Marat Z. Muradymov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marat Z. Muradymov has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
A. N. Arseniev
Russian Academy of Sciences
1 shared publicationAlexey A. Kayumov
Institute for Analytical Instrumentation of Russian Academy of Sciences, Saint Petersburg, Russia
1 shared publicationAndrey V. Samokish
Institute for Analytical Instrumentation of Russian Academy of Sciences, Saint Petersburg, Russia
1 shared publication- Igor V. Kurnin
Institute for Analytical Instrumentation (Russia)
1 shared publication N. V. Krasnov
Institute for Analytical Instrumentation of Russian Academy of Sciences 26 Rizhsky pr 190103 Saint Petersburg Russia
1 shared publicationNikolay V. Krasnov
Institute for Analytical Instrumentation of Russian Academy of Sciences, Saint Petersburg, Russia
1 shared publication
Latest Publications
- 24 December 2014
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 69 (14) , 1320-1322
Investigation of electrospray stability with a dynamic liquid flow splitter
The article gives the results of research of electrospray stability with the use of a dynamic splitting of a flow in the spray area under normal conditions. An acidified water-acetonitrile solution (1: 1) was used as an eluant. Experimental results for the used configuration of electrospray junction with a coaxial selection of fluid excess as a steam-gas mixture taken out of the dispersion area (meniscus fluid on the butt-end of a capillary) in the compass of a fluid flow along the capillary from 50 up to 200 μL/min showed more stable relation of an atomized solution flow in comparison with a mode without use of a dynamic splitting of an atomized fluid flow.
- 24 December 2014
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 69 (14) , 1320-1322
Investigation of electrospray stability with a dynamic liquid flow splitter
The article gives the results of research of electrospray stability with the use of a dynamic splitting of a flow in the spray area under normal conditions. An acidified water-acetonitrile solution (1: 1) was used as an eluant. Experimental results for the used configuration of electrospray junction with a coaxial selection of fluid excess as a steam-gas mixture taken out of the dispersion area (meniscus fluid on the butt-end of a capillary) in the compass of a fluid flow along the capillary from 50 up to 200 μL/min showed more stable relation of an atomized solution flow in comparison with a mode without use of a dynamic splitting of an atomized fluid flow.
- 12 March 2013
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 27 (8) , 904-908
Electrospray ion source with a dynamic liquid flow splitter
RATIONALE: Although the electrospray method is widely used in biomedical mass spectrometry and ion‐drift spectrometry, the electrospray system can generate large drops that are the cause of electrical breakdowns, and of the fast clogging of the inlet diaphragm of the differential pumping first stage and system of ion transportation to the analyzer. Thus, a system free of such problems would be of benefit. METHODS: To drain the condensate away from the electrospraying zone and to maintain stability of spraying, a source was designed where the excessive non‐sprayed solution flowing down over the metal capillary outer wall is pumped away by an air micropump. An anti‐electrode is mounted opposite the metal capillary and is slightly tilted with respect to the horizon to make the condensed liquid flow down. RESULTS: An electrospray ion source allowing work with chromatographic flows of the solution under normal conditions was tested. The applicability of the operating modes of the electrospray ion source with dynamic liquid flow splitting for both ion‐drift and mass spectrometers was demonstrated. The flow rate range of liquid fed to the electrospray ion source with dynamic liquid flow splitting is such that it can be used in high performance liquid chromatography/Ion Mobility Spectrometry (HPLC/IMS) and HPLC/MS in the online mode. CONCLUSIONS: An electrospray ion source with a dynamic liquid flow splitter was developed and tested. Optimal operating modes of the electrospray ion source with dynamic liquid flow splitting were determined. Copyright © 2013 John Wiley & Sons, Ltd.
- 12 March 2013
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 27 (8) , 904-908
Electrospray ion source with a dynamic liquid flow splitter
RATIONALE: Although the electrospray method is widely used in biomedical mass spectrometry and ion‐drift spectrometry, the electrospray system can generate large drops that are the cause of electrical breakdowns, and of the fast clogging of the inlet diaphragm of the differential pumping first stage and system of ion transportation to the analyzer. Thus, a system free of such problems would be of benefit. METHODS: To drain the condensate away from the electrospraying zone and to maintain stability of spraying, a source was designed where the excessive non‐sprayed solution flowing down over the metal capillary outer wall is pumped away by an air micropump. An anti‐electrode is mounted opposite the metal capillary and is slightly tilted with respect to the horizon to make the condensed liquid flow down. RESULTS: An electrospray ion source allowing work with chromatographic flows of the solution under normal conditions was tested. The applicability of the operating modes of the electrospray ion source with dynamic liquid flow splitting for both ion‐drift and mass spectrometers was demonstrated. The flow rate range of liquid fed to the electrospray ion source with dynamic liquid flow splitting is such that it can be used in high performance liquid chromatography/Ion Mobility Spectrometry (HPLC/IMS) and HPLC/MS in the online mode. CONCLUSIONS: An electrospray ion source with a dynamic liquid flow splitter was developed and tested. Optimal operating modes of the electrospray ion source with dynamic liquid flow splitting were determined. Copyright © 2013 John Wiley & Sons, Ltd.
- 1 August 2012
- Published by Springer Nature in International Journal for Ion Mobility Spectrometry
- Vol. 16 (3) , 169-176
Coupling of liquid chromatograph with ion-mobility spectrometer
- 1 August 2012
- Published by Springer Nature in International Journal for Ion Mobility Spectrometry
- Vol. 16 (3) , 169-176
Coupling of liquid chromatograph with ion-mobility spectrometer