Thierry Lasserre
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Thierry Lasserre has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Matthieu Vivier
IRFU CEA Université Paris-Saclay F-91191 Gif-sur-Yvette France
13 shared publications - David Lhuillier
IRFU, CEA, Université Paris-Saclay, Gif-sur-Yvette, France
11 shared publications - S. Schönert
Technische Universität München
10 shared publications - A. Erhart
Technische Universität München
9 shared publications - A. Wex
Technische Universität München
9 shared publications - Chloé Goupy
IRFU, CEA, Université Paris-Saclay, Gif-sur-Yvette, France
9 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10026
Sensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment
Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving optimal sensitivity for these kinds of detectors is crucial for signal identification, leading to various optimization techniques. In this work, we present two complementary methods to increase the sensitivity of cryogenic detectors read out by transition-edge sensors, developed and tested in the context of the NUCLEUS experiment. The first procedure maps the signal-to-noise ratio of the device across a wide range of operating points, to identify the configuration with maximal sensitivity to be used during data taking. The second method exploits the double readout of the detector, combining the information from different channels with a two-dimensional optimum filter analysis that effectively lowers the energy threshold. By combining both techniques at the same time, we obtain a baseline resolution of 2.94 ± 0.05 stat ±0.74 syst eV using a CaWO 4 based detector, achieving a promising result ahead of the first run of NUCLEUS at the experimental site.
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10026
Open AccessSensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment
Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving optimal sensitivity for these kinds of detectors is crucial for signal identification, leading to various optimization techniques. In this work, we present two complementary methods to increase the sensitivity of cryogenic detectors read out by transition-edge sensors, developed and tested in the context of the NUCLEUS experiment. The first procedure maps the signal-to-noise ratio of the device across a wide range of operating points, to identify the configuration with maximal sensitivity to be used during data taking. The second method exploits the double readout of the detector, combining the information from different channels with a two-dimensional optimum filter analysis that effectively lowers the energy threshold. By combining both techniques at the same time, we obtain a baseline resolution of 2.94 ± 0.05 stat ±0.74 syst eV using a CaWO 4 based detector, achieving a promising result ahead of the first run of NUCLEUS at the experimental site.
- Open Access
- 17 August 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (8) , 973
Publisher Correction: Characterization of the low energy excess using a NUCLEUS $\text {Al}_{2}\text {O}_{3}$ detector- 17 August 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (8) , 973
Open AccessPublisher Correction: Characterization of the low energy excess using a NUCLEUS $\text {Al}_{2}\text {O}_{3}$ detector - Open Access
- 18 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7) , 831
Characterization of the low energy excess using a NUCLEUS Al$_2$O$_3$ detectorThe NUCLEUS experiment aims to detect coherent elastic neutrino–nucleus scattering of reactor antineutrinos using low-threshold, gram-scale cryogenic calorimeters. Similar to other low-threshold experiments, NUCLEUS observes a sharp rise in the event rate below a few hundred eV, referred to as the low energy excess (LEE), whose origin remains yet unidentified. Building on results from the NUCLEUS testing and commissioning at the Technical University of Munich and from previous characterization campaigns, we present a comprehensive study of the background rate measured with a sapphire detector equipped with two transition-edge sensors under various experimental conditions. We find no evidence for a dependence of the LEE rate on the particle background level, whereas the results indicate that slower cooling-down procedures lead to lower initial LEE rates. The behavior of the LEE rate during the same cooldown is comparable across the measurements and is best described by a power law with a common exponent across datasets of $$(-0.59\pm 0.06)$$ , when time is expressed from the moment the detector reaches the 4 K temperature. These findings provide valuable guidance for future LEE mitigation strategies in the NUCLEUS experiment.- 18 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7) , 831
Open AccessCharacterization of the low energy excess using a NUCLEUS Al$_2$O$_3$ detectorThe NUCLEUS experiment aims to detect coherent elastic neutrino–nucleus scattering of reactor antineutrinos using low-threshold, gram-scale cryogenic calorimeters. Similar to other low-threshold experiments, NUCLEUS observes a sharp rise in the event rate below a few hundred eV, referred to as the low energy excess (LEE), whose origin remains yet unidentified. Building on results from the NUCLEUS testing and commissioning at the Technical University of Munich and from previous characterization campaigns, we present a comprehensive study of the background rate measured with a sapphire detector equipped with two transition-edge sensors under various experimental conditions. We find no evidence for a dependence of the LEE rate on the particle background level, whereas the results indicate that slower cooling-down procedures lead to lower initial LEE rates. The behavior of the LEE rate during the same cooldown is comparable across the measurements and is best described by a power law with a common exponent across datasets of $$(-0.59\pm 0.06)$$ , when time is expressed from the moment the detector reaches the 4 K temperature. These findings provide valuable guidance for future LEE mitigation strategies in the NUCLEUS experiment. - Open Access
