Nadia Buyak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nadia Buyak has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Valerii Deshko
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute
10 shared publications - Inna Bilous
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute
8 shared publications - Olena Naumchuk
Навчально-науковий інститут атомної та теплової енергетики, Національний технічний університет України «Київський політехнічний інститут імені Ігоря Сікорського», Інститут технічної теплофізики НАН України
3 shared publications Anatolijs Borodinecs
1 shared publication- Hanna Hetmanchuk
Національний технічний університет України «Київський політехнічний інститут імені Ігоря Сікорського», пр-т Перемоги, 37, м. Київ, 03056, Україна
1 shared publication I. O. Sukhodub
National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute
1 shared publication
Latest Publications
- 9 April 2026
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 1,p. 55-70
RESEARCH ON THERMAL INSULATION ISSUES OF HISTORIC BUILDINGS
The relevance of this study is driven by increasing energy efficiency requirements for the existing building stock alongside the necessity to preserve historic and architectural heritage. Historic buildings are typically characterized by massive masonry envelopes with high thermal inertia and moisture buffering capacity, which limits the applicability of conventional insulation solutions developed for modern lightweight constructions. Consequently, internal wall insulation of historic buildings requires scientifically substantiated approaches based on comprehensive thermal and hygrothermal assessment of envelope performance and material compatibility.Objective. The objective of this study is to substantiate approaches to the selection and application of insulation materials for internal insulation of historic masonry walls based on a combined thermal and hygrothermal analysis, with particular emphasis on energy efficiency and long-term hygrothermal stability of the building envelope.Methods. The study is based on methods of building physics, normative thermal resistance calculation, and hygrothermal analysis of building envelopes in accordance with the current regulatory framework. Comparative thermal and moisture calculations were performed for internal insulation systems using mineral wool, hemp-based insulation, and cellular foam glass under identical climatic and operating conditions. Material properties were adopted in accordance with national standards, and specialized engineering software was used to ensure consistency and reproducibility of the calculation results.Results. The influence of internal insulation on the thermal and hygrothermal behavior of massive masonry walls typical of historic buildings was analyzed. The results show that insulation materials with comparable thermal resistance values may exhibit fundamentally different hygrothermal performance. Insulation systems with limited moisture-regulating capacity were found to be associated with seasonal moisture accumulation and the formation of an unbalanced annual moisture regime, whereas bio-based insulation materials demonstrated lower moisture accumulation and a more balanced hygrothermal behavior of the envelope. Furthermore, the application of cellular foam glass demonstrated a complete absence of interstitial condensation and zero seasonal moisture accumulation due to its closed-cell structure and high vapor diffusion resistance.Conclusions. The findings indicate that the effectiveness of internal insulation in historic buildings is determined not only by thermal resistance but primarily by the compatibility of insulation materials with the hygrothermal characteristics of traditional masonry. A comprehensive approach to internal thermal retrofitting is substantiated, combining energy efficiency requirements with hygrothermal reliability to ensure durability and long-term preservation of historic building structures.
