MVMatthieu Vivier

Matthieu Vivier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Matthieu Vivier has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Sensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment

    by M. Cappelli, A. Wallach, H. Abele, G. Angloher, B. Arnold, M. Atzori Corona, A. Bento, E. Bossio, F. Buchsteiner, J. Burkhart, et al.

    Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving optimal sensitivity for these kinds of detectors is crucial for signal identification, leading to various optimization techniques. In this work, we present two complementary methods to increase the sensitivity of cryogenic detectors read out by transition-edge sensors, developed and tested in the context of the NUCLEUS experiment. The first procedure maps the signal-to-noise ratio of the device across a wide range of operating points, to identify the configuration with maximal sensitivity to be used during data taking. The second method exploits the double readout of the detector, combining the information from different channels with a two-dimensional optimum filter analysis that effectively lowers the energy threshold. By combining both techniques at the same time, we obtain a baseline resolution of 2.94 ± 0.05 stat ±0.74 syst eV using a CaWO 4 based detector, achieving a promising result ahead of the first run of NUCLEUS at the experimental site.

  • Open Access

    Publisher Correction: Characterization of the low energy excess using a NUCLEUS $\text {Al}_{2}\text {O}_{3}$ detector

    by H. Abele, G. Angloher, B. Arnold, M. Atzori Corona, A. Bento, E. Bossio, F. Buchsteiner, J. Burkhart, F. Cappella, M. Cappelli, et al.

  • Open Access

    Characterization of the low energy excess using a NUCLEUS Al$_2$O$_3$ detector

    by H. Abele, G. Angloher, B. Arnold, M. Atzori Corona, A. Bento, E. Bossio, F. Buchsteiner, J. Burkhart, F. Cappella, M. Cappelli, et al.

    The NUCLEUS experiment aims to detect coherent elastic neutrino–nucleus scattering of reactor antineutrinos using low-threshold, gram-scale cryogenic calorimeters. Similar to other low-threshold experiments, NUCLEUS observes a sharp rise in the event rate below a few hundred eV, referred to as the low energy excess (LEE), whose origin remains yet unidentified. Building on results from the NUCLEUS testing and commissioning at the Technical University of Munich and from previous characterization campaigns, we present a comprehensive study of the background rate measured with a sapphire detector equipped with two transition-edge sensors under various experimental conditions. We find no evidence for a dependence of the LEE rate on the particle background level, whereas the results indicate that slower cooling-down procedures lead to lower initial LEE rates. The behavior of the LEE rate during the same cooldown is comparable across the measurements and is best described by a power law with a common exponent across datasets of $$(-0.59\pm 0.06)$$ ( - 0.59 ± 0.06 ) , when time is expressed from the moment the detector reaches the 4 K temperature. These findings provide valuable guidance for future LEE mitigation strategies in the NUCLEUS experiment.


  • Open Access

    Particle background characterization and prediction for the NUCLEUS reactor CE$\nu $NS experiment

    by H. Abele, G. Angloher, B. Arnold, M. Atzori Corona, A. Bento, E. Bossio, F. Buchsteiner, J. Burkhart, F. Cappella, M. Cappelli, et al.

    NUCLEUS is a cryogenic detection experiment which aims to measure Coherent Elastic Neutrino–Nucleus Scattering (CE $$\nu $$ ν NS) and to search for new physics at the Chooz nuclear power plant in France. This article reports on the prediction of particle-induced backgrounds, especially focusing on the sub-keV energy range, which is a poorly known region where most of the CE $$\nu $$ ν NS signal from reactor antineutrinos is expected. Together with measurements of the environmental background radiations at the experimental site, extensive Monte Carlo simulations based on the Geant4 package were run both to optimize the experimental setup for background reduction and to estimate the residual rates arising from different contributions such as cosmic ray-induced radiations, environmental gammas and material radioactivity. The NUCLEUS experimental setup is predicted to achieve a total rejection power of more than two orders of magnitude, leaving a residual background component which is strongly dominated by cosmic ray-induced neutrons. In the CE $$\nu $$ ν NS signal region of interest between 10 and 100 eV, a total particle background rate of $$\sim $$ ∼ 250 d −1 kg −1 keV −1 is expected in the CaWO 4 target detectors. This corresponds to a signal-to-background ratio $$\gtrsim $$ ≳ 1, and therefore meets the required specifications in terms of particle background rejection for the detection of reactor antineutrinos through CE $$\nu $$ ν NS.


  • Open Access

    Commissioning of the NUCLEUS Experiment at the Technical University of Munich

    by H. Abele, G. Angloher, B. Arnold, M. Atzori Corona, A. Bento, E. Bossio, F. Buchsteiner, J. Burkhart, F. Cappella, M. Cappelli, et al.

