite table, equipped with a suite of non-contact metrology devices. We demonstrate the setup's capabilities in two key areas: first, using laser scanners, we characterize wire tension, and in an independent measurement wire deflection due to gravity and electrostatic forces is determined. The setup achieves a precision of 20 μm for the relative measurement of only electrostatic displacement. Furthermore, GRANITE can measure gravitational sag down to 200 μm in an absolute measurement; this precision improves to 50 μm when applying model-based corrections for systematic effects. The performance achieved exceeds the needs for the characterisation of the electrode sagging in future experiments, which typically aims to ensure a maximal sag on the order of 500 μm. Second, we use GRANITE's high resolution camera to image every wire of the cathode grid of the XENON1T experiment. Subsets of these images are then hand sorted and used to train an autoencoder, to reliably classify wire images as either pristine wires or images containing severe anomalous features. These anomalies appear e.g. as staining and may be potential defects. The interpretation of the classification results is complicated by the fact that most wire segments are not spotless, but show a varying amount of anomalous features. Follow-up studies are needed to identify the exact nature of such features on wires and if they cause effects (e.g. field emission) which would prohibit the deployment of the corresponding wire as part of an electrode in a future dual-phase TPC.
- Open Access
Constraints on Solar Reflected Dark Matter from a combined analysis of XENON1T and XENONnT data
We report on a search for sub-GeV dark matter upscattered via the solar reflection mechanism in the heavy mediator scenario. Under the Standard Halo Model, keV to MeV dark matter produces nuclear recoils with energies below the detection threshold of liquid xenon time projection chambers. We enhance sensitivity to low-mass dark matter by considering dark matter-electron scattering, employing dedicated event selections to reduce the detection threshold, and exploiting the additional kinetic energy imparted to the dark matter particle by solar upscattering. Using XENON1T ionization-only and XENONnT low-energy electronic recoil datasets, we exclude previously unconstrained DM-electron scattering cross section for masses between $4.6\, \text{keV/}c^2$ and $20\, \text{keV/}c^2$, and between $0.2\, \text{MeV/}c^2$ and $2\, \text{MeV/}c^2$, reaching a minimum of $3.41\times10^{-39}\, \text{cm}^2$ for a mass of $0.3\, \text{MeV/}c^2$ at 90\% confidence level.Open AccessConstraints on Solar Reflected Dark Matter from a combined analysis of XENON1T and XENONnT data
We report on a search for sub-GeV dark matter upscattered via the solar reflection mechanism in the heavy mediator scenario. Under the Standard Halo Model, keV to MeV dark matter produces nuclear recoils with energies below the detection threshold of liquid xenon time projection chambers. We enhance sensitivity to low-mass dark matter by considering dark matter-electron scattering, employing dedicated event selections to reduce the detection threshold, and exploiting the additional kinetic energy imparted to the dark matter particle by solar upscattering. Using XENON1T ionization-only and XENONnT low-energy electronic recoil datasets, we exclude previously unconstrained DM-electron scattering cross section for masses between $4.6\, \text{keV/}c^2$ and $20\, \text{keV/}c^2$, and between $0.2\, \text{MeV/}c^2$ and $2\, \text{MeV/}c^2$, reaching a minimum of $3.41\times10^{-39}\, \text{cm}^2$ for a mass of $0.3\, \text{MeV/}c^2$ at 90\% confidence level. - Top Cited PapersOpen Access
- 24 November 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (22) , 221003
WIMP Dark Matter Search Using a 3.1 Tonne-Year Exposure of the XENONnT Experiment
We report on a search for weakly interacting massive particle (WIMP) dark matter (DM) via elastic DM-xenon-nucleus interactions in the XENONnT experiment. We combine datasets from the first and second science campaigns resulting in a total exposure of 3.1 tonne-years. In a blind analysis of nuclear recoil events with energies above 3.8 keV NR , we find no significant excess above background. We set new upper limits on the spin-independent WIMP-nucleon scattering cross section for WIMP masses above 10 GeV / c 2 with a minimum of 1.7 × 10 − 47 cm 2 at 90% confidence level for a WIMP mass of 30 GeV / c 2 . We achieve a best median sensitivity of 1.4 × 10 − 47 cm 2 for a 41 GeV / c 2 WIMP. Compared to the result from the first XENONnT science dataset, we improve our sensitivity by a factor of up to 1.8.
- 24 November 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (22) , 221003
Top Cited PapersOpen AccessWIMP Dark Matter Search Using a 3.1 Tonne-Year Exposure of the XENONnT Experiment
We report on a search for weakly interacting massive particle (WIMP) dark matter (DM) via elastic DM-xenon-nucleus interactions in the XENONnT experiment. We combine datasets from the first and second science campaigns resulting in a total exposure of 3.1 tonne-years. In a blind analysis of nuclear recoil events with energies above 3.8 keV NR , we find no significant excess above background. We set new upper limits on the spin-independent WIMP-nucleon scattering cross section for WIMP masses above 10 GeV / c 2 with a minimum of 1.7 × 10 − 47 cm 2 at 90% confidence level for a WIMP mass of 30 GeV / c 2 . We achieve a best median sensitivity of 1.4 × 10 − 47 cm 2 for a 41 GeV / c 2 WIMP. Compared to the result from the first XENONnT science dataset, we improve our sensitivity by a factor of up to 1.8.