- 9 April 2026
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 1,p. 55-70
RESEARCH ON THERMAL INSULATION ISSUES OF HISTORIC BUILDINGS
The relevance of this study is driven by increasing energy efficiency requirements for the existing building stock alongside the necessity to preserve historic and architectural heritage. Historic buildings are typically characterized by massive masonry envelopes with high thermal inertia and moisture buffering capacity, which limits the applicability of conventional insulation solutions developed for modern lightweight constructions. Consequently, internal wall insulation of historic buildings requires scientifically substantiated approaches based on comprehensive thermal and hygrothermal assessment of envelope performance and material compatibility.Objective. The objective of this study is to substantiate approaches to the selection and application of insulation materials for internal insulation of historic masonry walls based on a combined thermal and hygrothermal analysis, with particular emphasis on energy efficiency and long-term hygrothermal stability of the building envelope.Methods. The study is based on methods of building physics, normative thermal resistance calculation, and hygrothermal analysis of building envelopes in accordance with the current regulatory framework. Comparative thermal and moisture calculations were performed for internal insulation systems using mineral wool, hemp-based insulation, and cellular foam glass under identical climatic and operating conditions. Material properties were adopted in accordance with national standards, and specialized engineering software was used to ensure consistency and reproducibility of the calculation results.Results. The influence of internal insulation on the thermal and hygrothermal behavior of massive masonry walls typical of historic buildings was analyzed. The results show that insulation materials with comparable thermal resistance values may exhibit fundamentally different hygrothermal performance. Insulation systems with limited moisture-regulating capacity were found to be associated with seasonal moisture accumulation and the formation of an unbalanced annual moisture regime, whereas bio-based insulation materials demonstrated lower moisture accumulation and a more balanced hygrothermal behavior of the envelope. Furthermore, the application of cellular foam glass demonstrated a complete absence of interstitial condensation and zero seasonal moisture accumulation due to its closed-cell structure and high vapor diffusion resistance.Conclusions. The findings indicate that the effectiveness of internal insulation in historic buildings is determined not only by thermal resistance but primarily by the compatibility of insulation materials with the hygrothermal characteristics of traditional masonry. A comprehensive approach to internal thermal retrofitting is substantiated, combining energy efficiency requirements with hygrothermal reliability to ensure durability and long-term preservation of historic building structures.
- Open Access
- 12 March 2025
- Published by Politechnika Koszalinska in Rocznik Ochrona Środowiska
- Vol. 27, 110-120
Parametric Analysis of Heat Flows Through Building Envelope Considering Orientation, Massiveness, and Intermittent Heating Modes
The study's objective is to conduct a parametric analysis of the components of the building's heat balance, and a parametric analysis of heat flows in buildings with different thermal and physical properties. To this end, a non-stationary multi-zone energy model of a multi-story building was developed, which was then utilized to ascertain the components of the energy balance of a pilot room under various temperature control regimes of the heating system, the massiveness of internal and exterior walls, the insulation of the exterior wall, and contingent on the purpose of the room. Two distinct types of building premises are distinguished: residential and commercial. The analysis revealed that representative rooms oriented towards the north exhibited a 34.8% higher energy consumption for heating needs when compared to rooms oriented towards the south for walls comprising a single brick and a 38.3% higher energy consumption for walls composed of three bricks. Implementing intermittent heating modes has been shown to reduce heat energy consumption by 13.8% and 14.6% for a one-brick exterior wall and 18.2% and 19.9% for a three-brick exterior wall, respectively, for residential and public buildings. The impact of altering the massiveness of internal walls on overall energy consumption is negligible. In contrast, the insulation of exterior walls and replacing windows with more energy-efficient ones exhibit a greater potential for reducing energy consumption in a building. A south-facing model with a constant heating mode in January demonstrated a 39.2% reduction in energy consumption for heating compared to a model lacking exterior wall insulation. Implementing additional intermittent heating modes can achieve energy savings of up to 22.3% for south-facing rooms and up to 21.4% for north-facing rooms. The findings of this study offer valuable insights into the regulation of heating modes in buildings with distinct characteristics in terms of exterior and internal wall composition.
- 12 March 2025
- Published by Politechnika Koszalinska in Rocznik Ochrona Środowiska
- Vol. 27, 110-120
Open AccessParametric Analysis of Heat Flows Through Building Envelope Considering Orientation, Massiveness, and Intermittent Heating Modes
The study's objective is to conduct a parametric analysis of the components of the building's heat balance, and a parametric analysis of heat flows in buildings with different thermal and physical properties. To this end, a non-stationary multi-zone energy model of a multi-story building was developed, which was then utilized to ascertain the components of the energy balance of a pilot room under various temperature control regimes of the heating system, the massiveness of internal and exterior walls, the insulation of the exterior wall, and contingent on the purpose of the room. Two distinct types of building premises are distinguished: residential and commercial. The analysis revealed that representative rooms oriented towards the north exhibited a 34.8% higher energy consumption for heating needs when compared to rooms oriented towards the south for walls comprising a single brick and a 38.3% higher energy consumption for walls composed of three bricks. Implementing intermittent heating modes has been shown to reduce heat energy consumption by 13.8% and 14.6% for a one-brick exterior wall and 18.2% and 19.9% for a three-brick exterior wall, respectively, for residential and public buildings. The impact of altering the massiveness of internal walls on overall energy consumption is negligible. In contrast, the insulation of exterior walls and replacing windows with more energy-efficient ones exhibit a greater potential for reducing energy consumption in a building. A south-facing model with a constant heating mode in January demonstrated a 39.2% reduction in energy consumption for heating compared to a model lacking exterior wall insulation. Implementing additional intermittent heating modes can achieve energy savings of up to 22.3% for south-facing rooms and up to 21.4% for north-facing rooms. The findings of this study offer valuable insights into the regulation of heating modes in buildings with distinct characteristics in terms of exterior and internal wall composition.