    The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos on CaWO 4 targets in the fully coherent regime, using gram-scale cryogenic calorimeters. The experimental apparatus will be installed at the Chooz nuclear power plant in France, in the vicinity of two 4.25 GW th reactor cores. This work presents results from the commissioning of an essential version of the experiment at the shallow Underground Laboratory of the Technical University of Munich. For the first time, two cryogenic target detectors were tested alongside active and passive shielding systems. Over a period of two months, all detector subsystems were operated with stable performance. Background measurements were conducted, providing important benchmarks for the modeling of background sources at the reactor site. Finally, we present ongoing efforts to upgrade the detector systems in preparation for a technical run at Chooz in 2026, and highlight the remaining challenges to achieving neutrino detection.


  • Open Access

    The CRAB facility at the TU Wien TRIGA reactor: status and related physics program

    by H. Abele, P. Ajello, A. Armatol, B. Arnold, J. Billard, E. Bossio, J. Burkhart, F. Cappella, N. Casali, R. Cerulli, et al.

    The Crab (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter search experiments. The Crab method relies on the radiative capture of thermal neutrons in the target detector, resulting in a nuclear recoil with a well-defined energy. We present a new experimental setup installed at the TRIGA Mark-II reactor at Atominstitut (Vienna), providing a low intensity beam of thermal neutrons sent to the target cryogenic detector mounted inside a wet dilution refrigerator Kelvinox 100. After the presentation of all components of the setup we report the analysis of first commissioning data with CaWO $$_{4}$$ 4 detectors of the Nucleus experiment. They show stable operation of the cryostat and detectors on a week-scale. Due to an energy resolution currently limited to 20 eV we use neutron beam induced events at high energy, in the 10 to 100 keV range, to demonstrate the excellent agreement between the data and simulation and the accurate understanding of external background. Thanks to these data we also propose an updated decay scheme of the low-lying excited states of $$^{187}$$ 187 W. Finally, we present the first evidence of neutron-capture induced coincidences between BaF $$_2$$ 2 $$\gamma $$ γ -detectors installed around the dewar and the inner cryogenic detector. These promising results pave the way for an extensive physics program with various detector materials, like CaWO $$_{4}$$ 4 , Al $$_{2}$$ 2 O $$_{3}$$ 3 , Ge and Si.


  • Open Access

    Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters Using a Novel X-ray Fluorescence Source

    by H. Abele, G. Angloher, B. Arnold, M. Atzori Corona, A. Bento, E. Bossio, J. Burkhart, F. Cappella, M. Cappelli, N. Casali, et al.

    Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100 eV is crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $$^{55}$$ 55 Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677 eV to 6.5 keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 g CaWO $$_4$$ 4 crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES).


  • Open Access

    Decoupling pulse tube vibrations from a dry dilution refrigerator at milli-Kelvin temperatures

    by A. Wex, J. Rothe, L. Peters, H. Abele, G. Angloher, B. Arnold, M. Atzori Corona, A. Bento, E. Bossio, J. Burkhart, et al.

    With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a cryogenic spring pendulum has been engineered to effectively isolate pulse tube vibrations by establishing an autonomous frame of reference for the experimental volume, while sustaining temperatures below 10 mK. Attaining attenuation of up to two orders of magnitude within the region of interest of the NUCLEUS cryogenic detectors, we achieved displacement RMS values in the order of 1 nm in the axial direction and 100 pm radially, thereby reducing vibrations below typical environmental levels. Our successful detector operation across multiple cooldown cycles demonstrated negligible sensitivity to pulse tube induced vibrations, culminating in the achievement of an ultra-low (6.22 ± 0.07) eV baseline resolution on a gram-scale CaWO4 cryogenic calorimeter during continuous pulse tube operation over the course of several weeks.


  • Comprehensive revision of the summation method for the prediction of reactor ν¯e fluxes and spectra

    by Lorenzo Périssé, Anthony Onillon, Xavier Mougeot, Matthieu Vivier, Thierry Lasserre, Alain Letourneau, David Lhuillier, Guillaume Mention

    The summation method for the calculation of reactor ν¯e fluxes and spectra is methodically revised and improved. For the first time, a complete uncertainty budget accounting for all known effects likely to impact these calculations is proposed. Uncertainties of a few percent at low energies and ranging up to 20% at high energies are obtained on the calculation of a typical reactor ν¯e spectrum. Although huge improvements have been achieved over the past decade, the quality and incompleteness of the present day evaluated nuclear decay data still limit the accuracy of the calculations and therefore dominate by far these uncertainties. Pushing the β-decay modeling of the thousands of branches making a reactor ν¯e spectrum to a high level of details comparatively brings modest changes. In particular, including nuclear structure calculations in the evaluation of the nonunique forbidden transitions gives a smaller impact than anticipated in past studies. Finally, this new modeling is challenged against state-of-the-art predictions and measurements. While a good agreement is observed with the most recent inverse β decay measurements of reactor ν¯e fluxes and spectra, it is unable to properly describe the reference aggregate β spectra measured at the Institut Laue-Langevin High-Flux Reactor in the 1980s. This result adds to recent suspicions about the reliability of these data and preferentially points toward a misprediction of the U235 ν¯e spectrum.