- 16 January 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (1) , 29
Particle background characterization and prediction for the NUCLEUS reactor CE$\nu $NS experimentNUCLEUS is a cryogenic detection experiment which aims to measure Coherent Elastic Neutrino–Nucleus Scattering (CE $$\nu $$ NS) and to search for new physics at the Chooz nuclear power plant in France. This article reports on the prediction of particle-induced backgrounds, especially focusing on the sub-keV energy range, which is a poorly known region where most of the CE $$\nu $$ NS signal from reactor antineutrinos is expected. Together with measurements of the environmental background radiations at the experimental site, extensive Monte Carlo simulations based on the Geant4 package were run both to optimize the experimental setup for background reduction and to estimate the residual rates arising from different contributions such as cosmic ray-induced radiations, environmental gammas and material radioactivity. The NUCLEUS experimental setup is predicted to achieve a total rejection power of more than two orders of magnitude, leaving a residual background component which is strongly dominated by cosmic ray-induced neutrons. In the CE $$\nu $$ NS signal region of interest between 10 and 100 eV, a total particle background rate of $$\sim $$ 250 d −1 kg −1 keV −1 is expected in the CaWO 4 target detectors. This corresponds to a signal-to-background ratio $$\gtrsim $$ 1, and therefore meets the required specifications in terms of particle background rejection for the detection of reactor antineutrinos through CE $$\nu $$ NS.- 16 January 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (1) , 29
Open AccessParticle background characterization and prediction for the NUCLEUS reactor CE$\nu $NS experimentNUCLEUS is a cryogenic detection experiment which aims to measure Coherent Elastic Neutrino–Nucleus Scattering (CE $$\nu $$ NS) and to search for new physics at the Chooz nuclear power plant in France. This article reports on the prediction of particle-induced backgrounds, especially focusing on the sub-keV energy range, which is a poorly known region where most of the CE $$\nu $$ NS signal from reactor antineutrinos is expected. Together with measurements of the environmental background radiations at the experimental site, extensive Monte Carlo simulations based on the Geant4 package were run both to optimize the experimental setup for background reduction and to estimate the residual rates arising from different contributions such as cosmic ray-induced radiations, environmental gammas and material radioactivity. The NUCLEUS experimental setup is predicted to achieve a total rejection power of more than two orders of magnitude, leaving a residual background component which is strongly dominated by cosmic ray-induced neutrons. In the CE $$\nu $$ NS signal region of interest between 10 and 100 eV, a total particle background rate of $$\sim $$ 250 d −1 kg −1 keV −1 is expected in the CaWO 4 target detectors. This corresponds to a signal-to-background ratio $$\gtrsim $$ 1, and therefore meets the required specifications in terms of particle background rejection for the detection of reactor antineutrinos through CE $$\nu $$ NS. - Open Access
- 28 October 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (7)
Commissioning of the NUCLEUS Experiment at the Technical University of Munich
The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos on CaWO 4 targets in the fully coherent regime, using gram-scale cryogenic calorimeters. The experimental apparatus will be installed at the Chooz nuclear power plant in France, in the vicinity of two 4.25 GW th reactor cores. This work presents results from the commissioning of an essential version of the experiment at the shallow Underground Laboratory of the Technical University of Munich. For the first time, two cryogenic target detectors were tested alongside active and passive shielding systems. Over a period of two months, all detector subsystems were operated with stable performance. Background measurements were conducted, providing important benchmarks for the modeling of background sources at the reactor site. Finally, we present ongoing efforts to upgrade the detector systems in preparation for a technical run at Chooz in 2026, and highlight the remaining challenges to achieving neutrino detection.
- 28 October 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (7)
Open AccessCommissioning of the NUCLEUS Experiment at the Technical University of Munich
The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos on CaWO 4 targets in the fully coherent regime, using gram-scale cryogenic calorimeters. The experimental apparatus will be installed at the Chooz nuclear power plant in France, in the vicinity of two 4.25 GW th reactor cores. This work presents results from the commissioning of an essential version of the experiment at the shallow Underground Laboratory of the Technical University of Munich. For the first time, two cryogenic target detectors were tested alongside active and passive shielding systems. Over a period of two months, all detector subsystems were operated with stable performance. Background measurements were conducted, providing important benchmarks for the modeling of background sources at the reactor site. Finally, we present ongoing efforts to upgrade the detector systems in preparation for a technical run at Chooz in 2026, and highlight the remaining challenges to achieving neutrino detection.