- 1 January 2023
- Published by Politechnika Koszalinska in Rocznik Ochrona Środowiska
- Vol. 25, 148-158
Prospects for the Use of Renewable Energy Sources while Increasing the Energy Efficiency Level of Office Buildings to the Level of nZEB
According to the Energy Performance of Buildings Directive (EPBD), all new buildings must be constructed using technologies that will ensure almost zero energy consumption by the building through renewable energy sources and an energy-efficient thermal envelope. To assess the possibilities of reconstructing an existing building following the requirements of the EPBD in Ukraine, we have presented possible ways to modernise an office in Kyiv using renewable energy sources (biomass, heat pump) at different levels of thermal protection. Based on dynamic modelling results in the DesignBuilder software environment, the technical, environmental and economic aspects of building modernisation using near-Zero Energy Buildings (nZEB) technologies have been investigated. In particular, the authors have analysed the possibilities of using different modes of heat pump operation to provide heat to a building of different levels of thermal protection in the GeoTSOL software environment. The results obtained can be used to assess the benefits of improving the energy efficiency of a building using different types of renewable energy sources.
- 1 January 2023
- Published by Politechnika Koszalinska in Rocznik Ochrona Środowiska
- Vol. 25, 148-158
Prospects for the Use of Renewable Energy Sources while Increasing the Energy Efficiency Level of Office Buildings to the Level of nZEB
According to the Energy Performance of Buildings Directive (EPBD), all new buildings must be constructed using technologies that will ensure almost zero energy consumption by the building through renewable energy sources and an energy-efficient thermal envelope. To assess the possibilities of reconstructing an existing building following the requirements of the EPBD in Ukraine, we have presented possible ways to modernise an office in Kyiv using renewable energy sources (biomass, heat pump) at different levels of thermal protection. Based on dynamic modelling results in the DesignBuilder software environment, the technical, environmental and economic aspects of building modernisation using near-Zero Energy Buildings (nZEB) technologies have been investigated. In particular, the authors have analysed the possibilities of using different modes of heat pump operation to provide heat to a building of different levels of thermal protection in the GeoTSOL software environment. The results obtained can be used to assess the benefits of improving the energy efficiency of a building using different types of renewable energy sources.
- Open Access
- 14 July 2022
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 2
ECONOMIC ASSESSMENT OF INCREASING THERMAL PROTECTION OF MUNICIPAL BUILDINGS TO MODERN EUROPEAN REQUIREMENTS
According to the plan to reduce carbon dioxide emissions in Ukraine, there is a need to replace traditional energy sources and, accordingly, types of fuel. The paper highlights the main differences between the current regulatory documents in the field of energy efficiency of buildings, analyzes the dynamics of the energy demand of a public building during its thermal modernization to the normative indicators in force in Ukraine and Europe, and the regulation of the heating and ventilation schedule. The energy consumption assessment is based on the results of calculations in accordance with the current standard DSTU A.2.2 - 12:2015 and the building model in the DesignBuilder software environment. Using DesignBuilder helps evaluate new and existing building environmental performance, energy and comfort, HVAC, daylighting, cost, design optimization, CFD, BREEAM/LEED credits and reports that meet multiple national building codes and certification standards. The influence of the economic indicators of Ukraine and Europe on the overall sensitivity of the project to increase the thermal protection of a public building is studied, taking into account the historical increase in energy prices in the countries under consideration. The work is the basis for further analysis and development of the concept of buildings with almost zero energy consumption in Ukraine.
- 14 July 2022
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 2
Open AccessECONOMIC ASSESSMENT OF INCREASING THERMAL PROTECTION OF MUNICIPAL BUILDINGS TO MODERN EUROPEAN REQUIREMENTS
According to the plan to reduce carbon dioxide emissions in Ukraine, there is a need to replace traditional energy sources and, accordingly, types of fuel. The paper highlights the main differences between the current regulatory documents in the field of energy efficiency of buildings, analyzes the dynamics of the energy demand of a public building during its thermal modernization to the normative indicators in force in Ukraine and Europe, and the regulation of the heating and ventilation schedule. The energy consumption assessment is based on the results of calculations in accordance with the current standard DSTU A.2.2 - 12:2015 and the building model in the DesignBuilder software environment. Using DesignBuilder helps evaluate new and existing building environmental performance, energy and comfort, HVAC, daylighting, cost, design optimization, CFD, BREEAM/LEED credits and reports that meet multiple national building codes and certification standards. The influence of the economic indicators of Ukraine and Europe on the overall sensitivity of the project to increase the thermal protection of a public building is studied, taking into account the historical increase in energy prices in the countries under consideration. The work is the basis for further analysis and development of the concept of buildings with almost zero energy consumption in Ukraine.
- 1 January 2021
- Published by Politechnika Koszalinska in Rocznik Ochrona Środowiska
- Vol. 23, 458-469
Сhanging Energy and Exergy Comfort Level after School Thermomodernization
Increasing the level of thermal resistance of the building envelope in combination with the choice of heat source is an urgent task. It is important to take into account changes in the cost of energy over time. Thermal modernization, in its turn, allows to increase the level of thermal comfort, which is not taken into account and evaluated in practice, although the relevant standards for comfort conditions and categories of buildings to ensure comfort have been introduced in Ukraine. This paper analyzes the change in the level of comfort after thermal modernization, determines the category of the building to provide comfortable conditions, as well as identifies the change in the average radiation temperature of the fences, as one of the main factors of PMV change in these conditions.
- 1 January 2021
- Published by Politechnika Koszalinska in Rocznik Ochrona Środowiska
- Vol. 23, 458-469
Сhanging Energy and Exergy Comfort Level after School Thermomodernization
Increasing the level of thermal resistance of the building envelope in combination with the choice of heat source is an urgent task. It is important to take into account changes in the cost of energy over time. Thermal modernization, in its turn, allows to increase the level of thermal comfort, which is not taken into account and evaluated in practice, although the relevant standards for comfort conditions and categories of buildings to ensure comfort have been introduced in Ukraine. This paper analyzes the change in the level of comfort after thermal modernization, determines the category of the building to provide comfortable conditions, as well as identifies the change in the average radiation temperature of the fences, as one of the main factors of PMV change in these conditions.