- Open Access
- 22 October 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (10) , 1-24
The CRAB facility at the TU Wien TRIGA reactor: status and related physics program
The Crab (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter search experiments. The Crab method relies on the radiative capture of thermal neutrons in the target detector, resulting in a nuclear recoil with a well-defined energy. We present a new experimental setup installed at the TRIGA Mark-II reactor at Atominstitut (Vienna), providing a low intensity beam of thermal neutrons sent to the target cryogenic detector mounted inside a wet dilution refrigerator Kelvinox 100. After the presentation of all components of the setup we report the analysis of first commissioning data with CaWO $$_{4}$$ detectors of the Nucleus experiment. They show stable operation of the cryostat and detectors on a week-scale. Due to an energy resolution currently limited to 20 eV we use neutron beam induced events at high energy, in the 10 to 100 keV range, to demonstrate the excellent agreement between the data and simulation and the accurate understanding of external background. Thanks to these data we also propose an updated decay scheme of the low-lying excited states of $$^{187}$$ W. Finally, we present the first evidence of neutron-capture induced coincidences between BaF $$_2$$ $$\gamma $$ -detectors installed around the dewar and the inner cryogenic detector. These promising results pave the way for an extensive physics program with various detector materials, like CaWO $$_{4}$$ , Al $$_{2}$$ O $$_{3}$$ , Ge and Si.- 22 October 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (10) , 1-24
Open AccessThe CRAB facility at the TU Wien TRIGA reactor: status and related physics program
The Crab (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter search experiments. The Crab method relies on the radiative capture of thermal neutrons in the target detector, resulting in a nuclear recoil with a well-defined energy. We present a new experimental setup installed at the TRIGA Mark-II reactor at Atominstitut (Vienna), providing a low intensity beam of thermal neutrons sent to the target cryogenic detector mounted inside a wet dilution refrigerator Kelvinox 100. After the presentation of all components of the setup we report the analysis of first commissioning data with CaWO $$_{4}$$ detectors of the Nucleus experiment. They show stable operation of the cryostat and detectors on a week-scale. Due to an energy resolution currently limited to 20 eV we use neutron beam induced events at high energy, in the 10 to 100 keV range, to demonstrate the excellent agreement between the data and simulation and the accurate understanding of external background. Thanks to these data we also propose an updated decay scheme of the low-lying excited states of $$^{187}$$ W. Finally, we present the first evidence of neutron-capture induced coincidences between BaF $$_2$$ $$\gamma $$ -detectors installed around the dewar and the inner cryogenic detector. These promising results pave the way for an extensive physics program with various detector materials, like CaWO $$_{4}$$ , Al $$_{2}$$ O $$_{3}$$ , Ge and Si. - Open Access
First Measurement of Neutrino Emissions from Spent Nuclear Fuel by the Double Chooz Experiment
Neutrino emission from nuclear reactors provides real-time insights into reactor power and fuel evolution, with potential applications in monitoring and nuclear safeguards. Following reactor shutdown, a low-intensity flux of ``residual neutrinos'' persists due to the decay of long-lived fission isotopes in the partially burnt fuel remaining within the reactor cores and in spent nuclear fuel stored in nearby cooling pools. The Double Chooz experiment at the Chooz B nuclear power plant in France achieved the first quantitative measurement of this residual flux based on 17.2 days of reactor-off data. In the energy range where the residual signal is most pronounced, the neutrino detector located 400$\,$m from the cores recorded $106 \pm 18$ neutrino candidate events (5.9$σ$ significance). This measurement is in excellent agreement with the predicted value of $88 \pm 7$ events derived from detailed reactor simulations modeling the decay activities of fission products and incorporating the best-available models of neutrino spectra.Open AccessFirst Measurement of Neutrino Emissions from Spent Nuclear Fuel by the Double Chooz Experiment
Neutrino emission from nuclear reactors provides real-time insights into reactor power and fuel evolution, with potential applications in monitoring and nuclear safeguards. Following reactor shutdown, a low-intensity flux of ``residual neutrinos'' persists due to the decay of long-lived fission isotopes in the partially burnt fuel remaining within the reactor cores and in spent nuclear fuel stored in nearby cooling pools. The Double Chooz experiment at the Chooz B nuclear power plant in France achieved the first quantitative measurement of this residual flux based on 17.2 days of reactor-off data. In the energy range where the residual signal is most pronounced, the neutrino detector located 400$\,$m from the cores recorded $106 \pm 18$ neutrino candidate events (5.9$σ$ significance). This measurement is in excellent agreement with the predicted value of $88 \pm 7$ events derived from detailed reactor simulations modeling the decay activities of fission products and incorporating the best-available models of neutrino spectra. - Open Access
- 6 September 2025
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 221 (1-6) , 265-288
Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters Using a Novel X-ray Fluorescence Source
Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100 eV is crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $$^{55}$$ Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677 eV to 6.5 keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 g CaWO $$_4$$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES).- 6 September 2025
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 221 (1-6) , 265-288
Open AccessSub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters Using a Novel X-ray Fluorescence Source
Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100 eV is crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $$^{55}$$ Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677 eV to 6.5 keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 g CaWO $$_4$$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES). - Open Access
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , P05022
Decoupling pulse tube vibrations from a dry dilution refrigerator at milli-Kelvin temperatures
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a cryogenic spring pendulum has been engineered to effectively isolate pulse tube vibrations by establishing an autonomous frame of reference for the experimental volume, while sustaining temperatures below 10 mK. Attaining attenuation of up to two orders of magnitude within the region of interest of the NUCLEUS cryogenic detectors, we achieved displacement RMS values in the order of 1 nm in the axial direction and 100 pm radially, thereby reducing vibrations below typical environmental levels. Our successful detector operation across multiple cooldown cycles demonstrated negligible sensitivity to pulse tube induced vibrations, culminating in the achievement of an ultra-low (6.22 ± 0.07) eV baseline resolution on a gram-scale CaWO4 cryogenic calorimeter during continuous pulse tube operation over the course of several weeks.