- Open Access
- 27 April 2020
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 4
ANALYSIS OF THE INFLUENCE OF ENERGY EFFICIENT HEATING MODES ON BUILDINGS ENERGY USE BASING ON THE MATHEMATICAL MODELING
Global trends of increasing the buildings energy efficiency are aimed at reducing energy use to nearly zero consumption (nZEB). Achieving the nZEB level requires the implementation of a set energy-saving measures to improve the thermophysical properties of fences, building engineering systems and the use of renewable energy sources. One of low-cost and energy-efficient measures to increase the level of energy efficiency of buildings is the introduction of energy-efficient intermittent heating modes of buildings. Usually, this measure is appropriate and possible after the thermal modernization of the building. Determining the energy performance of buildings for the introduction of intermittent heating modes requires the use of mathematical models. The paper compares the application of different mathematical models and methods for estimating thermal energy savings in thermal modernization and implementation of intermittent heating modes based on the quasi-stationary model according to DSTU B A.2.2-12: 2015, stadium model created on the basis of RETScreen software and dynamic model 5R1C according to EN ISO 13790 and EN 13786. Heat-accumulation properties of building enclosures in RETScreen are not taken into account, in DSTU B A.2.2-12: 2015 - are taken into account for external enclosures, 5R1C - both internal and external enclosures are taken into account. The calculation was made for a residential building and a gymnasium located in the city of Kyiv. The introduction of a set of measures for thermal modernization of building fences will reduce heat consumption by 60 and 35% for residential building reinforced and gymnasiums, respectively. Introduction of intermittent heating modes for buildings after thermal modernization / modern buildings allows to save on heating more than 15% - determined on the basis of RETScreen program, 10% - on the basis of dynamic grid model 5R1C, 22% - on the basis of quasi-stationary method according to DSTU B A.2.2- 12: 2015, for a residential building and a gymnasium building located in Kyiv.
- 27 April 2020
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 4
Open AccessANALYSIS OF THE INFLUENCE OF ENERGY EFFICIENT HEATING MODES ON BUILDINGS ENERGY USE BASING ON THE MATHEMATICAL MODELING
Global trends of increasing the buildings energy efficiency are aimed at reducing energy use to nearly zero consumption (nZEB). Achieving the nZEB level requires the implementation of a set energy-saving measures to improve the thermophysical properties of fences, building engineering systems and the use of renewable energy sources. One of low-cost and energy-efficient measures to increase the level of energy efficiency of buildings is the introduction of energy-efficient intermittent heating modes of buildings. Usually, this measure is appropriate and possible after the thermal modernization of the building. Determining the energy performance of buildings for the introduction of intermittent heating modes requires the use of mathematical models. The paper compares the application of different mathematical models and methods for estimating thermal energy savings in thermal modernization and implementation of intermittent heating modes based on the quasi-stationary model according to DSTU B A.2.2-12: 2015, stadium model created on the basis of RETScreen software and dynamic model 5R1C according to EN ISO 13790 and EN 13786. Heat-accumulation properties of building enclosures in RETScreen are not taken into account, in DSTU B A.2.2-12: 2015 - are taken into account for external enclosures, 5R1C - both internal and external enclosures are taken into account. The calculation was made for a residential building and a gymnasium located in the city of Kyiv. The introduction of a set of measures for thermal modernization of building fences will reduce heat consumption by 60 and 35% for residential building reinforced and gymnasiums, respectively. Introduction of intermittent heating modes for buildings after thermal modernization / modern buildings allows to save on heating more than 15% - determined on the basis of RETScreen program, 10% - on the basis of dynamic grid model 5R1C, 22% - on the basis of quasi-stationary method according to DSTU B A.2.2- 12: 2015, for a residential building and a gymnasium building located in Kyiv.
- Open Access
- 28 March 2020
- Published by Odesa National University of Technology in Refrigeration Engineering and Technology
- Vol. 55 (5-6) , 282-292
EN Assessment of the window replacement influence on building energy consumption and human thermal comfort on the basis of dynamic modeling
The dynamic modeling of the energy characteristics of building structures with the help of energy-saving double-glazed windows was carried out in the work. The influence of different variants of windows replacement on the heat energy state of a typical mass building for various glazing coefficients in dynamic grid models created on the basis of the Energy Plus software product was analyzed. It is found that argon-filled glass, selective-coated glass on the outer and inner glass can reduce the energy requirement for the building by 8-10% compared to the double-glazed glass without selectively coating and filling the chambers with air. The load on the heating system is significantly different for the orientations North and South. It is assumed that the coefficient of glassy glass in the orientation of the South during the off-season (autumn / spring), less heating (switched on / off later). For North and South orientations, energy-saving windows with selective coating and / or filled up with inert gas cells have a different effect, which is explained by the coefficients of solar heat transmission, which was obtained on the basis of the simulation model. In addition, current standards in Ukraine do not provide all variants of the coefficients of optical transmittance characteristics of solar heat gains. In this work, a dynamic hourly simulation of the building energy demand in heated space for representative rooms N and S oriented for different glazing coefficients and window types has been carried out. Range of PMV change, average radiating temperature and air temperature in the room for the heating period were estimated. It was established that changing windows glazing can affect the PMV to change almost two times, which indicates the need for an integrated approach to the assessment of thermal comfort. Namely, the importance of taking into account the dynamic changes in the environment parameters and possible thermo-modernization were detected
- 28 March 2020
- Published by Odesa National University of Technology in Refrigeration Engineering and Technology
- Vol. 55 (5-6) , 282-292
Open AccessEN Assessment of the window replacement influence on building energy consumption and human thermal comfort on the basis of dynamic modeling
The dynamic modeling of the energy characteristics of building structures with the help of energy-saving double-glazed windows was carried out in the work. The influence of different variants of windows replacement on the heat energy state of a typical mass building for various glazing coefficients in dynamic grid models created on the basis of the Energy Plus software product was analyzed. It is found that argon-filled glass, selective-coated glass on the outer and inner glass can reduce the energy requirement for the building by 8-10% compared to the double-glazed glass without selectively coating and filling the chambers with air. The load on the heating system is significantly different for the orientations North and South. It is assumed that the coefficient of glassy glass in the orientation of the South during the off-season (autumn / spring), less heating (switched on / off later). For North and South orientations, energy-saving windows with selective coating and / or filled up with inert gas cells have a different effect, which is explained by the coefficients of solar heat transmission, which was obtained on the basis of the simulation model. In addition, current standards in Ukraine do not provide all variants of the coefficients of optical transmittance characteristics of solar heat gains. In this work, a dynamic hourly simulation of the building energy demand in heated space for representative rooms N and S oriented for different glazing coefficients and window types has been carried out. Range of PMV change, average radiating temperature and air temperature in the room for the heating period were estimated. It was established that changing windows glazing can affect the PMV to change almost two times, which indicates the need for an integrated approach to the assessment of thermal comfort. Namely, the importance of taking into account the dynamic changes in the environment parameters and possible thermo-modernization were detected
- Open Access
- 15 September 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (4.3) , 383-386
Influence of Subjective and Objective Thermal Comfort Parameters on Building Primary Fuel Energy Consumption
The building is considered together with a heating source in the analysis, it is also proposed to include a human thermal comfort model in this complex system. Regression equations for determining the comfortable room air temperature according to energy and exergy approaches are presented. Human thermal comfort model is included for the first time in the complex building energy system, by determining the comfortable room air temperature, which corresponds to PMV (predicted mean vote), not lower than value for the corresponding building category. The effect of enclosing structures thermal resistance changes on space average radiant temperature and on building category in terms of providing comfortable conditions is estimated. The influence of thermal comfort subjective parameters on primary fuel exergy consumption by the centralized heating system is estimated on the basis of developed model for the Ukrainian conditions.
- 15 September 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (4.3) , 383-386
Open AccessInfluence of Subjective and Objective Thermal Comfort Parameters on Building Primary Fuel Energy Consumption
The building is considered together with a heating source in the analysis, it is also proposed to include a human thermal comfort model in this complex system. Regression equations for determining the comfortable room air temperature according to energy and exergy approaches are presented. Human thermal comfort model is included for the first time in the complex building energy system, by determining the comfortable room air temperature, which corresponds to PMV (predicted mean vote), not lower than value for the corresponding building category. The effect of enclosing structures thermal resistance changes on space average radiant temperature and on building category in terms of providing comfortable conditions is estimated. The influence of thermal comfort subjective parameters on primary fuel exergy consumption by the centralized heating system is estimated on the basis of developed model for the Ukrainian conditions.
- 1 July 2017
- Published by Elsevier in Energy and Buildings
- Vol. 146, 172-181
Buildings energy use and human thermal comfort according to energy and exergy approach
- 1 July 2017
- Published by Elsevier in Energy and Buildings
- Vol. 146, 172-181
Buildings energy use and human thermal comfort according to energy and exergy approach