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , P05022
Open AccessDecoupling pulse tube vibrations from a dry dilution refrigerator at milli-Kelvin temperatures
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a cryogenic spring pendulum has been engineered to effectively isolate pulse tube vibrations by establishing an autonomous frame of reference for the experimental volume, while sustaining temperatures below 10 mK. Attaining attenuation of up to two orders of magnitude within the region of interest of the NUCLEUS cryogenic detectors, we achieved displacement RMS values in the order of 1 nm in the axial direction and 100 pm radially, thereby reducing vibrations below typical environmental levels. Our successful detector operation across multiple cooldown cycles demonstrated negligible sensitivity to pulse tube induced vibrations, culminating in the achievement of an ultra-low (6.22 ± 0.07) eV baseline resolution on a gram-scale CaWO4 cryogenic calorimeter during continuous pulse tube operation over the course of several weeks.
- Open Access
Sterile-neutrino search based on 259 days of KATRIN data
Neutrinos are the most abundant fundamental matter particles in the Universe and play a crucial role in particle physics and cosmology. Neutrino oscillation, discovered about 25 years ago, reveals that the three known species mix with each other. Anomalous results from reactor and radioactive-source experiments suggest a possible fourth neutrino state, the sterile neutrino, which does not interact via the weak force. The KATRIN experiment, primarily designed to measure the neutrino mass via tritium $β$-decay, also searches for sterile neutrinos suggested by these anomalies. A sterile-neutrino signal would appear as a distortion in the $β$-decay energy spectrum, characterized by a discontinuity in curvature (kink) related to the sterile-neutrino mass. This signature, which depends only on the shape of the spectrum rather than its absolute normalization, offers a robust, complementary approach to reactor experiments. KATRIN examined the energy spectrum of 36 million tritium $β$-decay electrons recorded in 259 measurement days within the last 40 electronvolt below the endpoint. The results exclude a substantial part of the parameter space suggested by the gallium anomaly and challenge the Neutrino-4 claim. Together with other neutrino-disappearance experiments, KATRIN probes sterile-to-active mass splittings from a fraction of an electron-volt squared to several hundred electron-volts squared, excluding light sterile neutrinos with mixing angles above a few percent.
Open AccessSterile-neutrino search based on 259 days of KATRIN data
Neutrinos are the most abundant fundamental matter particles in the Universe and play a crucial role in particle physics and cosmology. Neutrino oscillation, discovered about 25 years ago, reveals that the three known species mix with each other. Anomalous results from reactor and radioactive-source experiments suggest a possible fourth neutrino state, the sterile neutrino, which does not interact via the weak force. The KATRIN experiment, primarily designed to measure the neutrino mass via tritium $β$-decay, also searches for sterile neutrinos suggested by these anomalies. A sterile-neutrino signal would appear as a distortion in the $β$-decay energy spectrum, characterized by a discontinuity in curvature (kink) related to the sterile-neutrino mass. This signature, which depends only on the shape of the spectrum rather than its absolute normalization, offers a robust, complementary approach to reactor experiments. KATRIN examined the energy spectrum of 36 million tritium $β$-decay electrons recorded in 259 measurement days within the last 40 electronvolt below the endpoint. The results exclude a substantial part of the parameter space suggested by the gallium anomaly and challenge the Neutrino-4 claim. Together with other neutrino-disappearance experiments, KATRIN probes sterile-to-active mass splittings from a fraction of an electron-volt squared to several hundred electron-volts squared, excluding light sterile neutrinos with mixing angles above a few percent.